DuPont Self-Adhered Flashing Systems Installation Guidelines

DuPont Flashing Systems Installation Guidelines. INstallation instructions after water-resistive. Version 2

DuPont Flashing Systems Installation Guidelines

DuPont Flashing Systems Installation Guidelines

DuPont Flashing Systems Installation Guidelines

DuPont Flashing Systems Installation Guidelines

DuPont Flashing Systems Installation Guidelines. Version 2

DuPont Flashing Systems Installation Guidelines. Version 2

DuPont Self-Adhered Flashing Systems Products

DuPont Flashing Systems Installation Guidelines. Version 2

DuPont Flashing Systems Installation Guidelines

DuPont Flashing Systems Installation Guidelines. Integral Flanged Door Before water-resistive. Version 2

DuPont Flashing Systems Commercial Installation Guidelines

DuPont Flashing Systems Commercial Installation Guidelines

DuPont Tyvek Fluid Applied Flashing Commercial Installation Guidelines

DUPONT TYVEK FLUID APPLIED FLASHING INSTALLATION GUIDELINES METHODS FOR SUPERIOR PROTECTION AGAINST AIR AND WATER INTRUSION

TYPAR WEATHER PROTECTION SYSTEM TABLE OF CONTENTS. SPECIAL INSTALLATION CONSIDERATIONS Stucco** Brick** Stone Veneer** Wood Siding**

ForceField Air & Water Barrier System. installation instructions

RECOMMENDED INSTALLATION PROCEDURE LEVEL 3

RECOMMENDED INSTALLATION PROCEDURE LEVEL 3

Sun Windows General Information New Construction Hinged Door Installation Instructions

Installation Instructions

Eagle clad double-hung window installation instructions

Building Wrap and Flashing

Read guide from beginning to end before starting installation. Read all warnings and cautions during unit installation.

Sun Windows General Information New Construction Sliding Door Installation Instructions H F

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001) IMPORTANT INFORMATION & GLOSSARY ROUGH OPENINGS

Building Wrap and Flashing

All Window Installation Instruction

Show them you're an InstallationMaster, and watch your business grow. InstallationMasters Training Manual Addendum Level RLC-1

Installation Guide. for E-Series/Eagle Clad Hinged Inswing French Door

Providing 3 Layers of Protection

Flashing Materials. Rough Opening Preparation

RECOMMENDED INSTALLATION PROCEDURE LEVEL 3

window installation Guide wood FRaMinG New Construction

Tools required by installer: Materials required by installer:

HydroGap Drainable Housewrap: Installation Instructions

3M Air and Vapour Barrier 3015 Technical guide

Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit.

Features & Benefits: For Use with OSI QUAD Window & Door System. Recommended For:

Installation Guidelines For ALUMINUM M-SERIES 3 PANEL SLIDING DOOR

Best Materials LLC distributes backer rod, caulking and sealants for all types of EIFS joints and penetration sealing applications.

INSTALLATION INSTRUCTIONS for Wood/Clad Wood Windows without Exterior Trim or Nailing Fin (JII025) ImpOrTaNT INFOrmaTION & GlOssary.

INSTALLATION INSTRUCTIONS for Wood/Clad Wood Windows with Exterior Trim or Nail Fin (JII024)

Before installation, check your local and state requirements for this type of install.

Butyl Flash. Installation Instructions. Prep & General Conditions

(773) INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001) IMPORTANT INFORMATION & GL OSSARY ROUGH OPENINGS

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001)

Fold-A-Way Patio Door ASSEMBLY & INSTALLATION GUIDE

STACKING MULTI-SLIDE DOOR SYSTEM INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS IMPERVIA SLIDING PATIO DOOR WITH FINS

Installation of Fiberglass Windows

WindowSeal. Installation Instructions. Prep & General Conditions

In the 30-plus years that I ve been a remodeling contractor, I ve

Installation Guidelines. Next Dimension. Single Hung / Single Hung Fixed / Double Hung / Sliding Window / Fixed Window

INSTALLATION INSTRUCTIONS for Vinyl Projecting Windows with Integral Nailing Fin (JII023) IMPORTANT INFORMATION AND GLOSSARY ROUGH OPENINGS

UNIT 5: EXTERIOR DOORS AND WINDOWS

Installation Guide for E-Series/Eagle Clad Mechanically Fastened Windows

INSTALLATION INSTRUCTIONS for Vinyl Projecting Windows with Integral Nailing Fin (JII023)

Integrity Polygon and Round Top Installation and Finishing Instructions

Installation Recommendations for Finless Frame Doors

Norwood Windows Permaglass Fiberglass Products Installation Instruction

INSTALLATION INSTRUCTIONS for Wood Bay or Bow Windows with Nailing Fin or Exterior Trim (JII032)

Vinyl Windows and Doors Manufactured by Pella Corporation

WEB BASED CORE APPLICATION SPECIFIC INSTALLATION INFORMATION AND METHODS

INSTALLATION INSTRUCTIONS for Wood Bay or Bow Windows with Nailing Fin or Exterior Trim (JII032) IMPORTANT INFORMATION AND GLOSSARY ROUGH OPENINGS

DOOR INSTALLATION GUIDE WOOD FRAMING New Construction

How To Install Windows: Nail-Fin Application

900 SERIES WALL PANELS

INSTALLATION INSTRUCTIONS for Wood/Clad Wood Windows without Exterior Trim or Nail Fin (JII025) IMPORTANT INFORMATION AND GLOSSARY ROUGH OPENINGS

INSTALLATION INSTRUCTIONS DOUBLE-HUNG WINDOW WITH FINS

INSTALLATION INSTRUCTIONS - INSTRUCCIONES DE INSTALACION FOR HURRICANESHIELD IMPACT-RESISTANT DOUBLE-HUNG, SINGLE-HUNG AND SIMULATED-HUNG

NEW CONSTRUCTION, REPLACEMENT AND FLUSH FIN REPLACEMENT WINDOW INSTALLATION INSTRUCTIONS

4. Partially open the operating panel and tilt the top toward the interior of the door (Figure 4). Lift the panel off the sill and set it aside.

INSTALLATION INSTRUCTION FOR WOOD DOUBLE-HUNG AND CASEMENT WINDOWS USING WOOD BRICKMOULD OR FLAT CASING

Installation Instructions for Vinyl Windows with Integral Nailing Fin (JII001)

French. Doors. Installing. In California, contractors have been

Metal & Vinyl, Flush Mount and Recessed Fin Windows Recommended Installation Instructions

Installation Instructions for Standard Lap and Self-Aligning Lap Siding

THERMO-FIT REPLACEMENT WINDOW INSTALLATION INSTRUCTIONS (BRICKMOULD / NO NAILING FLANGE)

Installation Materials Required: Tools Required: 6" self-adhesive flashing. Shims. 3-foot level 6-foot level Tape measure 1/8" drill bit

Installation Guide - Evolution Series Wood Siding

New Window. in an Old Opening. A leak-free installation depends on compatible materials and multiple layers of defense

INSTALLATION GUIDE WOOD PIVOTING CIRCLE/ OVAL

Sliding Glass Door Assembly and Installation Guide

INSTALLATION INSTRUCTIONS for Fiberglass Sliding Patio Doors with Applied Nailing Fin (JII104) IMPORTANT INFORMATION AND GLOSSARY

