Detection of Incorrectly Set Work Press Position Confirmation Detection of Bent Drills. Press D5C

Similar documents
Overtravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0

Type Poles Contact configuration Rated voltage Model G7S-4A2B 24 VDC 3PST-NO, 3PST-NC

Type Poles Contact configuration Rated voltage Model 3PST-NO, 3PST-NC 24 VDC

Type Sealing Poles Contact configuration Rated voltage Model. Type LED indicator Poles Rated voltage Model

Fluoro plastic housing for highest chemical and detergent resistance

Ordering Information. Power Relay G2A. Model Number Legend Highly Reliable, 4-pole Miniature Relay Ideal for Sequence Control

Model Number Structure

Sensing method Appearance Sensing distance Operation mode Model. Emitter E3S-2LE4 Through-beam *1. 2 m. 0.1 to 2 m. 300 mm. 2 m

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

Model Number Structure

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder

Ordering Information. Stepping Relay Unit G9B. Model Number Legend

Non-Ferrous-Metal-Detecting Proximity Sensor (Separate Amplifier Type)

Resolution (divisions) Pre-wired Model E6F-AB3C 360P/R 2M *2 Pre-wired Connector E6F-AB3C-C 360P/R 2M *2 Model (2 m) NPN open collector BCD 360

TL-W5MD1 2M *1 *3 TL-W5MD2 2M

G7K. Latching Relay. Compact Mechanical Lock Latching Relays with Manual Buttons. Model Number Structure. Ordering Information

Name Model Specifications/Design ID Tag V700-D23P31 20 dia. t 2.7 mm Coin-shaped 256 bytes (with user area of 240 bytes)

Ordering Information. Ratchet Relay G4Q. Plug-in Models. Model Number Legend

E8EB-N0C2B E8EB-N0B2B

Switch Mode Power Supply

G70R-SOC08 CSM_G70R-SOC08_DS_E_2_1

CSM_G7S-_-E_DS_E_7_1

Reverse Protection Relay 2. Control Power Supply Voltage None: 200/220 VAC 380: 380/400 VAC 440: 440 VAC

Pre-wired Photomicrosensor with Amplifier and Cable EE-SPW321/421 Compact, Thin-profile Photomicrosensor with special amplifier.

Sensing method Sensing distance Model

MY-GS CSM_MY-GS_DS_E_2_1

DPDT+DPST-NO MM4KP-JD MM4XKP-JD

Sensing method Appearance Sensing distance Operation mode Model Convergent-reflective (narrow vision field) 30 to 100 mm (variable)

Model Number Structure

AC 24, 110, 120, 230, 240 DC 6, 12, 24, 48 LED indicator with test button G2R-1-SNI (S) G2R-2-SNI (S) Diode

MK CSM_MK_DS_E_2_2. Compact Power Relays. A Wide Variation of Octal Pin Power Relays. Model Number Structure

Standard model G2A-432A-US G2A-4321P-US. Arc barrier equipped model G2A-432AY-US ---

E3X-DRT21/SRT21/CIF11

E6F-CWZ5C (1000P/R) 2M

Resolution (pulses/rotation) 100, 200, 300, 360, , 720, 800 1,000, 1,024, 1,200 1,500, 1,800, 2,000 2,048, 2,500, 3, , , 360, 500

Model Number Structure

Phase-sequence Phase-loss Relay

Model Number Structure

SPECIFICATIONS. For Reference. This specification sheet is for reference only, Please request it again if a specification for receipt is necessary.

