Cisco QSFP-100G-LR4-S. Part Number: QSFP-100G-LR4-S QSFP-100G-LR4-S OVERVIEW PRODUCT FEATURES APPLICATIONS. FluxLight, Inc

Similar documents
100Gbs QSFP28 LR4 Optical Transceiver Module WT-QSFP28-LR4

Shenzhen Opway Communication Co., Ltd. 100Gb/s QSFP28 LR4 Optical Transceiver (OPQE10)

DATASHEET 4.1. QSFP, 40GBase-LR, CWDM nm, SM, DDM, 6.0dB, 10km, LC

Arista QSFP-40G-PLR4. Part Number: QSFP-40G-PLR4 QSFP-40G-PLR4 OVERVIEW PRODUCT FEATURES APPLICATIONS FUNCTIONAL DIAGRAM.

Arista 40GBASE-XSR4-AR. Part Number: 40GBASE-XSR4-AR 40GBASE-XSR4-AR OVERVIEW APPLICATIONS PRODUCT FEATURES. FluxLight, Inc

T G W Q 1 4 B B F 8 1

Arista Networks QSFP-100G-SR4-AR. Part Number: QSFP-100G-SR4-AR QSFP-100G-SR4-AR OVERVIEW PRODUCT FEATURES APPLICATIONS.

XQS319-10LY. 100 Gb/s QSFP28 LR4 (Ethernet) Optical Transceiver. XQS319-10LY QSFP28 LR4 Optical Transceiver. Features

T C W Q 1 L A A K C Q

QSFP, 40GBase-SR, 850nm, MM, MPO

Cisco QSFP-40G-SR4. Part Number: QSFP-40G-SR4 PRODUCT FEATURES APPLICATIONS. FluxLight, Inc

SO-CFP4-LR4. CFP4, 103/112 Gbps, 1310nm, SM, DDM, 6.3dB, 10km OVERVIEW PRODUCT FEATURES ORDERING INFORMATION DATASHEET 4.1

DATA SHEET: Transceivers

40G-QSFP-ER4-LEG. 40Gbase QSFP+ Transceiver

40Gb/s QSFP+ LR4 Parallel Single Mode Optical Transceiver TR-IQ13L-N00. Product Specification

QSFP Gbps QSFP28 PSM4 Optical Transceiver Module. Features

QSFP-40GBase-eSR4 MPO, 850nm, MMF, 300m. QSFP-40GBase-eSR4-IND. Quick Spec:

SO-QSFP28-SR4. QSFP, 100GBASE-SR, 850nm, MM, MPO OVERVIEW PRODUCT FEATURES APPLICATIONS ORDERING INFORMATION DATASHEET 4.

PRE-QSFP28-SR4 100Gb/s QSFP28 Optical Transceiver, 100m

40Gb/s QSFP+ esr4 Optical Transceiver Module QSFP-4000-ESR4. Product Specification

QSFP SFP-QSFP-40G-LR4

Cisco QSFP-40G-SR4 MPO, 850nm,MMF, 150m. Cisco QSFP-40G-SR4 Quick Spec:

SO-QSFP28-4xSFP28-AOCxM

QSFP SV-QSFP-40G-LR4L

1. General Description This product is a 100Gb/s transceiver module for optical communication applications compliant to 100GBASE-LR4 of the IEEE P802.

XCS319-10LY. 100GBASE-LR4 CFP4 Optical Transceiver. Features. Applications. General Description

40GBASE-ER4 Ethernet Industrial: -40 C to 85 C. Infiniband QDR and DDR Four 10G DFB base CWDM channels on. Distance * (note2) Interface Temp.

QSFP-40G-LR4-S-LEG. 40Gbase QSFP+ Transceiver

OPENETICS. P/N Gb/sQSFP+SR4Transceiver PRODUCT FEATURES APPLICATIONS STANDARD. Specialist Manufacturer Voice Data Security.