StormMaster Slate General Instructions 1.) GENERAL INSTRUCTIONS 2.) ROOF DECK VENTILATION 3.) ROOF DECK

PRIMED STRAND REVERSIBLE SHAKE

INSTALLATION GUIDELINES: X25 SERIES using perimeter installation fin

INSTALLATION INSTRUCTIONS IMPERVIA (Vent and Fixed) AWNING, CASEMENT, and LARGE AWNING WINDOW WITH FINS

Aluminum Clad Wood Window 1/2 Reinforced Field Mulling and Stacking Supplement

United States 32" Features and Benefits of WEATHERMATE Sill Pan

FMA/AAMA/WDMA Installation Update FMA Spring Conference Duck Key, Florida April 27, 2010

Installation Instructions for Wood/Clad Wood Windows with Exterior Trim or Nail Fin (JII024)

INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACIÓN FOR CLAD CASEMENT & AWNING WINDOW VENTANA DE DOS HOJAS CON REVESTIMIENTO

FOLDING DOOR - FOR FACTORY ASSEMBLED JAMBS WITH APPLIED SILL

A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS

Self-Adhering Reflective Sheet Membrane

CFDTT-01. Control Joint Study (General)

Windows Installed into Walls with Polyiso and Wood Framing. Installation Instructions Picture Frame Method Revised 10/24/2016

Transcription:

Installation Instructions for Windows and oors FTER Water-Resistive arrier (WR) is Installed upont Self-dhered Flashing Systems Installation Guidelines INSTLLTION INSTRUTIONS FOR WINOWS N OORS FTER WTER-RESISTIVE RRIER (WR) IS INSTLLE FOR UILINGS LESS THN 5 STORIES N LOW-RISE MULTI- FMILY RESIENTIL UILINGS LESS THN 6 STORIES REVISION 11/17

upont Self-dhered Flashing Systems Installation Guidelines Table of ontents pplicable Products... 2 Required Materials ased on Project Requirements, etails, and Specifications*... 3 Warranty... 3 General Instructions... 3 Key Installation Requirements for rainable Window / oor Installation Under the Limited Product and Labor Warranty... 4 Integral Flanged Window FTER upont Tyvek WR is Installed... 5 Integral Flanged djacent Rectangular Windows FTER upont Tyvek WR is Installed... 10 rip ap Installation with Integral Flanged Windows and oors... 21 Integral Flanged oor FTER upont Tyvek WR is Installed... 26 rick Mold Window FTER upont Tyvek WR Is Installed... 32 pplicable Products upont Self-dhered Flashing Systems Products PROUT upont FlexWrap NF upont FlexWrap EZ upont StraightFlash upont StraightFlash VF upont Flashing Tape Water-Resistive arriers (WR) WITH 6 in 9 in 2.75 in 4 in 9 in 6 in 4 in 6 in 9 in 12 in rick Mold oor FTER upont Tyvek WR Is Installed... 38 Field pplied Flanged Window FTER upont Tyvek WR Is Installed... 46 Field pplied Flanged oor FTER upont Tyvek WR Is Installed... 53 Non-Flanged Window FTER upont Tyvek WR Is Installed... 62 Non-Flanged oor FTER upont Tyvek WR Is Installed... 67 Integral Flanged Window with a Wood uck ump-out FTER upont Tyvek WR is Installed... 76 PROUT IMENSIONS RE upont Tyvek HomeWrap 3 ft x 100 ft 3 ft x 165 ft 5 ft x 200 ft 9 ft x 100 ft 9 ft x 150 ft 10 ft x 100 ft 10 ft x 150 ft 300 sq ft 495 sq ft 1,000 sq ft 900 sq ft 1,350 sq ft 1,000 sq ft 1,500 sq ft upont Tyvek StuccoWrap 5 ft x 200 ft 1,000 sq ft upont Tyvek rainwrap upont Tyvek ThermaWrap LE upont Tyvek ommercialwrap upont Tyvek ommercialwrap 9 ft x 125 ft 10 ft x 125 ft 5 ft x 150 ft 9 ft x 100 ft 5 ft x 200 ft 10 ft x 125 ft 5 ft x 200 ft 10 ft x 125 ft 1,125 sq ft 1,250 sq ft 750 sq ft 900 sq ft 1,000 sq ft 1,250 sq ft 1,000 sq ft 1,250 sq ft opyright 2017 E. I. du Pont de Nemours and ompany. ll Rights Reserved. K-17934 Rev. 11/17 2

upont Self-dhered Flashing Systems Installation Guidelines Required Materials ased on Project Requirements, etails, and Specifications* PROUT upont Tyvek Tape upont Tyvek Wrap ap Fasteners or recommended fastening system upont Window & oor Foam upont Residential Sealant, or other recommended sealant upont dhesive/primer acker Rod rushes for Surface Preparation J-Roller *pply per manufacturers guidelines. For non upont products, upont assumes no liability in use of recommended products; installers need to evaluate suitability of recommended products in their end-use applications. Warranty Please refer to the upont Weatherization Products 10-Year Limited Warranty for uildings Less Than 5 Stories and Low-Rise Multi-Family Residential uildings Less Than 6 Stories. NOTE: In order to make a claim under the upont Weatherization Products 10-Year Limited Product and Labor Warranty, you must have met all of the terms and conditions of the warranty, including use of the applicable upont Installation Guidelines. In the event that a specific detail or installation technique is not covered in the upont Installation Guidelines at the time you are building, then the Key Installation Requirements outlined in this document must have been followed in order to make a claim under the warranty. It is in the sole discretion of upont to determine if full compliance with the Key Installation Requirements exists. Please contact upont or a upont Tyvek Specialist if you have any questions regarding any upont Installation Guideline. General Instructions These installation guidelines are intended for buildings less than 5 Stories and low-rise multi-family residential buildings less than 6 stories when performance requirements do not exceed STM E1677 (65 mph equivalent structural load and 15 mph equivalent wind-driven rain water infiltration), and window/door design ratings that do not exceed P45. upont self-adhered flashing systems products should be installed on clean, dry surfaces that are free of frost. Wipe surfaces to remove moisture, dirt, grease and other debris that could interfere with adhesion. pply pressure along entire surface of flashing for a good bond using firm hand pressure, J-roller, or alternate tool without sharp edges (such as a plastic carpet tuck tool) to assist with application of uniform pressure during installation of upont self-adhered flashing systems products. Remove all wrinkles and bubbles that may allow for water intrusion by smoothing surface and repositioning as necessary. When flashing the sill area for windows and doors, upont recommends the use of 6 wide upont FlexWrap NF for 2 x 4 framing and 9 wide upont FlexWrap NF for 2 x 6 framing. s an option, if a rigid back dam is desired, cut the corner back dam the length of the sill and nail into place on the interior edge of the sill prior to installation of upont FlexWrap NF. Then install upont FlexWrap NF over sill and corner guard back dam. If using 6 upont FlexWrap NF with optional rigid back dam, seal ends of corner guard with upont Residential Sealant or recommended sealant. oor and window rough sill framing must be level or slightly sloped to the exterior to ensure proper drainage to the exterior. This best practice ensures continuous support with positive slope to the exterior. upont self-adhered flashing systems products are not intended for throughwall flashing applications. In lieu of temporarily taping, upont Tyvek flaps at window head and jambs can be tucked under the upont Tyvek air and water barrier. upont Residential Sealant should be tooled flat to allow the natural curing process to create a concave joint. Please contact your local upont Tyvek Specialist for additional information and installation support. opyright 2017 E. I. du Pont de Nemours and ompany. ll Rights Reserved. K-17934 Rev. 11/17 3

