Contents H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A. Solid-state Timer. Common to ALL Timers

Solid-state Timer H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

Solid-state Twin Timer

Multi Function Timer with Free power, Compact size W38 H42mm

No mark Time-limit SPDT (1c) A Time-limit DPDT (2c) B Time-limit SPDT (1c), Instantaneous SPDT (1c) S DIN W48 H48mm.

Solid-state Timer H3DE

Timers GE1A. GE1A Series ON Delay Timers Single Function

Solid-state Timer H3DS

Ratchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load

SPST-NO SPDT DPST-NO DPDT

SPST-NO SPDT DPST-NO DPDT

Timers GT3F. GT3F Series True Power OFF Delay Timers. Phone: Fax: Web: -

Ordering Information. PCB Relay G6RL. Model Number Legend: Low-profile power relay with maximum switching of 10 A

PCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

Solid-State Timer. ON-delay, Repeat cycle/signal OFF start, Repeat cycle/signal ON start, Signal ON/OFF-delay, Signal OFF-delay, and Interval

Classification Enclosure rating Contact form Contact material

И М. 2 24VAC 50/60Hz, 24-48VDC VAC 50/60Hz

ON-delay operation 8-pin round socket DPDT --- H3CA-8 H3CA-8 SPDT SPDT H3CA-8H H3CA-8H

Classification Enclosure rating Contact form Model Standard Flux protection SPST-NO G6RL-1A

OMRON. H3DE - Standard Timer. H3DE-G - Star-Delta Timer. H3DE-F - Twin Timer. H3DE-H - Power OFF- Delay Timer

Select G3PA SSRs and G32A Cartridges to be Discontinued; Replace with G3PA-X or G3PJ Relays, G32A-A-X Cartridges

3. Contact Form A: SPST-NO

Timers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range

Ordering Information. Latching Relay MMK. Available Models. Models Conforming to Auxiliary Power Relay Specifications

Two-way Action Test Button (Models with Lockable Test Button) For Momentary Operation

Solid-State Digital Counter H7AN

Solid-state Timer. Operation/resetting system Time-limit contact Time ranges Model

No mark VAC 50/60Hz, VDC 1 12VDC 2 24VAC 50/60Hz, 24VDC. selectable by output operation mode

Power PCB Relay. To Order: Select the part number and add the desired coil voltage rating (e.g., G6B-1114-US-DC6).

Coaxial Switch. Ordering Information. High-frequency, High-capacity Coaxial Switch Supporting Bandwidth to 26.5 GHz. Model Number Legend:

Timers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range 13.

Solid-state Timer H3DS

Solid-state Timer H3DS

COMPACT SIZE HIGH PRECISION TIMERS VARIOUS OUTPUT & OPERATION MODE TYPES. UL File No.: E CSA File No.: LR39291

G2RL-1A G2RL-1 G2RL-2A G2RL-2

Tactile Switch. Ordering Information. A Wide Range of Models: 6 6 mm, mm, Side-operated, High-force, and Gold-plated.

Classification Terminal Shape Contact form Enclosure rating Model Rated coil voltage

Technical Information General Purpose Relays

Enclosure rating. LED indicator with test button G2R-1-SNI G2R-2-SNI Unsealed Diode. LED indicator and diode with test button G2R-1-SNDI G2R-2-SNDI

Solid-state Timer H3DE

Classification Contact form Enclosure rating Terminal shapes Model Minimum packing unit Standard. SPST-NO (1a) Fully sealed PCB terminal

OFF-delay time. 7.5 s. 15 s. 30 s. Main contacts Auxiliary contact Number of input channels Rated voltage Model Category

Ordering Information. Ratchet Relay G4Q. Model Number Legend

Classification Contact form Contact type Contact material Enclosure Rating Model Standard DPDT Bifurcated crossbar Ag (Au alloy) Fully sealed G5V-2

No mark Time-limit contact 1c Time-limit contact 2c,Time-limit contact A 1c+Instantaneous contact 1c(selectable) DIN W48 H48mm (4digit)

4. Classification E: High capacity. 3. Terminal Form Blank: Tab terminals (#250 terminals) Tab terminals #250 SPST-NO

Ordering Information. Ratchet Relay G4Q. Plug-in Models. Model Number Legend

SPECIFICATIONS. For Reference. This specification sheet is for reference only, Please request it again if a specification for receipt is necessary.

Details on the New G2RS

PCB Footprint Max.Load Coil Voltage Non-Latching part number Single-coil latching part number Standard ground terminal (1GHz)

Model Number Structure

Contact Ag + Au-clad AgPd + Au-clad. General purpose DPDT G6AU-274P-ST-US G6AU-234P-ST-US 4PDT G6AU-474P-ST-US G6AU-434P-ST-US

CP RELAYS POWER TYPE. TYPICAL APPLICATIONS Defoggers, Ignitions, Heaters, Accessories, Powered windows, etc. ORDERING INFORMATION TYPES

G6C. Miniature High Capacity Relays with SPST-NO 10A and SPST-NO + SPST-NC 8A. Model Number Legend. Application Examples.

