Exo-planet transit spectroscopy with JWST/NIRSpec

Similar documents
Exoplanet transit, eclipse, and phase curve observations with JWST NIRCam. Tom Greene & John Stansberry JWST NIRCam transit meeting March 12, 2014

High Contrast Imaging using WFC3/IR

ARRAY CONTROLLER REQUIREMENTS

GPI INSTRUMENT PAGES

CHAPTER 6 Exposure Time Calculations

MIRI The Mid-Infrared Instrument for the JWST. ESO, Garching 13 th April 2010 Alistair Glasse (MIRI Instrument Scientist)

DESIGN NOTE: DIFFRACTION EFFECTS

F/48 Slit Spectroscopy

UV/Optical/IR Astronomy Part 2: Spectroscopy

An Investigation of Optimal Dither Strategies for JWST

DRD OPS-02. original signed by 25 March 2010 P. Jensen - ESA JWST Project Manager Date reference

Observational Astronomy

Gemini 8m Telescopes Instrument Science Requirements. R. McGonegal Controls Group. January 27, 1996

Performance Comparison of Spectrometers Featuring On-Axis and Off-Axis Grating Rotation

arxiv: v1 [astro-ph.im] 26 Mar 2012

Simulation team in Vienna. Joao Alves, Werner Zeilinger, Rainer Köhler, Michael Mach

Science Detectors for E-ELT Instruments. Mark Casali

Image Slicer for the Subaru Telescope High Dispersion Spectrograph

Presented by Jerry Hubbell Lake of the Woods Observatory (MPC I24) President, Rappahannock Astronomy Club

SOAR Integral Field Spectrograph (SIFS): Call for Science Verification Proposals

GMT Instruments and AO. GMT Science Meeting - March

GLAO instrument specifications and sensitivities. Yosuke Minowa

Cerro Tololo Inter-American Observatory. CHIRON manual. A. Tokovinin Version 2. May 25, 2011 (manual.pdf)

Radiometric Solar Telescope (RaST) The case for a Radiometric Solar Imager,

Performance of the HgCdTe Detector for MOSFIRE, an Imager and Multi-Object Spectrometer for Keck Observatory

Improving the Collection Efficiency of Raman Scattering

An integral eld spectrograph for the 4-m European Solar Telescope

OPAL Optical Profiling of the Atmospheric Limb

Southern African Large Telescope. RSS CCD Geometry

a simple optical imager

NIRSpec Performance Report NPR Calibration of the GWA position sensors Part I

STIS CCD Saturation Effects

6. Very low level processing (radiometric calibration)

MS260i 1/4 M IMAGING SPECTROGRAPHS

Oriel MS260i TM 1/4 m Imaging Spectrograph

PACS SED and large range scan AOT release note PACS SED and large range scan AOT release note

METHOD FOR CALIBRATING THE IMAGE FROM A MIXEL CAMERA BASED SOLELY ON THE ACQUIRED HYPERSPECTRAL DATA

VATTSpec Instructions Rev. 10/23/2015

SpectraPro 2150 Monochromators and Spectrographs

Kepler photometric accuracy with degraded attitude control: Simulation of White Paper Attitude

The predicted performance of the ACS coronagraph

Simulations of the STIS CCD Clear Imaging Mode PSF

Phase-2 Preparation Tool

NIRCam optical calibration sources

Wavelength Calibration Accuracy of the First-Order CCD Modes Using the E1 Aperture

MIRI 4-Quadrant Phase Mask Coronagraphs. Anthony Boccaletti & C. Cavarroc, P.-O. Lagage, P. Baudoz & the MIRI consortium

Laboratory Experiment of a High-contrast Imaging Coronagraph with. New Step-transmission Filters

COS: NUV and FUV Detector Flat Field Status

Properties of a Detector

ENGINEERING CHANGE ORDER ECO No. COS-058 Center for Astrophysics & Space Astronomy Date 2 March 2001 University of Colorado, Boulder Sheet 1 of 16

Wide-field Infrared Survey Explorer (WISE)

XTcalc: MOSFIRE Exposure Time Calculator v2.3

Baseline Tests for the Advanced Camera for Surveys Astronomer s Proposal Tool Exposure Time Calculator

SUPPLEMENTARY INFORMATION

Bruce Macintosh for the GPI team Presented at the Spirit of Lyot conference June 7, 2007

Order Overlap. A single wavelength constructively interferes in several directions A given direction can receive multiple wavelengths.

