Testing Numerical Transformer Differential Relays

Similar documents
PROTECTIVE RELAY MISOPERATIONS AND ANALYSIS

Catastrophic Relay Misoperations and Successful Relay Operation

Hands On Relay School Open Lecture Transformer Differential Protection Scott Cooper

Hands On Relay School Open Lecture Transformer Differential Protection Scott Cooper

The InterNational Electrical Testing Association Journal. BY STEVE TURNER, Beckwith Electric Company, Inc.

Verifying Transformer Differential Compensation Settings

Transformer Protection

DOUBLE-ENDED FAULT LOCATORS

Minnesota Power Systems Conference 2015 Improving System Protection Reliability and Security

Transformer Protection Principles

Pinhook 500kV Transformer Neutral CT Saturation

Power System Protection. Dr. Lionel R. Orama Exclusa, PE Week 3

Distance Relay Response to Transformer Energization: Problems and Solutions

Modern transformer relays include a comprehensive set of protective elements to protect transformers from faults and abnormal operating conditions

Overcurrent Elements

g GE POWER MANAGEMENT

Relay-assisted commissioning

STRAY FLUX AND ITS INFLUENCE ON PROTECTION RELAYS

PROTECTION OF TRANSFORMERS M-3311A TEST PLAN

ATP modeling of internal transformer faults for relay performance testing

Transformer Differential Protection Lab

Improving Transformer Protection

Bus Protection Fundamentals

CURRENT TRANSFORMER CONCEPTS

Differential Protection with REF 542plus Feeder Terminal

Visualization and Animation of Protective Relay Operation

How Transformer DC Winding Resistance Testing Can Cause Generator Relays to Operate

IMPROVEMENTS IN PROTECTION AND COMMISSIONING OF DIGITAL TRANSFORMER RELAYS AT MEDIUM VOLTAGE INDUSTRIAL FACILITIES

Analyzing the Impact of Shunt Reactor Switching Operations Based on DFR Monitoring System

Substation Testing and Commissioning: Power Transformer Through Fault Test

www. ElectricalPartManuals. com Transformer Differential Relay MD32T Transformer Differential Relay

Performance Analysis of Traditional and Improved Transformer Differential Protective Relays

Forward to the Basics: Selected Topics in Distribution Protection

Unit Protection Differential Relays

Line Protection Roy Moxley Siemens USA

Detecting and Managing Geomagnetically Induced Currents With Relays

COPYRIGHTED MATERIAL. Index

Shortcomings of the Low impedance Restricted Earth Fault function as applied to an Auto Transformer. Anura Perera, Paul Keller

DIFFERENTIAL PROTECTION METHODOLOGY FOR ARBITRARY THREE-PHASE POWER TRANSFORMERS

Impact of transient saturation of Current Transformer during cyclic operations Analysis and Diagnosis

Protection of a 138/34.5 kv transformer using SEL relay

889 Advanced Generator Protection Technical Note

Impact of Incipient Faults on Sensitive Protection

INSTRUCTIONS. GE Protection and Control. 205 Great Valley Parkway. Malvern, PA TRANSFORMER DIFFERENTIAL RELAY

TECHNICAL BULLETIN 004a Ferroresonance

Transformer Protection

TheRelayTestingHandbook

A Tutorial on the Application and Setting of Collector Feeder Overcurrent Relays at Wind Electric Plants

Considerations and Experiences in Implementing Ground Differential Protection for Transformer Protection at TVA

INSTRUCTIONS. GE Protection and Control. 205 Great Valley Parkway Malvern, PA GE K-45307K TRANSFORMER DIFFERENTIAL RELAYS WITH

This webinar brought to you by the Relion product family Advanced protection and control IEDs from ABB

EASUN REYROLLE LIMITED

Transformer Protection

Differential Protection Optimal differential protection for phase shifter transformers and special transformers

Using a Multiple Analog Input Distance Relay as a DFR

www. ElectricalPartManuals. com Generator Differential Relay MD32G Rotating Machine Differential Relay

Evaluating the Impact of Increasing System Fault Currents on Protection

Using Event Recordings

R10. IV B.Tech I Semester Regular/Supplementary Examinations, Nov/Dec SWITCH GEAR AND PROTECTION. (Electrical and Electronics Engineering)

O V E R V I E W O F T H E

POWER SYSTEM ANALYSIS TADP 641 SETTING EXAMPLE FOR OVERCURRENT RELAYS

EE Lecture 14 Wed Feb 8, 2017

The measurement of winding resistance is useful in detecting a number of types of fault in a transformer. Malfunctioning tap changer mechanisms

Transformer Fault Categories

ISSN: Page 298

Problems connected with Commissioning of Power Transformers

EARTH FAULT PROTECTION VIS-A-VIS GENERATOR GROUNDING SYSTEM

Tertiary Winding Design in wye-wye Connected Transformers Restricted Siemens Energy 2013 All rights reserved.