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

Contents H3DS. DIN Track Mounted, Standard 17.5-mm Width Timer Range. Broad Line-up of H3DS Series. Solid-state Timer. Common to ALL Timers H3DS-X

02/11/2015

G5NB. A Miniature Relay with 1-pole 3A/5A Switching Capability and 10 kv Impulse Withstand Voltage. Application Examples. Model Number Legend

Ultraminiature Photoelectric Switches with Self-contained Amplifier

Remote Sensor Amplifier Terminal

Model Number Structure

05/09/2012

DIN48 SIZE MULTI-RANGE ANALOG TIMER. Protective construction. Time range IP65 IP50 IP selectable ranges 1s to 500h IP50 IP65 IP50

Digital Panel Meter. Ordering Information. Subminiature Digital Panel Meter that Accepts DC Input. Accessories (Order Separately)

PCB Relay. Contact form Terminal Single-side stable Single-winding latching Double-winding latching

DIN48 SIZE ANALOG MULTI-RANGE CYCLIC TWIN TIMERS

G70R-SOC08 CSM_G70R-SOC08_DS_E_2_1

Model Number Structure

Model Number Structure

G5Q. Ordering Information. Specifications. PCB Relay. Compact, High Isolation Relay J COIL RATINGS. 638 PCB Relay G5Q

OMRON MK-I / -S RELAY

General-purpose Relay

A W - A 2A R - 24D - 1


Phase-sequence Phase-loss Relay

Safety Relay Unit. OFF-delay time

Monitoring voltages of 3-phase 4 wires with a single unit

PART NUMBERING SYSTEM

Bulletin 700-HX Multifunction Digital Timing Relay

DPDT+DPST-NO MM4KP-JD MM4XKP-JD

G5LE. Ordering Information. PCB Relay. A Cubic, Single-pole 10-A Power Relay J MODEL NUMBER LEGEND G5LE PCB Relay G5LE

Type Sealing Poles Contacts Rated voltage Model Standard Flux-tight 4 poles 3PST-NO, SPST-NC 24 VDC G7SA-3A1B. Type LED indicator Poles Rated voltage

Subminiature Automotive Relays Type CV20 Monostable

Micro-ISO Automotive Relay. (Unit: mm inch)

High switching capacity 1a/1c 30A power relays

General-purpose Relay

Suitable for lighting and motor load, 1 Form A 50A latching relays

HPJSeries HPJ. Ultraminiature Photoelectric Sensors with Self-contained Amplifier

38 Series - Relay interface modules A

PART NUMBERING SYSTEM

MINIATURE POWER RELAY IN DS RELAY SERIES FEATURES resistance ORDERING INFORMATION. Ex. DSP 1 L DC12V R

27/04/2015

40 Series - Miniature P.C.B. Relays A

20 AMP POWER RELAY HG RELAYS. a HG HG HG Unit weight. Ex. HG 2 AC 240 V

G7K. Latching Relay. Compact Mechanical Lock Latching Relays with Manual Buttons. Model Number Structure. Ordering Information

ULTRA LOW PROFILE 2 A POLARIZED RELAY. mm inch. Initial breakdown voltage

Panasonic products. SIngle function-multirange Multifunction single-range Multifunction-multirange. Precise High quality.

Transcription:

Analog r TTL Series Part Number Description TTL - ❶ ❷ ❸ ❶ Pin Type 8 : 8Pin Socket and Panel mounted ❷ Timing Mode A : A, A1, F1, I B : A, A1, B, F ❸ Supply Voltage 110/220VAC 24VDC 110VDC General Specification Model Name Function Timing Range Rated Supply Voltage TTL-8A, TTL-8B Multi r 0.05sec ~ 100hour (Max. hours) 100-240VAC 50/60Hz, 24VDC, 110VDC Operating Voltage Range Power Consumption Recovery Control Output Life Cycle Contact Form Contact Capacity 90 ~ 110% of the Supply Voltage Approx. 4.5VA (220VAC 60Hz) Approx. 1.5W (24VDC) Approx. 2.2W (110VDC) Max. 200ms Mechanical Min. 10,000,000 Electrical Min. 100,000 Output by the Output Operation Mode, Temp (2C) Select Among Order (1C) + Temp (1C) NO : 250VAC 3A Resistance Load NC : 250VAC 2A Resistance Load Accuracy of operating time Max. ±0.3% FS Setting Error ±5% Influence of Voltage Influence of Temperature Insulation Resistance Dielectric Resistance Noise Immunity Max. ±0.5% FS Max. ±2% FS 100MΩ (for 500VDC) For 1 Minute Under 2000VAC 50/60Hz The Wave Form Noise (pulse 1us) ±2kV by the Noise Simulator Vibration Resistance Shock Resistance Malfunctional Destruction Malfunctional Destruction 10-55Hz(1 Minute Duration) Dual Wave Length 0.5mm 10 Minutes for Each Direction of X, Y, Z 10-55Hz(1 Minute Duration) Dual Wave Length 0.75mm 1 Hour for Each Direction of X, Y, Z 100m/s 2 (10G) Three s for Each Direction of X, Y, Z 300m/s 2 (30G) Three s for Each Direction of X, Y, Z Ambient Temperature Storage Temperature Ambient Humidity Weight -10 ~ +55 C (with no icing) -25 ~ +65 C (with no icing) 35 ~ 85%RH Approx. 100g (Except For The Packaging Material) Ⅲ - 46 Industrial Controls Catalog www.kacon.co.kr