Nonlinearity in the Detector used in the Subaru Telescope High Dispersion Spectrograph

ECEN. Spectroscopy. Lab 8. copy. constituents HOMEWORK PR. Figure. 1. Layout of. of the

Master sky images for the WFC3 G102 and G141 grisms

FLAT FIELD DETERMINATIONS USING AN ISOLATED POINT SOURCE

Calibrating VISTA Data

A new Infra-Red Camera for COAST. Richard Neill - PhD student Supervisor: Dr John Young

This release contains deep Y-band images of the UDS field and the extracted source catalogue.

Superconducting Transition-Edge Sensors and Superconducting Tunnel Junctions for Optical/UV Time-Energy Resolved Single-Photon Counters

Reference and User Manual May, 2015 revision - 3

Technical Evaluation Report TAACOS: Target Acquisition with the TA1 Mirror

Chasing Faint Objects

Cosmic Origins Spectrograph Instrument Mini-Handbook for Cycle 13

On Axis Guiding and Real Time Autofocus Solutions

Selecting the NIR detectors for Euclid

Southern African Large Telescope. Prime Focus Imaging Spectrograph. Instrument Acceptance Testing Plan

High-contrast imaging with E-ELT/HARMONI

On spatial resolution

High Speed Hyperspectral Chemical Imaging

The DSI for Autostar Suite

True simultaneous ICP-OES for unmatched speed and performance

ENGINEERING CHANGE ORDER ECO No. COS-057 Center for Astrophysics & Space Astronomy Date 13 February 2001 University of Colorado, Boulder Sheet 1 of 6

UltraGraph Optics Design

Next Generation Very Large Array Memo No. 47 Resolution and Sensitivity of ngvla-revb. C.L. Carilli (NRAO)

When, why and how to self-cal Nathan Brunetti, Crystal Brogan, Amanda Kepley

1.6 Beam Wander vs. Image Jitter

Superior ICP-OES optical design for unmatched speed and performance

Improved Spectra with a Schmidt-Czerny-Turner Spectrograph

Information for users of the SOAR Goodman Spectrograph Multi-Object Slit (MOS) mode. César Briceño and Sean Points

Application Note (A13)

WFC3/IR Channel Behavior: Dark Current, Bad Pixels, and Count Non-Linearity

Fast Solar Polarimeter

WITec Alpha 300R Quick Operation Summary October 2018

ENGINEERING CHANGE ORDER ECO No. COS-070 Center for Astrophysics & Space Astronomy Date 6 February 2002 University of Colorado, Boulder Sheet 1 of 3

COS Near-UV Flat Fields and High S/N Determination from SMOV Data

Teaching Time: Two 50-minute periods

Chapter 34 The Wave Nature of Light; Interference. Copyright 2009 Pearson Education, Inc.

Astrophysical Techniques Optical/IR photometry and spectroscopy. Danny Steeghs

Conceptual design for the High Resolution Optical Spectrograph on the Thirty-Meter Telescope: a new concept for a ground-based highresolution

Improvements to the STIS First Order Spectroscopic Point Source Flux Calibration

Technical Notes. Integrating Sphere Measurement Part II: Calibration. Introduction. Calibration

Table Of Contents. v Copyright by Richard Berry and James Burnell, All Rights Reserved.

