Establishing Traceability to UTC

Similar documents
Metrological and legal traceability of time signals

Recent Calibrations of UTC(NIST) - UTC(USNO)

Time Traceability for the Finance Sector Fact Sheet

Evaluation of timing GPS receivers for industrial applications

HOW TO RECEIVE UTC AND HOW TO PROVE ACCURACY

Traceability measurement results of accurate time and frequency in Bosnia and Herzegovina

TIME AND FREQUENCY ACTIVITIES AT THE CSIR NATIONAL METROLOGY LABORATORY

Time and Frequency Laboratory Measurement Units, Standards. (National Metrology Institute) MUSSD-Sri Lanka

TECHNICAL PAPERS. Michael A. Lombardi

CURRENT ACTIVITIES OF THE NATIONAL STANDARD TIME AND FREQUENCY LABORATORY OF THE TELECOMMUNICATION LABORATORIES, CHT TELECOM CO., LTD.

Today's Lecture. Clocks in a Distributed System. Last Lecture RPC Important Lessons. Need for time synchronization. Time synchronization techniques

Influence of GPS Measurements Quality to NTP Time-Keeping

Traceability in Time and Frequency Metrology

Precise Time Transfer Concepts

Wide-Area Time Distribution with PTP Using Commercial Telecom Optical Fiber

Remote Time Calibrations via the NIST Time Measurement and Analysis Service

Pendulum Instruments AB Sorterargatan 26 SE VÄLLINGBY SWEDEN

Characterizing the Performance of GPS Disciplined Oscillators with Respect to UTC(NIST)

COMPARISON OF THE ONE-WAY AND COMMON- VIEW GPS MEASUREMENT TECHNIQUES USING A KNOWN FREQUENCY OFFSET*

STATUS REPORT OF TIME AND FREQUENCY LAB. (VIETNAM METROLOGY INSTITUTE)

GPS and the Legal Traceability of Time

SyncServer S650 Accurate, Secure, and Flexible Time and Frequency Standard

NMI's Role and Expertise in Synchronization Applications

The Timing Group Delay (TGD) Correction and GPS Timing Biases

Timing & Synchronisation

Specific Accreditation Criteria Calibration ISO/IEC Annex. Electrical metrology

Dynamic Two-Way Time Transfer to Moving Platforms W H I T E PA P E R

ESTIMATING THE RECEIVER DELAY FOR IONOSPHERE-FREE CODE (P3) GPS TIME TRANSFER

REPORT OF TIME AND FREQUENCY LABORATORY (VIETNAM METROLOGY INSTITUTE)

A New Class of Precision UTC and Frequency Reference Using IS-95 CDMA Base Station Transmissions

CS649 Sensor Networks IP Lecture 9: Synchronization

Clock Synchronization

Rapid UTC: a step forward for enhancing GNSS system times Elisa Felicitas Arias

Timing in Mission-Critical Systems

REPORT OF TIME AND FREQUENCY LABORATORY (VIETNAM METROLOGY INSTITUTE)

AVERAGING SATELLITE TIMING DATA FOR NATIONAL AND INTERNATIONAL TIME COORDINATION

Correct Measurement of Timing and Synchronisation Signals - A Comprehensive Guide

Time and Frequency Laboratory Measurement Units, Standards and Services Department (National Metrology Institute) MUSSD- Sri Lanka

SyncServer S650 Accurate, Secure, and Flexible Time and Frequency Standard

STEERING UTC (AOS) AND UTC (PL) BY TA (PL)

F6052 Universal Time Synchronizer

Distributed Systems. Time Synchronization

PRECISE RECEIVER CLOCK OFFSET ESTIMATIONS ACCORDING TO EACH GLOBAL NAVIGATION SATELLITE SYSTEMS (GNSS) TIMESCALES

Clock Synchronization

Measuring Time Error. Tommy Cook, CEO.

THE TIME DISTRIBUTION SYSTEM FOR THE WIDE AREA AUGMENTATION SYSTEM (WAAS)

Power Matters. Time Interfaces. Adam Wertheimer Applications Engineer. 03 November Microsemi Corporation.

Overview of Frequency Measurements and Calibration

Time and Frequency Distribution Overview and Issues Rob Selina

TIME COORDINATION THROUGHOUT THE AMERICAS VIA THE SIM COMMON-VIEW GPS NETWORK

Time Distribution for Application Level 2 and 3 Linking Protection

Critical Evaluation of the Motorola M12+ GPS Timing Receiver vs. the Master Clock at the United States Naval Observatory, Washington DC.