40 Gigabit QSFP 850 nm QSFP SR4

40GBd QSFP+ LR4 Optical Transceiver

CFORTH-QSFP28-100G-LR4 Specifications Rev. D00B. Product Features

QSFP. Parameter Symbol Min Max Unit Notes. Relative Humidity (non-condensation) RH 0 85 %

XQM859-M1PY. 100 Gb/s QSFP28 SR4 Optical Transceiver. XQM859-M1PY QSFP28 SR4 Optical Transceiver. Features

QSFP SV-QSFP-40G-PLR4L

40G-PSM4 QSFP+ Transceiver

40Gbps QSFP SR4 Optical Transceiver Module TR-QQ85S-N00. (Preliminary)

100Gbs QSFP28 PSM4 Optical Transceiver Module WT-QSFP28-PSM4

Product Specification 10km Multirate QSFP+ Optical Transceiver Module FTL4C1QM1C

CFP2. Parameter Symbol Min Max Units Notes. Storage Temperature Ts degc. Relative Humidity (non-condensation) RH 85 %

QSFP-100G-SR4-AR-LEG. 100Gbase QSFP28 Transceiver

CFP4. Parameter Symbol Min Max Units Notes. Storage Temperature Ts degc. Relative Humidity (non-condensation) RH 85 %

QSFP+ Dual LC 40G SMF 10km Transceiver. Features. Applications. Ordering Information APPLIED OPTOELECTRONICS, INC.

Product Specification 40GE SWDM4 QSFP+ Optical Transceiver Module FTL4S1QE1C

Product Specification 40GBASE-LR4 Lite QSFP+ Optical Transceiver Module FTL4C1QL2C

40Gbps QSFP ER4 Optical Transceiver Module OPCS-S40-13-CB datasheet

100G QSFP28 LR4 Receiver

Product Specification 40GBASE-LR4 QSFP+ Optical Transceiver Module FTL4C1QE1C

T Q S Q 1 4 H 9 J 8 2

40-Gbps QSFP + Optical Transceiver Module

40G-BASE-LR4 10km QSFP+ Optical Transceiver GTR3QP1L

QSFP28. Parameter Symbol Min Max Units Notes Storage Temperature TS degc

DATASHEET G Data Center Interconnect (DCI) 100G Embedded DWDM (DWDM transciever in to Ethernet switch with no OEO transponder requirement)

40Gbps QSFP+ IR4 Parallel Single Mode Optical Transceiver Module OPCS-S01-13-CBS datasheet

PROLABS JD121B-C. 10 Gigabit 1550nm SingleMode XFP Optical Transceiver, 40km Reach.

XFP-10G-Z-OC192-LR2-C

QSFP+ Series. EOLQ-1640G-10 Series. Features. Applications. Ordering Information. Single-Mode 40GBASE-LR4 QSFP+ Transceiver RoHS6 Compliant

QSFP+ Series Preliminary EOLQ-8540G-03-MO Series

Specification. Small Form Factor Pluggable 28 Duplex / Single TX / Single RX LC Receptacle SFP28. Optical Transceivers 24 Gigabit SDI.

T A S A 1 E B 1 F A Q

XFP-10GLR-OC192SR-C. 10 Gigabit XFP Transceiver, LC Connectors, 1310nm, SingleMode Fiber 10km

100Gbps QSFP28 CWDM4 Optical Transceiver Module OPCW-S02-13-CB4 datasheet

T Q S Q 7 4 H 9 J C A

XFP-10GER-192IR V Operating Environment Supply Voltage 1.8V V CC V Operating Environment Supply Current 1.8V I CC1.

