UB 200 relay - Voltage monitoring

Similar documents
UB 001 relay - 1 level load shedding

UBC 200 relay - Voltage monitoring

UTC relay - Voltage monitoring & off delay

TELAU 400 relay - Delay-on pull-in or

407 relay - Latching, safety critical, 40 contacts Datasheet

TTBCR 200 relay - Delay-on drop-out,

BM 400 relay - Mixed load, 4 contacts

AG 400 relay - Gold plated, 4 contacts

TBSBAO 400 relay - Delay-on pull-in,

MSV200 - Hall effect transducer

MSA Hall effect transducer

RC-19A relay - Current monitoring

MSA500 - Hall effect transducer

V88 socket - Spring clamp terminal,

KCS-U200 relay - Latching, 2 pole

C relay - Safety critical, 9 contacts

CK relay - safety critical, 9 contacts

BD relay - Industrial latching power

CM relay - 7 contacts + 2 gold contacts

MTDV4-U200 relay - Voltage monitoring,

TDB4-U200 relay - Timer, delay-on, 4 pole

D4-U200 relay module - 4-pole

MTDV4 relay - Voltage monitoring,

Mors Smitt Industrial Technology. High performance plug-in relays

D-U200 Instantaneous relay Part of D-platform

D-B Power relay, high DC breaking capacity Part of D-platform

D Instantaneous relay Part of D-platform

Manual Signal calibration box (SCB)

Mors Smitt Industrial Technology. Industrial current & voltage sensors. Hall effect current & voltage sensors

Mors Smitt Industrial Technology

Portable relay tester PRT-MS1 User manual

Mors Smitt Industrial Technology

Mors Smitt Group - Serving Safety

Mors Smitt Railway Technology. Railway relays

Ordering Information. Latching Relay MMK. Available Models. Models Conforming to Auxiliary Power Relay Specifications

PRODUCT DESCRIPTION PAG ES. E110 Series 1PDT, 10 AMP RELAY 2-6. E310 Series 3PDT, 10 AMP RELAY E210 / E215 Series 2PDT, 10/15 AMP RELAY 13-19

OKT OKR Series APPLICATIONS. Shipbuilding

Contactors. Series C137, C163, C164, C165 Single pole contactors for battery voltages Catalogue B60.en

C20.en. Power contactors for AC and DC CT1115 and CT1130. Connect - Contact - Control

Polarized, latching hermetically sealed relay Contact arrangement. 3 PDT Coil supply

C20.en. Power contactors for AC and DC CT1115 and CT1130. Connect - Contact - Control

INSTRUCTION MANUAL (ATEX / IECEx)

Electrical Specifications

1 POLE - 1 to 2A (For Signal Switching)

OMRON MK-I / -S RELAY

Connect - Contact - Control. DC Contactors 600V / 750V / 1000V. F 215e

SERIES KC RELAY NONLATCH 3PDT, 25 AMP

Ratchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj

MI-10kV. Technical specifications Operating instructions. Supplier:

General-purpose Relay

DPDT MY2N-D2 MY2IN-D2 --- (DC only) 4PDT MY4N-D2 MY4IN-D PDT (bifurcated) MY4ZN-D2 MY4ZIN-D2 --- With built-in CR

All-or-nothing relay RH(M) 1000 in plug-in case and case for top-hat rail or wall mounting

AUXILIARY RELAYS FOR TRIPPING APPLICATIONS

DPDT+DPST-NO MM4KP-JD MM4XKP-JD

Ordering Information. Ratchet Relay G4Q. Model Number Legend

Model Number Structure

Relays & Sockets RU Series Universal Relays. With Latching or Momentary Lever. Standard (without lever) Key features:

Electrical Specifications

Electrical Specifications

2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5)

Proximity Sensor Terminology

Two-way Action Test Button (Models with Lockable Test Button) For Momentary Operation

PROXIMITY SENSOR TERMINOLOGY

RETROFITTING. Motor Protection Relay. Two mountings are available, Flush Rear Connection (EDPAR) or Projecting Rear Connection (SDPAR).

Nieaf-Smitt Maritime. Analogue panel indicators

Model UT20B: OPERATING MANUAL Table of Contents (1)

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

General-purpose Relay

HMI Components. Series. Flush design Raised design PCB (with adaptor) Indicator Pushbutton Illuminated pushbutton

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

Snap Action Switches Technical Guide

IGS IGS-M-EL-22(1) Contactors APPROVED. Iranian Gas Standards

G7K. Latching Relay. Compact Mechanical Lock Latching Relays with Manual Buttons. Model Number Structure. Ordering Information

Relays & Sockets. RF2V 2-Pole Force Guided Relays/SJ Series Relay Sockets. UL/Recogntion File No. E55996 TÜV SÜD. EU Low Voltage Directive

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder

3.4. Control Relays and Timers. Contents Description D5RR/D5RF Series... D7PR/D7PF Series. General Purpose Plug-In Relays

62 Series - Power relays 16 A. Features / /

Introducing. CII FCA-150 Series Relay 50 Amps, 1PST/NO (DM) CII FCAC-150 Series Relay 50 Amps, 1PST/NO (DM) with 1PDT Auxiliary Contacts

Smart Power Relay E I...