upont Self-dhered Flashing Systems Installation Guidelines O NOT STRETH upont FlexWrap NF when installing along the length of sills or jambs. upont FlexWrap NF is only intended to be extended when covering corners or curved sections. upont self-adhered flashing systems products perform best when installed at temperatures above 25 F ( 4 ). void placing upont Tyvek Wrap ap Fasteners where flashing or upont Tyvek Tape will be installed; however, upont Tyvek Wrap ap Fasteners can be applied over the flashing. dverse weather conditions or cold temperatures may require use of a primer to promote adhesion of upont self-adhered flashing products to most common building materials. oncrete, masonry, and fiber-faced exterior gypsum board require the use of upont dhesive/primer. Please call 1-800-44-Tyvek (800-448-9835), visit www.weatherization.tyvek.com, or consult your local upont Tyvek Specialist for additional information and installation support. Key Installation Requirements for rainable Window / oor Installation Under the Limited Product and Labor Warranty When flashing windows or doors, the following principles must be followed: When installed properly, upont StraightFlash, upont FlexWrap NF, and upont Flashing Tape provide nail sealability at window/door openings to help protect critical window-wall interfaces. Metal sill pan flashing may be used, but must not replace flexible sill flashing that provides nail sealability. upont self-adhered flashing systems products comply with M 711-13, Voluntary Specification for Self dhering Flashing Used for Installation of Exterior Wall Fenestration Products, which has a modified version of STM 1970 that is more representative for vertical wall applications. irect water onto an acceptable air and water barrier drainage plane with an unobstructed path to the exterior of the wall. Provide a drainage path for any water intrusion through the window/door attachment system that collects at the sill. Properly integrate flashing with acceptable upont Tyvek WR in accordance with the details in this installation guideline. upont self-adhered flashing systems products must be applied with a minimum 2 lap onto the WR. upont requires that upont FlexWrap NF and StraightFlash be covered within nine months (270 days) of installation. upont requires that upont Flashing Tape be covered within four months (120 days) of installation. Ensure that window / door and flashing system design takes into account common factors that will impact performance, such as: limate considerations: Rainfall, Wind, Temperature (hot / cold cycles), Humidity uilding design: Window / Wall esign (overhangs, recessed openings, bumpouts), Wall ssembly (wood frame or masonry), Window System (wood or vinyl), New onstruction or Replacement Window drainage path UV exposure prior to the construction of the exterior facade Field testing the window / door and wall installation as a complete system is a recommended best practice. Use of trained installers is highly recommended. opyright 2017 E. I. du Pont de Nemours and ompany. ll Rights Reserved. K-17934 Rev. 11/17 4

upont Self-dhered Flashing Systems Installation Guidelines Integral Flanged Window FTER upont Tyvek WR is Installed This method applies to the following products: upont StraightFlash, upont FlexWrap NF and upont Flashing Tape STEP 1 Prepare the upont Tyvek WR for window installation:. Make an I-ut (Standard I-ut) in the upont Tyvek WR (modified I-ut is also accepted). For an I-ut, begin with a horizontal cut across the bottom and the top of the window frame (for round top windows, the cut should begin above the mull joint). From the center, cut straight down to the sill.. ut two 45 degree slits a minimum of 8 extending from the corner of the window head, up and away from the window opening. This will create a flap above the rough opening to expose sheathing or framing members to allow head flashing installation (see step 4). Flip head flap up and temporarily secure with upont Tyvek Tape. LTERNTE METHO TO SEURE HE FLP: In lieu of temporarily taping, the head flap can be tucked under the upont Tyvek WR. NOTE: Some windows and flashing widths may require longer slits.. Fold side flaps into rough opening and secure to inside wall. ut off excess flaps if desired. 8 Minimum Exterior Exterior lternate Method to Secure Head Flap 8 Minimum for Roundtop Windows opyright 2017 E. I. du Pont de Nemours and ompany. ll Rights Reserved. K-17934 Rev. 11/17 5

upont Self-dhered Flashing Systems Installation Guidelines STEP 2. ut upont FlexWrap NF at least 12 LONGER than width of rough opening sill (S). Use roll widths sufficient to achieve a minimum of 1 adhesion EYON where the window frame will be located, ensuring 2 3 adhesion onto the face of the wall.. Remove wide piece of release paper. Position on horizontal sill by aligning the inside edge of the narrow release paper with the face of the wall to ensure 2 3 of the FlexWrap NF will be adhered to the face of the wall with a minimum of 6 up each jamb. dhere into rough opening.. Remove narrow release paper.. Fan out FlexWrap NF at corners and adhere onto face of wall. ontinue adhering onto face of wall along sill. overage of upont FlexWrap NF should be 2 3 onto the face of the wall. No Gap in orner Window Jamb upont FlexWrap NF 3 (S) 5 4 1 2 WRONG Sill ORRET FRONT VIEW ORNER ETIL Sill Width + 12 inches 6 Minimum O NOT STRETH opyright 2017 E. I. du Pont de Nemours and ompany. ll Rights Reserved. K-17934 Rev. 11/17 6

upont Self-dhered Flashing Systems Installation Guidelines STEP 3 pply upont Residential Sealant, upont or recommended sealant, on three sides (jambs and head) as shown below. For Rectangular Windows STEP 4. Install window according to manufacturer s instructions.. ut two pieces of upont StraightFlash, upont FlexWrap NF, or upont Flashing Tape for jamb flashing extending 1 above window head flange and below bottom edge of sill flashing. Remove release paper and press tightly along sides of window frame. OPTIONL: If installing a drip cap as part of the window installation before the upont self-adhered flashing membrane at the window head flange, see rip ap Installation Section and refer to Option 1. NOTE: The vertical leg of the drip cap must not be taller than the window head flange when installing drip cap according to Option 1.. ut a piece of upont StraightFlash, upont FlexWrap NF, or upont Flashing Tape for head flashing long enough to extend beyond outer edges of jamb flashings. Remove release paper and install completely covering flange and adhering to exposed sheathing or framing members. OPTIONL: If installing a drip cap as part of the window installation, but after the window head flashing, see rip ap Installation Section and refer to Option 2. NOTE: Ensure proper shingling. upont StraightFlash, upont FlexWrap NF, or upont Flashing Tape at jambs must overlap the upont FlexWrap NF at the sill and adhere to the upont Tyvek WR below the sill. OPTIONL: pply upont Residential Sealant, or recommended sealant at sill with at least two (2) 2 gaps in the sealant bead for every 4 of window to allow for drainage. INORRET INORRET ORRET upont FlexWrap NF upont StraightFlash upont StraightFlash reverse flashed flush with upont overlaps upont opyright 2017 E. I. du Pont de Nemours and ompany. ll Rights Reserved. K-17934 Rev. 11/17 FlexWrap NF FlexWrap NF 7