Evaluation of performance of GPS controlled rubidium clocks

MINOS Timing and GPS Precise Point Positioning

RECENT TIMING ACTIVITIES AT THE U.S. NAVAL RESEARCH LABORATORY

T200, PTP/IEEE 1588 Grandmaster Clock and

Feasibility Studies of Time Synchronization Using GNSS Receivers in Vehicle to Vehicle Communications. Queensland University of Technology

ONE-WAY GPS TIME TRANSFER 2000

MISCELLANEOUS CORRECTIONS TO THE BASELINE DESIGN

CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF TIME AND FREQUENCY METROLOGY

BIPM TIME ACTIVITIES UPDATE

Global Navigation Satellite System for IE 5000

THE OPEN TRACEABLE TIME PLATFORM AND ITS APPLICATION IN FINANCE AND TELECOMMUNICATIONS. Michael J. Wouters. National Measurement Institute, Australia

UTC DISSEMINATION TO THE REAL-TIME USER

TIME TRANSFER BETWEEN USNO AND PTB: OPERATION AND CALIBRATION RESULTS

THE DEVELOPMENT OF MULTI-CHANNEL GPS RECEIVERS AT THE CSIR - NATIONAL METROLOGY LABORATORY

Timing over packet networks

Nov.6-7,2014 DEC Workshop on Participation in Coordinated Universal Time. Aimin Zhang National Institute of Metrology (NIM)

ITU-T G.8272/Y.1367 (01/2015) Timing characteristics of primary reference time clocks

The Nanokernel. David L. Mills University of Delaware 2-Aug-04 1

FAST DIRECT-P(Y) GPS SIGNAL ACQUISITION USING A SPECIAL PORTABLE CLOCK

Digital Instruments S.r.l. GPS-MXS. Multireference Time-Frequency

LONG-BASELINE COMPARISONS OF THE BRAZILIAN NATIONAL TIME SCALE TO UTC (NIST) USING NEAR REAL-TIME AND POSTPROCESSED SOLUTIONS

Power Utilities Mitigating GPS Vulnerabilities and Protecting Power Utility Network Timing

The Future of the Leap Second

GPS DISCIPLINED OSCILLATORS FOR TRACEABILITY TO THE ITALIAN TIME STANDARD

Measurements and Distribution: PNT and Other Applications

GPS & other Radio Time sources

RECENT ACTIVITIES IN THE FIELD OF TIME AND FREQUENCY IN POLAND

Time transfer over a White Rabbit network

The Inter-American Metrology System (SIM) Common-View GPS Comparison Network

STABILITY AND ERROR ANALYSIS FOR ABSOLUTELY CALIBRATED GEODETIC GPS RECEIVERS

Providing a Resilient Timing and UTC Service Using eloran in the United States. Charles Schue - ION PTTI Monterey, CA

National time scale UTC(SU) and GLONASS system time scale: current status and perspectives

LOCKING A RUBIDIUM OSCILLATOR TO A REMOTE TIME SCALE USING REAL-TIME COMMON-VIEW GPS MEASUREMENTS

Haruo Saito. National Institute of Information and Communications Technology

Remote Frequency Calibration Service at NMIJ

STABILITY OF GEODETIC GPS TIME LINKS AND THEIR COMPARISON TO TWO-WAY TIME TRANSFER

Design of Simulcast Paging Systems using the Infostream Cypher. Document Number Revsion B 2005 Infostream Pty Ltd. All rights reserved

ITSF 2017 It is time for time It Is Time For Time PTP/NTP/IRIG Time Server w/ RFC3161 TimeStamping

The Inter-American Metrology System (SIM) Common-View GPS Comparison Network

TIME AND FREQUENCY TRANSFER ACTIVITIES AT NIST

Your benefits using DTS 4160.grandmaster:

Modelling GPS Observables for Time Transfer

THE STABILITY OF GPS CARRIER-PHASE RECEIVERS

IMPROVING THE PERFORMANCE OF LOW COST GPS TIMING RECEIVERS

Fundamentals of Precision Time Protocol. Rudy Klecka Cisco Systems. October 14, 2015

GPS Carrier-Phase Time Transfer Boundary Discontinuity Investigation

On Optimizing the Configuration of Time-Transfer Links Used to Generate TAI. *Electronic Address:

PERFECT TIMING CRAIG PREUSS, P.E. HOW IEEE STANDARD PC IMPACTS SUBSTATION AUTOMATION

Transcription:

