INCLINOMETER RS232 SWITCH

Similar documents
Instruction Manual D-Series Inclinometer

User manual. Inclinometer with Analog-RS232-Interface IK360

Instruction Manual DPG-Series Inclinometer

Instruction Manual Single and Dual Axis Inclinometer P-Series

Instruction Manual DPG-Series Inclinometer

Specification DPG-Series Inclinometer

ABSOLUTE MAGNETIC ROTARY ENCODER ANALOG

Features. Description. General Specifications. VS Series Inclinometer : Dual Axis, RS232 and Analogue Output

Parameter Value Unit Notes

ABSOLUTE ROTARY ENCODER SSI

Absolute Rotary Encoder EXAG Explosion Proof. Device Net

BW-IMU200 Serials. Low-cost Inertial Measurement Unit. Technical Manual

ABSOLUTE ROTARY ENCODER CAN-BUS

ABSOLUTE ROTARY ENCODER SSI PROGRAMMABLE

ABSOLUTE ROTARY ENCODER DEVICE NET

ABSOLUTE ROTARY ENCODER SSI

ABSOLUTE ROTARY ENCODER SSI

Absolute Rotary Encoder EXAG Explosion Proof. Canopen

ABSOLUTE MAGNETIC ROTARY ENCODER ANALOG

HG G B. Gyroscope. Gyro for AGV. Device Description HG G B. Innovation through Guidance. Autonomous Vehicles

Instruction Manual Single and Dual Axis Inclinometer V-Series

Technical data. General specifications. Measurement range min max. 360

DATASHEET ABSOLUTE MAGNETIC ROTARY ENCODER SSI

P-Series Inclinometer

POSICHRON position sensor in stick design. Protection class. Voltage: V, 3 wire Current: ma, 3 wire

ICAM. Electronics & Software. Industrial Charge Amplifier for Applications in Manufacturing. Type 5073A...

CD4 Series with linear image sensor and electronic shutter provides accurate measurement.

Luminescence Sensors. Operating Instruction

Online data sheet. CLV601-0D200 CLV60x BAR CODE SCANNERS

Absolute multi-turn hollow shaft encoder BOMH Dignalizer SSI

ABSOLUTE ROTARY ENCODER DEVICE NET

Cable transducer Analog output / redundant Measuring length absolute up to 5 m

Temposonics. R-Series SSI. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Stroke length mm. Perfect data processing 0.

Data Sheet THE SCA121T DUAL AXIS INCLINOMETER MODULES. Features. Applications

Technical data. General specifications. Linearity error ± 0.1 Electrical specifications Operating voltage U B

Technical data. General specifications V DC Power consumption P 0. 1 W Time delay before availability t v

SOLAR-360 : 360 Inclinometer, RS232 or RS485 Output

Multiturn absolute encoder

SOLAR-2 : Dual Axis Inclinometer, RS232 or RS485 Output

NOVOHALL Rotary Sensor touchless transmissive. Series RFX-6900

Encoder - Absolut 2RMHF-SSI

Temposonics. E-Series Model ER. Magnetostrictive, Absolute, Non-contact Linear-Position Sensors. Analog and Start/Stop Outputs.

Temposonics. R-Series SSI. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Measuring length mm. Perfect data processing I 7 I

ABSOLUTE ROTARY ENCODER MULTI-TURN BIT PARALLEL

Magnetic absolute multi-turn hollow shaft encoder BMMH MAGRES SSI

Technical data. General specifications V DC No-load supply current I 0. typ. 50 ma Power consumption P 0

Temposonics. Magnetostrictive Linear Position Sensors. ER Start / Stop Data Sheet

Cost efficient design Operates in full sunlight Low power consumption Wide field of view Small footprint Simple serial connectivity Long Range

P-Series Inclinometer

Technical data. General specifications. Linearity error ± 0.1 Functional safety related parameters MTTF d 700 a at 40 C Mission Time (T M ) L 10

Specification DPL-Series Inclinometer Module

Magnetic sensor MSK5000 Incremental, digital interface, resolution 1 μm, scaling factor

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

Incremental hollow shaft encoder BRIH EcoMag

Model D875 Mini Tuff Tilt Digital Tiltmeter

Cost efficient design Operates in full sunlight Low power consumption Wide field of view Small footprint Simple serial connectivity Long Range

Brushless DC Motor Controller Specification Assemblies 025F0248

ED701 General Industry Pressure Transmitter

GPRS Inclinometer. Zigbee. CDMA Vibration-wire. SSI PWM Switch Analog. Features. Descriptions

An internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.

