Digital Input Output Module for Zone 2 Series 9470/33

Similar documents
Digital Input Output Module for Zone 2 Series 9470/33

Digital Input Output Module for Zone 1 Series 9470/32

Analog Universal Module HART for Zone 2 Series 9468/33

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Temperature Input Module for Zone 1 Series 9482/32

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

Binary Output Series 9175

Remote I/O. 74 Remote I/O. Remote I/O System

Binary Output without Power Supply Series 9176

Isolators A3/1. Vibration Transducer Supply Unit Series

Isolators A3/1.

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

Isolating Repeater Input Series 9163

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

Fieldbus Isolating Repeater Series 9185/11

Isolators A3/1.

Digital I/O Coupler (4-wire) Series 9413/21

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

Two-channel safety barriers Series 9002

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

Two-channel safety barriers Series 9002

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

Single-Channel Safety Barriers Series 9001

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

Isolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/

2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC

Assembly. Front view. HiC2441. SL2 1b. Termination Board

Data Sheet KFD2-UFC-EX1.D. Supplied by. .com. Call us on +44 (0)

Engineering Guideline. pac-carriers Type for Yokogawa Centum VP

Inductive sensor slot-type SI2-K08-AP7

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Specifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift

EP-5111, EP-5112, EP-5212, EP-5261, EP-5311, EP-5422, EP-5442

Assembly. Front view. Switch Power Rail

Rail mounted Temperature Transmitter TH102/TH102-Ex

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Technical Data. General specifications. Rated operating distance s n 3 mm

Assembly. Front view. Switch Power Rail

Head mounted Temperature Transmitter TF02/TF02-Ex

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Temperature transmitter itemp PCP DIN rail TMT 121

onlinecomponents.com

PRetrans Table of contents

Field indicator for current loops with HART communication Models DIH50, DIH52

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Field indicator for current loops with HART communication Models DIH50, DIH52

Assembly. Front view. Parametrization interface. Power Bus

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Positioner with HART Communication Type 3780

ISOLATING SWITCHING AMPLIFIERS POWER SUPPLIES

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

Safety Instructions Nivotester FTC625, FTC325

Assembly. Front view. LED yellow: Relay output I. LED red: LB/SC channel I. LED yellow: Relay output II. LED red: LB/SC channel II

SINEAX TI 807 Passive DC signal isolator

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:

MACX MCR-EX-SL-RPSSI-I-UP(-SP)

A6500-UM Universal Measurement Card

Temperature Transmitter itemp RTD DIN rail TMT 127

Assembly. Front view. LED yellow: Relay output I. LED red: LB/SC channel I. LED yellow: Relay output II. LED red: LB/SC channel II

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

0 2 1 â Ó. itemp HART TMT182. Technical Information

0 2 1 â Ó. itemp HART TMT182. Technical Information

MACX MCR-EX-SL-RPSSI-I

D1072. SIL 2 Temperature Signal Converter, Duplicator, Adder/Subtractor DIN-Rail Models D1072S, D1072D. Front Panel and Features:

Rotary Measuring Technology

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Indicomp 2, Indicomp 2-Ex. Indicator and alarm signalling unit 10/ EN

SINEAX TV809, 1 channel Programmable Isolating Amplifier

Incremental encoders Blind hollow shaft or cone shaft pulses per revolution

Actuators Series 8602/3

BAR-ANT-N-N-EX. Antenna barrier for the hazardous area. Data sheet. 1 Description

Rudder or propeller angular position transmitter KINAX WT720

Control Unit Series 8208

Technical Information RMA42

Operating Manual. isolate501

Signal conditioner - MACX MCR-UI-UI-NC

TR 104, TR 104-Ex Rail mounted Temperature Transmitters

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique

Technical Information Barrier RB223

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

General Specifications

Product Manual 5202 Pulse isolator

DIN Rail Devices. CEAG Sicherheitstechnik GmbH 194

Incremental encoders Redundant sensing, isolated blind hollow shaft ø mm, cone shaft ø17 mm pulses per revolution

Overcurrent Protection / 7SJ45

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview

SALES SERVICE +358 (0)

Transcription:

www.stahl.de > 16 channels can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 channels can be used as frequency/counter input; with rotation direction recognition > Line fault monitoring per channel > Diagnostics based on NE107 > Module can be replaced in the hazardous area under power (hot swap) 15233E00 The Digital Input Output Module is used for connecting of up to 16 intrinsically safe digital signals to the IS1 Remote I/O system. All channels can be parameterised in pairs as input for connection of passive contacts or NAMUR proximity switches (EN 60947-5-6) or as output for connection of low power solenoid valves. Up to 8 inputs can be used as frequency inputs or counters up to 20 khz, in operating mode "Rotation direction recognition" and "Forward/backward counter" up to 4 inputs. The Ex i inputs or outputs are short-circuit proof and galvanically separated from the system. Compatible spare for IS1 I/O modules: Series 9470/12, 9470/22, 9475/12-08-41 ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2 Ex interface x x x x x x Ex interface x x x x x x Ex interface x x x x x x Installation in x x x Installation in x x x Installation in x x x WebCode 9470D Remote I/O /1