Original instructions INCA-1 Tina Emergency stop for enclosure installation INCA-1S Tina Safety stop for enclosure installation

Switch Mode Power Supply

G5Q. Ordering Information. Specifications. PCB Relay. Compact, High Isolation Relay J COIL RATINGS. 638 PCB Relay G5Q

V700-series. Electromagnetic Inductive RFID System. ID Tag. Antenna. Controller

E3JM/E3JK. Two Models Contribute to Overall Cost Reduction. Built-in Power Supply Photoelectric Sensor. Ordering Information

Alternate Operation Relay 61F-AN/-APN2

Digital Panel Meter K3TE. Model Number Structure. Model Number Legend. Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input K3TE

E6F-CWZ5C (1000P/R) 2M

Single-phase Voltage Relay

2. Terminal Shape P: PCB terminals B: Screw terminals T: Quick-connect terminals (#250 terminal)

Single-phase Current Relay

22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection

3. Contact Form A: SPST-NO

256, 360, 720, 1,024. E6C3-AN1E 256P/R 1M Voltage output Binary VDC E6C3-AN2E 256P/R 1M

Floatless Level Switch (Ultra High-sensitivity Type) 61F-UHS/-HSL

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

Model Number Structure

LED Displacement Sensor

Resolution (pulses/rotation) 100, 200, 300, 360, , 720, 800 1,000, 1,024, 1,200 1,500, 1,800, 2,000 2,048, 2,500, 3, , , 360, 500

D7F. Detects Changes in Machine. Vibration. Vibration Sensor with Linear Output or Manual Setting. Ordering Information

Output configuration Resolution (pulses/rotation) Model. 10, 20, 30, 40, 50, 60, 100, 200, 300, 360, 400, 500, 600 E6C2-CWZ6C (resolution) 2M

E2F. Cylindrical Proximity Sensor in Plastic Housing. Applications. Ordering Information. Sensors. Accessories (Order Separately)

High-precision Optical Switch

20 Series Power Relays

2 m ZX1-LD50A61 2M ZX1-LD50A81 2M Pre-wired. 50 ± 10 mm

* (110 VAC) in this catalog have been discontinued at the end of March L 2KM: Long-distance (for 2 km)

Multipoint Temperature Controller

Inductive Proximity Sensor

E6B2-C. General-purpose Encoder with External Diameter of 40 mm. Incremental 40-mm-dia. Rotary Encoder. Ordering Information

Distance-setting Photoelectric Sensor

Capacitive Proximity Sensor

Rated time Time setting range Time division 1 week 00:00 a.m. to 11:59 p.m. 1 min

Classification Terminal Shape Contact form Enclosure rating Model Rated coil voltage

Solid-state Timer H3DE

Phase-sequence Phase-loss Relay

G5NB. A Miniature Relay with 1-pole 3A/5A Switching Capability and 10 kv Impulse Withstand Voltage. Application Examples. Model Number Legend

NEW. Better Productivity by Standstill and Low-speed Monitoring

Three-phase Undervoltage and Phase-sequence Phase-loss Relay

4. Classification E: High capacity. 3. Terminal Form Blank: Tab terminals (#250 terminals) Tab terminals #250 SPST-NO

Limit Switch Style Inductive Prox

Features. 2-Dimensional Code Reader (Fixed Type) V530-R150E-3, EP-3

Three-phase Asymmetry and Phase-sequence Phase-loss Relay

Distance-setting Photoelectric Sensor

Power Relays G7Z. Model Number Structure. Model Number Legend Relay with Auxiliary Contact Block. New Product Relay

Single-phase Current Relay

Relays with Forcibly Guided Contacts G7SA

Solid-state Twin Timer

Classification Contact form Enclosure rating Terminal shapes Model Minimum packing unit Standard. SPST-NO (1a) Fully sealed PCB terminal

Supply voltage Output configuration Resolution (P/R) Model 12 to 24 VDC Complementary output 100, 200, 360, 500, or 600 E6F-CWZ5G 1,000

Cylindrical type proximity sensor

Surface-mounting Relay

Z4D-F. LED-type Micro Displacement Sensor with Many Features in a Compact Body. Micro Displacement Sensor. Ordering Information.

Sensing method Through-beam Retroreflective Diffuse reflective Convergent-beam Appearance Side-view Flat Side-view Flat Side-view

Application Examples. Features. Ultrasonic Displacement Sensor E4PA-N. Now, more advanced with a new mutual interference prevention function.