Data Processing Product Selection Timing Mode Part Number Voltage A, A1, F1, I TTL-8A TTL-8A 110/220VAC TTL-8A 24VDC TTL-8A 110VDC A, A1, B, F TTL-8B TTL-8B 110/220VAC TTL-8B 24VDC TTL-8B 110VDC Range Range Unit Setting Range 0.5 0.05 ~ 0.5 1.0 0.1 ~ 1.0 sec 5 0.5 ~ 5 10 1 ~ 10 0.5 0.05 ~ 0.5 1.0 0.1 ~ 1.0 min 5 0.5 ~ 5 10 1 ~ 10 Range Unit Setting Range 0.5 0.05 ~ 0.5 1.0 0.1 ~ 1.0 hour 5 0.5 ~ 5 10 1 ~ 10 0.5 0.05 ~ 0.5 1.0 0.1 ~ 1.0 10h 5 0.5 ~ 5 10 1 ~ 10 Data Processing Diagram TTL-8A, TTL-8B [A], [F] output operation mode contact: [A1], [B], [F1], [I] output operation mode contact: Resistive Load Resistive Load source source www.kacon.co.kr Industrial Controls Catalog Ⅲ - 47

Analog r TTL Series r Function Power Indicator / Output Indicator (On-Delay NO Contact Operation : Green On-Delay NO Contact Open : Orange) Setting Knob (Set ) Operation Mode Selector Operation Mode Display Window TTL-8A (A, A1, F1 and I mode) TTL-8B (A, A1, B and F mode) Range Selector Unit Display Window (sec, min, hour, 10h) Unit Selector Rotate the time unit shift switch and operation mode shift switch clockwise. range shift switch cannot be rotated below 0.5 and above 10. Do not forcefully rotate the switch. Dimension (mm) Panel Socket : K2BF08 Output Operation Mode For Each Model TTL-8A TTL-8B Indication Operation Mode Indication Operation Mode A Power on Delay A Power on Delay A1 Power on Delay 1 A1 Power on Delay 1 F1 Flicker (ON) B Power on Delay 2 I Interval F Flicker (OFF) Ⅲ - 48 Industrial Controls Catalog www.kacon.co.kr

Data Processing Timing Charts (TTL-8A, TTL-8B) : Indication Lamp (Green), :Indication Lamp (Yellow), t : Configured time, t>t-a Rt: Returning time (100ms lower) Mode Table A power on delay power source 2-7 time delay NC 1-4 (8-5) time delay NO 1-3 (8-6) power/output Indication LED A1 power on delay 1 (One-shot output) B power on delay 2 power source 2-7 time delay NC 8-5 time delay NO 8-6 instantaneous NC 1-4 instantaneous NO 1-3 power/output Indication LED power source 2-7 time delay NC 8-5 time delay NO 8-6 0.5sec 0.5sec Data Processing instantaneous NC 1-4 instantaneous NO 1-3 power/output Indication LED F flicker (OFF start) power source 2-7 time delay NC 1-4 (8-5) time delay NO 1-3 (8-6) power/output Indication LED F1 flicker 1 (ON start) power source 2-7 time delay NC 8-5 time delay NO 8-6 instantaneous NC 1-4 instantaneous NO 1-3 power/output Indication LED I interval power source 2-7 time delay NC 8-5 time delay NO 8-6 instantaneous NC 1-4 instantaneous NO 1-3 power/output Indication LED In the F or F1 output operation mode, an extremely short time setting may lead to abnormal output operation due to the contact output response time. The minimum time setting must be 100 ms. www.kacon.co.kr Industrial Controls Catalog Ⅲ - 49