Explosion Protection Global (IECEx) Gas and dust IECEx DEK 12.0044X Ex na ia [ia Ga] IIC T4 Gc [Ex ia Da] IIIC Europe (ATEX) Gas and dust DEKRA 12ATEX0099X E II 3 (1) G Ex na ia [ia Ga] IIC T4 Gc USA (FM) E II (1) D [Ex ia Da] IIIC in preparation Certifications and certificates Certificates Ship approval Further parameters Installation Further information Safety data Max. voltage U o Max. internal inductance L i 1 channel Max. current I o Max. power P o Max. internal capacity C i Max. connectable inductance L o/ capacity C o IIC ATEX, IECEx, Brazil (INMETRO), Canada (cfm), Rusia (GOST R), USA (FM), Belarus (operating authorisation) ABS, BV, ClassNK, DNVGL, LR, RS in Zone 2, Zone 21, Zone 22 and in the safe area for further interconnections (4, 8 or 16 channels), see operating instructions and certificates 9.8 V negligible 10.4 ma 25.5 mw 2.5 nf L o [mh] 280 100 50 20 10 5 2 1 0.5 0.2 0.1 0.02 C o [μf] 0.49 0.56 0.64 0.72 0.81 0.96 1.1 1.3 1.6 2 3.3 IIB/IIIC L o [mh] 1000 100 50 20 10 5 2 1 0.5 0.2 0.1 0.01 C o [μf] 2.6 2.8 3.3 3.7 4.2 5.1 6 7.2 9.3 12 23 2 channels in parallel Max. current I o Max. power P o Max. internal capacity C i Max. connectable inductance L o/ capacity C o IIC 20.8 ma 51 mw 5 nf L o [mh] 100 50 20 10 5 2 1 0.5 0.2 0.1 0.02 C o [μf] 0.3 0.44 0.57 0.67 0.77 0.93 1.1 1.3 1.6 2 3.3 IIB/IIIC L o [mh] 270 100 50 20 10 5 2 1 0.5 0.2 0.1 0.01 C o [μf] 2.3 2.6 3.1 3.6 4.1 5.1 6 7.2 9.3 12 23 Selection Table Version Description Installation Order number Weight kg Digital Input Output Module Note 16 channels with adjustable parameters for contacts, NAMUR proximity switches or low-power solenoid valves Zone 2 9470/33-16-10 0.275 Please order 2 terminals separately - see Accessories /2 Remote I/O

Technical Data Electrical data Ex i inputs/outputs Number of channels 16 (in pairs with adjustable parameters as input or output) Inputs Max. number of channels 16 Min. input signal ON 2.1 ma Max. input signal OFF 1.2 ma Operating point 1.65 ma Supply voltage 8.2 V Internal resistance 1 kω Signal EN 60947-5-6 (NAMUR) Frequency input Max. number of channels 8 Max. switching frequency 20 khz (at frequencies > 1 khz the maximum conductor length is reduced, e.g. at 5 khz to approx. 75 m) Min. pulse width 25 μs Counter Max. number of channels 8 Counting range 0... 65535 als UINT16 Rotation direction recognition, forward/backward counter Max. number of channels 4 (each two inputs switched in parallel) Function Up/down counter; Frequency with direction Resolution 16 bit / 32 bit Outputs Max. number of channels 16 Application Ex i low-power solenoid valves Open-circuit voltage 8.2 V Max. output current 8.2 ma Internal resistance 1 kω Rated operation 6 V / 2 ma Output characteristic Signal transmission Max. delay from signal / internal bus Max. delay from frequency input / internal bus Measuring range 0.1 Hz 600 Hz 1 Hz 3 khz 1 Hz 20 khz Resolution 0.01 Hz 0.05 Hz 0.5 Hz Accuracy 0.1 % 0.1 % 0.1 % U[V] 9470/3. - Output 8 7 6 5 4 3 2 1 0 0 2 4 6 8 I[mA] < 1 ms Filter without small medium large Frequency 0.1 Hz ( f < 1 Hz 1/f + 1 ms 2/f 3/f 6/f 1 Hz ( f < 10 Hz 1/f + 1 ms 4/f 9/f 18/f 10 Hz ( f < 100 Hz 1/f + 1 ms 8/f 27/f 54/f 100 Hz ( f < 1 khz 1/f + 1 ms 16/f 81/f 162/f 1 khz ( f < 1960 Hz 1.5 ms 32/f 243/f 486/f 1960 Hz ( f < 10 khz 1.5 ms 16.5 ms 124 ms 248 ms 10 khz ( f < 20 khz 1.5 ms 33 ms 372 ms 744 ms f ) 20 khz 1.5 ms 66 ms 372 ms 744 ms 15284E00 Remote I/O /3