Operating mode. distance. 7 m Light ON Dark ON (selectable) 2 m [100 mm] (See note 1.) 100 mm (wide view)

onlinecomponents.com

Label Sensor. Ordering Information. Application Example E3S-CD68/CD63. Ideal for Detecting Labels on Bottles. E3S-CD68/CD63 Label Sensor

Ordering Information. Latching Relay MMK. Available Models. Models Conforming to Auxiliary Power Relay Specifications

Three-phase Asymmetry and Phase-sequence Phase-loss Relay

E3S-C. Built-in Amplifier Photoelectric Sensor. Water- and Oil-resistive Photoelectric Sensor with Metal Housing Ensuring Long Sensing Distance

TL-W5MD1 2M *1 *3 TL-W5MD2 2M

Transcription:

Touch Switch CSM DS_E 3 Unique 18-mm-dia. Capacitive Touch Switch with Choice of Three Actuators is Activated with Only a Very Slight Physical Contact Only a slight activation force is required, enabling detecting micro deflections, thin wires, or thin-plate conductors (e.g., steel or stainless). Application possible for non-conductors by indirectly connecting to ground. Instantaneous operation upon contact with extremely limited hysteresis for high-precision position detection. Diameter of only 18 mm with standard built-in amplifier, operation indicator, and sensitivity adjustment. Conforms to IEC IP67 * Freely replaceable antenna with screw mounting. Free attachment to enable changing the antenna shape according to the application. * Malfunction may occur if used in locations subject to water or oil. Application Examples Be sure to read Safety Precautions on page 6 to 7 and Safety Precautions for All Limit Switches. Detection of Incorrectly Set Work Press Position Confirmation Detection of Bent Drills Press Press Detection of Fine Wire or Thin Plate Detection of Loose Screws Detection of Loose Wires Wire Steel plate 1.0 mm Detection of End of Cloth or Paper (Detected with indirect ground) The detects the end of the paper or cloth when the antenna touches ground. Detection of Seams in Cloth or Paper (Detected with indirect ground) The detects the seam when the antenna touches ground pole. Ground pole Paper or cloth Paper or cloth Ground surface 1

Ordering Information Features Actuator Usable by bending tip of antenna. Overtravel of 20 mm max. Ideal for high-accuracy position control. Overtravel of 3.5 mm max. Any actuator can be attached. Coil spring Plunger Free-attachment Item Model Model Model Supply voltage DC -1DS0-1DP0-1DA0 (Power supply) AC -1AS0-1AP0-1AA0 Antenna only -00S0-00P0-00A0 Note: The lead wire is 3 m. Specifications Ratings and Characteristics Type DC AC Item Model -1D@0-1A@0 Degree of protection Equivalent to IP67 Mechanical durability 10,000,000 operations min. (at rated overtravel value) Supply voltage (operating voltage) 12 to 2 VDC (10 to 30 VDC), (ripple: 10% max.) to 20 VAC (5 to 26 VAC), 50/60 Hz Rated frequency --- 50/60 Hz Sensitivity setting range 30 to pf Current consumption 17 ma max. --- Leakage current Circuit --- 2 ma max. Antenna 1 ma max. 1 ma max. Response time 2 ms max. 8 ms max. Output current 200 ma max. (resistive load) Insulation resistance 50 MΩ min. (at 500 VDC) between lead wires and case Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and non-current-carrying metal parts Rated insulation voltage (Ui) 1,000 VAC Pollution degree (operating environment) 3 (IEC97-5-1) Protection against electric shock Class II 2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and non-current-carrying metal parts Proof tracking index (PTI) 175 Switch category D (IEC335) Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude Shock resistance 1,000 m/s 2 max. Ambient temperature Operating: 25 C to +70 C (with no icing) Ambient humidity 35% to 95%RH Weight Approx. 110 g (in case of -1DS0) Approx. 120 g (in case of -1AS0) 2