Analog r TTL Series Part Number Description TTL - ❶ ❷ ❶ Function ❷ Supply Voltage SD: Star-Delta operation 100/240 VAC General Specification Model Name Function Timing Range Rated Supply Voltage Operation Voltage Range Power Consumption Recovery Control Output life cycle TTL-SD Star - Delta TIMER 0.05sec ~ 100sec (Maximum hours) 100/240VAC 50/60Hz 90 ~ 110% of the Supply Voltage approx. 4VA(240VAC 60Hz) Max. 100ms Contact Form contact : SPST (1N/O), contact : SPST (1N/O) Contact Capacity 250VAC 3A Resistance Load Mechanical Min. 10,000,000 Electrical Repetition Tolerance Max. ±0.3% Setting Error ±5% Influence of Voltage Max. ±0.5% Influence of Temperature Max. ±2% Shift Tolerance ±25% Insulation Resistance Dielectric Resistance Noise Immunity Vibration Resistance Shock Resistance Malfunctional Destruction Malfunctional Destruction Ambient Temperature Storage Temperature Ambient Humidity Weight Y Max. 100,000 (250VAC 3A Resistance Load) 100MΩ (for 500VDC) 2000VAC 50/60Hz for 1 minute the wave form noise (pulse 1us) ±2kV by the noise simulator 10-55Hz(1 Minute Duration) Dual Wave Length 0.5mm 10 Minutes for Each Direction of X, Y, Z 10-55Hz(1 Minute Duration) Dual Wave Length 0.75mm 1 Hour for Each Direction of X, Y, Z 100m/s 2 (10G) Three s for Each Direction of X, Y, Z 300m/s 2 (30G) Three s for Each Direction of X, Y, Z -10 ~ +55 C (with no icing) -25 ~ +65 C (with no icing) 35 ~ 85%RH Approx. 100g (except for the packaging material) Product Selection Dimension (mm) Operating Mechanism Part Number [Panel processing dimension diagram] Analog r TTL-SD Panel socket : K2BF08 Ⅲ - 50 Industrial Controls Catalog www.kacon.co.kr

Data Processing Diagram r Function Contact: 250VAC 3A Resistive Load Star Operation Indication Delta Operation Indicator Setting Knob source source Scale Range Display Window (T1) Star Operation Range Selector Switch Knob A: 50ms B: 100ms C: 250ms D: 500ms Star-Delta Transfer Selector (T2) Range 1. T1( Setting) Specification Range Unit Setting Range 0.5 0.5 ~ 5 sec 1.0 1 ~ 10 sec x10sec 5 5 ~ 50 sec 10 10 ~ 100 sec 2. T2(Shifting ) Specification (msec) Switch Display A B C D T2 Shifting 50 100 250 500 Data Processing Timing Charts The Y contact is switched on as soon as the power application, and is switched off at T1 (time setting). After T2 (shift time), the contact is switched on. If the power is switched off with the contact on, the contact is switched off. Y Y Power (2-7) Indicator Current Indicator 1. The power supply voltage must be applied at once using the contacts including switches and relays. Slow power application may cause timer operation errors. 2. Prolonged continuous conduction shortens the timer life due to the heating of electronic parts in the timer. 3. Pay attention to the polarity when the DC power is supplied to the timer. 4. Cutting off the power as in figure 1 generates bypass leakage current path through the resistor and condenser and leads to the timer operation errors. Connect the resistor and condenser as in figure 2 to prevent the time operation error. 5. Changing the time setting (T1), time range or shift time (T2) during the timer operation may cause an operation error. Be sure to cut off the power before changing the settings. 6. Do not use the device in the places where: the rated temperature or humidity are exceeded; the condensation occurs due to the temperature change; the flammable or corrosive gas is generated; dusts and oil are plentiful or vibration and shock are severe; strong alkali or acid substances are used; direct sunlight exists; and there are devices that generate strong magnetic force or electric noise nearby. www.kacon.co.kr Industrial Controls Catalog Ⅲ - 51

