AT Advanced Wire Tracer. Users Manual

Similar documents
Circuit Breaker Finder

For detailed specifications and ordering info go to

AT-4000 Series. Advanced Wire Tracer. Users Manual

AM-500 Autoranging Mulitmeter. AM-500-EUR Digital Multimeter. Users Manual

AT Underground Cable/Pipe Locator System. Users Manual Mode d emploi Bedienungshandbuch Manuale d Uso Manual de uso Användarhandbok

CT238A. AC/DC Current Probe. User Manual. For detailed specifications and ordering info go to

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

2011 / Circuit Tracer

AMP-25 AMP-25-EUR. Mini-Clamp TRMS AC / AMP-25. ZERO 2 Sec

AC68C. Users Manual. True RMS AC/DC Clamp Multimeter. PN July Amprobe Test Tools. All rights reserved.

AT-4000 Advanced Tracer User s Manual

POWER TRACE TM TASCO, INC.

AM-520 AM-530. Users Manual. HVAC Multimeter. True-rms Electrical Contractor Multimeter

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

374/375/376 Clamp Meter

374 FC/375 FC/376 FC Clamp Meter

ACD-3300 IND ACDC-3400 IND

A Sheath Fault Locator. 99 Washington Street Melrose, MA Phone Toll Free

323/324/325 Clamp Meter

374/375/376 Clamp Meter

MICROTOOLS MICRONETBLINK KIT

ACD-14 FX ACD-14 TRMS FX

T+ and T+ PRO Electrical Tester

Supplement. Title: 30XR-A Users Supplement Issue: 1 Part Number: Issue Date: 9/06 Print Date: July 2006 Page Count: 1 Revision/Date:

netzerotools.com 374/375/376 Users Manual Clamp Meter

Electrical Multimeter

AM-540 AM-550. AM-540-EUR AM-550-EUR Digital Multimeter. Users Manual. Advanced HVAC Multimeter. Industrial Multimeter

712B. Users Manual. RTD Calibrator. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

AM-560 Advanced HVAC Multimeter. AM-570 Industrial Multimeter. User Manual EN FR ES

PHASE ROTATION METER. Operating and Instruction Manual. a n d A C C E S S O R I E S

AM-250. Digital Multimeter. Users Manual Mode d emploi Bedienungshandbuch Manual d Uso Manual de uso

200Amp AC Clamp Meter + NCV Model MA250

712C. Users Manual. RTD Calibrator

TETRIS 1000 High Impedance Active Probe. Instruction Manual

Broadband Step-Up Transformer. User Manual

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

36 AC/DC True RMS. Clamp Meter. P Read First: Safety Information

INSTRUCTION MANUAL MARTINDALE EZ150 / EZ650 SOCKET TESTER 1. INTRODUCTION. ELECTRIC Trusted by professionals

STAFF User Manual. Manual Part #

TETRIS User's Guide. High Impedance Active Probe DO177-1

Safety. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present.

TA MHz oscilloscope probe TA MHz oscilloscope probe

Digital Voltage Detector 0-999kV Operating Instructions VD1000PTM

80i-110s. AC/DC Current Probe Instructions. Introduction

SureGrip TM. XWWarning

Dynatel 2250E/2273E Advanced Cable and Fault Locator

Analog Voltage Detector 0-40kV Operating Instructions VDA040CTM

374/375/376. Calibration Manual. Clamp Meter

Operator s Manual. PP016 Passive Probe

PM55A. Automatic Precision Pocket Meter. English. Users Manual. PN July Amprobe Test Tools. All rights reserved.

902 FC. HVAC True-rms Clamp Meter

TAG5000 WIRELESS PHASER. Instruction Manual HD ELECTRIC COMPANY 1475 LAKESIDE DRIVE WAUKEGAN, ILLINOIS U.S.A.

34XR Digital Multimeter. Users Manual

User s Guide. Model MA A AC Mini Clamp-on Meter

Analog Voltage Detector 1-450kV Operating Instructions VDAO450TM. Patent No. 6,275,022

600A Clamp Meters w/tightsight Display

312, 316, 318. Clamp Meter. Users Manual

MaxLite Linear Strip ECO Series

F I S H E R R E S E A R C H L A B O R A T O R Y

MODEL 3810/2 Line Impedance Stabilization Network

SureTest Circuit Tracers Instruction Manual

Instruction Manual ET4 ELECTRICAL TESTER

Operator s Manual. PP022 Passive Probe

Current Probe Fixture Instruction Manual

PHV RO High Voltage Passive Probe. Instruction Manual

ACD-45PQ. 600A Power Quality Clamp. Users Manual Mode d emploi Bedienungshandbuch Manual d Uso Manual de uso

WARNING: Do not work around outlets while the power is on. Do not stick fingers or tools into an electrical box while the power is on.