100Gbps QSFP28 LR4 OTU4 Optical Transceiver Module OPCW-S10-13-CBT datasheet

100-Gbps QSFP28 SR4 Optical Transceiver Module PN: WST-QS28-SR4-C

Product Specification 100GBASE-SR10 100m CXP Optical Transceiver Module FTLD10CE1C APPLICATIONS

Data Sheet. 10Gb DWDM XFP Transceiver, 80km Hot Pluggable, Duplex LC, DWDM EML-LD, APD Receiver SM, PXFP-0D71SF-XX Issue: November 2010

40GBase LR4 QSFP+ Optical Transceivers WST-QSFP+LR4-C

10Gb/s 10km Datacom XFP Optical Transceiver XFP-10G-LR

Applications: Description:

Parameter Symbol Min Max Unit Storage Temperature T ST Case Operating Tempature Tc Supply Voltage V CC V

SFP-1020-WA/B 10Gbps SFP+ Bi-Directional Transceiver, 20km Reach 1270/1330nm TX / 1330/1270 nm RX

QSFP28 Dual LC 100G SMF 2km Transceiver. Features. Applications. Ordering Information APPLIED OPTOELECTRONICS, INC.

10Gb/s 80km DWDM XFP Optical Transceiver

Applications: Description:

LTA8531 QSFP28 SR4 Transceiver

Applications: DWDM Networks SONET OC-192/SDH STM-64 10GBASE-ER/EW Ethernet 40km 10G Fiber Channel. Description:

PROLABS QSFP-4x10G-AC7M-C QSFP+ to 4 SFP+ Active Copper Cable Assembly

X2-10GB-LR-OC Transceiver, 1310nm, SC Connectors, 10km over Single-Mode Fiber.

T Q S - Q 1 L H 8 - X C A x x

10Gbps XFP Optical Transceiver RTXM226-6XX

GBP-XXXX192-L2C 10Gbps SFP+ Bi-Directional Transceiver, 20km Reach 1270/1330nm TX / 1330/1270 nm RX

SPQ-10E-SR-CDFG 40G QSFP+ Transceiver

81.71T-XDWDM-R6-TP 10Gb/s Tunable DWDM XFP 80km Transceiver

10Gbps XFP Optical Transceiver

Product Features. Applications. Standards Compliance. 10G SFP+ LR Transceiver. General Description

10Gb/s CWDM SFP+ Optical Transceiver TR-LXxxL-N00

10Gbps XFP Optical Transceiver RTXM

Product Specification RoHS-6 Compliant 10Gb/s 850nm Multimode Datacom XFP Optical Transceiver

LX8501CDR 100G 100m QSFP28 Transceiver 100GBASE-SR4

SO-SFP-16GFC-ER-Dxxxx

This 1310 nm DFB 10Gigabit SFP+ transceiver is designed to transmit and receive optical data over single mode optical fiber for link length 10km.

QSFP28 100G MPO MMF 850nm 70m Transceiver AQPMDN85ADLN0782. Features. Applications. Ordering Information APPLIED OPTOELECTRONICS, INC.

T A S A 5 N B 1 F A H

Utilizes a standard 24/20 lane optical fiber with MPO connector

FTLD12CL3C. Product Specification 150 Gb/s (12x 12.5Gb/s) CXP Optical Transceiver Module PRODUCT FEATURES

Multiplex, Inc. 8.5Gb/s DWDM 80Km LR2 XFP Transceiver Product. Product Overview. Features

10Gb/s Tunable DWDM XFP 80km Transceiver

XFP DWDM 10G 80Km ZR SLXFD-10XX-ZR

Transcription:

Part Number: QSFP-100G-LR4-S QSFP-100G-LR4-S OVERVIEW The QSFP-100G-LR4-S is a 100 Gbps transceiver module designed for optical communication applications compliant to 100GBASE-LR4 of the IEEE P802.3ba standard. The module converts 4 input channels of 25 Gbps electrical data to 4 channels of LAN WDM optical signals and then multiplexes them into a single channel for 100 Gbps optical transmission. Reversely on the receiver side, the module de-multiplexes a 100 Gbps optical input into 4 channels of LAN WDM optical signals and then converts them to 4 output channels of electrical data. The central wavelengths of the 4 LAN WDM channels are 1295.56, 1300.05, 1304.58 and 1309.14 nm as members of the LAN WDM wavelength grid defined in IEEE 802.3ba. The high performance cooled LAN WDM EA-DFB transmitters and high sensitivity PIN receivers provide superior performance for 100Gigabit Ethernet applications up to 10km links and compliant to optical interface with IEEE802.3ba Clause 88 100GBASE-LR4 requirements. The product is designed with form factor, optical/electrical connection and digital diagnostic interface according to the QSFP+ Multi-Source Agreement (MSA). It has been designed to meet the harshest external operating conditions including temperature, humidity and EMI interference. PRODUCT FEATURES Hot pluggable QSFP28 MSA form factor Compliant to IEEE 802.3ba 100GBASE-LR4 Up to 10km reach for G.652 SMF Single +3.3V power supply Operating case temperature: 0~70 o C Transmitter: cooled 4x25 Gbps LAN WDM EML TOSA (1295.56, 1300.05, 1304.58, 1309.14nm) Receiver: 4x25Gb/s PIN ROSA 4x28G Electrical Serial Interface (CEI-28GVSR) Maximum power consumption 4.0W Duplex LC receptacle APPLICATIONS 100GBASE-LR4 Ethernet Links Page 1 of 9

Infiniband QDR and DDR interconnects Client-side 100G Telecom connections FUNCTIONAL DIAGRAM The transceiver module receives 4 channels of 25 Gbps electrical data, which are processed by a 4-channel Clock and Data Recovery (CDR) IC that reshapes and reduces the jitter of each electrical signal. Subsequently, each of 4 EML laser driver IC's converts one of the 4 channels of electrical signals to an optical signal that is transmitted from one of the 4 cooled EML lasers which are packaged in the Transmitter Optical Sub-Assembly (TOSA). Each laser launches the optical signal in specific wavelength specified in IEEE802.3ba 100GBASE-LR4 requirements. These 4 lane optical signals will be optically multiplexed into a single fiber by a 4-to-1 optical WDM MUX. The optical output power of each channel is maintained constant by an automatic power control (APC) circuit. The transmitter output can be turned off by TX_DIS hardware signal and/or 2-wire serial interface. Rx3 Rx2 Rx1 Rx0 RX CDR ROSA DEMUX Figure 1. Functional diagram Page 2 of 9

The receiver receives 4-lane LAN WDM optical signals. The optical signals are demultiplexed by a 1-to-4 optical DEMUX and each of the resulting 4 channels of optical signals is fed into one of the 4 receivers that are packaged into the Receiver Optical Sub- Assembly (ROSA). Each receiver converts the optical signal to an electrical signal. The regenerated electrical signals are retimed and de-jittered and amplified by the RX portion of the 4-channel CDR. The retimed 4-lane output electrical signals are compliant with IEEE CAUI-4 interface requirements. In addition, each received optical signal is monitored by the DOM section. The monitored value is reported through the 2-wire serial interface. If one or more received optical signal is weaker than the threshold level, RX_LOS hardware alarm will be triggered. A single +3.3V power supply is required to power up this product. Both power supply pins VccTx and VccRx are internally connected and should be applied concurrently. As per MSA specifications the module offers 7 low speed hardware control pins (including the 2-wire serial interface): ModSelL, SCL, SDA, ResetL, LPMode, ModPrsL and IntL. Module Select (ModSelL) is an input pin. When held low by the host, this product responds to 2-wire serial communication commands. The ModSelL allows the use of this product on a single 2-wire interface bus individual ModSelL lines must be used. Serial Clock (SCL) and Serial Data (SDA) are required for the 2-wire serial bus communication interface and enable the host to access the QSFP28 memory map. The ResetL pin enables a complete reset, returning the settings to their default state, when a low level on the ResetL pin is held for longer than the minimum pulse length. During the execution of a reset the host shall disregard all status bits until it indicates a completion of the reset interrupt. The product indicates this by posting an IntL (Interrupt) signal with the Data_Not_Ready bit negated in the memory map. Note that on power up (including hot insertion) the module should post this completion of reset interrupt without requiring a reset. Low Power Mode (LPMode) pin is used to set the maximum power consumption for the product in order to protect hosts that are not capable of cooling higher power modules, should such modules be accidentally inserted. Module Present (ModPrsL) is a signal local to the host board which, in the absence of a product, is normally pulled up to the host Vcc. When the product is inserted into the connector, it completes the path to ground through a resistor on the host board and asserts the signal. ModPrsL then indicates its present by setting ModPrsL to a Low state. Interrupt (IntL) is an output pin. Low indicates a possible operational fault or a status critical to the host system. The host identifies the source of the interrupt using the 2-wire serial interface. The IntL pin is an open collector output and must be pulled to the Host Vcc voltage on the Host board. ABSOLUTE MAXIMUM RATINGS Parameter Symbol Min Max Unit Storage Temperature Ts -40 +85 degc Operating Case Temperature TOP 0 70 degc Power Supply Voltage Vcc -0.5 3.6 V Relative Humidity (non-condensation) RH 0 85 % Damage Threshold, each Lane THd 5.5 dbm Page 3 of 9

