Specifications: HZO60 Outdoor Decorative Fireplace Model HZO60-NG HZO60-LP Fuel Type Natural Gas Propane Gas Minimum Supply Pressure Minimum Supply Pressure Manifold Pressure - High 14 W.C. (3.49 kpa) 5 W.C. (1.25 kpa) 3.5 W.C. (0.87 kpa) 14 W.C. (3.49 kpa) 11 W.C. (2.74 kpa) 10 W.C. (2.49 kpa) Orifice Size #11 DMS #42w DMS Maximum Input Altitude 0-4500 ft. 64,000 Btu/h (18.76 kw) 62,000 Btu/h (18.17 kw) Vent Sizing No Vent No Vent UNIT DIMENSIONS - HZO60 SINGLE SIDED 68 5 8 " 1744 63 5 16 " 1608 58 7 8 " 1495 15 1 2 " 394 11 1 4 " 286 16 3 8 " 417 28 7 16 " 723 32 1 16 " 814 22 9 16 " 573 60 3 " 8 [1535] 8" 203 21 1 16 " 535 17 1 4 " [438]
UNIT DIMENSIONS - HZO60 SEE THROUGH 68 5 8 " 1744 63 5 16 " 1608 58 7 8 " 1495 15 1 2 " 394 11 1 4 " 286 16 3 8 " 417 28 7 16 " 723 32 1 16 " 814 18 1 2 " 8" 203 470 60 3 8 " [1535] 17 1 4 " [438]
LOCATING YOUR OUTDOOR DECORATIVE GAS APPLIANCE 1) When selecting a location for your outdoor decorative gas appliance, ensure that the clearances are met. 2) This appliance must be installed in an open-air situation with natural ventilation, without stagnant areas, where gas leakage and products of combustion are rapidly dispersed by wind and natural convection. 3) Certain materials or items, when placed under or near the appliance, will be subjected to radiant heat and could become damaged. 4) Typically an outdoor space is not enclosed but, any enclosure in which the appliance is used shall comply with one of the following: An enclosure with walls on all sides, but at least one permanent opening at ground level and no overhead cover. Within a partial enclosure that includes an overhead cover and no more that two walls. Within a partial enclosure that includes an overhead cover and more than two walls, the following shall apply: At least 25% of the total wall area is completely open, and At least 30% of the remaining wall area is open and unrestricted 30% or more in total of the remaining wall area is open and unrestricted. Open side at least 25% of total wall area
MINIMUM CLEARANCES TO COMBUSTIBLES The clearances listed below are Minimum distances unless otherwise stated: A major cause of fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fireplace be installed only in accordance with these instructions. Caution Requirements The top, back and sides of the fireplace are defined by standoffs. The metal ends of the standoff may NOT be recessed into combustible construction. WARNING Fire hazard is an extreme risk if these clearances (air space) to combustible materials are not adhered to. It is of greatest importance that this fireplace be installed only in accordance with these instructions. HZO60 External Clearance Requirements Clearance: Dimension Measured From: A: Sidewall 11" (203mm) Side of Fireplace Opening B: Ceiling 36" (914mm) Top of Fireplace Opening C: Mantel Height (min.) 22" (559mm) Top of Fireplace Opening D: Mantel Depth (max.) 12" (304mm) From Wall E: Alcove Width 86"(2184mm) Wall to Wall (Minimum) F: Alcove Depth 36" (914mm) Front to Back Wall (Maximum) Notes: 0" No Hearth Required WARNING: When installing this appliance; do not cover or surround with insulation. This appliance can overheat and cause malfunction and component failure, if covered, or partially covered. If the appliance is installed inside a chase, insulation must be installed on the walls of the chase, not on the appliance. B D B C A F A E E F Alcove
FRAMING DIMENSIONS SINGLE SIDED Framing Dimensions Description HZO60 A Framing Height 40-1/4" (1022mm) B Framing Width 69" (1753mm) C Minimum framing depth 22-1/4" (565mm) D Minimum Height to Combustibles (Chase Enclosure) 43-3/4" (1111mm) F Corner Wall Depth 76-13/16" (1951mm) G Corner Facing Wall Width 108-5/8" (2759mm) H Gas Connection Opening Height 2" (51mm) I Gas Connection Height 3-11/16 " (93mm) J1 Gas Connection Inset 6-3/16" (157mm) J2 Gas Connection Inset 6-3/16" (157mm) K Gas Connection Opening Width 3" (76mm) * Framing depth measurement is noted with the nailing strips set as far forward on the firebox as possible. The nailing strips can be adjusted back up to 1 to allow for varying thicknesses in non-combustible material & wall finishes. Note: All other framing may be of wood construction. Steel studs A Metal Stud on edge H B C I D J1 J2 K F G Important Note: Two (2) ventilation grills are highly recommended for all enclosures. This is to alleviate moisture and allow for air to circulate. Minimum recommended size: 20" sq (508 mm²) ea.