PHV 1000-RO High Voltage Passive Probe. Instruction Manual

Grid Radar Installation Manual

Operator s Manual. PP017 and PP018 Passive Probes

Acu-Park TM. user s guide Directed Electronics, Inc. Vista, CA N9100T 09-04

Supplement. Title: 33XR-A Users Supplement Issue: 1 Part Number: Issue Date: 9/06 Print Date: July 2006 Page Count: 1 Revision/Date:

742A Series Resistance Standards

Cable I.D. Live. Primary or Secondary In or Out of the Trench TX-Former to TX-Former TX-Former to Meter Energized or Grounded.

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

MS6813. Users Manual TEST BNC MS6813 TRANSMITTER SHIELD OFF CONT TONE. Multi-Function Wire Tracer. Short Reversed Miswire Split Pairs

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

User Guide. Digital AC/DC Clamp Meter Model 38394

Pathfinder. Instruction Manual for: PF620 Circuit Tracer Kit

User s Guide. Digital AC/DC Clamp Meter Model 38394

2000 A AC TRUE RMS DIGITAL CLAMP METER WITH NON-CONTACT EF-DETECTION

TW-82 TW-82 ACCESSORIES. Operating Manual DIGITAL LINE TRACER F I S H E R R E S E A R C H L A B O R A T O R Y

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

ACD-15 Pro & ACD-15 TRMS Pro Clamp-on Multimeter Series

INSTRUCTION MANUAL INF Fax: (503)

User s Guide. 400A AC/DC Clamp Meter. Model MA220

12B/18 MultiMeter Instruction Sheet

80i-600A AC Current Probe

INSTRUCTION MANUAL E1612 EARTH TESTER 1. INTRODUCTION

Radio Remote Controls Manual K Series

15B & 17B. Multimeters. Users Manual

Broadband Current Probe Series Operation Manual

RIGOL. User s Guide. RP5600 Passive Probe. July 2010 RIGOL Technologies, Inc.

TK 100 Probe Calibrator. Instruction Manual

400Amp True RMS AC Clamp Meter + NCV

HART Mode. Users Guide. July Fluke Corporation. All rights reserved. All product names are trademarks of their respective companies.

ELECTROSURGICAL UNIT ANALYZER

1000A AC DIGITAL CLAMPMETER MODEL KM 3060

Crossover Calibrator. Owner s Manual

AMP-210 AMP-210-EUR AMP-220 AMP-220-EUR AMP-310 AMP-310-EUR AMP-320 AMP-320-EUR. 600A AC TRMS Clamp Multimeter. 600A AC / DC TRMS Clamp Multimeter

Transcription:

AT-1000 Advanced Wire Tracer Users Manual

AT-1000 Advanced Wire Tracer English Users Manual AT1000_Rev001 2008 Amprobe Test Tools. All rights reserved.

Limited Warranty and Limitation of Liability Your Amprobe product will be free from defects in material and workmanship for 2 years from the date of purchase. This warranty does not cover fuses, disposable batteries or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warranty on Amprobe s behalf. To obtain service during the warranty period, return the product with proof of purchase to an authorized Amprobe Test Tools Service Center or to an Amprobe dealer or distributor. See Repair Section for details. This warranty is your only remedy. All other warranties - whether express, implied or stautory - including implied warranties of fitness for a particular purpose or merchantability, are hereby disclaimed. Manufacturer shall not be liable for any special, indirect, incidental or consequential damages or losses, arising from any cause or theory. Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this limitation of liability may not apply to you. Repair All test tools returned for warranty or non-warranty repair or for calibration should be accompanied by the following: your name, company s name, address, telephone number, and proof of purchase. Additionally, please include a brief description of the problem or the service requested and include the test leads with the meter. Non-warranty repair or replacement charges should be remitted in the form of a check, a money order, credit card with expiration date, or a purchase order made payable to Amprobe Test Tools. In-Warranty Repairs and Replacement All Countries Please read the warranty statement and check your battery before requesting repair. During the warranty period any defective test tool can be returned to your Amprobe Test Tools distributor for an exchange for the same or like product. Please check the Where to Buy section on www.amprobe.com for a list of distributors near you. Additionally, in the United States and Canada In-Warranty repair and replacement units can also be sent to a Amprobe Test Tools Service Center (see address below). Non-Warranty Repairs and Replacement US and Canada Non-warranty repairs in the United States and Canada should be sent to a Amprobe Test Tools Service Center. Call Amprobe Test Tools or inquire at your point of purchase for current repair and replacement rates. In USA In Canada Amprobe Test Tools Amprobe Test Tools Everett, WA 98203 Mississauga, ON L4Z 1X9 Tel: 877-AMPROBE (267-7623) Tel: 905-890-7600 Non-Warranty Repairs and Replacement Europe European non-warranty units can be replaced by your Amprobe Test Tools distributor for a nominal charge. Please check the Where to Buy section on www.amprobe.com for a list of distributors near you. 2

