Report No.: HZ c/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Similar documents
Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary

LM Test Report. for Maxlite Inc. LED Canopy Model: MLCAN20LED50

Report No.: HZ h/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ f. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

LM Test Report. for Maxlite SK America Inc. WALLPACK Model: MLSWP30LED50DS

LM Test Report. for Maxlite SK America Inc. 2*4 Retrofit Kits Model: RKT4514U5550DV

Report No.: HZ h. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

LM Test Report. for EiKO Global, LLC. 25W Floodlight Model: FLM-2C-N-U

Report No.: HZ w. Stabilization Time (Light & Power) CRI. Table 1: Executive Data Summary. Figure 1- Overview of the sample

Report No.: HZ j. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

LM Test Report. for. Philips (China) Investment Co., Ltd. InstantFit LEDtube Model:

Cat# LED Classic Large Wall-Pack

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 61-70)

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)

Morris Products 53 Carey Road, Queensbury, NY 12804

LM Test Report. for Elec-Tech International Co., Ltd. BR40 LAMP Model: XX(XX:01-10), WBR40L27S2A

Catalog Number UPC Number LED Spot Bullet Flood Light 42W 4204 Lumens White

LM Test Report. for Elec-Tech International Co.,Ltd. LED PAR30 Spot light Model: XX(XX:41-50)

Report No.: HZ k/R1. (Lumens) Stabilization Time CRI (K) (Light & Power) Table 1: Executive Data Summary

Catalog Number UPC Number LED Spot Bullet Flood Light 15W 1620 Lumens Bronze

Report No.: EASZE Page 2 of 14

Report No.: HZ c

Report No.: HZ a. 60 mins Note. 4000K, frosted lens Table 1: Executive Data Summary

Report No.: HZ d

LM Test. for LED. Cabinet

LM Test Report. For. T8 LEDTUBE Model: LED9WT8 F/24/850K-G7D

L Test Report. LED TUBE 1odel: LED11.5WT8/48/850-PET-G7DR

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006

Test Report. Report No.: EED35I Page 1 of 10. Customer : EIKO GLOBAL LLC Address : W 84TH ST SHAWNEE, KS USA

57-100W-XXK-WPH12-SG W-40K-WPH12-SG W-57K-WPH12-SG

Eternal Shine Technology Co.,Ltd. EST

Photometric Test Report

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires. Model name(s): WML-50W

NVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires. Model name(s): LWA-50W

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires

71332 LED Dusk To Dawn (Area Light)

NVLAP LAB CODE LM Test Report For. Outdoor Pole/Arm-mounted Area and Roadway Luminaires

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

Cat# LED Wall-PACK

NVLAP LAB CODE LM Test Report. For. Maxlite INC. (Brand Name: Maxlite) 12 York Ave., West Caldwell, NJ 07006

NVLAP LAB CODE LM Test Report. For EIKO GLOBAL, LLC W 84th St., Shawnee, KS

Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products

LED Floodlight. RoHS. Model: inner box: L 17" X W 12.5" X H 9.33" 1PCS AC 50/60HZ. Input Voltage 0.85A MAX. Input Current 78 W.

LM Test Report. For. Revolution Lighting Technologies, Inc. (Brand Name: ) 2280 Ward Ave. Simi Valley, CA

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

NVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires

LM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

NVLAP LAB CODE LM Test Report. For. Maxlite Inc. (Brand Name: ) 12 York Avenue, West Caldwell, NJ

LM Test Report

NVLAP LAB CODE LM Test Report. For SHENZHEN BONLD ELECTRONICS CO.,LTD. (Brand Name: BONLD)

Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products

LM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

Direct to wall VAC / 30W PF ,290 LM 110 LM/W B2-U0-G1. Alluminium + Tempered Glass 24-48VDC 0.

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

NVLAP LAB CODE LM Test Report. For GREEN LOGIC LED ELECTRICAL SUPPLY INC. Outdoor Full-Cutoff Wall-mounted Area Luminaire

TEST REPORT. Job No SHA Date: Apr 12,2017 REPORT NO SHA-006. TEST OF ONE LED Luminaire MODEL NO.