Technical Data Electrical data Galvanic separation Test voltage acc. to standard EN 60079-11 Between auxiliary power/ ) 1500 V AC system components Between two I/O modules ) 500 V AC Between I/O channels/ ) 500 V AC system components Between I/O channels/ ) 500 V AC ground (PA) Electromagnetic compatibility Tested to the following standards and regulations: EN 61326-1 (2006) IEC 61000-4-1 6, NAMUR NE 21 Electrical connection Power supply BusRail Types 9494 Ex i field signals Pluggable, blue terminals, 16-pole, 2.5 mm 2, screw- or spring-type versions with lock Auxiliary power Version Intrinsically safe Ex ia via BusRail Max. current consumption 120 ma Max. power consumption 2.5 W Max. power dissipation 2.5 W Device-specific data Settings Module Diagnostics message ON / OFF Signal Signal type Input / output*) Pulse extension / 0 s / off; 0.6 s / small; 1.2 s / medium; 2.4 s / large *) frequency filter Inverting input/output normal / inverted*) Line fault monitoring ON / OFF Behaviour in case of error Replacement value '0'; replacement value '1'; hold (initial value 0); hold (initial value 1) Operating mode counter/ frequency Counter control Counting event Counter 16 bit; 0.1... 600 Hz; 1 Hz... 3 khz; 1 Hz... 20 khz; 1 Hz... 20 khz with direction; up/down counter 16 bit; up/down counter 32 bit*) Run, Stop, Reset positive slope; negative slope*) *) setting is made for channel pairs Ambient conditions Ambient temperature -40 +75 C (observe operating instructions) Storage temperature -40 +80 C Maximum relative humidity 95 % (without condensation) Semi-sinusoidal shock (IEC EN 15 g (3 shocks per axis and direction) 60068-2-27) Sinusoidal vibration (IEC EN 60068-2-6) Mechanical data Degree of protection (IEC 60529) Module enclosure Fire resistance (UL 94) Pollutant class Dimensions 1 g in the frequency range 10... 500 Hz 2 g in the frequency range 45... 100 Hz IP20 polyamide 6GF V2 corresponds to G3 L = 128 mm, W = 96.5 mm, H = 67 mm /4 Remote I/O

Technical Data Indication LED indication Module requires maintenance Operating state Group error Function indication Retrievable parameters Error indication Module status and alarms LED "M/S", blue LED "RUN", green LED "ERR", red Manufacturer, Type, hardware revision, software revision, serial number Internal bus error primer / redundant No response from IOM Configuration does not correspond to the module Hardware error Excess temperature Slot error Module requires maintenance Signal errors for each channel Signal status bit "0" = signal disturbed; "1" = signal valid Wire breakage input/output < 50 μa Short circuit input/output < 100 Ω Note: Contacts require circuitry with 1.2 kω in series and 15 kω in parallel for wire breakage/short-circuit detection. For outputs, wire breakage/short-circuit detection is only possible in the ON state. Mounting / Installation Mounting orientation horizontal or vertical (observe operating instructions) Mounting type on 35 mm DIN rail NS 35/15 (DIN EN 60715) Dimensional drawings (all dimensions in mm / inches) - subject to modifications 68 [2,68] 128,5 [5,06] 64 [2,52] 70 [2,76] 98 [3,86] 96,5 [3,8] 15254E00 Remote I/O /5

Accessories and Spare Parts Designation Figure Description Art. no. Pluggable terminal Labelling strips 02079E00 02077E00 2.5 mm 2 with lock, 16-pole, screw connector, blue, for connecting the 162702 field signals to I/O modules, for intrinsically safe field circuits Labelling: 1... 16 Attention: An additional terminal is necessary for I/O module Series 9470 and 9480. Designation: 17... 32 2.5 mm 2 with lock, 16-pole, screw connector, blue, for connecting the 162718 field signals to I/O modules, for intrinsically safe field circuits Labelling: 17... 32 2.5 mm 2 with lock, 16-pole, spring clamp connection, blue, 162695 for connecting the field signals to I/O modules, for intrinsically safe field circuits, incl. test jacks Labelling: 1... 16 Attention: An additional terminal is necessary for I/O module Series 9470 and 9480. Designation: 17... 32 2.5 mm 2 with lock, 16-pole, spring clamp connection, blue, 162716 for connecting the field signals to I/O modules, for intrinsically safe field circuits, incl. test jacks Labelling: 17... 32 "FB Addr... Mod No..." for pluggable terminal, sheet with 26 strips 162788 DIN sheet 05869E00 For label plate on I/O modules; 6 labels on each sheet; print-out using IS Wizard; packaging unit = 20 sheets 162832 Partition 09900E00 For mounting between intrinsically safe and non-intrinsically safe connections of the I/O modules, in order to adhere to the required 50 mm distance 220101 Warning sign 15196E00 "Clean modules only with a damp cloth." 162796 05872E00 We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. /6 Remote I/O