HZO60 Outdoor Decorative Fireplace

Similar documents
Contemporary Collection

Contemporary Collection

U1500E Gas Fireplace

Contemporary Collection

Regency Bellavista B41XT-1 Gas Fireplace

Manual FOR YOUR SAFETY. Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance.

GAS FIREPLACES TRADITIONAL. TRADITIONAL GAS FIREPLACES

Zero Clearance Fireplace 36 ELITE-ZC INSTALLATION MANUAL. Listed Tested to: U.L. 127 and portions of U.L & 907. Part # $10.

GAS FIREPLACES TRADITIONAL. TRADITIONAL GAS FIREPLACES

GAS FIREPLACES TRADITIONAL. TRADITIONAL GAS FIREPLACES

Zero Clearance Fireplace 44 ELITE-ZC INSTALLATION MANUAL. Listed Tested to: U.L. 127 and portions of U.L & 907. Part # $10.

Never fill any required clearance space with insulation or any other building materials surrounding the chimney.

contemporary gas fireplaces

C Series. Cool Surface System INSTRUCTION MANUAL FRONT VENT [ ] PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE

INSUL-FLUE is used to reduce the danger of radiant heat from smoke pipe, flue pipe, gas vents, etc. igniting combustibles.

ProBuilder Linear CoolSmart TV (42PB - sku# )(54PB - sku# )(72PB - sku# )

WOOD FIRE FLUE KIT AND ACCESSORIES MANUAL

LE7000 Provincial Built-in (Zero Clearance) Kit Instructions.

The following manual is for the 80ZC cabinet ONLY. If you require information on the Model 80 unit that fits inside this cabinet, please download the

Installation Guide - Evolution Series Wood Siding

BUILT-IN EXTENDED HEIGHT GRILLE INSTALLATION GUIDE SPECIFICATIONS, INSTALLATION, AND MORE

Extended Height Grille for Built-In

2012 IMC Performing Commercial Mechanical Inspections

MM700R Recess Box Kit Addendum

ProBuilder Series CoolSmart TV (42PB - sku# )(54PB - sku# )(72PB - sku# )

gas fireplace inserts

ECOVENT USA CHIMNEY MODEL EV-SHT 5"-8" DIAMETER INSTALLATION INSTRUCTIONS

Fireside Retreat. Craftsman-Style BEFORE

150 MM FREE STANDING WOOD FIRE FLUE KIT INSTALLATION INSTRUCTIONS

Traditional & Contemporary PORTRAIT-STYLE DIRECT-VENT FIREPLACES

Crave Series. Direct Vent Gas Fireplaces

GRENADA / CALAIS ECS

GE Monogram. Installation. Instructions. 27" Built-In Ovens. Models ZEK757WW ZEK757BW ZEK737WW ZEK737BW

SOUTHWEST KIVA 24 FIREPLACE Prefabricated Masonry Wood Burning Firebox and Metal Frame

LRI6E LIBERTY RADIANT LARGE GAS INSERT RADIANT CONVECTIVE HEAT

HowtoPlans..org. 6'x8' Storage Shed Plan

Turada Hardwood Shingles and Shakes Installation instructions

GAS FIREPLACES INSERTS. GAS FIREPLACES INSERTS

Piping & Equipment Identification

DesIGneD to inspire. PREMIER Wood-Burning Fireplaces

GAS FIREPLACES INSERTS. GAS FIREPLACES INSERTS

SECTION IDENTIFICATION FOR PLUMBING PIPING AND EQUIPMENT

gas fireplace inserts woo

Montebello DLX with the stunning contemporary styling: Black Porcelain interior & Platinum media

INSTALLATION SHOP DRAWINGS FOR MINNEAPOLIS, MN

GE Monogram. Installation. Instructions. 36" Vent Hood. Model ZV750. Call anywhere in the US and Canada -

Installation Guide Classic Series Wood Siding

gas fireplace inserts

Chaska 34, Chaska 335s, Chaska 29, Chaska 25

FIRE RATED DOOR AND FRAME GENERAL REQUIREMENTS

650 C TEMP/GUARD CHIMNEY SIZES ºC TEMP/GUARD CHIMNEY

AC50 Enclosure - Thin Edge

Five Star Panel Installation Instructions

The first louverless direct-vent fireplace from Lennox with a classic masonry-built appearance and tall opening that accentuates a superb log set and

HRI4E REGENCY HORIZON MEDIUM GAS INSERT STANDARD FEATURES. HRI4E shown with Regular Backing Plate, Vignette Faceplate in Platinum and Black Crystals.