Analog r TTL Series Part Number Description TTL - ❶ ❷ ❸ ❶ Pin Type ❷ Function ❸ Unit 8 : 8Pins Socket and Mounted F : Power Off Delay S : Second (10s) General Specification Model Name Funtion Timing Range Rated Supply Voltage Power Consumption Control Output life cycle Contact Form Contact Capacity TTL-8FS Power OFF Delay 10sec 85V-265VAC 50/60Hz 0.5VA(120VAC 60Hz), 0.9VA(240VAC 60Hz) 0.5W(110VDC), 0.2W(48VDC), 0.1W(24VDC) 2N/O + 2N/C 250VAC 3A Resistance Load Mechanical Min. 10,000,000 Electrical Accuracy of Operating Max. ±0.3% Setting Error ±5% Influence of Voltage Influence of Temperature Insulation Resistance Dielectric Resistance Noise Immunity Vibration Resistance Shock Resistance Malfunctional Destruction Malfunctional Destruction Ambient Temperature Storage Temperature Ambient Humidity Weight Max. 100,000 (250VAC 3A Resistance Load) Max. ±0.5% FS Max. ±2% FS 100MΩ (for 500VDC) 2000VAC 50/60Hz for 1 minute the wave form noise (pulse 1us) 2kV by the noise simulator 10-55Hz(1 Minute Duration) Dual Wave Length 0.5mm 10 Minutes for Each Direction of X, Y, Z 10-55Hz(1 Minute Duration) Dual Wave Length 0.75mm 1 Hour for Each Direction of X, Y, Z 100m/s 2 (10G) Three s for Each Direction of X, Y, Z 300m/s 2 (30G) Three s for Each Direction of X, Y, Z -10 ~ +55 C (with no icing) -25 ~ +65 C (with no icing) 35 ~ 85%RH Approx. 100g (except for the packaging material) Product Selection Operating Mechanism Part Number - 8pins plug type - Power off delay sec TTL-8FS Ⅲ - 52 Industrial Controls Catalog www.kacon.co.kr

Data Processing Diagram r Function Contact: Resistive Load Power Indicator Output Indicator Scale Range Display Window Setting Knob Range Selector Out Display Window Dimension (mm) Timing Charts [Panel processing dimension diagram] Data Processing Panel Socket : K2BF08 The a contact is switched on as soon as the power is supplied. After the set time (T) from the power off, the a contact is switched off. Caution Power supply The timer does not operate with the power supplied, but operate after the power is switched off. Noise 1) For the test of impulse voltage between the power terminals, a voltage of 2kV with a pulse width of 1μs is applied. For the test of external noise voltage, a voltage of 1kV with a pulse width of 1μs is applied using a noise simulator. For the impulse noise voltage above these values, connect an AC MP condenser or oil condenser (0.1 ~ 1μF) between the power supply terminals. 2) When testing the withstand voltage, impulse voltage and insulation resistance with the device assembled with the control panel, Separate this product from the circuit completely. Short all terminals (to prevent damage to the internal circuit when some units on the control panel have poor withstand voltage and insulation.) Environment Do not use the device in the places where: the rated temperature or humidity are exceeded; the condensation occurs due to the temperature change; the flammable or corrosive gas is generated; dusts and oil are plentiful or vibration and shock are severe; strong alkali or acid substances are used; direct sunlight exists; and there are devices that generate strong magnetic force or electric noise nearby. www.kacon.co.kr Industrial Controls Catalog Ⅲ - 53