Picture 1 PC & USB Connection

Absolute encoders - SSI

BW-VG525 Serials. High Precision CAN bus Dynamic Inclination Sensor. Technical Manual

Absolute encoders - SSI Solid shaft with clamping or synchro flange Optical multiturn encoders up to 14 bit ST / 16 bit MT

CMPS09 - Tilt Compensated Compass Module

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Absolute encoders - SSI Shaft with clamping or synchro flange Optical multiturn encoders 14 bit ST / 12 bit MT

Magnetic sensor MSK320 Incremental, digital interface, resolution 12.5 μm, scaling factor 64 1

REE series digital interpolators

Absolute encoders - analog Blind hollow shaft ø12 mm Magnetic single- or multiturn encoders 12 bit ST / 16 bit MT

Product Information. EQN 1337 F Absolute Rotary Encoder with Tapered Shaft for Fanuc Controls with i Interface

Universal MEMS Inclination Sensor with Analog Output. Output /Excitation U6 U8 I1

Absolute encoders - SSI Solid shaft with clamping or synchro flange Optical multiturn encoders up to 14 bit ST / 16 bit MT

POSICHRON position sensor in a stainless steel pressure case. Voltage: V, 3 wire Current: ma, 3 wire

Temposonics. Magnetostrictive Linear Position Sensors. ER SSI Data Sheet

Featuring a 100 μs sampling period and ±0.1% linearity

Technical Description and User Manual E-band CW power meter DPM-12 s/n N-1204/21-T

Online data sheet. ACM60B-S1KE13x06 ACM60 ABSOLUTE ENCODERS

METERSUK. SmartLink D Y N A M i T E. EM415 MOD Series. User Manual KEY FEATURES INDEX 3. TECHNICAL DESCRIPTION. Single Phase Metering

Extremely robust Inclination Sensor with Analog Output U8 I1. Measurement range ±180 for 1 axis or ±60 for 2 axes

Incremental encoders Blind or through hollow shaft ø12 mm pulses per revolution

ACTUATOR LA36 PRODUCT DATA SHEET

Protocol and instruction set for remote control via the infrared interface. Table of Contents

HUMIDITY/TEMP. CONTROLLER/MONITOR

Select datum Page backward in. parameter list

NOVOSTRICTIVE Transducer up to 4250 mm touchless. Series TH1

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver

SSI Inclinometer. Zigbee. CDMA Vibration-wire. SSI PWM Switch Analog. Features. Descriptions

IXARC Incremental Encoder UCD-IPT M100-PRD. Interface Programmable Incremental. Configuration Tool UBIFAST Configuration Tool (Version 1.6.

Multiturn absolute encoder

Select datum Page backward in parameter list

Controller for the Implementation of a Central or Decentralized Electrohydraulic System

Technical data. General specifications. Linearity error ± 0.1 Functional safety related parameters MTTF d 700 a at 40 C Mission Time (T M ) L 10

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

This kind of information is useful to make reliable automatic control diagnostic and supervision systems. IS VS. Diameter of cylindrical types

Operation. Displayed channel. Measuring range. Status indication/ remote control Key lock Measuring mode/ time constant. Scale.

Magnetic Linear Measuring System. MS01 Technical manual

PowerPlex Compact Module PP-C-COM24

2F. No.25, Industry E. 9 th Rd., Science-Based Industrial Park, Hsinchu, Taiwan Application Note of OGM220, AN001 V1.8

Transcription:

Main Features - Two axis digital inclinometer - Angle measurement range of +/-5, +/-15 and +/-30, Resolution up to 0.001 - Interface: RS232, Code: ASCII, Switch Open Collector - Housing: 70 mm Programmable Parameters - Transmission mode: Polled Mode, Cyclic Mode - Cycle Time - Setting of zero point - Baudrate 2.4 up to 56 KBaud Applications - Structural engineering - Leveling techniques - Measuring techniques - Inclinations - Mechanical Structure Electrical Features - Linear and temperature compensated characteristic line - Microprocessor controlled - Polarity inversion protection - Over-voltage-peak protection - Highly integrated circuit in SMD-technology