White Paper W H I T E P A P E R Establishing Traceability to UTC "Smarter Timing Solutions" This paper will show that the NTP and PTP timestamps from EndRun Technologies Network Time Servers are traceable through the National Institute of Standards and Technologies (NIST), and the United States Naval Observatory (USNO) to Coordinated Universal Time (UTC) maintained by the International Bureau of Weights and Measures (BIPM). WHAT IS TRACEABILITY? Metrology is the science of measurement. Calibration is a comparison between measurements, with one measurement being of known correctness called the reference (or standard). Traceability refers to an unbroken chain of calibrations relating an instrument s measurements to a known reference. It is important to note that traceability is the property of a measurement result, not of an instrument. The official definition of traceability is contained in the International Vocabulary of Metrology - Basic and General Concepts and Associated Terms (VIM; 2008): Metrological Traceability: property of a measurement result whereby the result can be related to a reference through a documented unbroken chain of calibrations, each contributing to the measurement uncertainty. In other words, traceability is the property of a measurement result, such as an NTP or PTP timestamp, whereby the result can be related to a reference, such as UTC(NIST), through an unbroken chain of comparisons, all having stated uncertainties. This paper will document the unbroken chain of comparisons from the point of the NTP/PTP timestamp measurement back to UTC. Each link in the chain has an associated uncertainty which is composed of time offset and jitter. The uncertainty of the entire traceability chain is typically computed as the square root of the sum of the squares of the individual uncertainties. This means that the largest uncertainty tends to dominate the result. Improving links in the traceability chain with small uncertainties has a minimal effect on the overall result. NOTE: An uncertainty is another way of stating accuracy. For example, a timestamp that is traceable to UTC with an uncertainty of 100 nanoseconds means that the timestamp is accurate to UTC to within 100 nanoseconds. METROLOGICAL AND LEGAL TRACEABILITY Metrological traceability in the VIM (above) is the only type of traceability defined in an international standards document. Metrological traceability requires measurements and uncertainty calculations. The numbers in this paper satisfy this requirement up to the point of the NTP/PTP timestamps generated by the Time Server. You will need to continue the traceability chain up to the point of the timestamps generated by your workstations. Legal traceability means that you must be prepared to convince a jury in an adversarial proceeding that your time was correct at some instant in the past. The exact amount of evidence required to prove traceability in a court of law varies from case to case. If you have established metrological traceability for a given time period, then you have also established legal traceability for that time period. To prove this in court some recordkeeping, such as log files, is essential. The question of how extensive your policies and procedures need to be in order to prove traceability must be decided based on your specific requirements and is beyond the scope of this paper.

GPS-SYNCHRONIZED NETWORK TIME SERVERS The UTC traceability chain for NTP/PTP timestamps using the Global Positioning System (GPS) is shown in Figure 1 and Table 1. NTP Time Server PTP Grandmaster NTP Client BIPM (Interna onal Bureau of Weights and Measures) Figure 1. GPS-Synchronized Network Time Server UTC Traceability Chain