Analog r TTL Series Part Number Description TTL-T - ❶ ❷ ❸ ❶ Contact 1 : temp. DPDT (2N/O + 2N/C) 2 : temp. SPDT (2N/O + 2N/C), order SPST (2N/O + 2N/C) ❷ Unit S : Seconds (1, 3, 6, 10, 30, 60) M : Minutes (3, 6, 10, 30, 60) H :Hours (3, 6, 12, 24) ❸ Supply Voltage 110VAC 220VAC 24VDC General Specification Model TTL- T1 TTL- T2 Function Power ON delay Timing Range sec(1, 3, 6, 10, 30, 60), min(3, 6, 10, 30, 60), hour(3, 6, 12, 24) Rated Supply Voltage 110VAC, 220VAC 50/60Hz, 24VDC Operating Voltage Range 90 ~ 110% of the Supply Voltage Power Consumption Approx. 10VA(240VAC 60Hz), Approx. 2W(24VDC, 12VDC) DC(Option) Recovery Max. 200ms Control Output life cycle Contact Form Power ON delay(2n/o + 2N/C) Power ON delay(1n/o + 1N/C) / Instantaneous(1N/O + 1N/C) Contact Capacity 250VAC 3A resistance load Mechanical Min. 10,000,000 Electrical Max. 100,000 (250VAC 3A resistance load) Accuracy of operating time Max. ±0.3% Setting Error ±5% Influence of Voltage Max. ±0.5% FS Influence of Temperature Max. ±2% FS Insulation Resistance 100MΩ (for 500VDC) Dielectric Resistance 2000VAC 50/60Hz for 1 minute Noise Immunity The wave form noise (pulse 1us) ±2kV by the noise simulator Vibration Malfunctional 10-55Hz (1 minute duration) Dual Wave Length 0.5mm 10 minutes for Each Direction of X, Y, Z Resistance Destruction 10-55Hz (1 minute duration) Dual Wave Length 0.75mm 1 h our for Each Direction of X, Y, Z Shock Malfunctional 100m/s2 (10G) Three s for Each Direction of X, Y, Z Resistance Destruction 300m/s2 (30G) Three s for Each Direction of X, Y, Z Ambient Temperature -10 ~ +55 C (with no icing) Storage Temperature -25 ~ +65 C (with no icing) Ambient Humidity 35 ~ 80%RH Weight Approx. 75g (except for the packaging material) Product Selection Contact form Unit Range Part Number 220VAC 110VAC 24VDC Contact Form Unit Range Part Number 220VAC 110VAC 24VDC Power ON delay DPDT (2N/O + 2N/ C) sec 1 TTL-T1-1S 220VAC TTL-T1-1S 110VAC TTL-T1-1S 24VDC 3 TTL-T1-3S 220VAC TTL-T1-3S 110VAC TTL-T1-3S 24VDC 6 TTL-T1-6S 220VAC TTL-T1-6S 110VAC TTL-T1-6S 24VDC 10 TTL-T1-10S 220VAC TTL-T1-10S 110VAC TTL-T1-10S 24VDC 30 TTL-T1-30S 220VAC TTL-T1-30S 110VAC TTL-T1-30S 24VDC Power ON delay SPDT (1N/O + 1N/C), Instantaneous SPST (1N/O + 1N/C) sec 1 TTL-T2-1S 220VAC TTL-T2-1S 110VAC TTL-T2-1S 24VDC 3 TTL-T2-3S 220VAC TTL-T2-3S 110VAC TTL-T2-3S 24VDC 6 TTL-T2-6S 220VAC TTL-T2-6S 110VAC TTL-T2-6S 24VDC 10 TTL-T2-10S 220VAC TTL-T2-10S 110VAC TTL-T2-10S 24VDC 30 TTL-T2-30S 220VAC TTL-T2-30S 110VAC TTL-T2-30S 24VDC 60 TTL-T1-60S 220VAC TTL-T1-60S 110VAC TTL-T1-60S 24VDC 60 TTL-T2-60S 220VAC TTL-T2-60S 110VAC TTL-T2-60S 24VDC 3 TTL-T1-3M 220VAC TTL-T1-3M 110VAC TTL-T1-3M 24VDC 3 TTL-T2-3M 220VAC TTL-T2-3M 110VAC TTL-T2-3M 24VDC 6 TTL-T1-6M 220VAC TTL-T1-6M 110VAC TTL-T1-6M 24VDC 6 TTL-T2-6M 220VAC TTL-T2-6M 110VAC TTL-T2-6M 24VDC min 10 TTL-T1-10M 220VAC TTL-T1-10M 110VAC TTL-T1-10M 24VDC min 10 TTL-T2-10M 220VAC TTL-T2-10M 110VAC TTL-T2-10M 24VDC 30 TTL-T1-30M 220VAC TTL-T1-30M 110VAC TTL-T1-30M 24VDC 30 TTL-T2-30M 220VAC TTL-T2-30M 110VAC TTL-T2-30M 24VDC 60 TTL-T1-60M 220VAC TTL-T1-60M 110VAC TTL-T1-60M 24VDC 60 TTL-T2-60M 220VAC TTL-T2-60M 110VAC TTL-T2-60M 24VDC 3 TTL-T1-3H 220VAC TTL-T1-3H 110VAC TTL-T1-3H 24VDC 3 TTL-T2-3H 220VAC TTL-T2-3H 110VAC TTL-T2-3H 24VDC hour 6 TTL-T1-6H 220VAC TTL-T1-6H 110VAC TTL-T1-6H 24VDC 12 TTL-T1-12H 220VAC TTL-T1-12H 110VAC TTL-T1-12H 24VDC hour 6 TTL-T2-6H 220VAC TTL-T2-6H 110VAC TTL-T2-6H 24VDC 12 TTL-T2-12H 220VAC TTL-T2-12H 110VAC TTL-T2-12H 24VDC 24 TTL-T1-24H 220VAC TTL-T1-24H 110VAC TTL-T1-24H 24VDC Ⅲ - 54 Industrial Controls Catalog www.kacon.co.kr 24 TTL-T2-24H 220VAC TTL-T2-24H 110VAC TTL-T2-24H 24VDC

