CNV 504 / 508 T-SERIES COUPLING/DECOUPLING NETWORK FOR UNSHIELDED SYMMETRICAL INTERCONNECTION LINES (COMMUNICATION LINES)

Similar documents
LD 200N GENERATOR LOAD DUMP Z FUNKCJĄ "CLIP" - LD 200N

DCD ST - SERIES COUPLING/DECOUPLING NETWORK FOR UNSHIELDED SYMMETRICAL INTERCONNECTION LINES (COMMUNICATION LINES)

AMP 200N1 LOW FREQUENCY SIGNAL SOURCE DC (0HZ) TO 250KHZ, 800W

LD 200N GENERATOR LOAD DUMP Z FUNKCJĄ "CLIP" - LD 200N

LD 200N100 GENERATOR LOAD DUMP Z FUNKCJĄ "CLIP" I ELEKTRONICZNYM PRZEŁĄCZNIKIEM BATERII

OCS 500N6F SERIES SIMULATOR FOR FAST AND SLOW DAMPED OSCILLATORY WAVES AND RINGWAVE

NETWAVE SERIES (1-PHASE) PROGRAMOWALNE WIELOFUNKCYJNE ŹRÓDŁO AC/DC

CWS 500N1.4 CONTINUOUS WAVE SIMULATOR, 80W

CTR2 / CTR2-AD CALIBRATION TARGET AND VERIFICATION ADAPTER FOR ESD

DCD SR - SERIES COUPLING/DECOUPLING NETWORKS FOR UNSHIELDED UNSYMMETRICAL INTERCONNECTION LINES

LD 200N LOAD DUMP GENERATOR WITH CLIPPING-MODULE

CWS 500N1.3 CONTINUOUS WAVE SIMULATOR, 80W

CWS 500N4 SIMULATOR FOR CONDUCTED, COMMON-MODE DISTURBANCES, AS PER IEC , IEC ANNEX C, 0HZ (DC) TO 165KHZ

LD 200N200 LOAD DUMP GENERATOR WITH CLIPPING-MODULE AND BATTERY SWITCH

VDS 200Q SERIES 4-QUADRANT VOLTAGE DROP SIMULATOR - BATTERY SIMULATOR AND DC VOLTAGE SOURCE

TRANSIENT EMISSION SET AUTOMOTIVE TRANSIENT EMISSION MEASUREMENTS AS PER ISO

UCS 500N5T SERIES MULTIFUNCTIONAL TESTGENERATOR FOR CONDUCTED TRANSIENTS (EFT/BURST, SURGE, TELECOM-SURGE & POWER FAIL) UP TO 5.

COMPACT NX5 FIRST OF ITS KIND. SHOWS ITS TRUE COLORS. THINKS FOR ITSELF.

COMPACT NX5 SERIES MULTIFUNCTIONAL TEST GENERATOR FOR TRANSIENTS (EFT/BURST, SURGE & POWER FAIL) UP TO 5.5 KV

LD 200N200 LOAD DUMP GENERATOR WITH CLIPPING-MODULE AND BATTERY SWITCH

COMPACT NX5 MULTIFUNCTIONAL TEST GENERATOR FOR TRANSIENTS (EFT/BURST, SURGE & POWER FAIL) UP TO 5.5 KV

LOAD DUMP GENERATOR WITH CLIPPING-MODULE AND BATTERY SWITCH

NETWAVE SERIES (3-PHASE) THREE-PHASE MULTIFUNCTIONAL AC/DC POWER SOURCES

CWS 500N1.4 CONTINUOUS WAVE SIMULATOR, 80W

CTR2 / CTR2-AD CALIBRATION TARGET AND VERIFICATION ADAPTER FOR ESD

NETWAVE SERIES (3-PHASE) THREE-PHASE MULTIFUNCTIONAL AC/DC POWER SOURCES

CWS 500N4 SIMULATOR FOR CONDUCTED, COMMON-MODE DISTURBANCES, AS PER IEC , IEC ANNEX C, 0HZ (DC) TO 165KHZ

VDS 200Q SERIES 4-QUADRANT VOLTAGE DROP SIMULATOR - BATTERY SIMULATOR AND DC VOLTAGE SOURCE

NETWAVE SERIES (3-PHASE) THREE-PHASE MULTIFUNCTIONAL AC/DC POWER SOURCES

UCS 500N7.2 MULTIFUNCTIONAL TRANSIENT SIMULATOR FOR RENEWABLE ENERGY

TRANSIENT EMISSION SET AUTOMOTIVE TRANSIENT EMISSION MEASUREMENTS AS PER ISO

UCS 500N7 MULTIFUNCTIONAL TESTGENERATOR FOR TRANSIENTS (EFT/BURST, SURGE & POWER FAIL) UP TO 7KV

LD 200N. Advanced Test Equipment Rentals ATEC (2832) LOAD DUMP GENERATOR FOR TESTS ACCORDING TO...

