arxiv: v1 [gr-qc] 10 Sep 2007

Similar documents
Thermal correction of the radii of curvature of mirrors for GEO 600

Experience with Signal- Recycling in GEO600

Arm Cavity Finesse for Advanced LIGO

The Florida control scheme. Guido Mueller, Tom Delker, David Reitze, D. B. Tanner

Interferometer for LCGT 1st Korea Japan Workshop on Korea University Jan. 13, 2012 Seiji Kawamura (ICRR, Univ. of Tokyo)

Advanced Virgo commissioning challenges. Julia Casanueva on behalf of the Virgo collaboration

Koji Arai / Stan Whitcomb LIGO Laboratory / Caltech. LIGO-G v1

5 Advanced Virgo: interferometer configuration

Alignment control of GEO 600

Received 14 May 2008, in final form 14 July 2008 Published 11 September 2008 Online at stacks.iop.org/cqg/25/195008

How to Build a Gravitational Wave Detector. Sean Leavey

Lateral input-optic displacement in a diffractive Fabry-Perot cavity

Comparison of tuned and detuned Signal-Recycling. Stefan Hild for the GEO-team

Length sensing and control of a Michelson interferometer with power recycling and twin signal recycling cavities

Installation and Characterization of the Advanced LIGO 200 Watt PSL

7th Edoardo Amaldi Conference on Gravitational Waves (Amaldi7)

Interferometer signal detection system for the VIRGO experiment. VIRGO collaboration

Results from the Stanford 10 m Sagnac interferometer

Michelson interferometer with diffractively-coupled arm resonators in second-order Littrow configuration

Advanced LIGO optical configuration investigated in 40meter prototype

Measurement of optical response of a detuned resonant sideband extraction gravitational wave detector

The Virgo detector. L. Rolland LAPP-Annecy GraSPA summer school L. Rolland GraSPA2013 Annecy le Vieux

Experimental Test of an Alignment Sensing Scheme for a Gravitational-wave Interferometer

Introduction to laser interferometric gravitational wave telescope

Gingin High Optical Power Test Facility

Optical Vernier Technique for Measuring the Lengths of LIGO Fabry-Perot Resonators

Commissioning of Advanced Virgo

Alignment signal extraction of the optically degenerate RSE interferometer using the wave front sensing technique

Stable recycling cavities for Advanced LIGO

Advanced Virgo Technical Design Report

Parametric signal amplification

arxiv: v1 [astro-ph.im] 19 Dec 2011

Calibration of the LIGO displacement actuators via laser frequency modulation

Possibility of Upgrading KAGRA

Multiply Resonant EOM for the LIGO 40-meter Interferometer

A gravitational wave is a differential strain in spacetime. Equivalently, it is a differential tidal force that can be sensed by multiple test masses.

VIRGO. The status of VIRGO. & INFN - Sezione di Roma 1. 1 / 6/ 2004 Fulvio Ricci

Downselection of observation bandwidth for KAGRA

ISC RF Photodetector Design: LSC & WFS

Linewidth-broadened Fabry Perot cavities within future gravitational wave detectors

This is a brief report of the measurements I have done in these 2 months.

Quantum States of Light and Giants

The AEI 10 m Prototype. June Sina Köhlenbeck for the 10m Prototype Team

LIGO-P R. High-Power Fundamental Mode Single-Frequency Laser

Mode mismatch and sideband imbalance in LIGO I PRM

arxiv: v2 [gr-qc] 12 Jun 2009

The VIRGO detection system

Squeezing with long (100 m scale) filter cavities

Stable Recycling Cavities for Advanced LIGO

Squeezed light at 1550 nm with a quantum noise reduction of 12.3 db

Toward the Advanced LIGO optical configuration investigated in 40meter prototype

Alessio Rocchi, INFN Tor Vergata

Wave Front Detection for Virgo

Broadband Photodetector

Gravitational Wave Detection and Squeezed Light

Timing accuracy of the GEO 600 data acquisition system

Arm Cavity as Squeezing Filter via Entanglement Swapping

Lasers for LISA: overview and phase characteristics

arxiv: v1 [quant-ph] 17 Oct 2011

Observation of Three Mode Parametric Interactions in Long Optical Cavities

Development of Optical lever system of the 40 meter interferometer

Squeezed light and radiation pressure effects in suspended interferometers. Thomas Corbitt