Data Processing Dimension [Panel processing dimension diagram] Panel socket : K2BF08 Diagram TTL-T1 (ON delay. 1C) (ON delay. 1C) Contact : NO : 250VAC 3A Resistive Load TTL-T2 (Instantaneous. 1C) (ON delay. 1C) Contact : NO : 250VAC 3A Resistive Load Data Processing Source Source r Function Range Power on Indicator Output Indicator Set Timing Range Set Timing Range Set Timing Range 1 sec 0 ~ 1 sec 3 min 0 ~ 3 min 3 hour 0 ~ 3 hour Scale Range Display Window 3 sec 0 ~ 3 sec 6 sec 0 ~ 6 sec 6 min 0 ~ 6 min 10 min 0 ~ 10 min 6 hour 0 ~ 6 hour 12 hour 0 ~ 12 hour Display unit 10 sec 0 ~ 10 sec 30 min 0 ~ 30 min 24 hour 0 ~ 24 hour 30 sec 0 ~ 30 sec 60 min 0 ~ 60 min 60 sec 0 ~ 60 sec Timing Charts Mode Table Mode Table T1 Power 2-7 ON delay NC 1-4 (8-5) ON delay NO 1-3 (8-6) Up LED T2 Power 2-7 Instantaneous NC 1-4 Instantaneous NO 1-3 ON delay NC 8-5 ON delay NO 8-6 Up LED t : Set Rt : Reset time (Minimum 50ms) www.kacon.co.kr Industrial Controls Catalog Ⅲ - 55

Analog r TTL Series Caution Environment Do not use the device in the places where: the rated temperature or humidity are exceeded; the condensation occurs due to the temperature change; the flammable or corrosive gas is generated; dusts and oil are plentiful or vibration and shock are severe; strong alkali or acid substances are used; direct sunlight exists; and there are devices that generate strong magnetic force or electric noise nearby. Noise 1) For the test of impulse voltage between the power terminals, a voltage of 2kV with a pulse width of 1 μs is applied. For the test of external noise voltage, a voltage of 1kV with a pulse width of 1 μs is applied using a noise simulator. For the impulse noise voltage above these values, connect an AC mp condenser or oil condenser (0.1 ~ 1 μf) between the power supply terminals. 2) When testing the withstand voltage, impulse voltage and insulation resistance with the device assembled with the control panel, Separate this product from the circuit completely. Short all terminals (to prevent damage to the internal circuit when some units on the control panel have poor withstand voltage and insulation.) Accessories (TTL, TTS, TTL Series) TTL-PR (ivory color) TTL-PK (black) TTL-BK TTS-BK Socket <K2BF08(8pin), K2BF11(11pin)> K2BF-F1 (Socket fixture hook) Ⅲ - 56 Industrial Controls Catalog www.kacon.co.kr

Analog r TTM Series Part Number Description TTM - 4 ❶ ❷ ❸ ❶ Range 0.5 : 0.5 001 : 1 180 : 180(Seconds Only) 005 : 5 010 : 10 030 : 30 060 : 60 ❷ Unit S : Seconds M : Minute ❸ Supply Voltage 110VAC 220VAC 12VDC 24VDC 110VDC General Specification Accuracy of Operating Max. ±1% Reset Max. 50ms Contact Form 4N/O + 4N/C, 3A 240VAC (resistance load) DC : 1.2W Power Consumption AC : 2VA Dielectric Strength 1,500VAC for 1 minute Mechanical Min. 1,000,000 Life Cycle Electrical Min. 200,000 Rated Voltage 220VAC 50/60 Hz, 110VAC 50/60 Hz, 24VDC. 12VDC Ambient Temperature -25 C ~ +70 C (with no icing) The specification and material of the product can be changed without notice for higher quality. Product Selection Data Processing Contact Form 4N/O + 4N/C 4N/O + 4N/C Unit SEC MIN Part Number Range 220VAC 110VAC 24VDC 12VDC 0.5 TTM-40.5S 220VAC TTM-40.5S 110VAC TTM-40.5S 24VDC TTM-40.5S 12VDC 1 TTM-4001S 220VAC TTM-4001S 110VAC TTM-4001S 24VDC TTM-4001S 12VDC 5 TTM-4005S 220VAC TTM-4005S 110VAC TTM-4005S 24VDC TTM-4005S 12VDC 10 TTM-4010S 220VAC TTM-4010S 110VAC TTM-4010S 24VDC TTM-4010S 12VDC 30 TTM-4030S 220VAC TTM-4030S 110VAC TTM-4030S 24VDC TTM-4030S 12VDC 60 TTM-4060S 220VAC TTM-4060S 110VAC TTM-4060S 24VDC TTM-4060S 12VDC 180 TTM-4180S 220VAC TTM-4180S 110VAC TTM-4180S 24VDC TTM-4180S 12VDC 5 TTM-4005M 220VAC TTM-4005M 110VAC TTM-4005M 24VDC TTM-4005M 12VDC 10 TTM-4010M 220VAC TTM-4010M 110VAC TTM-4010M 24VDC TTM-4010M 12VDC 30 TTM-4030M 220VAC TTM-4030M 110VAC TTM-4030M 24VDC TTM-4030M 12VDC 60 TTM-4060M 220VAC TTM-4060M 110VAC TTM-4060M 24VDC TTM-4060M 12VDC Dimension (mm) Socket Chart KMY4 KMY4S www.kacon.co.kr Industrial Controls Catalog Ⅲ - 57