1 Technical Data 1.1 Electrical Data Model INC 5 INC 15 INC 30 Measuring range +/- 5 +/- 15 +/- 30 Resolution digital 0.001 0.001 0.01 Resolution switch 0,1 0,1 0,1 Accuracy switch +/-0,1 +/-0,1 +/-0,1 Accuracy digital 1) +/-0,01 +/-0,01 +/-0,02 Temperture Gradient 2) +0.001 /K +0.002 /K +0.003 /K Inclination angle in x and y 1) +/-15 +/-40 +/-60 Damping period 5 > 0 Typical 1 s 10 %, 2 s 1 %, 3 s 0.1% Digital interface Baud rate Switch Supply voltage 4) Current consumption RS232 format ASCII Max. 56 k 0,1 -Step switch SGND, 50mA (Open Collector) to Uext (x,y) 10 to 30 V DC (absolute limits) Typical 50 ma EMC Emitted interference: EN 61000-6-3 Noise immunity: EN 61000-6-2 Electrical lifetime > 10 5 h 1) T = +25 C, 90% total measurement range 2) e.g. temperature drift AGS005 (T= 0 C to +55 C) = 55K * 0,001 /K = 0,055 3) Supply voltage is applied. 4) Inclinometers should be connected only to subsequent electronics whose power supplies comply with EN 50178 (protective low voltage) Page 2 Inclinometer RS232 Switch Datasheet Version: 20130503

1.2 Mechanical Data Housing Lifetime Aluminum > 10 5 h Shock A=30 g ; t= 11 ms, halfsine ; EN 60068-2-27 Vibration Weight (standard version) 10 to 150 Hz, 2,5 mm amplitude, 5 g const. Acceleration, 1 Octave /Minute ; EN 60068-2-6 350 g 1.3 Environmental Conditions Operating/ Storage temperature Humidity -40 to +85 C 98 % (without liquid state) Protection class IP 67 (connected); EN 60529 Page 3 Inclinometer RS232 Switch Datasheet Version: 20130503

2 Installation 2.1 Electrical Connection The inclinometer is connected via 8 pin round connector or a cable 2.2 Connector Assignment Pin Description P8F-Cable CRW-Cable 1 +UB Supply voltage white white 2 RxD brown brown 3 TxD green green 4 Ground (Supply) yellow yellow 5 X-Output grey grey 6 S-Ground pink pink 7 Y-Output blue red Front view of housing Connector inclinometer 8 red Output signal (X, Y) switch, 0.1 step Installation Instructions Do not connect the inclinometer under power! Do not stand on the inclinometer! Avoid mechanical load! Page 4 Inclinometer RS232 Switch Datasheet Version: 20130503

3 Mechanical Drawings Dimension Housing (mm) Page 5 Inclinometer RS232 Switch Datasheet Version: 20130503

4 Reference Level The Inclinometer has a mounting reference angle (black line) for an optimal mounting, which is parallel to the x-axis. This reference angle must be placed exactly parallel to the object to be measured, to prevent or minimize any mechanical offset/cross sensitivity. Reference edge, base plate side Reference angle of the inclinometer, top view. Page 6 Inclinometer RS232 Switch Datasheet Version: 20130503

5 Mounting and Installation Instruction The inclinometer is designed for a horizontal mounting, i.e. the base plate of the inclinometer with the three mounting holes needs to be placed on the horizontal plane of the object to be measured. It can be mounted with M4 screw or smaller. The mounting surface must be plane and free of dust and grease. We recommend cheese head screws with metrical thread M4for the mounting. Maximum fastening torque for the mounting screws is 10 Nm. 5.1 Installation Prior to installation, please check for all connection and mounting instructions to be complied with. Please also observe the general rules and regulations on low voltage technical devices. Avoid shock and vibration during installation, as these could corrupt the measurement results. Inclination sensors that base on a fluidic measurement principle are optimal for static measurements and suitable to only a limited extent of dynamic measurement. 5.2 Measurement The measurement of the tilt angle of the single measurement axis is carried out over the respective longitudinal and lateral axis of the inclination sensor. Reference is always the horizontal plane. View of male socket Side view - y Lateral axis + y - x + x Longitudinal axis Page 7 Inclinometer RS232 Switch Datasheet Version: 20130503

