IECEx Certificate of Conformity

Similar documents
IECEx Certificate of Conformity

IECEx Certificate of Conformity

Certificate of Conformity

IECEx Ex TEST REPORT COVER

Operating Manual. isolate501

Certification of EXPLOSION PROTECTED ELECTRICAL EQUIPMENT

IECEx BVS X issue No. :3. Funkwerk Security Communications GmbH John-F. -Ken nedy-stral1e Salzgitter Germany

Description. Annexe to: IECEx CML X Issue 1. Isolating Amplifier D461

Certificate of Compliance

Certificate of Conformity

Isolators A3/1. Vibration Transducer Supply Unit Series

IECEx Certificate of Conformity Annexe

Certificate of Conformity

Power supply. Calibration. Surface finishing. Seal. Process connection

IECEx Certificate of Conformity

Micro Motion Model 5700 Transmitter IECEx Zone 2/22 Installation Instructions EPL Gc and EPL Dc

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

Binary Output Series 9175

Binary Output without Power Supply Series 9176

Solexy USA, LLC International Blvd Cincinnati, Ohio Phone: Fax:

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

IECEx Certificate of Conformity

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

TÜV NORD CERT. TÜV NORD CERT GmbH & Co. KG Am TÜV 1 D Hannover. Annexe to IECEx TUN , issue No. 0 Page 1 of 5.

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

User's Manual. ROTAMASS Total Insight Coriolis Mass Flow and Density Meter Explosion Proof Type Manual IECEx IM 01U10X02-00EN-R

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

Micro Motion Model 5700 Transmitter ATEX Zone 2/22 Installation Instructions II 3 G or II 3 (2) G/EPL Gc & II 3 D/EPL Dc

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

Safety Instructions Nivotester FTC625, FTC325

Specifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift

D1035S INSTRUCTION MANUAL. Frequency-Pulse Isolating Repeater DIN Rail Model D1035S. D Frequency-Pulse Isolating Repeater

Ex instruction manual. Rotamass Coriolis mass flow meter. IECEx. IM 01U10X02-00EN-R_002, 2nd edition,

Analog Universal Module HART for Zone 2 Series 9468/33

Installation Instructions P/N MMI , Rev. AA July ATEX Installation Instructions for Micro Motion Model 3500 Transmitters

Isolators A3/1.

CERTIFICATE OF COMPLIANCE

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

The SENSE and SIGNAL inputs are very high impedance and are unaffected by the (~384ohm) series resistance of the xx61p barriers.

Inductive sensor slot-type SI2-K08-AP7

Single-Channel Safety Barriers Series 9001

IECEx Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

Temperature Input Module for Zone 1 Series 9482/32

Installation & Operating Manual. iwap202

Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Ex instruction manual. Rotamass Coriolis mass flow meter ATEX. IM 01U10X01-00EN-R_002, 2nd edition,

Safety Manual. Omni-ID UHF Tags

Isolating Repeater Input Series 9163

Introduction Intrinsic safe system How to select sensors How to select safety barriers...6 Revision Information...

1 About this manual Related documents Product description Getting started Mechanical installation...

INSTRUCTION MANUAL. SIL 3 Switch/Proximity Detector Interface DIN-Rail Models D1034S, D1034D D1034S - D1034D

INSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q

KMS-2 Exia Magnetostrictive Level Transmitter

MTL4000 SERIES. isolating IS interface units. For close integration of IS circuits into processconnected

Digital Input Output Module for Zone 2 Series 9470/33

INSTRUCTION MANUAL (ATEX / IECEx)

D1061S INSTRUCTION MANUAL. RS422/RS485 Fieldbus Isolating Repeater Din-Rail Model D1061S. D RS422 / RS485 Fieldbus Isolating Repeater

User manual. Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD

Remote I/O. 74 Remote I/O. Remote I/O System

INSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q

SET Installation and Operating Instructions. Level switch for two sensors

User manual. Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD

D1061S INSTRUCTION MANUAL. RS422/RS485 Fieldbus Isolating Repeater Din-Rail Model D1061S. D RS422 / RS485 Fieldbus Isolating Repeater