Phase-sequence Phase-loss Relay

YL SERIES RELAY LATCH DC COIL 4PDT, LOW LEVEL TO 5 AMP

AC / DC STROOMTANG MULTIMETER NI 30 AC / DC CLAMP MULTIMETER NI 30. Handleiding / Manual

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE

SINEAX TV809, 1 channel Programmable Isolating Amplifier

High-Speed DC Circuit-Breaker for Fixed Installation Type UR26, UR36 & UR40

PCB relay for DC voltage, polarized, monostable or bistable

3TX7, 3RS18 Coupling Relays

SYNCHRONISM RELAY SYNCRO-96. (Code ) INSTRUCTION MANUAL ( M / 99A ) (c) CIRCUTOR S.A.

Type Sealing Poles Contacts Rated voltage Model Standard Flux-tight 4 poles 3PST-NO, SPST-NC 24 VDC G7SA-3A1B. Type LED indicator Poles Rated voltage

62 Series - Power relays 16 A. Features SERIES / / Printed circuit mount 16 A Power relay

2 or 4 pole changeover contact Plug-in/Faston 187

62.22 Copper side view

HMI Components. Series. Raised design PCB (with adaptor) Machinery and Automation. Indicator Illuminated pushbutton

COMPACT HIGH POWER RELAY

HG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS

CX-Series. Circuit Breaker

Dual Reversing Module

Relays & Sockets RY/RM RY/RM Series Miniature Relays. Part Number Selection

60 Series - General purpose relays 6-10 A. Features Plug-in mount 10 A General purpose relay

Transcription:

- Voltage monitoring Datasheet Features Voltage monitoring relay 1 voltage level 2 C/O contacts, form Z Plug-in design with secure locking feature for maximum ease of maintenance -40 C...+85 C operating temperature Benefits Description The voltage monitoring relay UB 200 opens auxiliary loads circuits when battery voltage becomes too low and puts them back in service when battery voltage recovers. A time delay of several seconds (to be defined) engages before opening a load circuit and a time delay of several seconds (to be defined) before putting back in service a load. The plug-in design offers secure locking feature for maximum ease of maintenance (no wires need to be disconnected or other hardware removed for relay inspection or replacement). The resistance to impact and vibration is conform to standards in force for Railway Transported Equipment. Positive mechanical keying of relay to socket is built into relay and socket during manufacture and terminal identifications are clearly marked on identification plate that is permanently attached to the relay. The UB 200 relay is pluggable in the following sockets: EA 102 B, EA 102 BF, EA 103 BF, EA 104 B, EA 104 BF, EA 105 BF, EA 112 BF. Proven reliable Long life cycle Easy to maintain and replace Low life cycle cost No maintenance Railway compliancy NF F 62-002 Rolling stock - Instantaneous relays contacts and sockets NF F 16-101/102 Fire behaviour - Railway rolling stock EN 50155 Railway application - Electronic equipment used on rolling stock IEC 61373 Railway application - shock and vibration tests Application The UB 200 relay is designed for voltage level sensing and used for example to monitor the battery load shedding. 1

Technical specifications Functional and connection diagrams Timing diagram Example 110V DC battery Power On Battery Voltage drop Battery Voltage increase UP-83V UD-82V Tripping level Minimum time between the 2 levels t>10s Closed NC Contact Open τ 1 τ 2 τ 1 = 1 S τ 2 = 1 S Closed NO Contact τ 1 τ 2 Open Connection diagram Relay pin correspondence b1 b2 a1 c1 a2 c2 Relay pin correspondence 1 2 3 4 a R S K L a P T J M b O N H G b Level measurement +V d1 Power supply d4 V c d C B D A E F W V 1 2 3 4 (rear view of relay shown) X U Y Z Example: BW keying c d 2

Technical specifications Input data Keying Unom (VDC) Uoperating (VDC) Level 1 (drop/increase) AW 24 16 / 36 18 /20 BW 36 25 / 48 TBD (1) TBD (1) 48 33 / 60 TBD (1) DW 72 48 / 90 55 / 65 EW 110 75 / 138 TBD (1) (1) to be defined Electrical characteristics Operating voltage Operating current Output configuration Maximum load current Contact life Dielectric strength 24 VDC...110 VDC < 20 ma 2 C/O form Z 0.2 A 0.1 A resistive > 1.10 6 operations 0.1 A L/R = 30 ms > 1.10 6 operations 1500 VAC, 1 min between housing and tabs Time delay characteristics Time delay on voltage increase Time delay on volage drop 0...20 s (t1 to be defined 0...20 s (t2) to be defined Accuracy repeatability Voltage level tolerance + 1 V 3

Technical specifications Mechanical and environmental specifications Operating temperature -40 o C...+85 o C, IP50 (relay on socket) Vibrations 3 axis 2 g / 10...150 Hz Shocks 30 g / 11 ms Operating position Any attitude Environment NF F 20-600 Weight 150 g Material Polycarbonat (cover) / Polyester Melamine (base) Fire and smoke NF F 16-101/102 4