R1000 Receiver X1000 Transmitter 3

Contents AT-1000 Advanced Wire Tracer Symbols... 5 Introduction... 5 Safety Precautions and Warnings... 5 Unpacking and inspection... 6 Component Description... 6 R1000 Receiver... 6 X1000 Transmitter... 6 Replacing Batteries: R1000 and X1000... 7 Operation... 7 Tracing Energized Wires... 7 Locating Opens... 8 Locating Shorts... 8 Fuse Replacement... 8 Specifications... 9 4

Symbols N Battery W Refer to the manual T Double insulated X Dangerous Voltage F Direct Current J Earth Ground B Alternating Current R Audible tone ; =, Conforms to relevant Australian standards. P Complies with EU directives Do not dispose of this product as unsorted municipal waste. > Underwriters Laboratories. Application around and removal from hazardous live conductors is permitted Introduction AMPROBE is dedicated to designing, manufacturing and marketing high quality, reliable instruments for the skilled professional. AMPROBE has a history of providing safe, reliable equipment to trace energized wires, circuit breakers, tracing deenergized wires, and locating opens. The AT-1000 Advanced Tracing System combines these features in one versatile tool and is effective in solving most tracing problems. The AT-1000 is a troubleshooting tool. An experienced troubleshooter will understand how the system to be traced works under normal conditions, and be familiar with the types of malfunctions that can exists. A thorough understanding of Ohms Law is helpful. It is a good idea to test the circuit for parameters such as Volts, Ohms, and Current to determine whether the circuit is shorted, semi-shorted, or open, before attempting to trace. The characteristics of these malfunctions will designate which components, and tracing method, will be most effective in locating these malfunctions. A thorough understanding of the operation and function of each of the AT-1000 components is essential. Overall, this knowledge could mean the difference between spending several minutes or several hours on a job. Pay special attention to the Safety Precautions and Warnings. Experiment under known conditions. You will gain the confidence to use it on a daily basis and solve problems which were previously unsolvable. Safety Precautions and Warnings 1. Read this manual in its entirety before proceeding with any testing. 5

2. This equipment should only be used by trained professionals who are familiar with electrical hazards. 3. Wear lineman gloves, safety glasses, and protective clothing at all times. 4. Do not attempt to replace or remove the battery in the X1000 Transmitter until X1000 is removed from the circuit and the cord set test leads are removed from the X1000 transmitter. 5. Always inspect the components and accessories for damage and proper operation BEFORE using. Replace any damaged components. 6. Before connecting the X1000 Transmitter to a circuit, verify that the voltage, at the intended point of contact, does not exceed 300VAC/DC. 7. Store the components in the case when not in use. 8. Remove the battery from the R1000 Receiver and X1000 Transmitter if the components will not be in use for a long period of time. 9. Before proceeding with any testing, confirm the X1000 is functioning correctly by switching the X1000 to the ON position. The Battery Indicator should flash. If the Battery Indicator remains OFF, replace the battery. 10. Connections to the test circuit should be made after insertion of test leads into X1000. Unpacking and inspection AT-1000 (US version) AT-1000E (Europe version) 1 x R1000 Receiver 1 x R1000 Receiver 1 x X1000 Transmitter 1 x X1000 Transmitter 1 x C2901 Cordset 2 x Test probes (in set EU-200) 1 x C2902 Cordset 2 x Crocodile clips (in set EU-200) 1 x AD-1 Adapter 2 x Test leads (in set EU-200) 1x Instruction Manual 1 x. Instruction Manual 1x Soft Carrying case 1 x Hard carrying case 2 x 9V Battery 2 x 9V Battery Component Description R1000 Receiver The R1000 contains two built-in detectors that are tuned to pick-up the 17kHz signal generated by the X1000. The detector is selected by the MODE Switch. The OPEN position selects the electrostatic (voltage potential) detector. The CURRENT position selects the electromagnetic (current) detector. The selection of detector depends on the condition of the circuit to be traced. The electromagnetic detector is set in one direction within the R1000 housing. The manner in which the receiver is held, and the direction in which the detector is pointed, will vary the amount of signal that is displayed and give the user an indication of the direction of the wire being traced. This is particularly evident when the R1000 is in the CURRENT MODE. Pointing the receiver perpendicular to the wire, so that the front label faces the direction of the wire, will yield the maximum signal displayed. 6