Sideband Smear: Sideband Separation with the ALMA 2SB and DSB Total Power Receivers

The Flat Fielding and Achievable Signal-to-Noise of the MAMA Detectors 1

Design of a Free Space Optical Communication Module for Small Satellites

Transcription:

Exo-planet transit spectroscopy with JWST/NIRSpec P. Ferruit / S. Birkmann / B. Dorner / J. Valenti / J. Valenti / EXOPAG meeting 04/01/2014 G. Giardino / Slide #1

Table of contents Instrument overview / suggested mode for transit work. Generic; A1600 aperture; relevant features. Bright star limits. Computation; results; caveats / warnings. Target acquisition and pointing requirements. Pointing requirements; baseline and bright object TA. Operational timeline and limitations. Timeline; limitations. Simulations. What for?; photon noise floor; some systematics; Slide #2

Instrument overview NIRSpec in a nutshell NIRSpec (Near-InfraRed Spectrograph) is part of ESA s contribution to JWST. To fulfill its share of JWST science goals, NIRSpec had to have the following capabilities: Deep multi-object spectroscopy at low (around 100) and medium (around 1000) resolution over a wide field of view. è NIRSpec s MOS mode. Spatially-resolved, single-object spectroscopy at high (a few thousands) spectral resolution over a small (a few arc seconds) field of view. è NIRSpec s IFU mode. High-contrast slit spectroscopy at various spectral resolutions, including an aperture for extra-solar planet transit observations. è NIRSpec s SLIT mode. Slide #3

Instrument overview NIRSpec in a nutshell Slide #4

Instrument overview NIRSpec in a nutshell high Actually extends up to the detector cut-off wavelength (5.3-5.4 microns). Overlap with MIRI. Configurations that can be obtained thanks to a combination of filters and dispersers installed on two wheels (FWA and GWA) Slide #5

Instrument overview NIRSpec in a nutshell SLIT A complex field-of-view layout A1600 MOS MOS SLIT IFU MOS MOS Slide #6

Instrument overview NIRSpec in a nutshell Layout in the detector plane: MOS+SLIT short spectra Detector #1 (SCA491) Gap between the detectors corresponding to approximately 145 pixels. Detector #2 (SCA492) MOS SLIT A1600 Dedicated detector real-estate MOS Slide #7

Instrument overview NIRSpec in a nutshell - Detectors MULTIACCUM readout scheme presented yesterday. Three different modes: full-frame, stripe and window. Full-frame & stripe modes: 4 outputs read in parallel. Window mode: 1 output only. Slow readout direction = dispersion direction Slide #8

Instrument overview NIRSpec in a nutshell - Detectors NIRSpec s window mode (single output) and its rules One single rectangular window per SCA. The size of the windows must be identical in both SCAs but their origin can be different. The size of the window must be expressed as powers of 2 (e.g. 64 128) with a minimum size of 8 pixels along a given axis. The number of pixels in a window must be larger or equal to 1024. The idle time between exposures is ALWAYS filled with fullframe resets (4 outputs). Constraint linked to the design of the focal plane electronics. Strong change in dissipation power in the ASIC when switching between 1 and 4 outputs. è thermal disturbance between window-mode exposures (specific to NIRSpec). Slide #9

Instrument overview Spectroscopy with the A1600 aperture In order to accommodate the needs of transit spectroscopy, one of the 5 slits of NIRSpec has been turned into an aperture of 1.6 x 1.6 (labeled A1600). Can be used with all spectroscopic configurations. Large enough to get rid of systematics related to aperture losses. Not wide enough to use the spatial-scanning strategy recently used for HST spectroscopic observations. A1600 high-resolution spectrum for a point-source with a continuum spectrum Detector gap 2048 x 32 Note the missing wavelengths due to the detector gap in this high spectral resolution configuration (145 spectral pixels; 4 to 8e-2 microns). No gap at low/medium resolution (the spectra fit onto a single detector). Slide #10