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Transducer transmitter BILT 4 II 2(1) G. Technical Manual

GETTING STARTED GUIDE NI AI, ±5 V, 24 Bit, 51.2 ks/s/ch Simultaneous, AC/DC Coupling, IEPE AC Coupling

Certificate of Conformity

Fieldbus Isolating Repeater Series 9185/11

Digital Input Output Module for Zone 2 Series 9470/33

DPharp Differential Pressure and Pressure Transmitters

Digital Input Output Module for Zone 1 Series 9470/32

SOLENOID TYPE, CERTIFICATION & PROTECTION CONCEPTS

Annex 1 to Certificate of Conformity IECEx KEM X Issue No. 8 Rota Yokogawa Rotamass 3 Series Coriolis Mass Flowmeter

... for hydraulic and general applications in hazardous areas

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

Quick Start Guide , Rev CB June Emerson Smart Wireless Field Link

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

megablock series passive hubs for fieldbus networks

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

Adjustable Terminal Clamp Insulation. Fixed Terminal Clamp See Terminal Wiring Note. Body. Maximum Power Dissipation (Watts) T** T*** -60 C +55 C T**

Certificate of Compliance

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

F2xx & F2xx-XE megablock range

SINEAX TI 807 Passive DC signal isolator

technical datasheet technical datasheet Megablock Series passive hubs for fieldbus networks

INTRINSICALLY SAFE DUPLEXER

Isolated Intrinsic Safety Barrier

ATEX Installation Drawings and Instructions

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

GETTING STARTED GUIDE NI AI, ±10 V, 24 Bit, 50 ks/s/ch Simultaneous

MTL700 SERIES. Shunt-diode safety barriers. For safe measurement and control in hazardous areas. 1 or 2 channels in same slim package

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

Product manual wire programmable RTD transmitter

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

Title: INTRINSIC SAFETY MADE EASY

RMA42. Technical Information

2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER

Transcription:

INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: Certificate history: Issue No. 7 (2017-05-02) Status: Current 2017-05-02 Page 1 of 5 Issue NO.6 (2016-10-05) Issue NO.5 (2014-01-27) Issue No.4 (2013-03-04) Issue No.3 (2012-08-06) Applicant: Eaton Electric Umited Issue NO.2 (2011-01-31) Great Marlings, Butterfield Issue No.1 (2010-06-28) Luton, Bedfordshire Issue No. 0 (2009-07-09) LU28DL Equipment: MTL5541S, MTL5541S-T, MTL5544S &MTL5544D Repeater Power Supplies, 4I2OmA Opffonalaccesso~: Type of Protection: Intrinsic safety Marking: [Ex ia Ga] IIC [Ex ia 08] mc [Exia Ma] I _2O D C ~ Ta ~ +«ldc - MTL5541S, MTL5544S & MTL5544D Models -2O D C ~ Ta ~ +65 D C - MTL55418-T Model only Approved for issue on behalfof the IECEx Certification Body: R. S. Sinclair Position: Technical Manager Signature: (for printed version) Date: 1. This certificate and schedule may only be reproduced in full. 2. This certificate is not transferable and remains the property of the issuing body. 3. The Status and authenticity of this certificate may be verified by visiting the OfficiallECEx Website. Certificate issued by: SGS 8aIeefa Linited Rodchead Business Park staden l..ale BuxIDn. Derb)8hire, SK17 9RZ Umed Kingdom