upont Self-dhered Flashing Systems Installation Guidelines STEP 5. Flip down upper flap of upont Tyvek WR so it lays flat across head flashing.. ut ~1 strip of the upont Tyvek WR at lower horizontal edge of head flap.. t the head, continuous tape seams as shown with upont Tyvek Tape. O NOT TPE at bottom of window. NOTE: Skip-taping at head with a maximum of two (2) 2 gaps for every 3 of window is acceptable if an air barrier is not required or if additional drainage is desired. OPTIONL: If installing a drip cap FTER the upont Tyvek WR head flap is flipped down and sealed, see rip ap Installation Section and refer to Option 3. STEP 6 Final Step Install upont Residential Sealant, or recommended sealant, (and backer rod as necessary) around the window opening at the interior. It is also acceptable to use upont Window & oor Foam or recommended foam on jambs and head, but it should not be used at sill and 6 up the jambs from the sill. The seal created by the sealant (and backer rod as necessary) or foam will also serve as a back dam. upont Residential Sealant should be tooled flat to allow the natural curing process to create a concave shape. e sure that the sealant penetrates the grooves of the upont FlexWrap NF around the sill. NOTE: Installations that specify a window/door design rating of P45 or greater require extra precautions. See General Instructions for performance requirements exceeding this design rating. opyright 2017 E. I. du Pont de Nemours and ompany. ll Rights Reserved. K-17934 Rev. 11/17 8

upont Self-dhered Flashing Systems Installation Guidelines For Roundtop Windows STEP 4 NOTE: Follow rectangular window instructions (Steps 1 through 4) for proper installation of sill and jamb flashing prior to head flashing installation. Install head flashing. ut upont FlexWrap NF head flashing at least 12 LONGER than the arc length (H) of round-top window.. Remove both release papers and install to conform around top of window, covering entire mounting flange and adhering to exposed sheathing or framing members. Head flashing should overlap jamb flashings by at least 6. STEP 5. Flip down upper flap of upont Tyvek WR so it lays flat across head flashing.. ut ~1 strip of the upont Tyvek WR at lower horizontal edge of head flap.. Tape seams as shown. O NOT TPE at bottom of window. t the head, continuous tape seams as shown with upont Tyvek Tape. Skip-taping at the head is acceptable if an air barrier is not required or if additional drainage is desired. 6 Minimum (H) STEP 6 Final Step Install upont Residential Sealant, or recommended sealant, (and backer rod as necessary) around the window opening at the interior. It is also acceptable to use upont Window & oor Foam or recommended foam on jambs and head, but it should not be used at sill and 6 up the jambs from the sill. The seal created by the sealant (and backer rod as necessary) or foam will also serve as a back dam. upont Residential Sealant should be tooled flat to allow the natural curing process to create a concave shape. e sure that the sealant penetrates the grooves of the upont FlexWrap NF around the sill. NOTE: Installations that specify a window/ door design rating of P45 or greater require extra precautions. See General Instructions for performance requirements exceeding this design rating. opyright 2017 E. I. du Pont de Nemours and ompany. ll Rights Reserved. K-17934 Rev. 11/17 9

upont Self-dhered Flashing Systems Installation Guidelines Integral Flanged djacent Rectangular Windows FTER upont Tyvek WR is Installed This method applies to upont StraightFlash, upont FlexWrap NF and upont Flashing Tape STEP 1 Prepare upont Tyvek WR for window installation:. Make I-uts (Standard I-ut) in the upont Tyvek WR (modified I-uts are also accepted) for each adjacent window rough opening. For an I-ut, begin with a horizontal cut across the bottom and the top of the window frame. From the center, cut straight down to the sill.. ut the upont Tyvek WR along the top and bottom of the shared window framing and/or sheathing to connect the top and bottom of the I-uts as shown. Remove the upont Tyvek WR to expose the vertical sheathing/framing.. ut two 45 degree slits a minimum of 8 extending from each outside corners of the window rough openings, up and away from the window opening. This will create a flap above the adjacent window rough openings to expose sheathing or framing members to allow head flashing installation (see step 5). NOTE: Some windows and flashing widths may require longer slits. 8 Minimum opyright 2017 E. I. du Pont de Nemours and ompany. ll Rights Reserved. K-17934 Rev. 11/17 10

upont Self-dhered Flashing Systems Installation Guidelines. Flip head flap up and temporarily secure with upont Tyvek Tape. LTERNTE METHO TO SEURE HE FLP: In lieu of temporarily taping, the head flap can be tucked under the upont Tyvek WR. E. Fold the 2 side flaps into rough opening and secure to inside wall. ut off excess flaps if desired. E E lternate Method to Secure Head Flap opyright 2017 E. I. du Pont de Nemours and ompany. ll Rights Reserved. K-17934 Rev. 11/17 11

upont Self-dhered Flashing Systems Installation Guidelines Option 1 When Using upont Tyvek WR at Sheathing/Framing Separating djacent Windows Follow STEPS 2-5 when using a piece of upont Tyvek WR between the windows. Refer to djacent Window Option 2, when using upont self-adhered flashing products between adjacent windows.. Fold the two side flaps into rough opening, and secure. ut off excess flaps if necessary. STEP 2 Preparation of framing/sheathing separating adjacent windows using upont Tyvek WR.. ut a piece of upont Tyvek WR wide enough to cover the framing/sheathing between windows when wrapped into the window rough openings and 8" longer than the height of the rough opening.. ut corners to create side flaps that will fold into adjacent window rough openings with 2" of the Tyvek WR piece extending above the rough openings and 6" below.. Install Tyvek WR piece onto the framing/sheathing between windows. o not install fasteners within 6" of the rough openings. upont Tyvek Tape may be used if necessary to hold Tyvek WR piece in place. Seal vertical seams below window with upont Tyvek Tape. 2 H H+8 F 6 F opyright 2017 E. I. du Pont de Nemours and ompany. ll Rights Reserved. K-17934 Rev. 11/17 12

upont Self-dhered Flashing Systems Installation Guidelines Option 1 (continued) STEP 3. ut 2 pieces of upont FlexWrap NF at least 12 LONGER than width of rough opening sill (S). Use roll widths sufficient to achieve a minimum of 1 adhesion EYON where the window frame will be located, ensuring 2 3 adhesion onto the face of the wall.. Remove wide piece of release paper from the first piece of upont FlexWrap NF. Position on horizontal sill by aligning the inside edge of the narrow release paper with the face of the wall to ensure 2 3 of the FlexWrap NF will be adhered to the face of the wall with a minimum of 6 up each jamb. dhere into rough opening.. Remove narrow release paper from the upont FlexWrap NF.. Fan out upont FlexWrap NF at bottom corners onto face of wall and framing/ sheathing between windows. overage of upont FlexWrap NF should be 2 3 onto the face of the wall. E. Repeat Steps - for second window. NOTE: The upont FlexWrap NF installed in the second window may overlap the upont FlexWrap NF installed in the first window at the vertical exposed sheathing/framing separating the windows. No Gap in orner Window Jamb upont FlexWrap NF WRONG Sill ORRET FRONT VIEW ORNER ETIL 3 6 Minimum 5 4 1 2 E O NOT STRETH (S) Sill Width + 12 inches opyright 2017 E. I. du Pont de Nemours and ompany. ll Rights Reserved. K-17934 Rev. 11/17 13