RECOMMENDED OPERATING CONDITIONS Operating Case Temperature TOP 0 70 degc Power Supply Voltage Vcc 3.135 3.3 3.465 V Data Rate, each Lane 25.78125 Gb/s Control Input Voltage High) 2 Vcc V Control Input Voltage Low 0 0.8 V Link Distance with G.652 D 0.002 10 km RECOMMENDED POWER SUPPLY FILTER Page 4 of 9

ELECTRICAL CHARACTERISTICS Power Consumption - 4.0 W Supply Current Icc 1.21 A Transceiver Power-on Initialization Time 2000 ms ELECTRICAL CHARACTERISTICS TRANSMITTER (EACH LANE) Single-ended Input Voltage Tolerance (Note 2) -0.3 4.0 V AC Common Mode Input Voltage Tolerance 15 mv Differential Input Voltage Swing Threshold 50 mvpp Differential Input Voltage Swing Vin.pp 190 700 mvpp Differential Input Impedance Zin 90 100 110 Ω ELECTRICAL CHARACTERISTICS RECEIVER Single-ended Output Voltage -0.3 4.0 V AC Common Mode Output Voltage 7.5 mv Differential Output Voltage Swing Vout.pp 300 850 mvpp Differential Output Impedance Zout 90 100 110 ohm Notes: 1. Power-on Initialization Time is the time from when the power supply voltages reach and remain above the minimum recommended operating supply voltages to the time when the module is fully functional. 2. The single ended input voltage tolerance is the allowable range of the instantaneous input signals. OPTICAL CHARACTERISTICS L0 1294.53 1295.56 1296.59 nm Lane Wavelength L1 L2 1299.02 1303.54 1300.05 1304.58 1301.09 1305.63 nm nm L3 1308.09 1309.14 1310.19 nm Page 5 of 9

OPTICAL CHARACTERISTICS TRANSMITTER Notes Side-mode Suppression Ratio SMSR 30 db Total Average Launch Power P T 10.5 dbm Average Launch Power (each Lane) PAVG -4.3 4.5 dbm Optical Modulation Amplitude (each Lane) POMA -1.3 4.5 dbm 1 Difference in Launch Power between any two Lanes (OMA) Launch Power in OMA minus Transmitter and Dispersion Penalty (TDP), each Lane Ptx,diff 5 db -2.3 dbm TDP, each Lane TDP 2.2 db Extinction Ratio ER 4 db Relative Intensity Noise RIN -130 db/hz Optical Return Loss Tolerance TOL 20 db Transmitter Reflectance R T -12 db Eye Mask {X1, X2, X3, Y1, Y2, Y3} {0.25, 0.4, 0.45, 0.25, 0.28, 0.4} 2 Average Launch Power OFF (each Lane) P off -30 dbm Note: Transmitter optical characteristics are measured with a single mode fiber. Page 6 of 9