FRAMING DIMENSIONS SEE THROUGH Framing Dimensions Description HZO60 See Through A Framing Height 40-1/4" (1022mm) B Framing Width 69" (1753mm) C Minimum framing depth 18-1/2"" (470mm) **minus 2X the finished material thickness D Minimum Height to Combustibles (Chase Enclosure) 43-3/4" (1111mm) H Gas Connection Opening Height 2" (51mm) I Gas Connection Height 3-11/16 " (93mm) J1 Gas Connection Inset 6-3/16" (157mm) J2 Gas Connection Inset 6-3/16" (157mm) K Gas Connection Opening Width 3" (76mm) **Finished material thickness includes: non combustible material, tile slate, etc. (example framing = 18-1/2" - if 2" thick finishing material is used (on both sides)=14-1/2" framing depth. Note: Consideration should be given to weather / elements when choosing framing materials (ie. treated lumber, steel stud). Note: All other framing may be of wood construction. Metal Stud on edge H Steel studs A I B C J1 J2 K D Important Note: Two (2) ventilation grills are highly recommended for all enclosures. This is to alleviate moisture and allow for air to circulate. Minimum recommended size: 20" sq (508 mm²) ea.
8 MANTEL CLEARANCES (SINGLE SIDED AND SEE THROUGH) HZO60 Outdoor Decorative Gas Fireplace Due to the extreme heat this fireplace emits, the mantel clearances are critical. Combustible mantel clearances from top of front facing are shown in the diagram on the right. 14 12 10 8 6 4 Combustible Material 0 2 2 0 4 6 10 12 14 Note: Ensure the paint that is used on the mantel and the facing is "heat resistant" or the paint may discolour. 20 12" (305mm) Metal Stud (On Edge) 12" (305mm) 20 1" (25mm) 1" (25mm) 10 22" Non-combustible Facing 22" 10 13" Standoff 13" 0 To Unit Base 28-7/16" Top of Fireplace Opening Top of Fireplace Opening 28-7/16" To Unit Base 0 MANTEL LEG CLEARANCES (SINGLE SIDED AND SEE THROUGH) 16" (406mm) 16" (406mm) 9" (229mm) 5" (127mm) 9" (229mm) 5" (127mm) 8-1/2" 8-1/2" HZO60 8-1/2" 8-1/2" 5" (127mm) 9" (229mm) 5" (127mm) 9" (229mm) 16" (406mm) 16" (406mm)
NON-COMBUSTIBLE REQUIREMENTS 70-1/2" (1791mm) 13" (330mm) Non-combustible Material 17-1/4" (438mm) Non-combustible Material 60-3/8" (1534mm) 41-1/2" (1054mm) 11-1/4" (286mm) Combustible Material 5" (127mm) 5" (127mm)
FRAMING & FINISHING HZO60 Outdoor Decorative Gas Fireplace 1. Frame in the enclosure for the unit with framing material. IMPORTANT: Vertical studs and the header must be metal. Note: When constructing the framed opening, please ensure there is access to install the gas lines when the unit is installed. 2. The unit does not have to be completely enclosed in a chase. You must maintain clearances from the vent to combustible materials: See "Clearances" section. Combustible materials can be laid against the side and back standoffs and the stove base. 3. Non-combustible material (ie. tile, slate, etc) may be brought up to and overlap the unit (top and bottom) ensuring that the maximum thickness does not go beyond the 1-1/2" as shown in the diagram below. The faceplate will not be able to be mounted if the finished material is beyond 1-1/2". See Step 4 if facing/finishing materials will be more than 1-1/2". Finished Material Nailing Strip Position 1/2" 1" 1" 1/2" Nailing Strip 1 Forward Unit Nailing Strip ½ Forward Unit 1-1/2" 0" Nailing Strip Flush w/unit Factory Set Unit 1-1/2" (38mm) Single sided & see through 1-1/2" (38mm) (See-through) Note: Depending on the material used for finishing, the nailing strips must be set accordingly so that the finished material is always at the 1-1/2" edge of the flange. 4. If material such as brick, stone, etc. extends past the faceplate depth, when finishing around the faceplate, the minimum opening dimensions noted below must be adhered to ensuring for the removal of the faceplate and for the safe operation of this appliance. 64-3/16" 21-3/4"