The R1000 is designed to display the signal strength visually with a series of four LED s, and audibly by emitting a pulsed tone. The R1000 is turned ON and OFF, as well as varying the amount of signal strength that is displayed, by the Sensitivity Range Switch (OFF, X1, X2, X3, X4, X5). The Battery LED illuminates when the R1000 is turned ON. The distance the R1000 is held from the wire carrying the signal will also vary the signal strength that is displayed. The receiver can typically detect a signal approximately 1-3 feet away from the wire carrying the signal. Always try to keep the sensitivity low enough, or high enough, to maintain a maximum of 3 LED s on the indicator so the wire that is carrying the maximum signal is easily identified. The user must vary the sensitivity to what is considered an acceptable, usable level (usually 3 LED s), while holding the receiver in the proper direction, to locate the conductor that is carrying the signal and to identify its direction. X1000 Transmitter WX Warning X1000 Do not connect to live circuits above 300VAC/DC! The X1000 Transmitter enables tracing of energized circuits up to 300VAC/DC as well as tracing deenergized lines. When connected to a closed or energized circuit that allows current to flow, the X1000 will turn on and off and cause a 17kHz current fluctuation that can be detected, by the R1000 in the CURRENT mode, along the circuit path. The signal will flow to the lowest impedance in the circuit. Usually, the signal is more evident and detected on the conductors going back to the source (transformer). To increase the signal current travelling to the source (transformer), disconnect any know loads on that circuit. When connected to an open circuit, the X1000 will inject a 17kHz voltage fluctuation that can be detected, by the R1000 in the OPEN mode, along the circuit path to the end of that circuit. Proper operation of the X1000 Transmitter is confirmed when the R1000 received indicates a pulsed signal. Replacing Batteries: R1000 and X1000 (see Fig. 1) WX Warning Do not attempt to replace or remove the battery in the X1000 Transmitter until X1000 is removed from the circuit and the cord set test leads are removed from the X1000 Transmitter. The patented battery compartment, on the back of the R1000 and X1000, allows you to replace the battery quickly and easily. Two holes on the bottom of the compartment accept the round terminals of a 9 volt battery. The compartment is designed to accept the battery in only one orientation, so if the door doesn t close, turn the battery 180 and try again. Operation WX Warning Make sure the line voltage DOES NOT EXCEED the range of the X1000: 300VAC/DC max. 1. Using either the C2901 Pigtail Cords Set for 120V receptacles (see Fig. 2), or the C2902 Alligator-Clip Banana Plug Cord Set (see Fig. 3), connect the X1000 Transmitter to the circuit 7