Instrument overview Spectroscopy with the A1600 aperture The baseline for transit spectroscopy is to use sub-arrays (socalled window mode ). Full-frame readout time (4 outputs): 10.6 seconds. 2048x32 window (1 output): ~0.76 seconds. 512x32 window (1 output, short spectra): ~0.19 seconds. The baseline is to retrieve all the data (no on-board frame averaging). As we use a single output, data rate should not be an issue. The baseline is to use a minimum of 2 groups (i.e. a pair of readouts following a reset). No fixed number of groups. Single group option possible. A1600 spectrum for a point-source with a continuum spectrum Detector gap 2048 x 32 Slide #11

Instrument overview Spectroscopy with the A1600 aperture The PSF of JWST+NIRSpec exhibits a narrow diffractionlimited core over almost its complete wavelength range. This core is under-sampled by the 100mas pixels. Diffraction-limited core Fitting artifacts (due to speckles) Slide #12

Bright star limit Computation of the saturation limits for NIRSpec The rules Currently, the pixel saturation in NIRSpec is set by the ADC and this corresponds to roughly 77 000 electrons. The minimum integration contents is one reset followed by two reads and we do not want pixel saturation to be reached before the second read. 2048x32 (512x32) window for the grating (prism) modes. The inputs As required telescope collecting area and throughput. Using the JWST+NIRSpec photon conversion efficiency values presented at NIRSpec acceptance review. Taking the worst case of a PSF centered on a pixel. As these estimates are usually conservative in the wrong direction, the derived limiting fluxes have been decreased by 15% to be on the safe side. Need to have a consistent approach across the instruments Slide #13

Bright star limit Good coverage at high spectral resolution. Much stronger limitations at low spectral resolution. dashed = high resolution configurations See: http://www.cosmos.esa.int/web/jwst/exoplanets Sources below the lines can be observed in the full wavelength range of the given mode. The black symbols denote the host stars of known transiting exoplanets (data taken from exoplanets.org on 7 June 2013). The plot on the right shows the magnitude limits for the gratings in more detail. The difference in shape between the curves is due to the combined effect of i) using J-band magnitudes as the reference, ii) the spectral resolution of NIRSpec, and iii) the spectral energy distribution of the stars. Slide #14

Bright star limit Pushing the limit Pushing the limit. Tuning the detector gain to get rid of the limit set by the ADC and reach the real pixel saturation. à gain of 10-20 % (not large). Changing the detector bias level. à potentially a gain by a factor 2. Feasibility study conducted by B. Rauscher and his team using NIRSpec SCAs with the new design. Two SCAs have been tested including one which is in family with the selected flight SCAs (i.e. flight representative). Report posted on NGIN ( JWST NIRSpec High Bias for Increased Well Depth Test, B. Rauscher et al.). Slide #15

Bright star limit Pushing the limit Confirmed the results obtained by the team at ESO that the detectors are not damaged when the bias is pushed to 1V (baseline is 0.25V). Key performance elements when operating at high bias. Allows to achieve well depths of typically 180 000 electrons. Population of hot pixels increased by a factor 10. Major caveat. Anomalous persistence present during several hours after changing the bias voltage (one way or another). Typical wait-time of 6 hours before the persistence is back to acceptable levels. è On NIRSpec side, we consider this rules out using a high-bias mode as the baseline for the window mode (we want to preserve the capability to switch rapidly between full-frame and window mode). è Still the possibility for a campaign approach if scientifically justified. Slide #16

Target acquisition Accuracy of the positioning of the source A common misunderstanding is to mix up the needs in terms of source centering in the A1600 aperture and those in terms of stability of its positioning during the transit spectroscopy. Aperture is 16-pixel wide. Geometrical PSF losses are limited to a few percent. Need to have a fairly large offset (> 1 pixel = 100 mas) to increase them significantly. Note that percent-level modeling of the losses is tricky especially at short wavelengths where speckles contribute a lot. Robustness with respect to the source centering is expected to be quite good but has not yet been assessed. Expecting the 10-15 mas required accuracy of the baseline target acquisition to be much better than necessary in our case. à Work needed. à Baseline target acquisition may be usable even when the number of reference sources is fairly small. Slide #17