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

REVOLUTION LIGHTING TECHNOLOGIES INC

TEST REPORT. Job No SHA Date: February 19, 2017 REPORT NO SHA-003

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ

RoHS QPL ID # PLC6V1PABNUJS

LM Test Report. For. GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) Shenfubao Industry Park, Bonded area, Futian District,Shenzhen

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

NVLAP LAB CODE LM Test Report. For MAXLITE,INC. (Brand Name: N/A) 12 YORK AVENUE WEST CALDWELL,NJ 07006

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

RoHS QPL ID # P9JSE2P8. Cat# Watts Trunion Mount. Model: master carton: L*W*Hmm 1PCS. EPA Rating 1.

RoHS VAC 50/60HZ 0.38A Max W PF LM LM/W x 90

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

RoHS. Model: VAC 50/60HZ 0.127A Max 14.6 W PF LM LM/W x90 Aluminium Housing + Polycarbonate Lens

Cat# 71440A LED Classic Large Wall-Pack

71345A. 50W LED Floodlight Yoke(Bracket) Mount. RoHS QPL ID # PLDUWHES4P5Q. Model: 71345A

LM Test Report

NVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101

NVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101

Dimming: PWM/TIME/0-5V/0-10V. RoHS

LM Test Report. For KEYSTONE TECHNOLOGIES LLC. (Brand Name: KEYSTONE) 1390 Welsh Road North Wales, PA 19454

RoHS VAC 50/60HZ 1.8A Max 150W PF LM 123 LM/W x 90 Aluminium + PC Lens 36-60VDC 4.4A 88% Philips 3030 LED 36 PCS

71352A QPL ID # PLT2P2L2UNWR. RoHS

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

RoHS QPL ID # PNZ72BAB

RoHS. Dimming: PWM/VR/0-10V QPL ID # PL21D5Q1B95E. Cat# W FlatPanel Pole Mount. EPA Rating 2.33ft 2.

RoHS QPL ID # PNZ72BAB

QPL ID # PLG2YNJ831VZ

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name: N/A) 188 S. Northwest Highway Cary, IL 60013


NVLAP LAB CODE LM Test Report. For BEYOND LED TECHNOLOGY Mountain Industrial Blvd. Suite A-1 Tucker, GA USA

Dark Sky Wallpack 50W. General ACD12 Aluminum Heat Sink High Light Transmittance Polycarbonate, Anti-UV and Fire Resistant Finish:

RoHS. Model: VAC 50/60HZ.83A Max 100W

DRAFT. Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products. LCTECH (Zhongshan) Testing Service Co.

NVLAP LAB CODE LM Test Report. For ATG ELECTRONICS CORP. (Brand Name: N/A) th Street Rancho Cucamonga, CA 91730

NVLAP LAB CODE LM Test Report. For. LED Waves, Inc st. Ave. Brooklyn, NY USA. Linear Retrofit Kits for 2x2 Luminaires

Cat# 71146A 150W Trunion Mount

Transcription:

Test Summary Sample Tested: MLLWP40LED50DS Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 96.2 3353.0 34.85 0.9900 CCT (K) CRI Stabilization Time (Light & Power) 5122 85.6 75 Table 1: Executive Data Summary Test specifications: Date of Receipt : Nov. 20, 2014 Date of Test : Nov. 20, 2014 Test item : Total Luminous Flux, Luminous Distribution Intensity, Luminous Efficacy, Correlated Color Temperature, Color Rendering Index, Chromaticity Coordinate, Electrical parameters Reference Standard : IESNA LM-79-2008 Approved Method for the Electrical and Photometric Measurements of Solid-State Lighting Products Prepared by: Leading Testing Laboratories Page 2 of 14