upont Self-dhered Flashing Systems Installation Guidelines Option 1 (continued) STEP 4 pply upont Residential Sealant, upont or recommended sealant, on three sides (jambs and head) of each window as shown below. OPTIONL: pply upont Residential Sealant, or recommended sealant at sill with at least two (2) 2 gaps in the sealant bead for every 4 of window to allow for drainage. opyright 2017 E. I. du Pont de Nemours and ompany. ll Rights Reserved. K-17934 Rev. 11/17 14

upont Self-dhered Flashing Systems Installation Guidelines Option 1 (continued) STEP 5. Install windows according to manufacturer s instructions.. ut four pieces of upont StraightFlash, upont FlexWrap NF, or upont Flashing Tape for jamb flashing extending 1 above window head flanges and below bottom edge of sill flashing. Remove release paper and press tightly along sides of window frame. NOTE: The upont StraightFlash, upont FlexWrap NF, or upont Flashing Tape for the inside jamb flashing of one window may overlap the upont StraightFlash, upont FlexWrap NF, or upont Flashing Tape on the inside jamb of the other window. OPTIONL: If installing a drip cap as part of the window installation before the upont self-adhered flashing membrane at the window head flange, see rip ap Installation Section and refer to Option 1. The vertical leg of the drip cap must not be taller than the window head flange when installing drip cap according to Option 1.. ut a piece of upont StraightFlash, upont FlexWrap NF, or upont Flashing Tape for head flashing long enough to extend beyond edges of flashing at outer jambs. Remove release paper and adhere to head flanges, extending onto sheathing. The upont self-adhered membrane over the window must extend beyond the top edge of the upont self-adhered membrane previously installed between windows.. ontinue to STEP 6. NOTE: Ensure proper shingling. upont StraightFlash, upont FlexWrap NF, or upont Flashing Tape at jambs must overlap the upont FlexWrap NF at the sill and adhere to the Tyvek WR below the sill. OPTIONL: If installing a drip cap as part of the window installation, but after the window head flashing, see rip ap Installation Section and refer to Option 2. opyright 2017 E. I. du Pont de Nemours and ompany. ll Rights Reserved. K-17934 Rev. 11/17 15

upont Self-dhered Flashing Systems Installation Guidelines Option 2 When using upont self-adhered membrane at sheathing/ framing separating adjacent windows. STEP 2. ut 2 pieces of upont FlexWrap NF at least 12 LONGER than width of rough opening sill (S). Use roll widths sufficient to achieve a minimum of 1 adhesion EYON where the window frame will be located, ensuring 2 3 adhesion onto the face of the wall.. Remove wide piece of release paper from the first piece of upont FlexWrap NF. Position on horizontal sill by aligning the inside edge of the narrow release paper with the face of the wall to ensure 2 3 of the FlexWrap NF will be adhered to the face of the wall with a minimum of 6 up each jamb. dhere into rough opening.. Remove narrow release paper from the upont FlexWrap NF.. Fan out upont FlexWrap NF at bottom corners onto face of wall and framing/ sheathing between windows. overage of upont FlexWrap NF should be 2 3 onto the face of the wall. E. Repeat Steps - for second window. NOTE: The upont FlexWrap NF installed in the second window may overlap the upont FlexWrap NF installed in the first window at the vertical exposed sheathing/framing separating the windows. No Gap in orner Window Jamb upont FlexWrap NF WRONG Sill ORRET FRONT VIEW ORNER ETIL 6 Minimum 5 4 1 2 3 E O NOT STRETH (S) Sill Width + 12 inches opyright 2017 E. I. du Pont de Nemours and ompany. ll Rights Reserved. K-17934 Rev. 11/17 16

upont Self-dhered Flashing Systems Installation Guidelines Option 2 (continued) STEP 3. ut a piece of 9 wide upont StraightFlash or upont Flashing Tape 4 longer than the height of the rough opening.. Remove release paper and center the upont StraightFlash or upont Flashing Tape onto the face of the vertical exposed framing/sheathing with the bottom edge aligned with the sill rough opening. dhere the exposed butyl onto the face of the vertical exposed framing/sheathing and 4 above the window rough openings.. Make horizontal cuts in the upont StraightFlash or upont Flashing Tape along the top of the rough opening to the edge of the vertical framing/sheathing between windows.. Fold the resulting upont StraightFlash or upont Flashing Tape flaps into the rough opening and adhere. STEP 4 pply upont Residential Sealant, upont or recommended sealant, on three sides (jambs and head) of each window as shown below. 4 H H+4 OPTIONL: pply upont Residential Sealant, or recommended sealant at sill with at least two (2) 2 gaps in the sealant bead for every 4 opyright 2017 E. I. du Pont de Nemours and ompany. ll Rights Reserved. K-17934 Rev. 11/17 of window to allow for drainage. 17

upont Self-dhered Flashing Systems Installation Guidelines Option 2 (continued) STEP 5. Install windows according to manufacturer s instructions.. ut four pieces of upont StraightFlash, upont FlexWrap NF, or upont Flashing Tape for jamb flashing extending 1 above window head flanges and below bottom edge of sill flashing. Remove release paper and press tightly along sides of window frame. NOTE: The upont StraightFlash, upont FlexWrap NF, or upont Flashing Tape for the inside jamb flashing of one window may overlap the upont StraightFlash, upont FlexWrap NF, or upont Flashing Tape on the inside jamb of the other window. OPTIONL: If installing a drip cap as part of the window installation before the upont self-adhered flashing membrane at the window head flange, see rip ap Installation Section and refer to Option 1. The vertical leg of the drip cap must not be taller than the window head flange when installing drip cap according to Option 1.. ut a piece of upont StraightFlash, upont FlexWrap NF, or upont Flashing Tape for head flashing long enough to extend beyond edges of flashing at outer jambs. Remove release paper and adhere to head flanges, extending onto sheathing. The upont self-adhered membrane over the window must extend beyond the top edge of the upont self-adhered membrane previously installed between windows. NOTE: Ensure proper shingling. upont StraightFlash, upont FlexWrap NF, or upont Flashing Tape at jambs must overlap the upont FlexWrap NF at the sill and adhere to the Tyvek WR below the sill. OPTIONL: If installing a drip cap as part of the window installation, but after the window head flashing, see rip ap Installation Section and refer to Option 2. opyright 2017 E. I. du Pont de Nemours and ompany. ll Rights Reserved. K-17934 Rev. 11/17 18

upont Self-dhered Flashing Systems Installation Guidelines Option 2 (continued) STEP 6. Flip down upper flap of upont Tyvek WR so it lays flat across head flashing.. ut ~1 strip of the upont Tyvek WR at lower horizontal edge of head flap.. Tape seams as shown. O NOT TPE at bottom of window. t the head, continuous tape seams as shown with upont Tyvek Tape. Skip-taping at the head is acceptable if an air barrier is not required or if additional drainage is desired.. Tape down diagonal seams of upont Tyvek WR. OPTIONL: If installing a drip cap FTER the upont Tyvek WR head flap is flipped down and sealed, see rip ap Installation Section and refer to Option 3. opyright 2017 E. I. du Pont de Nemours and ompany. ll Rights Reserved. K-17934 Rev. 11/17 19