COMPACT NX5 SERIES MULTIFUNCTIONAL TEST GENERATOR FOR TRANSIENTS (EFT/BURST, SURGE & POWER FAIL) UP TO 5.5 KV

AMP 200N2 LF SIGNAL & AMPLIFIER DC (0HZ) TO 250 KHZ (500 KHZ) WITH 1,000 W

IEC Electrical fast transient / Burst immunity test

CDN 117 / 117-M CDN 118-T4 / 118-EXT-1 SIGNAL & DATA LINE COUPLING NETWORKS USER MANUAL M

Technical Specification

Advanced Test Equipment Rentals ATEC (2832) Lightning Surge Simulator LSS-F02.

COUPLING / DECOUPLING NETWORK (CDN) CDN AF TYPE, CDN CAN

AMP 200N2 LF SIGNAL & AMPLIFIER DC (0HZ) TO 500 KHZ WITH 1,000 W

Schlöder GmbH - EMC Test and Measurement Systems Model #

Coupling/Decoupling Networks (CDN)

Lightning Surge Simulator LSS-F03 series

Coupling/Decoupling Networks (CDN)

EMC standards. Presented by: Karim Loukil & Kaïs Siala

ISO/TS ELECTRICAL DISTURBANCES BY CONDUCTION AND COUPLING PART 4: ELECTRICAL TRANSIENT CONDUCTION ALONG SHIELDED HIGH VOLTAGE SUPPLY LINES ONLY

Technical Specification

Voltage dips short interruptions with PFS and Netwave

Fast transient burst simulator

ENY81 Coupling Network

INTERNATIONAL STANDARD

Coupling- / Decoupling Network. 150 khz 300 MHz. 150 khz 230 MHz. 10 khz 230 MHz. IEC and CISPR 15 / CISPR 22 IEC

Conducted Immunity Testing

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Voltage Transient Emission Test

High-Voltage Capacitive Compensation Unit for Transformer and Shunt Reactor Testing, Type HVCC

Surge Generator for MIL-STD 1275

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

Combination Wave Test System

Center for Quality Engineering. Test Report No.: B0JA0002

Datasheet. Modular Inverter System VARIS Datasheet VARIS

Measuring current transformers of the W, W series

Measuring current transformers of the W AB(P) series

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

Electronic Circuit Breaker with reset input ESS20-1..

DS200ID-CD100. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 2 ppm. MPS for particles accelerators

Resistive capacitive voltage divider

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

SPINNER PMR Portfolio

Electronic Circuit Breaker ESS20-0..

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

METRISO. Analog Insulation, Low Resistance and Voltage Measurement Instrument /9.14

electronics Data Sheet Industrial Amplifier Special features Dimensions (in mm; 1 mm= inches) B en

SINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

Accessories. Accessories

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

Coupling / decoupling network (CDN) for screened or coaxial cables

PHOENIX CONTACT

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Technical Requirements for Resistibility of Telecommunications Equipment to. Overvoltage and Overcurrent

EMC TEST REPORT For CE

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

COUPLING NETWORK (CN) FOR IEC / EN , DC TO 150 khz

G.R.A.S. Sound & Vibration

TISP4G024L1W G.Fast VDSL Protector

Technical Requirements for Resistibility of Telecommunications Equipment to. Overvoltage and Overcurrent

ICT 2.3 Three-phase Isolation Current Transformer

V1.3. TBLC08 50mH AC-LISN TBLC08

DS400ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1.5 ppm. MPS for particles accelerators

EGSTON POWER SUPPLY N2xxSW 12W

OPTITEMP TT 20 Technical Datasheet

IB IL 24 PWR IN/PS IB IL 24 PWR IN/PS-PAC

PRODUCT DATA. Sound Intensity Calibrator Type 4297

Type: EASY719 DA RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC. Description