TABLE OF CONTENT LM-79-08 Test Report... 1 Test Summary... 2 Photos... 4 TEST RESULTS... 5 Spectral Power Distribution... 6 Zonal Lumen Tabulation... 7 Illuminance Plots... 8 Luminous Intensity Distribution Plots... 10 Luminous Intensity Data... 11 EQUIPMENT LIST... 13 TEST METHODS... 13 Seasoning of SSL Product... 13 Goniophotometer Method... 13 Photometric and Electrical Measurements... 13 Color Characteristics Measurements... 14 Color Spatial Uniformity... 14 Prepared by: Leading Testing Laboratories Page 3 of 14

Photos Figure 1- Overview of the sample Equipment Under Test (EUT) Name : LED Wall Pack Model : MLLWP40LED50DS Electrical Ratings : 120~277V AC, 50/60Hz, 40W Product Description : 5000K, Outdoor Wall-Mounted Area Luminaires Manufacturer of light source: Philips Model of light source: Lumileds 35352D Quantity of LED light source: 56pcs Driver model: GP-C128S042PS Manufacturer : MaxLite, Inc. Address : 12 York Ave West Caldwell, NJ 07006 Prepared by: Leading Testing Laboratories Page 4 of 14

TEST RESULTS Test ambient temperature was 25.0. Base orientation was Light down. Test was conducted without a dimmer in the circuit. The stabilization time of the sample was 75 minutes, and the total operating time including stabilization was 100 minutes. Parameter Result Special Color Rendering Indices Test Voltage (V) 120.0 277.0 R1 84 Voltage frequency (Hz) 60 60 R2 91 Test Current (A) 0.293 0.134 R3 93 Power Factor 0.9900 0.9510 R4 84 Test Power (W) 34.85 35.25 R5 85 THD A% 7.66 4.77 R6 85 Luminous Efficacy (lm/w) 96.2 97.8 R7 89 Total Luminous Flux (lm) 3353.0 3447.5 R8 74 Color Rendering Index (CRI) 85.6 R9 27 R9 27 R10 77 Correlated Color Temperature (CCT) (K) 5122 R11 82 Chromaticity (Chroma x, Chroma y) (0.3421, 0.3536) R12 64 Chromaticity (Chroma u, Chroma v) (0.2086, 0.3235) R13 86 Chromaticity (Chroma u, Chroma v ) (0.2086, 0.4852) R14 96 Duv 0.0023 Average Beam Angle ( ) 111.0 Center Beam Candle Power (cd) 1213 Spacing Criteria 1.29 (0-180 )/ 1.30 (90-270 ) Zonal Lumens in the 0-60 Zone 83.14% Zonal Lumens in the 60-90 Zone 16.85% Zonal Lumens in the 90-120 Zone 0.00% Zonal Lumens in the 120-180 Zone 0.01% Table 2: Test data per Sphere-Spectroradiometer Method Note: According to CIE 1976 (u,v ) diagram, u = u = 4x/(-2x+12y+3), v = 3v/2 = 9y/(-2x+12y+3). Prepared by: Leading Testing Laboratories Page 5 of 14

Spectral Power Distribution Chart 1: Spectral Power Distribution Prepared by: Leading Testing Laboratories Page 6 of 14

Zonal Lumen Tabulation γ( ) Lumens % Total 0-10 114.808 3.42% 10-20 331.492 9.89% 20-30 510.808 15.23% 30-40 627.306 18.71% 40-50 650.823 19.41% 50-60 552.416 16.48% 60-70 369.382 11.02% 70-80 170.836 5.10% 80-90 24.762 0.74% 90-100 0.041 0.00% 100-110 0.046 0.00% 110-120 0.051 0.00% 120-130 0.049 0.00% 130-140 0.048 0.00% 140-150 0.043 0.00% 150-160 0.034 0.00% 160-170 0.022 0.00% 170-180 0.007 0.00% Total 3353.0 100% γ( ) Lumens % Total 0-60 2787.653 83.14% 60-90 564.98 16.85% 0-90 3352.633 99.99% 90-180 0.341 0.01% 0-180 3353.0 100% Table 3: Zonal Lumen Data Prepared by: Leading Testing Laboratories Page 7 of 14

Illuminance Plots Chart 2: Beam Angle Prepared by: Leading Testing Laboratories Page 8 of 14