Engineering Data (Typical Examples) Temperature Characteristics of DC Models -1D@0 (2 VDC) 200 Temperature Characteristics of AC Models -1A@0 ( VAC) 200 ( ) set to minimum sensitivity Sensitivity (pf) 150 50 ( ) set to minimum sensitivity ( set to maximum sensitivity ) Sensitivity (pf) 150 50 ( set to maximum sensitivity ) 0 0 25 0 0 70 80 Temperature ( C) Voltage Characteristics of DC Model -1D@0 (Ambient temperature: 25 C) 200 0 0 25 0 0 70 80 Temperature ( C) Voltage Characteristics of AC Model -1A@0 (Ambient temperature: 25 C) 200 150 ( ) set to minimum sensitivity 150 ( ) set to minimum sensitivity Sensitivity (pf) Sensitivity (pf) 50 ( set to maximum sensitivity) 50 ( set to maximum sensitivity) 0 10 20 30 0 200 300 Voltage (V) Voltage (V) Structure and Nomenclature Nomenclature Coil spring actuator (Stainless steel) O-ring Contactor LED operation indicator Sensitivity adjuster O-ring Actuator Case Washer Mounting nut Lead wire Filled with glass epoxy Operating Principle The limit-type Touch Switch vibrates at a high frequency. When an object touches the antenna......the oscillation circuit constant changes, oscillation stops......the switching circuit operations, and an output signal is produced. Use the specified voltage. Feedback circuit Antenna Oscillator Detection circuit NOT circuit Power supply 3

Series Classification and Features -1D@0 Power supply 1 200 ma max. 12 to 2 VDC L/R 0-1A@0 200-mA load max. Cosφ = 1 Power supply to 20 VAC The by itself can directly switch a load if DC power is provided. An AC power supply can be detected and an AC load can be switched. Connections Output Circuit Diagram The lead wire colors of the have been changed in compliance with the latest applicable JIS standards. Colors in parentheses are previous ones. -1D@0 (DC Model) -1A@0 (AC Model) Brown (Red) Switch main circuit.7 kω Black (White) Blue (Black) 12 to 2 VDC Switch main circuit Brown (White) to 20 VAC Blue (Black) Dimensions (Unit: mm) DC Models Coil Spring -1DS0 101.5 51 1 (162.5) 37 61 56 Overtravel 16.5 dia. 6.5 dia. 16.7 dia. 29 dia. dia. 7.1 dia. 1.2 dia. *1 Two internal lock washers Width: 2 *1. The stainless steel wire actuator can move in any direction. However, ( Thickness: ) limit the overtravel to within 20 mm from the free position. The force that pushes the actuator must not exceed 1.96 N. dia., three conductors 0.2 mm 2. Plunger -1DP0 Overtravel 2 (85) 37 61 56 16.5 dia. 5 dia. 16.7 dia. 29 dia. dia. 7.1 dia. *1 Two internal lock washers Width: 2 *1. The overtravel of the stainless steel plunger is within 3.5 mm. ( Thickness: ) Do not apply a force greater than 9.8 N to the plunger. dia., three conductors 0.2 mm 2.