The VIRGO injection system

Plans for DC Readout Experiment at the 40m Lab

Optical Recombination of the LIGO 40-m Gravitational Wave Interferometer

Cavity Optics for Frequency-Dependent Light Squeezing

THE FUTURE OF VIRGO BEYOND ADVANCED DETECTORS. Gianluca Gemme INFN Genova for the Virgo Collaboration

Designing Optical Layouts for AEI s 10 meter Prototype. Stephanie Wiele August 5, 2008

First Observation of Stimulated Coherent Transition Radiation

LIGO SURF Report: Three Input Matching/Driving System for Electro-Optic Modulators

Parallel phase modulation scheme for interferometric gravitational-wave detectors

Mystery noise in GEO600. Stefan Hild for the GEO600 team. 14th ILIAS WG1 meeting, October 2007, Hannover

Physics of interferometric gravitational wave detectors

Length Sensing and Control for AdLIGO

Published in: Physical Review A. DOI: /PhysRevA Link to publication in the UWA Research Repository

Back-Reflected Light and the Reduction of Nonreciprocal Phase Noise in the Fiber Back-Link on LISA

A Thermal Compensation System for the gravitational wave detector Virgo

Simulations of Advanced LIGO: Comparisons between Twiddle and E2E

Techniques for the stabilization of the ALPS-II optical cavities

Quantum frequency standard Priority: Filing: Grant: Publication: Description

NEW LASER ULTRASONIC INTERFEROMETER FOR INDUSTRIAL APPLICATIONS B.Pouet and S.Breugnot Bossa Nova Technologies; Venice, CA, USA

Gravitational-Wave Detection, Mike Cruise, Peter Saulson, Editors, Proceedings of SPIE Vol (2003) 2003 SPIE X/03/$15.

Polarization Sagnac interferometer with a common-path local oscillator for heterodyne detection

Virgo status and commissioning results

The generation and application of squeezed light in gravitational wave detectors and status of the POLIS project

arxiv: v2 [quant-ph] 21 Aug 2017

Notes on the Pound-Drever-Hall technique

Diffractive gratings. in high-precision interferometry. for gravitational wave detection

Final Report for IREU 2013

CO2 laser heating system for thermal compensation of test masses in high power optical cavities. Submitted by: SHUBHAM KUMAR to Prof.

Cavity with a deformable mirror for tailoring the shape of the eigenmode

Using active resonator impedance matching for shot-noise limited, cavity enhanced amplitude modulated laser absorption spectroscopy

D.C. Emmony, M.W. Godfrey and R.G. White

Readout and control of a power-recycled interferometric gravitational wave antenna

Optical generation of frequency stable mm-wave radiation using diode laser pumped Nd:YAG lasers

Vibration measurement in the cryogenic interferometric gravitational wave detector (CLIO interferometer)

visibility values: 1) V1=0.5 2) V2=0.9 3) V3=0.99 b) In the three cases considered, what are the values of FSR (Free Spectral Range) and

Aspects, techniques and design of advanced interferometric gravitational wave detectors

1.6 Beam Wander vs. Image Jitter

HIGH POWER LASERS FOR 3 RD GENERATION GRAVITATIONAL WAVE DETECTORS

Transcription:

LIGO P070067 A Z A novel concept for increasing the peak sensitivity of LIGO by detuning the arm cavities arxiv:0709.1488v1 [gr-qc] 10 Sep 2007 1. Introduction S. Hild 1 and A. Freise 2 1 Max-Planck-Institut für Gravitationsphysik (Albert-Einstein-Institut) and Leibniz Universität Hannover, Callinstr. 38, D 30167 Hannover, Germany. 2 School of Physics and Astronomy, University of Birmingham, Edgbaston, Birmingham, B15 2TT, UK E-mail: stefan.hild@aei.mpg.de Abstract. We introduce a concept that uses detuned arm cavities to increase the shot noise limited sensitivity of LIGO without increasing the light power inside the arm cavities. Numerical simulations show an increased sensitivity between 125 and 400Hz, with a maximal improvement of about 80% around 225 Hz, while the sensitivity above 400 Hz is decreased. Furthermore our concept is found to give a sensitivity similar to that of a conventional RSE configuration with a Signal-Recycling mirror of moderate reflectivity. In the near future detuned arm cavities might be a beneficial alternative to RSE, due the potentially less hardware intensive implementation of the proposed concept. PACS numbers: 04.80.Nn, 95.75.Kk The first generation of large-scale laser-interferometric gravitational wave detectors [1, 2, 3, 4] is now in operation and collects data of impressive sensitivity and bandwidth. The optical configurations of these kilometer long gravitational wave observatories are based on a Michelson interferometer. Moreover, the standard configuration, implemented in the three LIGO interferometers as well as in Virgo and TAMA300, employs cavities in the arms of the interferometer and Power-Recycling to increase the storage time of the light inside the interferometer. In order to get an optimal power increase inside the arm cavities, these are kept to be resonant for the carrier light. However, as we show in this article, detuning these arm cavities by a few hundred Hz has the advantage of a larger signal gain in a certain frequency band and might therefore be favorable. In section 2 we give a brief and intuitive description of the principle of an optical configuration employing detuned arm cavities. Using a idealized interferometer as an example we show in section 3 that with detuned arm cavities the shot noise limited sensitivity can, in a certain frequency range, be increased using the same optical power circulating in the arm cavities as in the case of tuned arm cavities. In section 4 we compare the interferometer response with detuned arm cavities to a configuration using in addition the advanced technology of resonant sideband extraction (RSE). The potential benefit of using detuned arm cavities for LIGO is evaluated by simulations described in section 5. Finally we give a summary and an outlook in section 6.

A novel concept for increasing the peak sensitivity of LIGO by detuning the arm cavities2 carrier resonant carrier off resonant sideband resonant sideband off resonant a) b) c) ETY ETY ETY detuning ITY ITY ITY PRM BS ITX ETX PRM BS ITX ETX PRM BS ITX SRM detuning ETX initial LIGO/VIRGO detuned RSE detuned arm cavities Figure 1. Simplified schematics of the three optical configurations compared in this article. a) Initial LIGO configuration with arm cavities kept resonant for the carrier light. b) Initial LIGO configuration with additional detuned resonant sideband extraction. c) Initial LIGO configuration with arm cavities detuned to be resonant for the gravitational wave signal sidebands (abbreviations are explained in the text.) 2. The principle of detuned arm cavities Figure 1 a) shows a simplified schematic of the initial LIGO optical layout. The red and the dark blue lines indicate in which part of the interferometer carrier light (red) and gravitational wave signal sidebands (dark blue) are present. The carrier light enters the interferometer through the Power Recycling mirror (PRM) and is split by the beam splitter (BS) in equal shares into the X and Y arm. The arms consist of an arm cavity each, formed by two mirrors separated by 4km (ITX and ETX, ITY and ETY). These arm cavities are chosen to be resonant for the carrier light resulting in a larger power enhancement inside. The small Michelson interferometer formed by BS, ITY and ITX is kept on a dark fringe, thus no carrier light is leaving the interferometer towards the output port, but all light is going back to the input port so that it becomes further resonantly enhanced by PRM. The presence of a gravitational wave produces phase modulation sidebands around the carrier light. Because the signal sidebands in the two perpendicular arms have opposite phase they can interfere constructively at the BS to leave the interferometer at the output port. With the arm cavities being set on resonance for the carrier light, the signal sidebands of interest (f sig > 100Hz) experience less enhancement than the carrier light. A new concept that turns this principle around is to use detuned arm cavities as shown in Figure 1 c). In contrast to the conventional initial LIGO scheme the length of the arm cavities was chosen to be resonant for a specific single-sided signal sideband frequency, i.e. the cavities are detuned from the carrier frequency. This detuning can easiest be realized by shifting ETY and ETX in common mode either to shorten or to lengthen the arm cavities, corresponding to making them resonant for the upper Similar concepts were mentioned in [5] and [6]; their publications, however, focused on the properties of the opto-mechanical resonance in a detuned arm cavity, while in this paper we investigate the sensitivity enhancement from utilising the optical resonance.