INSTALLATION, STORAGE AND WALL CONSTRUCTION DETAILS

SLP-LPC. Installation & Operating Instructions. SLP-LPC Preparation

DoctorFlue.com. gas fireplace. inserts

Installation Instructions For Slider Casement Air Conditioners

Regency Horizon HZ30E Contemporary Direct Vent Gas Fireplace

CHASKA 34, CHASKA 335S, CHASKA 29, CHASKA 25

NEW HOME WARRANTY A REFERENCE GUIDE FOR TYPICAL WALL AND WINDOW DETAILS (RAINSCREEN SYSTEM) SHOWN AS FIBRE CEMENT CLADDING

TRUE TRIMLESS GAS FIRES EDITION

HEARTH PRODUCTS KITS AND ACCESSORIES VERTICAL TERMINATION KITS FOR SECURE FLEX VERTICAL VENTING

INSTALLATION INSTRUCTION FOR WOOD DOUBLE-HUNG AND CASEMENT WINDOWS USING WOOD BRICKMOULD OR FLAT CASING

LP SmartSide Soffit ON SITE STORAGE PREPARATION. Application Instructions Vented and Non-Vented Smooth Finish or Cedar Texture. General Information

CHASKA 34, CHASKA 335S, CHASKA 29, CHASKA 25

DaVinci Fireplace See Through Indoor / Outdoor Framing and Window Installation Instructions

How-To Assemble Your SERENITY 100

INSTALLATION INSTRUCTION INSTRUCCIONES DE INSTALACIÓN FOR CLAD HINGED PATIO DOOR PUERTA DE BISAGRA PARA PATIO

A great addition to Sub-Zero's complete line of

GE Monogram. Installation. Instructions. Microwave Oven. Under Cabinet Installation. and. JX827 Series Built-In Kit. Models.

Install Instructions for Corvallis #4008GRC Mantel

Installation Guide for Andersen 400 Series Tilt-Wash Transom and 200 Series Narroline Transom Windows

INSERTS GAS FIREPLACE. GAS FIREPLACE INSERTS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS

Windows Installed into Walls with Polyiso and Wood Framing. Installation Instructions Standard Method Revised 10/24/2016

Windows Installed into Walls with Polyiso and Wood Framing. Installation Instructions Picture Frame Method Revised 10/24/2016

MEZZO. Direct Vent Gas Fireplace

TRADE SILL FLASHING TAPE. Product. Scope. Appraisal No. 712 [2012] Appraisal No. 712 (2012) Amended 19 July BRANZ Appraisals

Before You Begin... TOOLS & PRODUCT INVENTORY

MEZZO DIRECT VENT GAS FIREPLACE

Sections & Details VOCABULARY

ROOFING APPLICATION STANDARD (RAS) No. 130

MM540 Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACIÓN FOR CLAD CASEMENT & AWNING WINDOW VENTANA DE DOS HOJAS CON REVESTIMIENTO

GARAGE DOOR WITH TORSION SPRING

DURATECH CHIMNEY 5"-8" DIAMETER INSTALLATION INSTRUCTIONS

Installation Instructions

INSTALLATION INSTRUCTION FOR CLAD BOW WINDOWS WITHOUT HEAD AND SEAT BOARD

Grand Garden Chalet 6X3 Assembly Manual - Costco

Resysta 6 and 4 Flat Board Siding System Assembly Installation Guidelines

Best Barns USA Assembly Book

MM340 Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

ROOFING APPLICATION STANDARD (RAS) No. 130 INSTALLATION CRITERIA FOR WOOD SHINGLES AND SHAKES APPLICATION

Sections & Details. WOOD SILL and FLOOR CONSTRUCTION NOTES

MM750 Installation Instructions

HowtoPlans..org. Luxe 12'x6' Garden Shed Plan

Installation Instructions

Best Barns USA Assembly Book

Transcription:

Specifications: HZO60 Outdoor Decorative Fireplace Model HZO60-NG HZO60-LP Fuel Type Natural Gas Propane Gas Minimum Supply Pressure Minimum Supply Pressure Manifold Pressure - High 14 W.C. (3.49 kpa) 5 W.C. (1.25 kpa) 3.5 W.C. (0.87 kpa) 14 W.C. (3.49 kpa) 11 W.C. (2.74 kpa) 10 W.C. (2.49 kpa) Orifice Size #11 DMS #42w DMS Maximum Input Altitude 0-4500 ft. 64,000 Btu/h (18.76 kw) 62,000 Btu/h (18.17 kw) Vent Sizing No Vent No Vent UNIT DIMENSIONS - HZO60 SINGLE SIDED 68 5 8 " 1744 63 5 16 " 1608 58 7 8 " 1495 15 1 2 " 394 11 1 4 " 286 16 3 8 " 417 28 7 16 " 723 32 1 16 " 814 22 9 16 " 573 60 3 " 8 [1535] 8" 203 21 1 16 " 535 17 1 4 " [438]

UNIT DIMENSIONS - HZO60 SEE THROUGH 68 5 8 " 1744 63 5 16 " 1608 58 7 8 " 1495 15 1 2 " 394 11 1 4 " 286 16 3 8 " 417 28 7 16 " 723 32 1 16 " 814 18 1 2 " 8" 203 470 60 3 8 " [1535] 17 1 4 " [438]

LOCATING YOUR OUTDOOR DECORATIVE GAS APPLIANCE 1) When selecting a location for your outdoor decorative gas appliance, ensure that the clearances are met. 2) This appliance must be installed in an open-air situation with natural ventilation, without stagnant areas, where gas leakage and products of combustion are rapidly dispersed by wind and natural convection. 3) Certain materials or items, when placed under or near the appliance, will be subjected to radiant heat and could become damaged. 4) Typically an outdoor space is not enclosed but, any enclosure in which the appliance is used shall comply with one of the following: An enclosure with walls on all sides, but at least one permanent opening at ground level and no overhead cover. Within a partial enclosure that includes an overhead cover and no more that two walls. Within a partial enclosure that includes an overhead cover and more than two walls, the following shall apply: At least 25% of the total wall area is completely open, and At least 30% of the remaining wall area is open and unrestricted 30% or more in total of the remaining wall area is open and unrestricted. Open side at least 25% of total wall area

MINIMUM CLEARANCES TO COMBUSTIBLES The clearances listed below are Minimum distances unless otherwise stated: A major cause of fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fireplace be installed only in accordance with these instructions. Caution Requirements The top, back and sides of the fireplace are defined by standoffs. The metal ends of the standoff may NOT be recessed into combustible construction. WARNING Fire hazard is an extreme risk if these clearances (air space) to combustible materials are not adhered to. It is of greatest importance that this fireplace be installed only in accordance with these instructions. HZO60 External Clearance Requirements Clearance: Dimension Measured From: A: Sidewall 11" (203mm) Side of Fireplace Opening B: Ceiling 36" (914mm) Top of Fireplace Opening C: Mantel Height (min.) 22" (559mm) Top of Fireplace Opening D: Mantel Depth (max.) 12" (304mm) From Wall E: Alcove Width 86"(2184mm) Wall to Wall (Minimum) F: Alcove Depth 36" (914mm) Front to Back Wall (Maximum) Notes: 0" No Hearth Required WARNING: When installing this appliance; do not cover or surround with insulation. This appliance can overheat and cause malfunction and component failure, if covered, or partially covered. If the appliance is installed inside a chase, insulation must be installed on the walls of the chase, not on the appliance. B D B C A F A E E F Alcove

FRAMING DIMENSIONS SINGLE SIDED Framing Dimensions Description HZO60 A Framing Height 40-1/4" (1022mm) B Framing Width 69" (1753mm) C Minimum framing depth 22-1/4" (565mm) D Minimum Height to Combustibles (Chase Enclosure) 43-3/4" (1111mm) F Corner Wall Depth 76-13/16" (1951mm) G Corner Facing Wall Width 108-5/8" (2759mm) H Gas Connection Opening Height 2" (51mm) I Gas Connection Height 3-11/16 " (93mm) J1 Gas Connection Inset 6-3/16" (157mm) J2 Gas Connection Inset 6-3/16" (157mm) K Gas Connection Opening Width 3" (76mm) * Framing depth measurement is noted with the nailing strips set as far forward on the firebox as possible. The nailing strips can be adjusted back up to 1 to allow for varying thicknesses in non-combustible material & wall finishes. Note: All other framing may be of wood construction. Steel studs A Metal Stud on edge H B C I D J1 J2 K F G Important Note: Two (2) ventilation grills are highly recommended for all enclosures. This is to alleviate moisture and allow for air to circulate. Minimum recommended size: 20" sq (508 mm²) ea.