Table 1. GPS-Synchronized Network Time Server Traceability Chain Link Reference Compared To Uncertainty A UTC per BIPM Circular-T UTC(NIST or USNO) < 10 nanoseconds B UTC(NIST or USNO) GPS Satellite Transmissions < 10 nanoseconds C GPS Satellite Transmissions GPS Receiver Inside Network Time Server < 30 nanoseconds D GPS Receiver Inside Network Time Server NTP Server Timestamps < 10 microseconds* PTP Grandmaster Timestamps < 8 nanoseconds* E Network Time Server NTP/PTP Timestamps NTP Client < 2 milliseconds (LAN) < 100 nanoseconds (LAN) *This chain shows that the NTP/PTP timestamps generated by an EndRun GPS-synchronized Time Server are traceable to UTC. The overall uncertainty is computed as the square root of the sum of the squares of the individual uncertainties. In this case, the overall uncertainty is 10 microseconds for NTP and 34 nanoseconds for PTP timestamps applied by the Time Server and Grandmaster. The uncertainty of application-level timestamps is based on a typical time transfer uncertainty (2 milliseconds for NTP and 100 nanoseconds for PTP), the Client/Slave clock quality and respective operating system latencies. Uncertainties of the Transmitted and Received GPS Signal BIPM calculates the international unit for time (SI second) by averaging clock data from over 70 international timing laboratories that collectively form the UTC timescale. BIPM generates UTC only on paper, however, through a monthly publication called the Circular-T. The international timing laboratories maintain physical, real-time versions of UTC that are constantly steered to agree to UTC per the Circular-T report. For example, NIST generates UTC(NIST) and USNO generates UTC(USNO), and both timescales agree within nanoseconds of BIPM s UTC computations. The uncertainty introduced by Link A is less than 10 nanoseconds. The time component of GPS is directly referenced to the USNO timescale that automatically establishes traceability to UTC(USNO). NIST continually measures signals from the GPS constellation and compares it to UTC(NIST) that establishes traceability to NIST. The resulting data (the uncertainties) are then published and made available to end users after the fact. The uncertainty introduced by Link B is also less than 10 nanoseconds. Link C is GPS receiver dependent. The GPS receiver resident in an EndRun Sonoma Time Server adds less than 30 nanoseconds of uncertainty to the chain. EndRun s Meridian II Precision TimeBase has a calibrated GPS timing receiver that adds less than 10 nanoseconds of uncertainty. Links A, B and C encompass the entire GPS transmitted and received signal. In NTP applications, the uncertainty of the GPS transmitted signal is insignificant because uncertainties introduced by your computer network are much larger. In PTP applications, the GPS uncertainty is more significant as the network uncertainties are minimized. Uncertainties of Timestamp Measurements Link D is the uncertainty introduced by the NTP and PTP timestamp mechanism inside the Time Server. The Sonoma s embedded operating system minimizes the internal latencies for NTP timestamps to less than 10 microseconds. Hardware-based PTP timestamping eliminates operating system latencies resulting in only 8 nanoseconds of uncertainty. Continuing the Traceability Chain... Link E represents uncertainties due to delays in your network environment. The link is composed of the workstation s NTP Client or timestamping NTP or PTP packets sent to and received from the Time Server, packet processing, clock synchronization, and ultimately generating application-level transaction timestamps. For NTP, this link represents the largest uncertainty in the traceability chain (typically ½ to 2 milliseconds). For more complex and wide area networks (WANS) uncertainties of several tens of milliseconds or more are possible. The hardware-based PTP protocol operating in a network with PTP-aware elements (i.e. transparent and/or boundary clocks), significantly reduces the uncertainty (typically 100 nanoseconds within a LAN). (For an overview of how your network configuration will affect the accuracy of the NTP timestamps generated by your workstations read the White Paper at www.endruntechnologies.com/pdf/ntp-intro.pdf.)

CDMA-SYNCHRONIZED NETWORK TIME SERVERS The CDMA cell phone system basically acts as a repeater of GPS timing information. To establish UTC traceability for CDMA Network Time Servers, two links are inserted into the GPS traceability chain as shown in Figure 2 and Table 2. NTP Client NTP Time Server PTP Grandmaster BIPM (Interna onal Bureau of Weights and Measures) Figure 2. CDMA-Synchronized Network Time Server UTC Traceability Chain

Table 2. CDMA-Synchronized Network Time Server Traceability Chain Link Reference Compared To Uncertainty (Stated) A UTC per BIPM Circular-T UTC(NIST or USNO) < 10 nanoseconds B UTC(NIST or USNO) GPS Time from Satellite Transmissions < 10 nanoseconds C GPS Time from Satellite Transmissions GPS Receiver at CDMA Base Station < 100 nanoseconds D GPS Receiver at CDMA Base Station CDMA Base Station Transmissions < 1 microsecond < 10 us worst-case E CDMA Base Station Transmissions CDMA Receiver Inside Network Time Server < 10 microseconds < 101 us worst-case F CDMA Receiver Inside Network Time Server NTP Server Timestamps < 10 microseconds* PTP Grandmaster Timestamps < 8 nanoseconds* G Network Time Server NTP/PTP Timestamps NTP Client < 2 milliseconds (LAN) < 100 nanoseconds (LAN) *This traceability chain shows that NTP/PTP timestamps generated by an EndRun CDMA-Synchronized Time Server are traceable to UTC managed by BIPM. The overall uncertainty is computed as the square root of the sum of the squares of the individual uncertainties. In this case the overall uncertainty is 14 microseconds for NTP and 10 microseconds for PTP timestamps generated by the Time Server and Grandmaster. This uncertainty number will degrade up to 101 microseconds for rural locations. The uncertainty of application-level timestamps is based on the time transfer uncertainty (2 milliseconds for NTP and 100 nanoseconds for PTP), the Client/Slave clock quality and respective operating system latencies. Uncertainties of the Transmitted GPS Signal The uncertainties introduced by Links A and B are detailed in the section on GPS Network Time Servers. In NTP applications, the uncertainty of the GPS transmitted signal is insignificant because uncertainties introduced by your computer network are much larger. In PTP applications, the GPS uncertainty is more significant as the network uncertainties are minimized. Uncertainties of the Received GPS Signal and the Transmitted CDMA Signal Link C is GPS receiver-dependent. Each CDMA base station has a GPS receiver that maintains the time for the CDMA cellular system and acts as a repeater of GPS time. The GPS receivers at these base stations are usually high quality, redundant, and have high performance OCXO or atomic (rubidium) oscillators. The worst-case uncertainty for a receiver such as this is 100 nanoseconds. The CDMA specification ANSI/TIA/EIA-95-B states in Section 1.2 CDMA System Time: All base station digital transmissions are referenced to a common CDMA system-wide time scale that uses the Global Positioning System (GPS) time scale, which is traceable to and synchronous with Coordinated Universal Time (UTC). The CDMA specification mandates that the accuracy of each base station s time be within +/- 10 microseconds of GPS time, even during periods of GPS unavailability up to 24 hours. Such GPS outages could arise from damage to the antenna/cable or signal interference and would be considered relatively rare events. If the GPS receiver were to become unsynchronized it would drift away from perfect time very slowly. Once it got to over 10 microseconds, the base station would be taken off-line as it would cause problems for the overall cellular phone system. Therefore, the uncertainty of the CDMA transmitted signal is 10 microseconds (Link D). Uncertainty of CDMA Received Signal at End User s Site The CDMA Time Server is synchronous with the CDMA base station transmission from one to tens of microseconds, depending on location. Location is not a factor with the GPS Time Servers because the internal GPS receiver determines its position based on signals received from multiple GPS satellites. The CDMA Receiver does not know its position relative to the CDMA base station so Link E is the uncertainty due to the unknown distance of the Time Server from the base station. There is a propagation delay of about 5 microseconds per mile when receiving the CDMA cell phone signal. In urban environments there are many base stations packed closely together so most end users will be within a mile and 5 microseconds of the transmitted signal time.