(see Fig. 4). When using the C2902, always connect to ground first and disconnect from ground last. 2. Switch the R1000 Receiver ON by sliding the Sensitivity Range Switch to position 3 and set the R1000 Mode Switch to CURRENT MODE. 3. Verify that the X1000 Transmitter is generating a current signal by placing the R1000 tip against one of the cord set leads. 4. Go to the panel and move the Receiver up and down, and in front of, each circuit breaker to determine which one has the strongest signal. Remember to keep the receiver perpendicular to the breakers. Reduce the R1000 sensitivity with the Sensitivity Range Switch if the signal strength goes above 4 LED s. Leave it in this position until you come across another breaker with a stronger signal. The strongest signal will determine the proper breaker. 5. If two or more breakers produce the same signal strength indication, reduce the sensitivity or pull back the R1000 slightly from the breakers until detecting the right one. Tracing Energized Wires WX Warning Make sure the line voltage does not exceed the range of the X1000 Transmitter: 300VAC/DC max. The X1000 Transmitter produces opposing signals on each output terminal. When the conductors that are connected to these terminals come within close proximity of each other, the signal strength is attenuated (see Fig. 5). This can make tracing conductors more difficult, if not impossible. In most cases you can solve this problem by using the C2902 cord set and connecting one output terminal to a different signal return path. Use something other than the return (neutral) running adjacent to the conductor you are trying to trace, like a water pipe or a ground rod. The AD-1 adapter enables access to the hot conductor in 120VAC receptacles (see Fig. 6). 1. Connect the X1000 Transmitter as in Fig. 6 and turn the unit ON. 2. Set the R1000 Mode Switch to the CURRENT MODE. 3. Switch the R1000 Receiver ON by sliding the Sensitivity Range Switch set to position 5. 4. Verify that the X1000 Transmitter is generating a current signal by placing the tip against one of the cord set leads. 5. Move the R1000 Receiver along the conductor path, perpendicular to the conductor, and adjust the Sensitivity Range as needed to maintain approximately 3-4 LED s of signal strength. 6. Proceed to trace the wire by moving the R1000 left to right over the path of the wire so that you can see the rise and fall of the signal level (see Fig. 7). The strongest signal confirms the path of the wire. If the signal drops off, the wire may have taken a turn in another direction. Before attempting to adjust the sensitivity, back track and try tracing from another angle, if possible. If the signal becomes too strong, adjust the sensitivity as necessary. 8

Locating Opens Opens are deenergized conductors that are not connected to a source or a load, and therefore do not pass current. First verify that the conductor is deenergized, using a voltmeter, then verify that it is open, with respect to ground and/or adjacent conductors, using an Ohmmeter. 1. Using the C2902 Cord Set, connect the X1000 Transmitter to the open conductor and a separate ground as shown in Fig. 8. Use the AD-1 if applicable. 2. Where possible, ground any other conductors sharing the same path as the open wire to reduce capacitive coupling, or signal bleed-off onto those conductors. 3. Switch the R1000 Receiver to the OPEN mode and turn the receiver ON by sliding the Sensitivity Range Switch and set it to position 5. 4. Verify that the X1000 Transmitter is generating a signal by placing the R1000 tip against one of the cord set leads. 5. Proceed to trace the wire by moving the R1000 left to right over the path of the wire so that you can see the rise and fall of the signal level (see Fig. 7). Adjust the Sensitivity Range Switch to display 3 LED s of signal strength. The strongest signal confirms the path of the wire. If the signal drops off, the wire may have taken a turn in another direction, or may be open at this point. Before attempting to adjust the sensitivity, back track and try tracing from another angle, if possible. Pinpoint the location of the open (where the signal drops off) by reducing the sensitivity while decreasing the distance between the R1000 and the conductor. 6. If possible, repeat the process starting from the other end of the wire to verify the location of the open. Locating Shorts 1. Using the C2902 Cord Set, connect the X1000 Transmitter to the shorted conductor and a separate ground as shown in Fig. 9. Use the AD-1 adapter if tracing a conductor connected to a receptacle. 2. Switch the R1000 Receiver to the CURRENT mode and turn the receiver ON by sliding the Sensitivity Range Switch and set it to position 5 3. Verify that the X1000 Transmitter is generating a signal by placing the R1000 tip against one of the cord set leads. 4. Proceed to trace the wire by moving the R1000 left to right over the path of the wire so that you can see the rise and fall of the signal level (see Fig. 7). Adjust the Sensitivity Range Switch to display 3 LED s of signal strength. The strongest signal confirms the path of the wire. If the signal drops off, the wire may have taken a turn in another direction, or may be shorted at this point. Before attempting to adjust the sensitivity, back track and try tracing from another angle, if possible. Pinpoint the location of the short (where the signal drops off) by reducing the sensitivity while decreasing the distance between the R1000 and the conductor. 5. If possible, repeat the process starting from the other end of the wire to verify the location of the short. 9

Fig. 1: Battery Replacement Fig. 2a: C2901 Cordset Fig. 2b: C2902 Cordset Fig. 3: EU-200 Cordset 10

Fig. 4: Locating Breakers Fig. 5: Signal Attenuation 11

Fig. 6: Tracing Conductors Fig. 7: Tracing Wires 12

Fig. 8: Tracing Opens Fig. 9: Locating Shorts 13

Fig. 10a: Back View Fig. 10b: X1000 with Front Cover Removed Fig. 10: Fuse Replacement 14

Visit www.amprobe.com for Catalog Application notes Product specifications User manuals Please Recycle