6 Models/Ordering Description Description Type Key Absolute Inclinometer INC- _ -2-S _ 1-H0- _ Measuring range 005 015 030 Number of axis RS232 without Interface Volltage interface Current interface PWM Switch O V C P S Version Mounting Dynamic Connection Horizontal 2 m Pas plug, 8 pins 1 m cable exit P8M CRW Optionen Page 8 Inclinometer RS232 Switch Datasheet Version: 20130503

7 Serial Interface RS 232 Communication with the sensor is done through a standardized RS-232 interface. Data transmission is effected in duplex mode. The baud rate is fixed by 9600 baud. After Power On the sensor is sending continuous the angle values in degrees ( ). In the setup level several settings can be permanently modified. If the continuous mode was permanently changed to the polling mode, the sensor will send after Power On a start information with actual parameters. On error no angle values are sending and after Power On an error message was add to the start information. Page 9 Inclinometer RS232 Switch Datasheet Version: 20130503

8 Programming Instructions 8.1 Basic Settings After Power On, the sensor is in the user level. In factory setting (=Free running mode) every 100ms the current angle values are continuously supplied with a baud rate of 9600 bd. In the Setup-level several settings can be changed permanently such as query or free running mode, output rate, baud rate and angle offset. If query mode instead of free running mode is selected, the sensor will send start information with the current settings after Power On. In case of errors no angle values will be provided and after Power On and an error message will be added to the start information. 8.2 Interface parameter - 9600 Baud, 8 data bits, parity even, 1 stop bit, The baud rate can be adjusted to different values in the Setup-level. Structure: Baud rate: 9600 Baud (factory setting, changes in Setup-Mode possible) Format ASCII, 8 data bits, 1 stop bit, parity even Length: 22 byte Display: <D0... D21> D0... D10 = X=±xx.xxx, <CR>, <LF> mit D2 = sign (+ or -) mit D5 = point D11... D21 = Y=±xx.xxx, <CR>, <LF> with D13 = sign (+ or -) with D16 = point Display Example: X=+00.430 Y=-00.084 Page 10 Inclinometer RS232 Switch Datasheet Version: 20130503

9 Commands in User Level Instruction To the Response sensor Description sensor activate temporary polling mode f f the continuous sending of angle values are stopped, instructions can send to the sensor activate temporary continuous mode F X=vxx.xxx, CR, LF, Y=vxx.xxx, CR, LF, X=... X angle in Y angle in with ± = + or -, one string contains x and y value read angle values at one-time R X=vxx.xxx, CR, LF, Y=vxx.xxx, CR, LF, X angle in Y angle in with ± = + or - switch to the setup level 3) 4) prog P Sensor is at setup level show active level * Ux or Sx U means Sensor is at User level S means Setup-level is active, with x Output-Mode of Sensors U / I / P / S 1) In free running mode measurement data is continuously displayed. In query mode measurement and display is only once on command. 2) After reset or new Power On after an interruption of power supply, the sensor will be in user-level again with the original setup or with the setup changed in the setup level. 3) Only possible in query mode (=free running mode deactivated). 4) The Input of prog must take place within 20 sec. Page 11 Inclinometer RS232 Switch Datasheet Version: 20130503