Analog r TTS Series Part Number Description TTS - B ❶ ❷ 0.5S (0.5S/5S/30S/3M) 001S (1S/10S/60S/6M) 005S (5S/50S/5M/30M) 010S (10S/100S/10M/60M) ❶ Range 060S (60S/10M/60M/6H) 002M (2M/20M/2H/12H) 004M (4M/40M/4H/24H) S : Seconds M : Minutes H : Hours ❷ Supply Voltage 220VAC 110VAC 24VDC 110VDC General Specification Accuracy of Operating Max. ±0.5 Reset Contact Form Power Consumption Dielectric Strength Life Cycle Rated Voltage Max. 100ms 2N/O + 2N/C, 5A 240VAC (Resistance Load) DC : 1.2W AC : 2VA 1,500VAC for 1 minute Mechanical Min. 1,000,000 Electrical Min. 200,000 220VAC, 110VAC, 24VDC, 110VDC (±10% of the regular voltage) Ambient Temperature -25 C ~ +70 C The specification and material of the product can be changed without notice for higher quality. Ⅲ - 58 Industrial Controls Catalog www.kacon.co.kr

Data Processing Product Selection Contact Form Unit Range Part Number 220VAC 110VAC 110VDC 24VDC 0.5 TTS-B0.5S 220VAC TTS-B0.5S 110VAC TTS-B0.5S 110VDC TTS-B0.5S 24VDC 1 TTS-B001S 220VAC TTS-B001S 110VAC TTS-B001S 110VDC TTS-B001S 24VDC 5 TTS-B005S 220VAC TTS-B005S 110VAC TTS-B005S 110VDC TTS-B005S 24VDC 2N/O + 2N/C S 10 TTS-B010S 220VAC TTS-B010S 110VAC TTS-B010S 110VDC TTS-B010S 24VDC 30 TTS-B030S 220VAC TTS-B030S 110VAC TTS-B030S 110VDC TTS-B030S 24VDC 50 TTS-B050S 220VAC TTS-B050S 110VAC TTS-B050S 110VDC TTS-B050S 24VDC 60 TTS-B060S 220VAC TTS-B060S 110VAC TTS-B060S 110VDC TTS-B060S 24VDC 100 TTS-B0100S 220VAC TTS-B0100S 110VAC TTS-B0100S 110VDC TTS-B0100S 24VDC 2 TTS-B002M 220VAC TTS-B002M 110VAC TTS-B002M 110VDC TTS-B002M 24VDC 3 TTS-B003M 220VAC TTS-B003M 110VAC TTS-B003M 110VDC TTS-B003M 24VDC 4 TTS-B004M 220VAC TTS-B004M 110VAC TTS-B004M 110VDC TTS-B004M 24VDC 5 TTS-B005M 220VAC TTS-B005M 110VAC TTS-B005M 110VDC TTS-B005M 24VDC 6 TTS-B006M 220VAC TTS-B006M 110VAC TTS-B006M 110VDC TTS-B006M 24VDC Data Processing 2N/O + 2N/C M 10 TTS-B010M 220VAC TTS-B010M 110VAC TTS-B010M 110VDC TTS-B010M 24VDC 20 TTS-B020M 220VAC TTS-B020M 110VAC TTS-B020M 110VDC TTS-B020M 24VDC 30 TTS-B030M 220VAC TTS-B030M 110VAC TTS-B030M 110VDC TTS-B030M 24VDC 40 TTS-B040M 220VAC TTS-B040M 110VAC TTS-B040M 110VDC TTS-B040M 24VDC 50 TTS-B050M 220VAC TTS-B050M 110VAC TTS-B050M 110VDC TTS-B050M 24VDC 60 TTS-B060M 220VAC TTS-B060M 110VAC TTS-B060M 110VDC TTS-B060M 24VDC 2 TTS-B002H 220VAC TTS-B002H 110VAC TTS-B002H 110VDC TTS-B002H 24VDC 4 TTS-B004H 220VAC TTS-B004H 110VAC TTS-B004H 110VDC TTS-B004H 24VDC 2N/O + 2N/C H 6 TTS-B006H 220VAC TTS-B006H 110VAC TTS-B006H 110VDC TTS-B006H 24VDC 12 TTS-B012H 220VAC TTS-B012H 110VAC TTS-B012H 110VDC TTS-B012H 24VDC 24 TTS-B024H 220VAC TTS-B024H 110VAC TTS-B024H 110VDC TTS-B024H 24VDC Dimension (mm) Socket KF083A KPZ2 www.kacon.co.kr Industrial Controls Catalog Ⅲ - 59