upont Self-dhered Flashing Systems Installation Guidelines Option 2 (continued) STEP 7 Final Step Install upont Residential Sealant or recommended sealant (and backer rod as necessary) around the window openings at the interior. It is also acceptable to use upont Window & oor Foam or recommended foam on jambs and head, but it should not be used at sill and 6 up the jambs from the sill. The seal created by the sealant (and backer rod as necessary) will also serve as a back dam. upont Residential Sealant should be tooled flat to allow the natural curing process to create a concave shape. e sure that the sealant penetrates the grooves of the upont FlexWrap NF around the sill. NOTE: Installations that specify a window/door design rating of P45 or greater require extra precautions. See General Instructions for performance requirements exceeding this design rating. opyright 2017 E. I. du Pont de Nemours and ompany. ll Rights Reserved. K-17934 Rev. 11/17 20

upont Self-dhered Flashing Systems Installation Guidelines rip ap Installation with Integral Flanged Windows and oors The following drip cap options can also be used for integral flanged doors. Option 1. over the head flange and top edge of the drip cap with a piece of upont StraightFlash, upont FlexWrap NF, or upont Flashing Tape. The upont self-adhered flashing systems product should be long enough to extend beyond the jamb flashing and adhere a minimum of 2 onto the wall. drip cap with a short vertical leg can be installed at the window head flange so it is integrated with the upont self-adhered flashing membrane installed at the head of the window EFORE the upont Tyvek WR head flap is flipped down and sealed. NOTE: When using this method, the vertical leg of the drip cap must not be taller than the window head flange when installed. STEP 1. fter the window is installed and jamb flashing applied, cut a piece of metal or vinyl drip cap slightly LONGER than the width of the window. Place a bead of upont Residential Sealant, or recommended sealant, on the rear side of the vertical leg N a bead on the rear side of the bottom horizontal leg. Install the drip cap tight against the window head flange. opyright 2017 E. I. du Pont de Nemours and ompany. ll Rights Reserved. K-17934 Rev. 11/17 21

upont Self-dhered Flashing Systems Installation Guidelines Option 1 (continued) STEP 2. Flip down upont Tyvek WR head flap so it lays flat across the upont StraightFlash, upont FlexWrap NF, or upont Flashing Tape covering the drip cap and window head flange.. ut ~1 strip of the upont Tyvek WR at lower horizontal edge of head flap.. Tape seams as shown. O NOT TPE at bottom of window. t the head, continuous tape seams as shown with upont Tyvek Tape. Skip-taping at the head is acceptable if an air barrier is not required or if additional drainage is desired.. Tape down diagonal seams of upont Tyvek WR. opyright 2017 E. I. du Pont de Nemours and ompany. ll Rights Reserved. K-17934 Rev. 11/17 22

upont Self-dhered Flashing Systems Installation Guidelines rip ap Installation with Integral Flanged Windows and oors Option 2 drip cap can be installed over the head flashing above the window head EFORE the upont Tyvek WR head flap is flipped down and sealed. STEP 1. fter the upont StraightFlash, upont FlexWrap NF, or upont Flashing Tape is installed over window head flange, cut metal or vinyl drip cap slightly LONGER than the width of the window.. Install the drip cap tight against the window head flashing and cover the top edge with upont StraightFlash, upont FlexWrap NF, or upont Flashing Tape extending past the top and sides of the drip cap. opyright 2017 E. I. du Pont de Nemours and ompany. ll Rights Reserved. K-17934 Rev. 11/17 23

upont Self-dhered Flashing Systems Installation Guidelines Option 2 (continued) STEP 2. Flip down upont Tyvek WR head flap so it lays flat across the upont StraightFlash, upont FlexWrap NF, or upont Flashing Tape covering the drip cap.. ut ~1 strip of the upont Tyvek WR at lower horizontal edge of head flap.. Tape seams as shown. O NOT TPE at bottom of window. t the head, continuous tape seams as shown with upont Tyvek Tape. Skip-taping at the head is acceptable if an air barrier is not required or if additional drainage is desired.. Tape down diagonal seams of upont Tyvek WR. opyright 2017 E. I. du Pont de Nemours and ompany. ll Rights Reserved. K-17934 Rev. 11/17 24

upont Self-dhered Flashing Systems Installation Guidelines rip ap Installation with Integral Flanged Windows and oors Option 3 drip cap can be installed over the upont Tyvek WR above the window head FTER the upont Tyvek WR head flap is flipped down and sealed. STEP 1. fter upont Tyvek WR head flap is flipped down and sealed, cut metal or vinyl drip cap slightly LONGER than the width of the window and install.. s a recommended best practice, cover the top edge of the drip cap with upont StraightFlash, upont FlexWrap NF, or upont Flashing Tape extending past the top and sides of the drip cap and side edges of the window head flashing. opyright 2017 E. I. du Pont de Nemours and ompany. ll Rights Reserved. K-17934 Rev. 11/17 25

upont Self-dhered Flashing Systems Installation Guidelines Integral Flanged oor FTER upont Tyvek WR is Installed This installation guideline is intended for doors installed above grade and/or with wood floor construction. This method applies to the following products: upont StraightFlash, upont FlexWrap NF and upont Flashing Tape STEP 1 Prepare upont Tyvek WR for door installation:. Make an I-ut (Standard I-ut) in the WR. For an I-ut, begin with a horizontal cut across the bottom and the top of the door frame. From the center, cut straight down to the sill.. ut two 45 degree slits a minimum of 8 extending from the corner of the door head up and away from door opening from the corner of the header, to create a flap above the rough opening to expose sheathing or framing members, to allow head flashing installation (see step 8). NOTE: Some doors and flashing widths may require longer slits.. Flip head flap up and temporarily secure with upont Tyvek Tape. LTERNTE METHO TO SEURE HE FLP: In lieu of temporarily taping, the head flap can be tucked under the upont Tyvek WR.. Fold side flaps into rough opening and secure to inside wall. ut off excess flaps if desired. 8 Minimum lternate Method to Secure Head Flap 8 Minimum opyright 2017 E. I. du Pont de Nemours and ompany. ll Rights Reserved. K-17934 Rev. 11/17 26