Target acquisition Bright Object Target Acquisition (BOTA) Recently STScI and the NIRSpec operation working group have been discussing the implementation of TA scheme specific to the A1600 aperture. Imaging the host star in the A1600 aperture, computing its centroid and using it to derive the slew necessary to center it. On-going discussion. Bright star limit in imaging is even more of a problem; need to use a 32x32 pixel window (minimum allowed size). Sanity check will be needed as the required initial pointing accuracy is still 1 arcsec (1 sigma). This is large compared to the size of the aperture. Actual accuracy is expected to be better than that. When should we use it? Criteria? è Work in progress. Slide #18

Operational timeline Credit: J. Valenti Slide #19

Operational timeline Credit: J. Valenti Slide #20

Constraints and disturbances. High-gain antenna repointing. [constraint] Every ~3 hours (10ks), 1 minute duration. Associated with a 100 mas perturbation during the repointing. Was initially associated to a mandatory change of visit (i.e. need to restart the timeline introducing huge disturbances). è Change not mandatory anymore thanks to the work of STScI (acquisition continues but data will be flagged as bad during the repointing). Maximum visit duration is now 1 day (to be confirmed) to allow momentum dump. Slide #21

Disturbances and constraints Maximum number of integrations per exposure. [constraint] Maximum of 65365 integrations per exposure. For the shortest integrations (reset-read-read) and the baseline window sizes this corresponds to 12.5 (49.2) hours for the prism (gratings). The problem is that we go back to full frame between exposures. Switching back to 4 outputs. Thermal disturbances in the detector system. è Do as much as possible within single exposures Slide #22

Disturbances and constraints Disturbances at the start of a visit. Slewing, moving mechanisms Starting an exposure Stabilization time needed. Need for a pause before starting the first exposure is TBD. The switch from idle to window mode could be a significant disturbance and this would be an argument to start the exposure immediately. Seems to have unwanted consequences on the operation side (activity with ill-defined duration). è Work in progress. Slide #23

Simulations Generic considerations Many different approaches possible depending on the scope of the simulations. Evaluation of the impact of the systematics. Getting some grip on the actual performances of the instrument. è focus of the presentation. See later. Advertise the capabilities of the instrument to the community. Provide inputs to the community so they can assess the feasibility of their own projects. è for me (PF) this should be the focus of a lot of the discussions at this meeting; I would advocate for a strong coordination to provide a JWST-level picture. Slide #24

Simulations Generic considerations Support development of specific ETCs. Linked to previous bullet. è discussion / coordination needed (so far the development of the ETCs is decoupled from the instrument teams). Support data challenges. è è timeline to be discussed; garbage in garbage out problem for this type of simulations; NIRSpec IPS software used to generate simulated raw exposures. Specific presentation today. Slide #25

Simulations Photon & readout noise floor and systematics Noise contributions Photon + readout noise Changes in aperture losses levels due to changes in the source position. Intra-pixel sensitivity changes. Accuracy of the flat-field correction PSF variations Unknowns! Key elements Noise floor. Provides a benchmark. Can be seen as NIRSpec specific (use of an aperture). NIRSpec PSF core is under-sampled. Not addressed in this presentation. Not addressed in this presentation. Slide #26

Simulations Photon & readout noise floor Very basic first step, gives you the theoretical limit. First assessment of what is possible or not, regardless of (poorly known) systematics. Provides a benchmark for the evaluation of the importance / impact of various disturbances. Large parameter space as the results depend a lot on the transit parameters. Generic cases: we will need to agree on their parameters to get a consistent picture from one instrument to the next. Examples: easier but we need to a agree on a set of examples and use cases. => sharing the same inputs and transit parameters. Simulations for the faint-end are fairly straight forward, things become more complicated at the bright end. Overheads become important and have some discrete jumps. The saturation limit is not constant with wavelength. Slide #27