Transcription:

CNV 504 / 508 T-SERIES COUPLING/DECOUPLING NETWORK FOR UNSHIELDED SYMMETRICAL INTERCONNECTION (COMMUNICATION ) DO BADAŃ ZGODNIE Z... > EN 61000-4-5 > IEC 61000-4-5 > ITU-T K.44 CNV 504 / 508 T-SERIES - COUPLING DECOUPLING NETWORKS FOR UNSHIELDED COMMUNICATION Surge pulses and Telecom Surge pulses are applied to unshielded symmetrical interconnection lines (communication lines) by means of standalone coupling/decoupling networks. The CNV 504T5 is designed for 4 lines (2 pairs) and the CNV 508T5 for 8 lines (4 pairs) and can also be used for either 4, 2 or 1 pairs. According to IEC 61000-4-5 Ed.3, (Fig. 10) the pulses are coupled via gas arrestors and a matching resistor per line. HIGHLIGHTS > As per IEC 61000-4-5 Ed.3, Fig 10/A4, ITU K.44 OBSZARY ZASTOSOWAŃ INDUSTRY > For test pulse 1.2/50-8/20µs and 10/700µs > Coupling via gas arrestor or other coupling > Built-in matching resistors > 20mH decoupling, current compensated pairs > Test voltage up to 5kV MEDICAL RESIDENTIAL TELECOM > Line voltage 50V > Line current 1A EM TEST > STRONA 1/5

SURGE 1.2 /50 US SURGE 10/700 US CNV 504 / 508 T-SERIES - SURGE COUPLING/DECOUPLING NETWORKS FOR COMMUNICATION CNV 504 / 508 T-SERIES - TELECOM SURGE COUPLING/DECOUPLING NETWORKS FOR COMMUNICATION The EM TEST CNV 504 / 508 T-series coupling/ decoupling networks are designed to couple Surge pulses (1.2/50us 8/20us) and Telecom Surge pulses (10/700us) onto unshielded symmetrically operated communication lines. The CNV 504 / 508 T-series is also designed as per figure A4 of IEC 61000-4-5 Ed.3 without primary protector. If required, an additional primary protector must be integrated according the user specifications. The CNV-models includes the coupling via gas arrestor plus the internal matching resistor Rc as per figure 10 of IEC 61000-4-5 Ed.3 with values as per the formula given by the standard. All lines are subjected to the test pulse simultaneously with respect to ground. With short circuit bridges and individual designed coupling devices the user can easy modify the coupling mode and number of tested lines to the requirements. EM TEST offers CNV 504 / 508 T-series coupling/decoupling networks for test voltages up to 5kV. The CNV also include the required decoupling part consisting of decoupling inductors of 20mH for each line, pairwise current compensated. To further protect the auxiliary equipment being needed for testing the DUT an additional protection circuit is integrated at the communication line input. EM TEST > STRONA 2/5

CNV 504T5 FOR 4 UNSHIELDED CNV 504T5 FOR 4 UNSHIELDED COMMON DATA CNV 504T5 ACCESSORIES CDN for 4 lines (2 pairs) as per IEC 61000-4-5 Ed.3, - Surge pulses (Fig. 10), - Telecom Surge (Fig. A4) HVS - Banana Banana HV cable 1.0 m 1 x red (HV) 1 x black (COM) Earth cable Max. voltage 5 kv impulse Line voltage max. 50 V Art. 10945 1 x 0.6 m yellow-green 2 x M4 screws with toothed washer Line current max. 1 A Short circuit bridges Coupling Selectable - GDT, gas arrestor - Individual CD 8 bridges, 4 x (25/160) ohm resistors, 4 x coupling Safety lab cables Art:105886 8 x 0.25 m Safety lab cables Surge Pulse 1.2/50 µs, 4 x 160 ohm (2 pairs), 2 x 80 ohm (1 pair) Telecom surge 10/700 µs, 4 x 25 ohm Decoupling 20 mh decoupling inductor, ± 10 % tolerance, pairwise current compensated Residual voltage at the AE port, 5 kv impulse 88 V (1.2/50 µs), 80 V (10/700 µs) Signal Bandwith 100 khz with 600 ohm load GENERAL DATA CNV 504T5 Connectors 4 mm safety lab sockets Dimensions 447 mm x 400 mm x 143 mm Weight 11.20 kg EM TEST > STRONA 3/5