10 Setup Level The Setup level is active until Power On or Reset. All settings taken in the setup level are stored in the EEPROM and permanent available also after Power down. Instruction To the sensor Response sensor Description activate permanent f f the continuous sending of polling mode 1) angle values are permanent stopped, instructions can send to the sensor activate permanent continuous mode 1) F X=±xx.xxx, CR, LF, continuous sending of X angle in Y=±xx.xxx, CR, LF, Y angle in X=... with ± = + or - set rate of data O O Echo, transmission for <Code transmission <Code transmission Code transmission rate 2) 3) 4) continuous mode rate> rate> or E for Error, if the code is outside defined values read angle values at R same as at user level one-time 2) read version 2) V AGSxxx-2-Sx, CR, LF SN:xxxx-xxx, CR, LF HV:xx.x, CR, LF SV:xx.x, CR, LF type of Sensor serial number HW Version internal sensor SW Version offset adjust of the specified axis 2) 3) n x or y n OffsetX=±xx.xxx or the actual angle of specified axis is set to OffsetY=±xx.xxx zero, ±xx.xxx is the internal offset in degree reset offset adjust 2) 3) N N the offset adjust was reset to the original value 2) 3) 6) Set Baud rate B B Echo, Code Baud rate or <Code Baud rate> <Code Baud rate> E for Error, if the code is outside defined values Filter deactivated M0 M0 all filters are deactivated Moving Average M1, mm M1mm Filter: Moving Average Filter 10) Filter is activated Page 12 Inclinometer RS232 Switch Datasheet Version: 20130503

Exponential Filter 10) M2, tt M2tt Filter: Exponential Filter is activated Set switch angle for Sx 2) 3) 7) 8) one axis <switch angle> or Sy Sx or Sy <switch angle> Echo, switch angle or E for Error, if the angle is <switch angle> outside admissible range Set hysteresis for Sh Sh Echo, hysteresis or E switching point in both <hysteresis> <hysteresis> for Error, if the angle is 2) 3) 7) 9) axis outside admissible range show active level 2) * same as at user level Reset 2) q q Software-Reset will be executed 1) in the continuous mode the sensor is sending continuous angle values, in the polling mode the sensor is sending one answer after an instruction 2) only possible at polling mode. 3) for activating a reset or power fail restart is necessary 4) for Code transmission rate see 5) Table 1 <Code transmission rate> 6) for Code baud rate see Erreur! Source du renvoi introuvable. Attention! A reset of the baud rate to a default value is not possible. If the user forgets the adjusted baud rate, the new value must be detected by testing. 7) this instruction is only effectual at sensors with switch output, 8) <switch angle>: three digits from 001 until 300 for the angle in tenths of a degree, max working range of the sensor. Default value is 025 == 2,5 9) <hysterese>: two digits from 01 until 99 for the stitching hysterese in tenths of a degree, max working range of the sensor, Default value is 01 = 0,1 10) Formulas for Filter : - Moving Average Filter M1, mm (possible values mm = 02 to 40, with mm = 00 is moving average filter deactivated): Output value = Average over last mm values. - Exponential Filter M2, tt (first order low pass filter, possible values tt = 02 to 40, with tt = 00 is exponential filter deactivated): Output value = ( old output value * (tt-1) / tt ) + (value / tt ) Page 13 Inclinometer RS232 Switch Datasheet Version: 20130503

<Code transmission rate> <Code transmission rate> Strings per second, 1 string contains x and y-value 0 reserved 1 25 Strings/s 1) 2 10 Strings/s, Default value 2) 3 5 Strings/s 4 2 Strings/s 5 1 Strings/s 6 0,2 Strings/s 7 0,1 Strings/s 8, 9 not defined 1) only allowed with baud rate of at least 9600 Bd 2) only allowed with baud rate of at least 4800 Bd <Code Baud Rate> <Code Baud Rate> Baud rate 0 2400 Baud 1 4800 Baud 2 9600 Baud, Default value 3 19200 Baud 4 38400 Baud 5 57600 Baud 6, 7, 8, 9 not defined Page 14 Inclinometer RS232 Switch Datasheet Version: 20130503

Example for Setting the Output Rate Instruction To the sensor Response sensor Description X=±xx.xxx, CR, LF, Y=±xx.xxx, CR, LF, X=... continuous sending of angles activate temporary polling mode switch to the setup level set rate of data transmission for continuous mode f f the continuous sending of angle values are stopped, instructions can send to the sensor prog P Sensor is at setup level O5 O5 Code transmission rate is set to 1Strings/s Reset q q Software-Reset will be executed, the new settings are guilty X=±xx.xxx, CR, LF, Y=±xx.xxx, CR, LF, X=... continuous sending of angles at 1 Strings/s We do not assume responsibility for technical inaccuracies or omissions. Specifications are subject to change without notice. Page 15 Inclinometer RS232 Switch Datasheet Version: 20130503