NERC Protection Coordination Webinar Series June 9, Phil Tatro Jon Gardell

Protective Relays Digitrip 3000

Earth Fault Protection

Back to the Basics Current Transformer (CT) Testing

Generator Protection Overcomes Current Transformer Limitations

Transformer protection IED RET 670

Transmission System Phase Backup Protection

EEL 3086 SWITCHGEAR AND PROTECTION EXPERIMENT 2 DIFFERENTIAL PROTECTION OF A THREE-PHASE TRANSFORMER

Beyond the Knee Point: A Practical Guide to CT Saturation

NERC Protection Coordination Webinar Series June 16, Phil Tatro Jon Gardell

Two variable ac current, variable phase-angle sources Variable dc voltage/current source and latch timer Variable harmonic current source

REDUCTION OF TRANSFORMER INRUSH CURRENT BY CONTROLLED SWITCHING METHOD. Trivandrum

This webinar brought to you by The Relion Product Family Next Generation Protection and Control IEDs from ABB

POWER SYSTEM PRINCIPLES APPLIED IN PROTECTION PRACTICE. Professor Akhtar Kalam Victoria University

function block description to the differential protection and restricted earth-fault protection functions for autotransformers

Turn-to-Turn Fault Detection in Transformers Using Negative Sequence Currents

Tutorial on Symmetrical Components

Bus protection with a differential relay. When there is no fault, the algebraic sum of circuit currents is zero

System Protection and Control Subcommittee

Figure 1 System One Line

GENERALS ELECTRIC INSTRUCTIONS POWER SYSTEMS MANAGEMENT DEPARTMENT PHILADELPHIA, PA. GEK Insert Booklet GEK RESTRAINT CIRCUITS

7SG14 Duobias-M Transformer Protection

ENOSERV 2014 Relay & Protection Training Conference Course Descriptions

Negative-Sequence Differential Protection Principles, Sensitivity, and Security

Data. Dr Murari Mohan Saha ABB AB. KTH/EH2740 Lecture 3. Data Acquisition Block. Logic. Measurement. S/H and A/D Converter. signal conditioner

GENERATOR INTERCONNECTION APPLICATION Category 5 For All Projects with Aggregate Generator Output of More Than 2 MW

Long lasting transients in power filter circuits

Current Transformer Requirements for VA TECH Reyrolle ACP Relays. PREPARED BY:- A Allen... APPROVED :- B Watson...

Utility Interconnection and System Protection

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers

Line protection with transformer in the protection zone

Generator Protection GENERATOR CONTROL AND PROTECTION

Transcription:

Feature Testing Numerical Transformer Differential Relays Steve Turner Beckwith Electric Co., nc. ntroduction Numerical transformer differential relays require careful consideration as to how to test properly. These relays provide different types of protection such as restrained phase differential, high set phase differential, restrained ground differential and overcurrent protection. All protection elements that are enabled should be adequately tested. A common commissioning practice is to test all the numerical relay settings to verify they were properly entered. Automated testing using computer software to run the test set has made this possible since the overall commissioning for a numerical relay could consist of several hundred tests. While this is a good check, it is still important to ensure that the transformer is thoroughly protected for the particular application. Transformer Differential Characteristic Boundary Test A common practice for commissioning distance protection is to test along the boundary of the operating characteristic; for example, circles, lenses, or quadraterals. This practice can also be applied to transformer differential protection. Consider the simple example of a two winding transformer with both sets of windings wye connected. To keep the example simple also assume both sets of CTs are wye connected and have the same CT ratios, that is both windings are at the same potential. f you connect the current leads from the test set such that the test currents and are flowing through the transformer winding then the per phase differential and restraint currents can be expressed as follows: d [] r + [] Where Winding per unit current (A, B, or C-phase) Winding per unit current (A, B, or C-phase) Express equations [] and [] using matrices as follows: d r 0.5 0.5 Where C M T [4] C d r, M, 0.5 0.5 T nvert the matrix M in equation [] to determine the two equations for the test currents: 0.5 d 0.5 r Calculate the test currents based upon an operating point on the differential characteristic as follows: d + r [7] d + r [8] st Example Consider a transformer differential characteristic for the two-winding transformer described earlier with the following settings: [] [5] [6] Winter 009-00 NETA WORLD