Simulations Photon & readout noise floor SATURATION At the limit of what NIRSpec can do at low spectral resolution. Slide #28

Simulations Photon & readout noise floor A different view. Highlights the jumps associated to increases in the number of groups (and the associated increases in operational efficiency). The prism configurations correspond to a fairly extreme case. Slide #29

Simulations Photon & readout noise floor The situation is less extreme in the case of the gratings (lesser changes in spectral resolution). Slide #30

Simulations Simulations Photon & readout noise floor Balancing the signal to noise by playing with the number of groups per integration. Saturation takes place within an integration but we make sure it always takes place after the second read (so we have useful data for all wavelengths). Slide #31

Simulations A few words about pointing stability Understanding JWST pointing stability is critical if we want to assess the impact of systematics in NIRSpec s transit spectroscopy observations. Need to go deeper than the top level image motion requirement of 7 mas over 10ks. What happens when we push beyond 10 ks (see timeline discussion)? We need to understand what happens over very different time scales. Within one integration (< minute), from one integration to the next (several minutes to several tens of minutes), between in and out of transit (hours). Jitter versus drift Work in progress (at least on NIRSpec side). Slide #32

Simulations Changes in slit losses due to drifts Changes in the source centering within the A1600 aperture during a visit will change the radiometric response of the instrument. More concerned by long-term drifts than by random jitter during integrations. Prior to any calibration, changes at the 4x10-5 relative level are predicted for a drift level of 7 mas (1 sigma). Worst case as this is the complete image motion budget. Work conducted by B. Dorner (PhD thesis). Slide #33

Simulations Effect of intra-pixel sensitivity changes Looking at the impact of intra-pixel sensitivity. Using existing intra-pixel sensitivity maps provided by R. Doyon. To be updated soon with maps for the new detectors. Work conducted by G. Giardino. Map at 650 nm. The flat map is the relevant one for our analysis. The domes correspond to the amount of light collected by a given pixel as a function of the position of the source. Not collected is different from lost. Slide #34

Simulations Effect of intra-pixel sensitivity changes From the measured maps to a generic simulation. What is a representative intra-pixel sensitivity map? Exploring various solutions. Trying different super-pixel maps (median, average, worst ). Measurements at 1550 nm. Trying various locations in the measured map Tiling Slide #35

Simulations Effect of intra-pixel sensitivity changes Injecting the PSF shape in the simulations. 1D profiles (continuum spectrum). Simulations conducted both with simplified (Gaussian) profile and with representative profiles (PSF models). Slide #36

Simulations Effect of intra-pixel sensitivity changes Work in progress but overall the results indicates that in the case of NIRSpec, the intra-pixel sensitivity is likely to contribute at levels of a few 10-4 [prior to any calibration]. è Probably a major contribution for transit spectroscopy with NIRSpec. è Working on developing mitigation / calibration strategies. Work in progress. Results to be updated once the new maps are available. Mitigation / calibration strategies. Slide #37

Simulations Highlighting NIRSpec capabilities. Filling the template tables. Primary advertisement for the instrument capabilities. We need to agree on the inputs and the assumptions. è We need to discuss how we can achieve that in order to provide a consistent set of inputs for the white paper update. Slide #38

Simulations Highlighting NIRSpec capabilities. Example of NIRSpec capabilities. Slides extracted from J. Valenti s presentation at the NASA EXOPAG meeting. Figure 4b of Burrows, Budaj, & Hubeny (2008) Slide #39

Simulations Highlighting NIRSpec capabilities. Thermal emission from a hot Jupiter (secondary eclipse) Credit for the slide: J. Valenti (STScI). Detector gap Adapted from Figure 4b of Burrows, Budaj, & Hubeny (2008) Slide #40