FRAMING DIMENSIONS SEE THROUGH Framing Dimensions Description HZO60 See Through A Framing Height 40-1/4" (1022mm) B Framing Width 69" (1753mm) C Minimum framing depth 18-1/2"" (470mm) **minus 2X the finished material thickness D Minimum Height to Combustibles (Chase Enclosure) 43-3/4" (1111mm) H Gas Connection Opening Height 2" (51mm) I Gas Connection Height 3-11/16 " (93mm) J1 Gas Connection Inset 6-3/16" (157mm) J2 Gas Connection Inset 6-3/16" (157mm) K Gas Connection Opening Width 3" (76mm) **Finished material thickness includes: non combustible material, tile slate, etc. (example framing = 18-1/2" - if 2" thick finishing material is used (on both sides)=14-1/2" framing depth. Note: Consideration should be given to weather / elements when choosing framing materials (ie. treated lumber, steel stud). Note: All other framing may be of wood construction. Metal Stud on edge H Steel studs A I B C J1 J2 K D Important Note: Two (2) ventilation grills are highly recommended for all enclosures. This is to alleviate moisture and allow for air to circulate. Minimum recommended size: 20" sq (508 mm²) ea.

8 MANTEL CLEARANCES (SINGLE SIDED AND SEE THROUGH) HZO60 Outdoor Decorative Gas Fireplace Due to the extreme heat this fireplace emits, the mantel clearances are critical. Combustible mantel clearances from top of front facing are shown in the diagram on the right. 14 12 10 8 6 4 Combustible Material 0 2 2 0 4 6 10 12 14 Note: Ensure the paint that is used on the mantel and the facing is "heat resistant" or the paint may discolour. 20 12" (305mm) Metal Stud (On Edge) 12" (305mm) 20 1" (25mm) 1" (25mm) 10 22" Non-combustible Facing 22" 10 13" Standoff 13" 0 To Unit Base 28-7/16" Top of Fireplace Opening Top of Fireplace Opening 28-7/16" To Unit Base 0 MANTEL LEG CLEARANCES (SINGLE SIDED AND SEE THROUGH) 16" (406mm) 16" (406mm) 9" (229mm) 5" (127mm) 9" (229mm) 5" (127mm) 8-1/2" 8-1/2" HZO60 8-1/2" 8-1/2" 5" (127mm) 9" (229mm) 5" (127mm) 9" (229mm) 16" (406mm) 16" (406mm)

NON-COMBUSTIBLE REQUIREMENTS 70-1/2" (1791mm) 13" (330mm) Non-combustible Material 17-1/4" (438mm) Non-combustible Material 60-3/8" (1534mm) 41-1/2" (1054mm) 11-1/4" (286mm) Combustible Material 5" (127mm) 5" (127mm)

FRAMING & FINISHING HZO60 Outdoor Decorative Gas Fireplace 1. Frame in the enclosure for the unit with framing material. IMPORTANT: Vertical studs and the header must be metal. Note: When constructing the framed opening, please ensure there is access to install the gas lines when the unit is installed. 2. The unit does not have to be completely enclosed in a chase. You must maintain clearances from the vent to combustible materials: See "Clearances" section. Combustible materials can be laid against the side and back standoffs and the stove base. 3. Non-combustible material (ie. tile, slate, etc) may be brought up to and overlap the unit (top and bottom) ensuring that the maximum thickness does not go beyond the 1-1/2" as shown in the diagram below. The faceplate will not be able to be mounted if the finished material is beyond 1-1/2". See Step 4 if facing/finishing materials will be more than 1-1/2". Finished Material Nailing Strip Position 1/2" 1" 1" 1/2" Nailing Strip 1 Forward Unit Nailing Strip ½ Forward Unit 1-1/2" 0" Nailing Strip Flush w/unit Factory Set Unit 1-1/2" (38mm) Single sided & see through 1-1/2" (38mm) (See-through) Note: Depending on the material used for finishing, the nailing strips must be set accordingly so that the finished material is always at the 1-1/2" edge of the flange. 4. If material such as brick, stone, etc. extends past the faceplate depth, when finishing around the faceplate, the minimum opening dimensions noted below must be adhered to ensuring for the removal of the faceplate and for the safe operation of this appliance. 64-3/16" 21-3/4"