Pickup 0. per unit Slope 8.6% Where A, B, C, A, B and C are the CT currents. To test the A-phase differential element at point of the characteristic shown in Figure, use the following equations: A TAP [5] A TAP [6] Figure Phase Current Differential Characteristic for Two Winding Transformer Table lists the four operating points on the characteristic along with the corresponding test currents. All values are in per unit. d r 0. 0. 0.4 0. 0. 0.7 0.8 0.6 0.4.4.6. 0.6.0..7 From Table : 0.8 per unit [7] 0.6 per unit [8] A 0.8 TAP [9] A 0.6 TAP [0] Where A and A are the two test currents. Testing at Breakpoints for Dual Slope Characteristics Figure B below is the operating characteristic that corresponds to the following settings: Table Test Currents for Transformer Differential Characteristic Boundary Remember that the test currents are connected such that they are 80 degrees out of phase. Figure A 87T Dual Slope Relay Settings nd Example Now consider a transformer differential characteristic for a two-winding transformer connected delta (DAB) wye, with wye connected CTs on both sides. A numerical transformer differential relay internally compensates the CT currents as follows: Winding (DAB) Winding (Wye) Arelay A [09] A Arelay TAP TAP Brelay Crelay B [0] Brelay TAP C [] Crelay TAP B B C TAP C A TAP [] [] [4] Figure B Corresponding 87T Dual Slope Operating Characteristic (Per Unit) NETA WORLD Winter 009-00

There are two breakpoints. The first breakpoint occurs when the minimum pickup intersects with slope. The second breakpoint is the relay setting Slope Breakpoint (SBP). First Breakpoint Here is how to determine the first breakpoint where the operating characteristic switches from the minimum pickup to the first slope. The equation for a straight horizontal line (minimum pickup) is as follows: y a [Equation ] Where a is the minimum pickup setting The equation for the first slope is as follows: y m x [Equation ] Where m is the first slope setting To find the breakpoint set the two equations [] and [] equal then solve for x: a m x x a m So the first breakpoint is calculated as follows: (x a/m, y a) From Figure B: y 0.5 y 0. x [Equation, minimum pickup] [Equation, first slope] The second breakpoint for Figure B is as follows: (x 4.0, y 0.8) The equation of the line that corresponds to the second slope passing through the second breakpoint is determined as follows: y m x + b Where b is the y-intercept b y m x The y-intercept for the equation of the line that corresponds to the second slope passing through the second breakpoint is as follows: b 0.8 0.75 4.0 b -. The equation is as follows: y 0.75 x. Ground Differential Element Sensitivity Test Ground differential protection can provide good sensitivity for ground faults on wye-connected transformer windings. Figure shows a simple three-line diagram for a typical application. The CTs are connected such that: f G and 0 are in phase, the ground fault is external. f G and 0 have opposite polarity, the ground fault is internal. 0.5 0. x x 0.5/0..5 The first breakpoint is as follows: (x.5, y 0.5) Second Breakpoint Here is how to determine the second breakpoint where the operating characteristic switches from the first slope to the second slope. x SBP Figure Ground Differential Protection Connection Diagram y m SBP Where SBP Slope Breakpoint Winter 009-00 NETA WORLD

Stability is improved for CT saturation during external faults if the ground differential protection is disabled when G is less than a preset value, 00 milliamperes for example. The ground differential element operates when the difference between 0 and G is greater than the pickup setting: Fault Resistance 0 G > 50GD [] 0 and G add together in equation [] above when the ground fault is internal since they have opposite polarity for this condition. A good test is to check how much sensitivity 87GD provides for ground faults located close to the neutral of wye-connected windings coupled with fault resistance (R F ). Consider the case of a two-winding delta-wye 5 MVA distribution transformer connected to a 0 kv grid and serving load at kv. Here is the power system data: Source impedance (X S ) varies X T 0% R F varies Ground fault located 5% from neutral CTR kv 600:5 CTR GND 600:5 Figure 4 illustrates the sensitivity of 87GD as a function of the source impedance and ground fault resistance. The top curve corresponds to each point where G is equal to 00 milliamperes (that is, the minimum amount required for operation or the maximum sensitivity possible). The middle curve corresponds to each point where G is equal to 500 milliamperes. The bottom curve corresponds to each point where G is equal to ampere. The source impedance and ground fault resistance are in ohms primary. 80 60 40 0 00 80 60 40 0 87GD Sensitivity 0 0 0 40 60 80 00 0 Source mpedance Even Harmonic Restraint during Transformer nrush Events such as transformer energization can be captured by utilities using digital fault recorders or numerical relays and then later played back via COMTRADE to observe relay performance. Some customers have access to software such as the Alternative Transients Program (ATP) and can build their own transformer models to simulate inrush. This is a very practical method to check that the relay is properly set. One example of playback is to evaluate the performance of the restrained differential protection for transformer inrush with varying levels of harmonic content in the current waveforms. Transformer differential protection has historically used the nd harmonic content of the differential current to prevent unwanted operation during transformer inrush. t is advantageous to use both the nd and 4 th harmonic content of the differential current. The relay can internally calculate the total harmonic current per phase as follows: -4 + [] 4 The sum of the two even harmonics per phase helps to prevent the need to lower the value of restraint which could cause a delayed operation if an internal fault were to occur during transformer energization. Cross phase averaging also helps prevent unwanted operation during transformer inrush. Cross phase averaging averages the even harmonics of all three phases to provide overall restraint. The cross phase averaged harmonic restraint can be internally calculated by the relay as follows: r-4 [] A 4 + B 4 + C 4 The transformer relay with even harmonic restraint and cross phase averaging tested for the following cases did not misoperate. The inrush currents presented here were created using ATP and have a slow rate of decay. The autotransformer data is as follows: G 00 ma G 500 ma G Amp Figure 4 Ground Differential Sensitivity Diagram Figure 5 600 MVA Autotransformer Single Line Diagram (Delta Winding DAC) 4 NETA WORLD Winter 009-00