2017-o~ Page 2 of 5 Manufacturer: Eaton EIecbic Umited Great Marlings. Butterfield Luton, Bedfordshire LU28DL Additional Manufacturing location(s): MTL Instrunents Pvt Umited No 3 Old Mahabalipuram Road Sholinganallur Chennai600119 India This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended. STANDARDS: The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards: IEC 60079-0 : 2011 Edition:6.0 IEC 60079-11 : 2011 Edition:6.0 Explosive atmospheres - Part 0: General requirements Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above. TEST & ASSESSMENT REPORTS: A sample(s) ofthe equipment listed has successfully met the examination and test requirements as recorded in Test Report: GB/BAS/ExTR09.0103/00 GB/BAS/ExTR12.0181/00 GB/BAS/ExTR16.0238/00 Quality Assessment Report: GB/BAS/QAR06.0022106 GB/BAS/ExTR10.0100100 GB/BAS/ExTR13.0022/00 GB/BAS/ExTR17.0080100 GB/BAS/QAR07.0017/06 GB/BAS/ExTR10.0298/00 GB/BAS/ExTR14.0019/00

2017-o~ Page 3 of 5 Schedule EQUIPMENT: Equipment and systems covered by this certificate are as follows: The MTL5544S Two Channel Repeater Power Supply, 4/20mA for 'Smart' Transmitters is designed to provide floating d.c. supplies for energising two 'Smart' 4/20mA Transmitters located in the hazardous area and repeat these currents in the non-hazardous area, whilst restricting the transfer of energy from the unspecified non-hazardous area apparatus to the intrinsically safe circuits by means of limitation of current and voltage. The apparatus also allows bi-directional signal communication between the hazardous and nonhazardous area by the connection of a hand-held communicator (HHC). The MTL5544S Two Channel Repeater Power Supply, 4/20mA for 'Smart' Transmitters comprises four isolating transformers that provide galvanic isolation between the hazardous and non-hazardous area circuitry, zener diode chains and resistors providing voltage and current limitation. The above, together with other electronic components are mounted on a single printed circuit board (PCB) and housed in a moulded plastic enclosure. Polarised plugs and sockets are provided for hazardous and non-hazardous area connections. LED indication is fitted to indicate power-on. The MTL5541 S Single Channel Repeater Power Supply, 4/20mA for 'Smart' Transmitters is a depopulated version of the MTL5544S and has only one channel populated. The MTL5541 S-T Single Channel Repeater Power Supply, 4/20mA for 'Smart' Transmitters is of a similar construction to the MTL5541 S variant of the equipment with the same input and output parameters, but has an extended ambient temperature range. See the Additional Page for further model information. SPECIFIC CONDITIONS OF USE: NO

2017-o~ Page 4 of 5 EQUIPMENT (continued): The MTL5544D Repeater Power Supply, 4/20mA for 2 or 3 Wire Transmitters with two outputs is designed to provide a floating d.c. supplies for energising a 2 or 3-Wire 4/20mA Transmitter located in the hazardous area and repeat the current on two channels in the non-hazardous area, whilst restricting the transfer of energy from the unspecified non-hazardous area apparatus to the intrinsically safe circuits by means of limitation of current and voltage. The apparatus also allows bi-directional signal communication between the hazardous and non-hazardous area by the connection of a hand-held communicator (HHC). The apparatus uses the same printed circuit board and enclosure as the MTL5544S but is populated with only one hazardous area transmitter connection and two nonhazardous area outputs fitted. See annex for electrical parameters.

2017-05-02 Page 5 of 5 DETAILS OF CERTIFICATE CHANGES (for issues 1 and above): Variation 7.1 To permit the addition of the MTL5541 S-T Single Channel Repeater Power Supply, 4/20mA for 'Smart' Transmitters to the range covered by the certificate. The MTL5541 S-T is of similar construction to the MTL5541 S variant and has the same input and output parameters, but has an extended ambient temperature range of -20 C to +65 C. The Equipment Title, Marking section and Schedule was revised to detail the new variant of the equipment. The Certificate Annex (now Issue 3) was updated to list the new variant. Variation 7.2 To permit a minor drawing change not affecting the original assessment. ExTR: GBlBASlExTR17.0080/00 File Reference: 17/0163 Annex: Annex Iss 3.pdf