OPTICAL CHARACTERISTICS RECEIVER Notes Damage Threshold (each Lane) THd 5.5 dbm 3 Total Average Receive Power 10.5 dbm Average Power at Receiver, each Lane -10.6 4.5 dbm Receive Power (OMA) (each Lane) 4.5 dbm Receiver Sensitivity (OMA), each Lane SEN 8.6 dbm Stressed Receiver Sensitivity (OMA), each Lane -6.8 dbm 4 Difference in Receive Power between any two Lanes Prx,diff 5.5 db (OMA) LOS Assert LOSA -18 dbm LOS Deassert LOSD -15 dbm LOS Hysteresis LOSH 0.5 db Receiver Electrical 3 db upper Cutoff Frequency, each Fc 31 GHz Lane Vertical Eye Closure Penalty, each Lane 1.8 db Stressed Eye J2 Jitter, each Lane 0.3 UI Stressed Eye J9 Jitter, each Lane 0.47 UI Note: The receiver shall be able to tolerate, without damage, continuous exposure to a modulated optical input signal having this power level on one lane. The receiver does not have to operate correctly at this input power. DIGITAL DIAGNOSTIC FUNCTIONS The following digital diagnostic characteristics are defined over the normal operating conditions unless otherwise specified. Notes Temperature monitor absolute error DMI TEMP -3 3 deg. C Over operating temperature range Supply voltage monitor absolute error DMI VCC -0.1 0.1 V Over Full operating range Channel RX power monitor absolute error DMI RX_CH -2 2 db 1 Channel Bias current monitor DMI Ibias_CH -10% 10% ma Channel TX power monitor absolute error DMI TX_CH -2 2 db 1 Page 7 of 9

PIN ASSIGNMENT AND FUNCTION DEFINITIONS PIN Assignment PIN Definition PIN Signal Name Description PIN Signal Description Name 1 GND Ground (1) 20 GND Ground (1) 2 Tx2n CML-I Transmitter 2 Inverted Data Input 21 Rx2n CML-O Receiver 2 Inverted Data Output 3 Tx2p CML-I Transmitter 2 Non-Inverted Data Input 22 Rx2p CML-O Receiver 2 Non-Inverted Data Output 4 GND Ground (1) 23 GND Ground (1) 5 Tx4n CML-I Transmitter 4 Inverted Data Input 24 Rx4n CML-O Receiver 4 Inverted Data Output 6 Tx4p CML-I Transmitter 4 Non-Inverted Data Input 25 Rx4p CML-O Receiver 4 Non-Inverted Data Output 7 GND Ground (1) 26 GND Ground (1) 8 ModSelL LVTLL-I Module Select 27 ModPrsL Module Present 9 ResetL LVTLL-I Module Reset 28 IntL Interrupt 10 V CCR x +3.3V Power Supply Receiver (2) 29 V CCTx +3.3V Power Supply Transmitter (2) 11 SCL LVCMOS-I/O 2-Wire Serial Interface Clock 30 V CC1 +3.3V Power Supply 12 SDA LVCMOS-I/O 2-Wire Serial Interface Data 31 LPMode LVTLL-I Low Power Mode 13 GND Ground (1) 32 GND Ground (1) 14 Rx3p CML-O Receiver 3 Non-Inverted Data Output 33 Tx3p CML-I Transmitter 3 Non-Inverted Data Input Page 8 of 9

15 Rx3n CML-O Receiver 3 Inverted Data Output 34 Tx3n CML-I Transmitter 3 Inverted Data Input 16 GND Ground (1) 35 GND Ground (1) 17 Rx1p CML-O Receiver 1 Non-Inverted Data Output 36 Tx1p CML-I Transmitter 1 Non-Inverted Data Input 18 Rx1n CML-O Receiver 1 Inverted Data Output 37 Tx1n CML-I Transmitter 1 Inverted Data Input 19 GND Ground (1) 38 GND Ground (1) Notes: 1. All Ground (GND) are common within the QSFP+ module and all module voltages are referenced to this potential unless noted otherwise. Connect these directly to the host board signal common ground plane. 2. V ccrx, Vcc1 and V cctx are the receiving and transmission power suppliers and shall be applied concurrently. The connector pins are each rated for a maximum current of 500mA. MECHANICAL DRAWING Page 9 of 9