CNV 508T5 FOR 8 UNSHIELDED CNV 508T5 FOR 8 UNSHIELDED COMMON DATA CNV 508T5 ACCESSORIES CDN for 8 lines (4 pairs) as per IEC 61000-4-5 Ed.3, - Surge pulses (Fig. 10), - Telecom Surge (Fig. A4) HVS - Banana Banana HV cable 1.0 m 1 x red (HV) 1 x black (COM) Earth cable Max. voltage 5 kv impulse Line voltage max. 50 V Art. 10945 1 x 0.6 m yellow-green 2 x M4 screws with toothed washer Line current max. 1 A SCC Short circuit bridges Coupling Selectable - GDT, gas arrestor - Individual CD 16 bridges, 8 x (25/320) ohm resistors, 8 x coupling Safety lab cables Art:105886 18 x 0.25m Safety lab cables Manual English and German manual on CD Surge Pulse 1.2/50 µs, 8 x 320 ohm (4 pairs), 4 x 160 ohm (2 pairs), 2 x 80 ohm (1 pair) Telecom surge 10/700 µs, 8 x 25 ohm Decoupling 20 mh decoupling inductor, ± 10 % tolerance pairwise current compensated Residual voltage at the AE port, 5 kv impulse 85 V (1.2/50 µs), 60 V (10/700 µs) Signal Bandwith 100 khz with 600 ohm load OPTIONS COUPLING DEVICES ABD Plug 140 V Avalanche Breaking Diode Coupling diode for Surge 1,2/50 µs and Telecom Surge 10/700 µs Max. Impulse voltage 7 kv GENERAL DATA CNV 508T5 Connectors 4 mm safety lab sockets Dimensions 447 mm x 400 mm x 143 mm Weight 16.65 kg GENERAL DATA ENVIRONMENT Temperature 5-40 C Rel. humidity 10-90 %, non-condensing Atmospheric pressure 86 kpa (860 mbar) to 106 kpa (1,060 mbar) EM TEST > STRONA 4/5

KOMPETENTNI, GDZIEKOLWIEK BYŚ BYŁ BEZPOŚREDNI KONTAKT Z EM TEST Szwajcaria USA / Kanada EM TEST (Switzerland) GmbH > Sternenhofstraße 15 > 4153 Reinach > Switzerland Telefon +41 (0)61/7179191 > Fax +41 (0)61/7179199 Internet: www.emtest.ch > E-mail: sales.emtest@ametek.com AMETEK Compliance Test Solutions > 52 Mayfield Ave. > Edison > NJ 08837 Telefon +1 (732) 417-0501 Internet: > E-mail: sales.emtest@ametek.com Niemcy AMETEK CTS Germany GmbH > Lünener Straße 211 > 59174 Kamen > Deutschland Telefon +49 (0)2307/26070-0 > Fax +49 (0)2307/17050 Internet: > E-mail: info.cts@ametek.de Francja EM TEST FRANCE > Le Trident - Parc des Collines > Immeuble B1 - Etage 3 > 36, rue Paul Cézanne > 68200 Mulhouse > France Telefon +33 (0)389 31 23 50 > Fax +33 (0)389 31 23 55 Internet: www.emtest.fr > E-mail: info@emtest.fr Chiny E & S Test Technology Limited > Rm 913, Leftbank > No. 68 Bei Si Huan Xi Lu > Haidian District > Beijing 100080 > P.R. China Telefon +86 (0)10 82 67 60 27 > Fax +86 (0)10 82 67 62 38 Internet: > E-mail: info@emtest.com.cn Republika Korei EM TEST Korea Limited > #405 > WooYeon Plaza > #986-8 > YoungDeok-dong > Giheung-gu > Yongin-si > Gyeonggi-do > Korea Telefon +82 (31) 216 8616 > Fax +82 (31) 216 8616 Internet: www.emtest.co.kr > E-mail: sales@emtest.co.kr Polska EM TEST Polska > ul. Ogrodowa 31/35, 00-893 Warszawa > Polska Telefon +48 (0)518 64 35 12 Internet: /pl > E-mail: infopolska.emtest@ametek.com Wszystkie informacje dotyczące dostaw, wyglądu zewnętrznego i danych technicznych opisujących aktualny stan wraz z datą publikacji mogą ulec zmianie bez wcześniejszych informacji. EM TEST > STRONA 5/5