upont Self-dhered Flashing Systems Installation Guidelines STEP 2 Preparation of sill flashing:. ut upont FlexWrap NF at least 12 LONGER than width of rough opening sill (S). Use roll widths sufficient to achieve a minimum of 1 adhesion EYON where the window frame will be located, ensuring 2 3 adhesion onto the face of the wall.. 9 upont FlexWrap NF has perforated release paper to help with the formation of the back dam (see Step 9). To ensure that the perforation tears cleanly, fold the perforation 180 and crease the flashing.. Remove the two widest pieces of release paper leaving the narrowest release paper on the flashing. When the finished floor is applied, the release paper can be removed and the back dam can be completed. STEP 3. Position the sill flashing as indicated so the section with the release paper still attached extends past the door threshold on the inside. Ensure that 2 3 of the FlexWrap NF will be adhered to the face of the wall with a minimum of 6 up each jamb. dhere into rough opening. When the 1 of release paper is removed, the remaining section of upont FlexWrap NF can be used to form a back dam. OPTIONL: reate back dam by folding back narrow section of upont FlexWrap NF: Some flooring cannot accomodate a back dam. In that case fold the back dam on top of upont FlexWrap NF in the sill. The door will be installed on top of the fold to create a back dam (see Side View etail below). 6-inch for 2x4-inch studs 9-inch for 2x6-inch studs EXTERIOR INTERIOR oor Front Overlap Scored Release Paper oor Threshold Transition Threshold Flooring OPTION ack upont StraightFlash High Pressure Skirt (OPTIONL, See STEP 6) upont FlexWrap NF upont Tyvek WR Sub Floor orner Guard (optional) Sheathing (S) Sill Length + 12 inches reak Scored Release Paper Peel Off 2-pieces of Release Paper 5 6 Minimum 4 3 1 2 O NOT STRETH WRONG No Gap in orner oor Jamb upont FlexWrap NF Sill ORRET FRONT VIEW ORNER ETIL SIE VIEW ETIL opyright 2017 E. I. du Pont de Nemours and ompany. ll Rights Reserved. K-17934 Rev. 11/17 27

upont Self-dhered Flashing Systems Installation Guidelines STEP 4 Fan out FlexWrap NF at corners and adhere onto face of wall. ontinue adhering onto face of wall along sill. overage of upont FlexWrap NF should be 2 3 onto the face of the wall. STEP 5 pply upont Residential Sealant, or recommended sealant, on three sides (jambs and head) as shown below. OPTIONL: pply upont Residential Sealant, or recommended sealant at threshold with at least two (2) 2 gaps in the sealant bead for every 4 of door to allow for drainage. opyright 2017 E. I. du Pont de Nemours and ompany. ll Rights Reserved. K-17934 Rev. 11/17 28

upont Self-dhered Flashing Systems Installation Guidelines STEP 6 (OPTIONL) For extreme weather conditions, performance requirements exceeding STM E1677, or window/door design ratings of P45 or greater, see General Instructions.. reate the high pressure skirt by cutting a piece of upont Tyvek WR 1 wider than the width of door opening and approximately 10 in depth.. ut a 4 piece of upont StraightFlash or upont Flashing Tape to the same width as the skirt. Remove two pieces of release paper and adhere to the upont Tyvek WR.. Remove the last piece of release paper and attach the skirt to the underside of the door. This skirt may be made with upont StraightFlash, upont Flashing Tape, or upont StraightFlash VF. 4 upont StraightFlash 10 utyl dhesive ttach remaining exposed butyl to underside of door opyright 2017 E. I. du Pont de Nemours and ompany. ll Rights Reserved. K-17934 Rev. 11/17 29

upont Self-dhered Flashing Systems Installation Guidelines STEP 7. OPTIONL: dhere high pressure skirt to the bottom threshold of the door.. Install door according to manufacturer s instructions.. ut two pieces of upont StraightFlash, or upont FlexWrap NF, or upont Flashing Tape for jamb flashing extending 1 above door head flange and below bottom edge of sill flashing. Remove release paper and press tightly along sides of door frame. OPTIONL: If installing a drip cap as part of the door installation before the upont selfadhered flashing membrane at the door head flange, see rip ap Installation Section and refer to Option 1. The vertical leg of the drip cap must not be taller than the door head flange when installing drip cap according to Option 1.. ut a piece of upont StraightFlash, or upont FlexWrap NF, or upont Flashing Tape for head flashing, which extends beyond outer edges of jamb flashings. Remove release paper and install completely covering mounting flange and adhering to exposed sheathing or framing members (see ). OPTIONL: If installing a drip cap as part of the door installation, but after the door head flashing, see rip ap Installation Section and refer to Option 2. NOTE: Ensure proper shingling. upont StraightFlash or upont Flashing Tape must overlap upont FlexWrap NF and adhere to the upont Tyvek WR. INORRET upont FlexWrap NF reverse flashed INORRET upont StraightFlash flush with upont FlexWrap NF ORRET upont StraightFlash overlaps upont FlexWrap NF opyright 2017 E. I. du Pont de Nemours and ompany. ll Rights Reserved. K-17934 Rev. 11/17 30

upont Self-dhered Flashing Systems Installation Guidelines STEP 8. Flip down upper flap of upont Tyvek WR so it lays flat across head flashing.. ut ~1 strip of the upont Tyvek WR at lower horizontal edge of head flap.. t the head, continuous tape seams as shown with upont Tyvek Tape. Skiptaping at the head is acceptable if an air barrier is not required or if additional drainage is desired. O NOT TPE at bottom of door.. Tape down diagonal seams of upont Tyvek WR. OPTIONL: If installing a drip cap FTER the upont Tyvek WR head flap is flipped down and sealed, see rip ap Installation Section and refer to Option 3. STEP 9 Final Step. OPTIONL: When the interior flooring is ready to install, remove release paper and use Folding Option One or Two (shown below) to form back dam.. Install upont Residential Sealant, or recommended sealant, (and backer rod as necessary) around the window opening at the interior. It is also acceptable to use upont Window & oor Foam or recommended foam on jambs and head, but it should not be used at sill and 6 up the jambs from the sill. The seal created by the sealant (and backer rod as necessary) or foam will also serve as a back dam. upont Residential Sealant should be tooled flat to allow the natural curing process to create a concave shape. e sure that the sealant penetrates the grooves of the upont FlexWrap NF around the sill. NOTE: Installations that specify a window/door design rating of P45 or greater require extra precautions. See General Instructions for performance requirements exceeding this design rating. Folding Option One Folding Option Two OR Fold Out and Up Fold In and Up Fastening Option One Fastening Option Two OR Staples Tape opyright 2017 E. I. du Pont de Nemours and ompany. ll Rights Reserved. K-17934 Rev. 11/17 31

upont Self-dhered Flashing Systems Installation Guidelines rick Mold Window FTER upont Tyvek WR Is Installed This method applies to the following products: upont StraightFlash, upont StraightFlash VF, upont FlexWrap NF and upont Flashing Tape STEP 1 Prepare upont Tyvek WR for window installation:. Make an I-ut (Standard I-ut) in the upont Tyvek WR (modified I-ut is also accepted). For an I-ut, begin with a horizontal cut across the bottom and the top of the window frame. From the center, cut straight down to the sill.. ut two 45 degree slits a minimum of 8 extending from the corner of the window head, up and away from the window opening. This will create a flap above the rough opening to expose sheathing or framing members to allow head flashing installation. Flip head flap up and temporarily secure with upont Tyvek Tape. LTERNTE METHO TO SEURE HE FLP: In lieu of temporarily taping, the head flap can be tucked under the upont Tyvek WR. NOTE: Some windows and flashing widths may require longer slits.. Fold side flaps into rough opening and secure to inside wall. ut off excess flaps if desired. 8 Minimum Exterior Exterior lternate Method to Secure Head Flap 8 Minimum opyright 2017 E. I. du Pont de Nemours and ompany. ll Rights Reserved. K-17934 Rev. 11/17 32