Technical specifications Dimensions (mm) Used with locking brackets Used with wire locking spring 5

Mounting possiblities / sockets EA 102 B EA 103 BF EA 104 B EA 112 BF Panel/flush mounting EA 102 B EA 102 BF EA 104 B EA 104 BF EA 112 BF Locking bracket (905843), rear connection, double Faston 5 mm Wire locking spring (926853), rear connection, single Faston 5 mm Locking bracket (905843), rear connection, single Faston 5 x 0.8 mm Wire locking spring (926853), rear connection, single Faston 5 x 0.8mm Wire locking spring (926853), rear connection, crimp contact Surface/wall mounting EA 103 BF* EA 105 BF* Wire locking spring (926853), front connection, M3 screw 6.5 mm ring terminals (2,5 mm 2 ) Wire locking spring (926853), front connection, single Faston 5 mm * Mounting possibility on 35 mm rail EN 50022 by adding suffix D to the part number (see socket datasheet) Note: Keying of relay to socket can be specified by adding the keying letters in the part number. See all details in the related socket datasheet. 6

Spare parts Spare parts - order part numbers (1) (1) (1) (1) LOCKING BRACKET 905846 (1) (1) SCREW FOR BRACKET METAL STRAP (2) METAL STRAP (4) C927210 P928060 (2) (3) P928061 WIRE LOCKING SPRING 431906654 ROUND PLASTIC PLUGS 414928005 HEX. PLASTIC KEYS 414905678 LOCK PINS ASSY 2 SCREWS 906364 212903020 (1) Parts only for socket (2) Parts for relay and socket (3) Parts only for relay 7

Instructions Installation Install socket and connect wiring correctly according identification to terminals. Plug relay into socket. Reverse installation into socket not possible due to mechanical blocking by snap-lock. Don t reverse polarity of coil connection. Relays can be mounted (tightly) next to each other and in any attitude. Warning! Never use silicon near by relays Operation Before operating always apply voltage to coil to check correct operation. Long term storage may corrode the silver on the relay pins. Just by plugging the relay into the socket, the female bifurcated receivers will automatically clean the corrosion on the pins and guarantee a good connection. Do not use the relay in places with flammable gas as the arc generated from switching could ignite gasses. Maintenance Correct operation of relay can easily be checked as transparent cover gives good visibility on the moving contacts. When the relay doesn t seem to operate correct, please check presence of coil voltage. Use a multimeter. If LED is used, coil presence should be indicated. If coil voltage is present, but the relay doesn t work, a short circuit of suppression diode is possible (The coil connection was reversed). If relay doesn t work after inspection, please replace relay unit by a similar model. Send defective relay back to manufacturer. Normal wear and tear excluded. 8

Ordering scheme Configuration: UB 200 36 BW F 1 1. Relay model 2. No. of 3. Nominal 4. Keying 5. Cover 6. Language contacts voltage type (test report) This example represents a UB 200 36 BW F 1. Description: UB 200 relay, Unom: 36 VDC, keying BW, relay cover for wire locking spring, test report in English 1. Relay model UB 2. Number of contacts 200 2 C/O contacts 3 & 4. Nominal voltage and keying 24 AW 24 VDC 36 BW 36 VDC 48 xx 48 VDC 72 DW 72 VDC 110 EW 110 VDC xx = to be defined 5. Relay cover type Relay cover with lock pins F Relay cover forwire locking spring 6. Language on test report French 1 English 2 Spanish 9

DS-UB 200-V2.0 May 2013 Mors Smitt France SAS Tour Rosny 2, Avenue du Général de Gaulle, F - 93118 Rosny-sous-Bois Cedex, FRANCE T +33 (0)1 4812 1440, F +33 (0)1 4855 9001 E sales@msrelais.com Mors Smitt Asia Ltd. # 807, Billion Trade Centre, 31 Hung To Road Kwun Tong, Kowloon, HONG KONG SAR T +852 2343 5555, F +852 2343 6555 E info@morssmitt.hk Mors Smitt B.V. Vrieslantlaan 6, 3526 AA Utrecht, NETHERLANDS T +31 (0)30 288 1311, F +31 (0)30 289 8816 E sales@nieaf-smitt.nl Mors Smitt Technologies Inc. 420 Sackett Point Road North Haven, CT 06473, USA T +1 (203) 287 8858, F +1 (888) 287 8852 E mstechnologies@msrelais.com Mors Smitt UK Ltd. Doulton Road, Cradley Heath West Midlands, B64 5QB, UK T +44 (0)1384 567 755, F +44 (0)1384 567 710 E info@morssmitt.co.uk (c) Copyright 2013 All rights reserved. Nothing from this edition may be multiplied, or made public in any form or manner, either electronically, mechanically, by photocopying, recording, or in any manner, without prior written consent from Mors Smitt. This also applies to accompanying drawings and diagrams. Due to a policy of continuous development Mors Smitt reserves the right to alter the equipment specification and description outlined in this datasheet without prior notice and no part of this publication shall be deemed to be part of any contract for the equipment unless specifically referred to as an inclusion within such contract.