SGS Baseefa Limited Rockhead Business Park Staden lane, Buxton, Derbyshire SK17 9RZ ANNEX to Issue No. 3 Date: 2 May 2017 MTL5541S Single, MTL5541S-T Single & MTL5544S Two Channel Repeater Power Supply, 4/20mA for Smart Transmitters and MTL5544D Repeater Power Supply, 4/20mA for 2 or 3 Wire Transmitters with Two Outputs Input/Output Parameters Non-hazardous Area Terminals 8, 9, 11, 12, 13 & 14 U m = 253V r.m.s. The apparatus is designed to operate on non-hazardous area terminals 8, 9, 11, 12, 13 & 14 from a d.c. supply voltage of up to 35V. Hazardous Area Terminals 2 w.r.t. 1 (Channel 1) Or Hazardous Area Terminals 5 w.r.t. 4 (Channel 2 MTL5544S model) U o = 28V C i = 0 I o = 93mA L i = 0 P o = 0.65W Hazardous Area Terminals 3 w.r.t. 1 (Channel 1) Or Hazardous Area Terminals 6 w.r.t. 4 (Channel 2 MTL5544S model) U o = 1.1V U i = 30V C i = 0 I o = 53mA I i = 121mA L i = 0 P o = 15mW Although the apparatus does not comply with the simple apparatus requirements of Clause 5.7 of IEC 60079-11: 2011, when terminals 3 w.r.t. 1 or terminals 6 w.r.t 4 (MTL5544S model only) are connected in an intrinsically safe circuit the internal stored energy, voltage and current of the interface will not add more than the values specified in Clause 5.7 of IEC 60079-11: 2011 to the parameters of the circuit into which it is connected. When an external intrinsically safe source is connected to these terminals it should have a source resistance of U i / I i and the capacitance and either the inductance or inductance to resistance ratio (L/R) of the hazardous area connections must not exceed the values detailed in the certificate of the intrinsically safe source. Hazardous area terminals 2 and 5 must not be used when the source is connected. Hazardous Area Terminals 2 w.r.t. 3 (Channel 1) Or Hazardous Area Terminals 5 w.r.t. 6 (Channel 2 MTL5544S model) U o = 28V C i = 0 I o = 87mA L i = 0 P o = 0.61W Each channel must be considered as a separate intrinsically safe circuit. The capacitance and either the inductance or inductance to resistance ratio (L/R) of the hazardous area load connected must not exceed the following values for either channel: Page 1 of 2

SGS Baseefa Limited Rockhead Business Park Staden lane, Buxton, Derbyshire SK17 9RZ ANNEX to Issue No. 3 Date: 2 May 2017 Notes: GROUP CAPACITANCE INDUCTANCE OR L/R RATIO (µf) (mh) (µh/ohm) Hazardous Area Terminals 2 w.r.t. 1 or 5 w.r.t. 4 (MTL5544S only) IIC 0.083 4.2 56 IIB* 0.65 12.6 210 IIA 2.15 33.6 444 I 3.76 53.7 668 Hazardous Area Terminals 3 w.r.t. 1 or 6 w.r.t 4 (MTL5544S only) IIC 100 12.8 2,438 IIB* 1,000 47.8 8,932 IIA 1,000 104.7 18,140 I 1,000 156.2 28,229 Hazardous Area Terminals 2 w.r.t. 3 or 5 w.r.t. 6 (MTL5544S only) IIC 0.083 4.9 59 IIB* 0.65 20.0 222 IIA 2.15 40.9 469 I 3.76 59.1 710 1) The above load parameters apply when one of the two conditions below is given: - the total L i of the external circuit (excluding the cable) is < 1% of the L o value or - the total C i of the external circuit (excluding the cable) is < 1% of the C o value. 2) The above parameters are reduced to 50% when both of the two conditions below are given: - the total L i of the external circuit (excluding the cable) is 1% of the L o value and - the total C i of the external circuit (excluding the cable) is 1% of the C o value. The reduced capacitance of the external circuit (including cable) shall not be greater than 1µF for Groups IIB, IIA & I and 600nF for Group IIC. * Group IIB parameters also applicable for associated apparatus [Ex ia Da] IIIC Page 2 of 2