Free-attachment -1DA0 Lock nut M 0.7 *1 28 1 (89) 37 61 56 16.5 dia. 16.7 dia. 29 dia. dia. 7.1 dia. Self-locking nut Two flat washers Two internal lock washers Width: 2 *1. Limit the total length of actuator wire to 1 m or less. ( Thickness: ) When mounting the Switch to a metal plate, do not exceed an area of 200 cm 2. dia., three conductors 0.2 mm 2. AC Models Coil Spring -1AS0 101.5 51 1 (177.5) 52 76 71 Overtravel 16.5 dia. 6.5 dia. 16.7 dia. 29 dia. dia. 7.1 dia. 1.2 dia. *1 Two internal lock washers Width: 2 *1. The stainless steel wire actuator can move in any direction. However, ( Thickness: ) limit the overtravel to within 20 mm from the free position. The force that pushes the actuator must not exceed 1.96 N. dia., three conductors 0.3 mm 2. Plunger -1AP0 Overtravel 2 (101) 76 71 52 16.5 dia. 5 dia. 16.7 dia. 29 dia. dia. 7.1 dia. *1 Two internal lock washers Width: 2 *1. The overtravel of the stainless steel plunger is within 3.5 mm. ( Thickness: ) Do not apply a force greater than 9.8 N to the plunger. dia., three conductors 0.3 mm 2. Free-attachment -1AA0 Lock nut M 0.7 *1 28 1 (10) 52 76 71 16.5 dia. 16.7 dia. 29 dia. dia. 7.1 dia. Self-locking nut Two flat washers Two internal lock washers Width: 2 *1. Limit the total length of actuator wire to 1 m or less. ( Thickness: ) When mounting the Switch to a metal plate, do not exceed an area of 200 cm 2. dia., three conductors 0.3 mm 2. 5

Safety Precautions Refer to Safety Precautions for All Limit Switches. CAUTIONS Make sure that the antenna does not come into contact with the human body, otherwise an electric shock may be received. Precautions for Correct Use Mounting Do not tighten the nuts with excessive force. The maximum permissible tightening force of each nut with a washer is 29. N m. Mounting Hole Dimension Antenna <Shape and Extension> If a metal plate is used as an antenna by connecting it to the built-in or separated antenna of the, the surface area of the metal plate must be 200 cm 2 maximum (Fig. 1). The antenna can be extended, provided that the total length of the antenna is 1 m maximum (Fig. 2) and that the bottom of the antenna is at least 10 cm (Fig. 3) away from the ground. Refer to the illustrations below The may be damaged if the antenna is excessively large or heavy or if the antenna is used in locations with excessive vibration or shock. Be sure to check the locations before use. Fig. 1 Metal plate 200cm 2 max. Fig. 2 1 2 6 5 Fig. 3 1 m max. 10 cm min. Grounding of Antenna and Sensing Object 18.5 +0.5-0 dia. <Size of Sensing Object> Grounded Object If the sensing object is the following grounded conductor, its size will not affect the operation of the. Check for the presence of insulators sticking to the sensing object or the corrosion of the sensing object, however, so that the ground resistance will not exceed 3 kω. 3 1+ --- 6 1 m Ground <Parallel Arrangement> If there are multiple s are located in parallel, make sure that the distance between adjacent antennas is at least 3 cm. 3 cm min. Contact with Grounded Conductor The sensing object is equivalently grounded through ground resistor R. 3 cm min. Grounded conductor R: 3 kω max. The sensing object must not come into contact with the human body Non-grounded Object If the sensing object is the following non-grounded conductor, the will operate if the capacitance between the sensing object and the ground is 30 pf or more. The larger the surface area of the sensing object is, the higher its capacitance will be. The shorter the distance between the sensing object and the ground is, the higher the capacitance will be. Furthermore, the capacitance greatly varies with the ground condition (e.g., dry sand, concrete, or wet soil). Contact with Non-grounded Conductor The sensing object is equivalently grounded through capacitor C. 30 pf min. C C: 30 pf min. 3 kω max. Non-grounded conductor R <Conditions of Sensing Object> The detection of conductors (e.g., iron, stainless steel, aluminum, and brass objects) poses no particular problem. A conductor coated with paint cannot be detected, however, because there is no electrical continuity between the antenna and the conductor. Non-conductive objects (e.g., plastic, ceramic, glass, and cloth objects) can be detected by grounding them indirectly. (Refer to Application Examples on page 1.) Generally, the conductor will be detectable if the ambient humidity is 60% to 70%RH and the surface area of the conductor is approximately 300 500 mm. Maintenance Make sure that the portion of the antenna that comes into contact with sensing objects is free of oil, dirt, or rust, or any other insulator. Otherwise, the will not operate. The degree of protection of the is IP67. The cannot be, however, used in the water or oil. Locations with Sprayed Water or Oil The may malfunction in locations where the is frequently exposed to sprayed water or oil. Especially, the may malfunction more frequently if it is exposed to sprayed watersoluble cutting oil. In such locations, be sure to take appropriate measures to protect the from oil and water. Wiring and Connections Be sure to wire the correctly according to the color of each cord. Incorrect wiring may damage the internal components of the or the may malfunction. A maximum of two models can be connected in series provided that to 20 V is supplied. DC models cannot be connected in series. to 20 VAC Be sure to supply power to the via the load. If power is supplied to the directly, the fuse will blow. Power source If there are wire power lines or high-tension lines close to the cable of the, be sure to wire the cable of the away from power lines or high-tension lines or lay the cable in an exclusive, shielded conduit. Remove the caution label on the end of the cable before wiring the cable. 6