EndRun specifies the accuracy of its CDMA receiver to be within 10 microseconds of UTC when locked (typical). This assumes the CDMA receiver is within 2 miles of a base station, which is true in the majority of cases. In suburban or rural areas the base stations are spaced further apart so the propagation delay increases and receiver accuracy degrades. At our suburban test facility the CDMA receiver is synchronous within 20 microseconds of UTC. Our rural facility is within 90 microseconds of UTC as the base station is nearly 18 miles away. Uncertainties of NTP Timestamp Measurements Link F is the uncertainty introduced by the NTP and PTP timestamp mechanism inside the Time Server. The EndRun Sonoma s embedded operating system minimizes the internal latencies for NTP timestamps to less than 10 microseconds. Hardware-based PTP timestamping eliminates operating system latencies resulting in only 8 nanoseconds of uncertainty. Continuing the Traceability Chain... Link G represents uncertainties due to delays in your network environment. The link is composed of the workstation s NTP Client or timestamping NTP or PTP packets sent to and received from the Time Server, packet processing, clock synchronization, and ultimately generating application-level transaction timestamps. For NTP, this link represents the largest uncertainty in the traceability chain (typically ½ to 2 milliseconds). For more complex and wide area networks (WANS), uncertainties of several tens of milliseconds or more are possible. The hardware-based PTP protocol operating in a network with PTP-aware elements (i.e. transparent and/or boundary clocks), significantly reduces the uncertainty (typically 100 nanoseconds within a LAN). (For an overview of how your network configuration will affect the accuracy of the NTP timestamps generated by your workstations read the White Paper at www.endruntechnologies.com/pdf/ntp-intro.pdf.) SUMMARY The NTP and PTP timestamps generated by the EndRun Technologies GPS and CDMA Time Servers are traceable through NIST and USNO to the UTC timescale managed by BIPM. The uncertainties inherent in both the GPS and CDMA traceability chains, up to the point of the NTP timestamps, are negligible when compared with the final link in the chain - the uncertainty introduced by your network environment. For PTP, the uncertainties in the GPS and CDMA traceability chains, up to the point of the PTP timestamps, are more significant as the uncertainty of the network environment is much smaller. REFERENCES Michael A. Lombardi, Traceability in Time and Frequency Metrology, Cal. Lab. Int. J. Metrology, Sept-Oct 1999, pp. 33-40. Michael A. Lombardi, Lisa M. Nelson, Andrew N. Novick, Victor S. Zhang, Time and Frequency Measurements Using the Global Positioning System, Cal. Lab. Int. J. Metrology, July-Aug 2001, pp. 26-33. Judah Levine, Michael A. Lombardi, and Andrew N. Novick, NIST Computer Time Services, NIST Special Publication 250-59, May 2002. Judah Levine, NTP Newsgroup at comp.protocols.time.ntp, Re: Demonstrate Traceability to UTC 3/13/2009 and 3/16/2009. "Smarter Timing Solutions" Santa Rosa, CA, USA TEL 1-877-749-3878 FAX 707-573-8619 www.endruntechnologies.com 170612