upont Self-dhered Flashing Systems Installation Guidelines STEP 2. ut upont FlexWrap NF at least 12 LONGER than width of rough opening sill (S). Use roll widths sufficient to achieve a minimum of 1 adhesion EYON where the window frame will be located, ensuring 2 3 adhesion onto the face of the wall.. Remove wide piece of release paper. Position on horizontal sill by aligning the inside edge of the narrow release paper with the face of the wall to ensure 2 3 of the FlexWrap NF will be adhered to the face of the wall with a minimum of 6 up each jamb. dhere into rough opening.. Remove narrow release paper.. Fan out FlexWrap NF at corners and adhere onto face of wall. ontinue adhering onto face of wall along sill. overage of upont FlexWrap NF should be 2 3 onto the face of the wall. No Gap in orner Window Jamb upont FlexWrap NF 3 (S) 5 4 1 2 WRONG Sill ORRET FRONT VIEW ORNER ETIL Sill Width + 12 inches 6 Minimum O NOT STRETH opyright 2017 E. I. du Pont de Nemours and ompany. ll Rights Reserved. K-17934 Rev. 11/17 33

upont Self-dhered Flashing Systems Installation Guidelines STEP 3. Prepare head flashing by cutting a piece of upont StraightFlash VF at least 12" LONGER than the head length.. reak the scored release paper on one side of the head flashing by folding it back and forth upon itself.. enter the upont StraightFlash VF on the window head and position so that it contacts the window frame and interior side of the brick mold. Remove the outer release paper and adhere the flashing to the window frame. Use the inner release paper to form a tight seal in the corner.. Remove the inner release paper and adhere the flashing to the back of the brick mold. E. eginning at the junction of the jamb and head, and away from the corner, cut the upont StraightFlash VF at a 45 angle. F. Fold the newly created flashing flap down flat against the brick mold. G. Fold remaining head flashing flaps down and adhere to the jamb frame. E E F G rick Mold Perforated Release Paper utyl VIEW - Window Window Window Window Window opyright 2017 E. I. du Pont de Nemours and ompany. ll Rights Reserved. K-17934 Rev. 11/17 34

upont Self-dhered Flashing Systems Installation Guidelines STEP 4. Prepare jamb flashing by cutting a piece of upont StraightFlash VF at least 6" LONGER than the jamb.. reak the scored release paper on one side of the jamb flashing by folding it back and forth upon itself.. Position so that the upont StraightFlash VF contacts the window frame and interior side of the brick mold. Ensure that the jamb flashing is positioned 1-1/2 inch below the top edge of the head flashing. Jamb flashing adhesive must come in contact with head flashing adhesive and overlap by one-inch.. Remove the outer release paper and adhere the flashing to the window frame. Use the inner release paper to form a tight seal in the corner. E. Remove the inner release paper and adhere the flashing to the back of the brick mold. F. Repeat on opposite jamb. Make sure the adhesive on these pieces will overlap. 1-1/2 E Window Window Window opyright 2017 E. I. du Pont de Nemours and ompany. ll Rights Reserved. K-17934 Rev. 11/17 35

upont Self-dhered Flashing Systems Installation Guidelines STEP 5. eginning at the junction of the jamb and head, and away from the corner, cut the upont StraightFlash VF at a 45 angle. Repeat this procedure at the junction of the sill and jamb.. Fold cut jamb, sill and head corners flashing parallel to the window frame so that the jamb flashing lies flat.. Fold the newly created jamb flashing flaps down at all corners and adhere to the window frame. STEP 6. Install the window per manufacturer s instructions.. Remove the remaining release paper from the upont StraightFlash VF jamb flashing and press firmly to adhere the butyl adhesive to the upont Tyvek WR.. Remove the release paper at the head and adhere the upont StraightFlash VF to the wall surface. Window OPTIONL: pply upont Residential Sealant, or recommended sealant at sill with at least two (2) 2 gaps in the sealant bead for every 4 of window to allow for drainage. INORRET upont FlexWrap NF reverse flashed INORRET upont StraightFlash flush with upont FlexWrap NF ORRET upont StraightFlash overlaps upont FlexWrap NF NOTE: o not reverse shingle. upont StraightFlash must overlap upont opyright 2017 E. I. du Pont de Nemours and ompany. ll Rights Reserved. K-17934 Rev. 11/17 FlexWrap NF and adhere to the substrate. 36

upont Self-dhered Flashing Systems Installation Guidelines STEP 7. OPTIONL: over exposed butyl with upont StraightFlash, upont Flashing Tape or upont Tyvek Tape. OPTIONL: If installing a drip cap as part of the window installation EFORE the upont Tyvek WR head flap is flipped down and sealed, see rip ap Installation Section and refer to Option 2.. Flip down upper flap of upont Tyvek WR so it lays flat across head flashing.. ut ~1 strip of the upont Tyvek WR at lower horizontal edge of head flap.. Tape seams as shown. O NOT TPE at bottom of window. t the head, continuous tape seams as shown with upont Tyvek Tape. Skip-taping at the head is acceptable if an air barrier is not required or if additional drainage is desired. E. Tape down diagonal seams of upont Tyvek WR. OPTIONL: If installing a drip cap FTER the upont Tyvek WR head flap is flipped down and sealed, see rip ap Installation Section and refer to Option 3. STEP 8 Final Step Install upont Residential Sealant, or recommended sealant, (and backer rod as necessary) around the window opening at the interior. It is also acceptable to use upont Window & oor Foam or recommended foam on jambs and head, but it should not be used at sill and 6 up the jambs from the sill. The seal created by the sealant (and backer rod as necessary) or foam will also serve as a back dam. upont Residential Sealant should be tooled flat to allow the natural curing process to create a concave shape. e sure that the sealant penetrates the grooves of the upont FlexWrap NF around the sill. NOTE: Installations that specify a window/door design rating of P45 or greater require extra precautions. See General Instructions for performance requirements exceeding this design rating. E opyright 2017 E. I. du Pont de Nemours and ompany. ll Rights Reserved. K-17934 Rev. 11/17 37

upont Self-dhered Flashing Systems Installation Guidelines rick Mold oor FTER upont Tyvek WR Is Installed This installation guide is intended for doors installed above grade and/or with wood floor construction. This method applies to the following products: upont StraightFlash, upont StraightFlash VF, upont FlexWrap NF, and upont Flashing Tape STEP 1 Prepare the upont Tyvek WR for door installation:. Make an I-ut (Standard I-ut) in the upont Tyvek WR. For an I-ut, begin with a horizontal cut across the bottom and the top of the door frame. From the center, cut straight down to the sill.. ut two 45 degree slits a minimum of 8 extending from the corner of the door head, up and away from door opening. This will create a flap above the rough opening to expose sheathing or framing members to allow head flashing installation (see step 8). NOTE: Some doors and flashing widths may require longer slits.. Flip head flap up and temporarily secure with upont Tyvek Tape. LTERNTE METHO TO SEURE HE FLP: In lieu of temporarily taping, the head flap can be tucked under the upont Tyvek WR.. Fold side flaps into rough opening, and secure to inside wall framing. ut off excess flaps if desired. 8 Minimum lternate Method to Secure Head Flap 8 Minimum opyright 2017 E. I. du Pont de Nemours and ompany. ll Rights Reserved. K-17934 Rev. 11/17 38