A novel concept for increasing the peak sensitivity of LIGO by detuning the arm cavities3 and the lower signal sideband, respectively. The operating points of the other main mirrors (ITX, ITY, and BS) do not need to be changed. The obvious drawback of this scheme, in the following referred to as detuned arm cavities, is the lower optical power inside the arms, compared to arm cavities resonant for the carrier light. However, the achievable circulating power in current detectors is not limited by the available laser power nor the finesse of the arm cavities. Instead technical problems, like, for example, thermal lensing or parametric instabilities, become limiting factors when the circulating light power is increased [3]. Therefore we belief it useful to compare the concept of detuned arm cavities to resonant arm cavities with identical stored optical power. 3. Simulated shot noise limited sensitivity for an ideal Michelson interferometer employing Power-Recycling and detuned arm cavities In order to evaluate the benefit from detuning the arm cavities and resonantly enhancing the gravitational wave signal sideband we performed numerical simulations of the shot noise limited sensitivity using the FINESSE software [7]. As an example we have chosen an idealized and simplified Michelson interferometer with Power- Recycling employing tuned and detuned arm cavities of 4 km length. To simplify the simulation of shot noise, a DC-readout scheme was used. Table 1 gives a summary of the simulation: With an input power of 4W a circulating light power of 10kW is achieved in each arm cavity. The corresponding shot noise limited displacement sensitivity of such a configuration with arm cavities resonant for the carrier light is shown in Figure 2 (green solid trace). Transmission PRM 10% Transmission ITX/ITY 3 % Transmission ETX/ETY 0 % Input light power at PRM 4 W Light power in each arm 10kW Dark fringe offset at BS for DC-readout 0.3deg Table 1. Simulation of an ideal Michelson interferometer with DC-readout. By shifting the microscopic position of ETX and ETY we can detune the arm cavities, i.e. shifting their resonance. Here we choose a detuning frequency of 200Hz corresponding to a detuning of -1deg. This results in a reduction of the power buildup in the arm cavities by a factor of 6.25 which can be compensated by increasing either the input power from 4 to 25 W or the Power-Recycling gain (reducing the transmission of PRM from 10 to 1.7%) in order to restore the nominal 10 kw intra-cavity power. Table 2 shows the parameters used for the simulation of tuned and detuned arm cavity configurations. Figure 2 shows the shot noise limited displacement sensitivity of the two configurations with detuned arm cavities (red dashed and blue solid line). In a frequency band of between 150 to 350 Hz an increased sensitivity can be achieved. The maximal improvement is obtained around 230Hz. Below 150Hz and above 350Hz the Our initial simulations did not include radiation pressure nor optical spring effects. We later confirmed with a separate analysis that these effects play no role for the frequency band and in the configurations analyzed in this paper.

A novel concept for increasing the peak sensitivity of LIGO by detuning the arm cavities4 Scheme Tuning Input Transmission ETX/ETY [deg] power [W] PRM [%] arm cavities resonant 90/0 4.0 10.0 for carrier detuned arm cavities, 89/-1 25.1 10.0 input power increased detuned arm cavities, 89/-1 4.0 1.7 PR gain increased Table 2. Parameters used for the simulation of tuned and detuned arm cavity configurations in an ideal Michelson interferometer. All three scenarios lead to an intra-cavity power of 10kW. 10 18 Displacement [m/sqrt(hz)] 10 19 10 20 arm cavities resonant for carrier detuned armcavities, Input power increased detuned armcavities, PR gain increased arm cavities resonant for carrier + Signal Recycling 10 2 10 3 Frequency [Hz] Figure 2. Shot noise limited displacement sensitivity of an ideal Michelson interferometer with Power-Recycling with DC-readout in comparison to two configurations with detuned arms and a configuration using resonant sideband extraction (RSE). Using detuned arm cavities increases the sensitivity in a frequency range from 150 to 350 Hz. Detuned arm cavities give a sensitivity identical to RSE. sensitivity of the configurations with detuned arm cavities is worse than for tuned arm cavities. 4. Comparison of detuned arm cavities and resonant sideband extraction Resonant sideband extraction (RSE) [10] is a well known concept for increasing the sensitivity of gravitational wave detectors by placing an additional mirror in the output port of the instrument (see Figure 1 b). This concept is foreseen to be implemented in the second generation instruments such as Advanced LIGO [9]. Similar to the