Chart 3: Illuminance Plot (Footcandles) Prepared by: Leading Testing Laboratories Page 9 of 14

Luminous Intensity Distribution Plots Chart 4: Isocandela Plot Chart 5: Polar Candela Distribution Prepared by: Leading Testing Laboratories Page 10 of 14

Luminous Intensity Data Table 4: Luminous Intensity Data Prepared by: Leading Testing Laboratories Page 11 of 14

Table 5: Luminous Intensity Data Prepared by: Leading Testing Laboratories Page 12 of 14

EQUIPMENT LIST Test Equipment Model Equipment No. Calibration Date Calibration Due date Goniophotometer system GO-R5000 HZTE011-01 Sep. 18, 2014 Sep. 17, 2015 Digital Power Meter PF2010A HZTE028-01 Sep. 18, 2014 Sep. 17, 2015 AC Power Supply PCR 500L HZTE001-08 Sep. 18, 2014 Sep. 17, 2015 DC Power Supply WY12010 HZTE004-03 Sep. 18, 2014 Sep. 17, 2015 Temperature Meter TES1310 HZTE017-01 Sep. 18, 2014 Sep. 17, 2015 Standard source D908 HZTE012-01 Sep. 18, 2014 Sep. 17, 2015 TEST METHODS Table 6: Test Equipment List Seasoning of SSL Product For the purpose of rating new SSL products, SSL products shall be tested with no seasoning. Therefore, no seasoning was performed. Goniophotometer Method Photometric and Electrical Measurements An EVERFINE Type C Model GO-R5000 Goniophotometer was used to measure the intensity at each angle of distribution for each sample. The photometric distance is 2.475m for near-field measurement or 30m for far-field measurement. Bandwidth of spectroradiometer is 380nm-780nm. Ambient temperature was measured at the same height of the sample mounted on the Goniophotometer equipment. Each SSL unit was operated on the client provided driver at the rated input voltage in its designated orientation. The stabilization time typically ranges from 30 min (small integrated LED lamps) to 2 or more hours for large SSL luminaires). It can be judged that stability is reached when the variation (maximum minimum) of at least 3 readings of the light output and electrical power over a period of 30 min, taken 15 minutes apart, is less than 0.5 %. Electrical measurements including voltage, current, and power were measured using the Everfine Digital Power Meter. Some graphics were created with Photometric Plus software. The standard reference of the Goniophotometer system is halogen incandescent lamp, the intensity distribution type is omni-directional, and is traceable to the National Institute of Metrology P.R. China. The uncertainty of goniophotometer system reported in this document is expended uncertainty is 1.94% with a coverage factor k=2. Prepared by: Leading Testing Laboratories Page 13 of 14

Color Characteristics Measurements The color characteristics of SSL products include chromaticity coordinates, correlated color temperature, and color rendering index. These characteristics of SSL products may be spatially non-uniform, and thus, in order that they can be specified accurately, the color quantities shall be measured as values that are spatially average, weighted to intensity, over the angular range where light is intentionally emitted from the SSL product. The color characteristics measurements are using gonio-spectroradiometer. Color Spatial Uniformity The characteristics of SSL products may be spatially non-uniform, the chromaticity coordinate shall be measured at two vertical planes (C=0 /180 and C=90 /270 ) and at 10 or less intervals for vertical angle until the light output dropped to below 10% of the peak intensity. The averaged weighted chromaticity coordinate was calculated from these points. The data was then analyzed to check for delta color differences of the u', v' chromaticity coordinates. The spatial non-uniformity of chromaticity, u'v', is determined as the maximum deviation (distance on the CIE (u', v') diagram) among all measured points from the spatially averaged chromaticity coordinate. The geometry for the chromaticity measurement using gonio-spectroradiometer is shown as following. *** End of Report *** This report is considered invalidated without the Special Seal for Inspection of the LTL. This report shall not be altered, increased or deleted. The results shown in this test report refer only to the sample(s) tested. Without written approval of LTL, this test report shall not be copied except in full and published as advertisement Prepared by: Leading Testing Laboratories Page 14 of 14