Auto-transformer Characteristics Z HM 0.007 per unit Z HL 0.04777 per unit Z ML 0.0 per unit ZH ZM ZL Z Z Z HM HM HL + Z HL + Z ML + Z ML Z Z Z CTR W 00:5 (wye connected) CTR W 000:5 (wye connected) 87T Relay Settings ML HL HM 0.040 per unit [4] -0.009 per unit [5] 0.040 per unit [6] Figure 6B nd Harmonic Component Currents for Balanced nrush TAP 600MVA 45kV 40 4.8 [7] TAP 600MVA 0kV 400.77 [8] 87T Pickup 0.5 per unit Slope 5% Slope 75% Breakpoint.0 per unit Even Harmonic Restraint 0% (cross phase averaging enabled) st Case Balanced nrush Energize Line with Bank from Single End (No residual flux) Figure 6C 4th Harmonic Component Currents for Balanced nrush Figure 6A Total Phase Currents for Balanced nrush Winter 009-00 NETA WORLD 5

nd Case Balanced nrush Energize Bank from Winding with Winding Open (No residual flux) rd Case Unbalanced nrush Energize Line with Bank from Single End (Severe A-phase residual flux) Figure 7A Total Phase Currents for Balanced nrush Figure 8A Total Phase Currents for Unbalanced nrush Figure 7B nd Harmonic Component Currents for Balanced nrush Figure 8B nd Harmonic Component Currents for Unbalanced nrush Figure 7C 4th Harmonic Component Currents for Balanced nrush Figure 8C 4th Harmonic Component Currents for Unbalanced nrush 6 NETA WORLD Winter 009-00

4 th Case Balanced nrush Energize Bank from Winding with Winding Open (Severe A-phase residual flux) Conclusions A common commissioning practice is to test all the numerical relay settings to verify they were properly entered. Automated testing using computer software to run the test set has made this possible since the overall commissioning for a numerical relay could consist of several hundred tests. While this is a good check it is still important to ensure that the transformer is thoroughly protected for the particular application. This paper presented three types of test for transformer differential protection: Transformer Differential Characteristic Boundary Test Ground Differential Sensitivity Test Even Harmonic Restraint during Transformer nrush Figure 9A Total Phase Currents for Unbalanced nrush The first test determines if the transformer differential protection meets the stated accuracy for the operating characteristic slopes. The second test determines the fault resistance coverage of the ground differential protection as a function of the source impedance. The third test determines if the transformer differential protection harmonic restraint works during a variety of stringent conditions that could occur during actual energization. Figure 9B nd Harmonic Component Currents for Unbalanced nrush Steve Turner is a Senior Applications Engineer at Beckwith Electric Company, nc. His previous experience includes working as an application engineer with GEC Alstom for five years, primarily focusing on transmission line protection in the United States. He also was an application engineer in the international market for SEL, nc. again focusing on transmission line protection applications. Steve wrote the protectionrelated sections of the instruction manual for SEL line protection relays as well as application guides on various topics such as transformer differential protection and out-of-step blocking during power swings. Steve also worked for Progress Energy in North Carolina, where he developed a patent for double-ended fault location on transmission lines and was in charge of all maintenance standards in the transmission department for protective relaying. Steve has both a BSEE and MSEE from Virginia Tech University. He has presented at numerous conferences including: Georgia Tech Protective Relay Conference, Western Protective Relay Conference, ECNE and Doble User Groups, as well as various international conferences. Steve is also a senior member of the EEE. Figure 9C 4th Harmonic Component Currents for Unbalanced nrush Winter 009-00 NETA WORLD 7