A novel concept for increasing the peak sensitivity of LIGO by detuning the arm cavities5 concept of using detuned arm cavities, RSE allows to increase the sensitivity of the interferometer in a certain frequency band by sacrificing the sensitivity outside this band. Our simulations show that the sensitivity of a detector using detuned arm cavities can exactly be reproduced by using tuned arm cavities and RSE (see black solid line in Figure 2). For the simulation of RSE we used a Signal-Recycling mirror (SRM) with a reflectivity of 58% and a tuning phase of 70deg. The finding is that the following two concepts Tuned arm cavities together with RSE Detuned arm cavities with increased Power-Recycling gain are in principal equivalent. Interestingly, the implementation of the second concept is significantly easier. While RSE requires the installation of an additional suspended mirror and a completely new control scheme for additional degrees of freedom (longitudinal and alignment), detuned arm cavities only require a slightly more complex length sensing and control scheme (see below) and the exchange of PRM by one with 1.7 instead of 10% reflectivity. Furthermore, the Fourier frequency of the peak sensitivity can be adjusted online by tuning the settings of the control system, similarly to an RSE system. 1 Error signal [a.u.] 0.5 0 0.5 1 0.1 0.05 0 0.05 0.1 CARM tuning [deg] Figure 3. Example error signal for the common mode arm cavity length (CARM) for an interferometer with detuned arm cavities; zero CARM tuning refers to the new detuned operating point. The error signal is obtained by demodulating the light reflected of the back of BS at an additional RF frequency. The plot shows several traces for different demodulation phase (50 to 70 degrees, in 5 degree increments). When implementing detuned arm cavities into a currently running detector the bandwidth of the signal enhancement (corresponding to the reflectivity of the SRM in RSE) is linked to the Finesse of the arm cavities. A potential disadvantage of detuned Both, Virgo and GEO 600, already replaced their PRM by one of higher reflectivity during recent commissioning periods. Thereby no significant problems had been encountered.

A novel concept for increasing the peak sensitivity of LIGO by detuning the arm cavities6 arm cavities might be the slightly higher light power inside the small Michelson interferometer originating from the increased Power-Recycling gain. At first glance the length sensing and control for an interferometer with detuned arm cavities looks very similar to the standard LIGO control problem. Effectively only an offset to the operating point of the common mode arm (CARM) signal has to be introduced. Unfortunately this offset is much larger than the dynamic range of the original CARM error signal. Hence, in order to obtain a suitable CARM control signal a new RF modulation has to be introduced. Figure 3 show example error signals for the new CARM operating point derived from RF modulation at approximately 15 MHz. The demodulation phase in combination with the exact value of the RF frequency determines the operating point of the CARM signal. This poses a new constraint on the quality of the control electronics, which however, is a known and understood feature of detuned Signal-Recycling control systems as well [12]. Preliminary investigations show further that appropriate error signals for all other degrees of freedom can easily be obtained. The detuning of the arm cavities has virtually no effect on the differential mode arm signal and the Power-Recycling control but degrades slightly the quality of the small Michelson error signal. 5. Initial LIGO with detuned arm cavities After we explained the principle operation of the detuned arm cavity concept in the previous section using an ideal Michelson interferometer with power recycling, this section is devoted to simulating the benefit of detuned arm cavities for a real system, i.e. initial LIGO. We used the best estimate for optical parameter currently available [11]. The values for the most important parameters are given in Table 3. The sensitivity achieved with these parameters is shown in Figure 4 (green dashed line). Using resonant arm cavities in the simulation yields an intra cavity power 14.7 kw per arm. This configuration is in the following compared to one optical scheme employing detuned arm cavities. Since the sensitivity of the initial LIGO detectors is only shot noise limited above 150Hz [8], we choose here a detuning frequency of 200Hz corresponding to a detuning of -1deg. In order to (at least partly) compensate the decreased power buildup in the arm cavities we use for this simulation a PRM with 1 % instead of 2.7% transmission leading to an intra-cavity power of 11kW. The corresponding shot noise limited sensitivity is shown in Figure 4 (blue solid line). In a frequency band between 125 and 400 Hz an improvement is achieved. The maximal increase in sensitivity amounts to about 80% around 225Hz. Above 400Hz the decrease of the shot noise limited sensitivity increases with the frequency. At 1kHz a sensitivity reduction of 45% is observed. 6. Summary and outlook We have introduced a new concept that uses detuned arm cavities combined with a moderately increased Power-Recycling gain to increase the shot noise limited sensitivity of initial LIGO for frequencies between 125 and 400 Hz, without increasing the light power inside the arm cavities. This concept is found to give a sensitivity similar to that of a conventional RSE configuration with a SRM of moderate reflectivity. The implementation of detuned arm cavities might require less new hardware than RSE. This is a considerable advantage, however, further investigations