-1A@0 (AC Models) Be aware that the -1A@0 not in operation has a leakage current of approximately 2 ma. Especially, if the load is a relay with a current flow of 10 ma or less, a reset failure may result due to the residual voltage. Therefore, connect a bleeder resistor as shown below so that the residual voltage will be less than the reset voltage of the load. Bleeder resistor R AC power supply Vs The bleeder resistance and permissible power are obtained from the following formula. Vs Vs 2 R 10 I (KΩ) P> R (mw) P: W number of bleeder load (Practically, the wattage must be a few times larger than the obtainable value.) I: current (ma) If a DC relay or DC counter is used as a load connected through an electronic timer or current rectification circuit, pay the utmost attention so that the leakage current of the AC model will not cause the load to malfunction. Others Do not disassemble the, otherwise the internal wiring will be damaged and the will fail to operate. The sealing of the uses nitrile butadiene rubber (NBR), which is highly oil resistive. If exposed to some types of oil or chemical indoors or outdoors, however, the NBR may deteriorate. Contact your OMRON representative for details. When mounting the antenna to the, be sure to tighten the antenna to a torque of 0.39 to 0.83 N m. If the antenna is not tightened securely, the built-in contact may break. If an appropriate antenna is mounted to a free attachment model, hold the nut on the outer side with a wrench so that the nut will not move. Then tighten the nut on the inner side within a torque range of 0.78 and 1.18 N m. Direction of turn Antenna Wrench Sensitivity Adjustment The sensitivity of the can be adjusted by turning the adjuster on the rear side with a flat-blade screwdriver. The sensitivity increases by turning the adjuster clockwise (max. 30 pf) and decreases by turning the adjuster counterclockwise (min. pf). SENSI Set point Be sure to turn the adjuster with a torque of 0.08 N m or less. If excessive torque is applied, the adjuster will break. Grounding <For DC and AC Models> In order to maintain the operational reliability of the, be sure to ground the blue or black wire of the power cable. (Refer to Output Circuit Diagram on page.) Operation may fail if the is not grounded. <DC Models> The service power supply of the PC (Programmable Controller) is not available to the -1D@0. The negative line of the service power supply of the PC is not grounded. Therefore, the may not operate. Furthermore, if the negative line of the service power supply is grounded, the noise resistance of the PC will drop. <AC Models> Provided that single-phase 200 V is supplied to the -1A@0, if one phase is grounded, the power supply will be short-circuited and a machinery breakdown will result. Use an isolating transformer and ground the secondary side of the transformer instead. In the above case, be sure to ground the secondary side, otherwise the may not operate. Brown (White) Blue (Black) The lead wire colors of the have been changed in compliance with the latest applicable JIS standards. Colors in parentheses are previous ones. AC 7

Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ 2013.1 In the interest of product improvement, specifications are subject to change without notice. (c)copyright OMRON Corporation 2013 All Right Reserved.