A novel concept for increasing the peak sensitivity of LIGO by detuning the arm cavities7 Transmission PRM 2.7% Transmission ITX/ITY 2.8% Transmission ETX/ETY 10 ppm Loss at each coating 90ppm Radius of curvature ITX/ITY/PRM -14.3km Radius of curvature ETX/ETY 8.0km Input light power at PRM 6 W Dark fringe offset at BS for DC-readout 0.3deg Table 3. Simulation of initial LIGO with DC-readout. The parameters are taken from [11]. Initial LIGO, resonant arm cavities Initial LIGO, detuned arms + increased PR gain Strain [1/sqrt(Hz)] 10 22 Sensitivity improvement 10 23 1.75 1.5 1.25 0.75 10 2 10 3 2 1 detuned arms 0.5 10 2 10 3 Frequency [Hz] Figure 4. UPPER SUBPLOT: Shot noise limited strain sensitivity for initial LIGO using resonant arm cavities (green dashed trace) and detuned arm cavities (blue solid line). In case of detuned arm cavities the original PRM of 2.7% transmittance was exchanged by on with only 1% transmittance. Still the circulating light power is with 11 kw smaller than for resonant arm cavities (14.7 kw). Using our proposed concepts allows to increase the sensitivity of initial LIGO in the frequency band between 125 and 400Hz. LOWER SUBPLOT: Ratio of the achieved strain sensitivities with resonant and detuned arm cavities. A maximal improvement of 80% is achieved around 225 Hz. and simulations should be performed to evaluate the performance of the proposed scheme with respect to noise couplings.

A novel concept for increasing the peak sensitivity of LIGO by detuning the arm cavities8 We have chosen to validate the concept using the initial LIGO configuration because the real parameters and performance of the running interferometers are well known. Nevertheless, the same concept is applicable to these interferometers after the next upgrade: enhanced LIGO. Further investigations are required, however, to understand the technical limits to the circulating power in the arm cavities and the small Michelson in a realistic enhanced LIGO scenario. Acknowledgments The authors would like to thank R. Adhikari, M. Evans, K. Kawabe, K. Danzmann and H. Lueck for fruitful discussions. A. F. would like to thank PPARC for financial support of this work. This document has been assigned LIGO Laboratory document number LIGO-P070067-00-Z. References [1] Hild S et al 2006 The Status of GEO 600 Class. Quantum Grav. 23, 643 651. [2] Acemese F et al 2004 Status of VIRGO Class. Quantum Grav. 21, 385 394. [3] Sigg D et al 2004 Commissioning of LIGO detectors Class. Quantum Grav. 21 409 415. [4] Takahashi R (the TAMA Collaboration) 2004 Status of TAMA300 Class. Quantum Grav. 21 403 408. [5] Rakhmanov M, PhD-thesis, 2000, California Institute of Technology. [6] Rehbein H, personal communication 2007. [7] Freise A et al 2004 Frequency-domain interferometer simulation with higher-order spatial modes Class. Quantum Grav. 21, 1067 1074. [8] Waldman S et al 2006 Status of LIGO at the start of the fifth science run Class. Quantum Grav. 23, 653 660. [9] www.ligo.caltech.edu/advligo/ [10] Mizuno J et al 1993 Resonant sideband extraction: A new configuration for interferometric gravitational wave detectors Phys. Lett. A 175, 273 276. [11] Adhikari R and Garofoli J personal communication 2007. [12] Freise A et al 2000 Demonstration of detuned dual recycling at the Garching 30 m laser interferometer Phys. Lett. A 277, 135 142.