QUINT-PS/ 1AC/24DC/20

Similar documents
QUINT-PS/ 3AC/24DC/10

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

QUINT-PS AC/24DC/40

QUINT-PS/ 3AC/24DC/40

MINI-PS AC/2X15DC/1

QUINT-PS-24DC/24DC/10

MINI-PS AC/24DC/1.3

UNO-PS/1AC/24DC/150W. Primary-switched power supply unit. Data sheet. 1 Description

TRIO-PS-2G/1AC/24DC/5

QUINT-PS/1AC/24DC/10. Power supply unit. Data sheet. 1 Description

Type CP-S, CP-C & CP-A Switch mode

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

STEP-UPS/24DC/24DC/3. Uninterruptible power supply. Data sheet. 1 Description. Features

Power supply CP-E 24/2.5

Power supply CP-E 24/20.0

CP-T range Product group picture

Power supply CP-E 24/0.75

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800)

Power supply CP-E 24/2.5

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

CP-T range Benefits and advantages

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Power supply CP-T 24/20.0 Primary switch mode power supply

Power supply CP-T 24/40.0 Primary switch mode power supply

Power supply CP-T 24/10.0 Primary switch mode power supply

Power supply CP-D 24/1.3

Power supply CP-T 48/20.0 Primary switch mode power supply

Power supply CP-T 48/5.0 Primary switch mode power supply

Power supply CP-D 24/4.2 Primary switch mode power supply

CP-E range Benefits and advantages

PHOENIX CONTACT - 09/2009

Power supply CP-D 12/2.1

Primary switch mode power supplies Product group picture

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

MCR-VAC-UI-0-DC. Voltage transducer for AC voltages. INTERFACE Data sheet _en_02. 1 Description

Switching power supplies CP range, Linear power supplies CP-L range. Content

MINI MCR-SL-UI-f(-SP)

Passive Current Transducers for Sinusoidal Alternate Currents From A/0...5 A MCR-SLP-1/5-UI-0(-SW)

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

MINI MCR-SL-UI-I-LP-NC

Electronic timer CT-TGD.22

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004

Switched mode power supply for DIN rail mounting type SMP21 DC24V/10A

Switched mode power supply for DIN rail mounting type SMP23 DC24V/40A

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

PHOENIX CONTACT

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

MCR-C-UI-UI-DCI MCR 3-Way Isolation Amplifier, Configurable

Device circuit breakers Selective power distribution: branch out, individual adaptation, modular extension

PHOENIX CONTACT

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Power Supplies 3. SDN-C Compact DIN Rail Series

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

TSX Series. Modicon Manuals. Presented by: Modicon PLC. Schneider Electric Quantum Modicon Gould Gettys

Electronic timer CT-SDD.22

Three-phase monitoring relay CM-PFS

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

For Immediate Delivery call KMParts.com at (866)

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Electronic Circuit Protector ESX10-T

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Electronic Circuit Breaker with reset input ESS20-1..

Transformers, Power Supply Units and Socket Outlets

Three-phase monitoring relays

Smart Power Relay E I...

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-SDS.22

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

Type: EASY719 DA RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC. Description

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81

Installation / Monitoring Technique

Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts

RAD-IN/OUT-8D. Digital extension modules for the bidirectional wireless system. INTERFACE Data sheet _en_05. 1 Description

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Type 3RW RW40 7. Control electronics Rated values. Terminal. external DC supply (to DIN 19240) through terminals and IN Relay outputs

Power supply CP-C.1 24/10.0 Product revision M F High-performance primary switch mode power supply

Liquid level monitoring relay CM-ENS.2x

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

24 V DC, 12 W output 12 V DC, 12 W output 24 V DC, 36 W output

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23 and CM-MPS.43

Control module CP-A CM

MCR-SL-CUC Universal current transducer. Data sheet _en_05. 1 Description

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

Transcription:

Primary-switched power supply with SFB technology, 1 AC, output current 20 A INTERFACE Data sheet 103129_en_04 1 Description PHOENIX CONTACT - 02/2010 Features QUINT POWER power supply units Maximum system availability with SFB technology Compact power supply units of the new QUINT POWER generation maximize the availability of your system. With the SFB technology (Selective Fuse Breaking Technology), six times the nominal current for 12 ms, even the standard power circuit-breakers can now also be triggered reliably and quickly. Faulty current paths are switched off selectively, the fault is located and important system parts continue to operate. Comprehensive diagnostics are provided through constant monitoring of output voltage and current. This preventive function monitoring visualizes critical operating modes and reports them to the control unit before an error can occur. Quick tripping of the standard power circuit-breakers using dynamic power reserve SFB technology Reliable starting of difficult loads with static POWER BOOST power reserve Preventive function monitoring Can be used worldwide High degree of operational safety due to high MTBF > 500 000 h, long mains buffering times > 20 ms, high dielectric strength up to 300 V AC DANGER OF EXPOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. DANGER The device contains dangerous live elements and high levels of stored energy. Never carry out work when the power is turned on. Make sure you always use the latest documentation. It can be downloaded at www.phoenixcontact.net/download

2 Table of contents 1 Description...1 Features...1 2 Table of contents...2 3 Ordering data...3 4 Technical data...3 5 Structure...7 6 Block diagram...8 7 Safety and warning notes...8 8 Installation...9 9 Installation position...9 10 Mounting on DIN rails... 10 9 Slim-style installation...10 10 ow-profile installation...10 11 Connection to various systems... 11 12 Input... 11 11 Protection of the primary side...11 11 Recommended backup fuse for mains protection...11 13 Output... 12 12 Protection of the secondary side...12 14 Signaling... 12 14 Floating contact...13 14 Active signal outputs...13 14 Signal loop...13 15 Function... 14 14 Output characteristic curve...14 15 Thermal behavior...14 15 Parallel operation...15 15 Redundant operation...15 15 Increased performance...15 103129_en_04 PHOENIX CONTACT 2

3 Ordering data Description Type Order No. Pcs. / Pkt. Primary-switched power supply with SFB technology, 1 AC, output current 20 A QUINT-PS/ 1AC/24DC/20 2866776 1 Accessories Type Order No. Pcs. / Pkt. Universal wall adapter UWA 182/52 2938235 1 Interference suppressor filter for primary-switched power supply, QUINT- PS/1AC/24DC/20 Fan for QUINT-PS... power supply. The fan eliminates the positiondependent derating of the power supply. 4 Technical data ME-MAX-NEF/QUINT20A 2319919 1 QUINT-PS/FAN/4 2320076 1 Input data Input nominal voltage range AC input voltage range Short-term input voltage DC input voltage range AC frequency range DC frequency range Current consumption Inrush current limitation I 2 t 100 V AC... 240 V AC 85 V AC... 264 V AC 300 V AC 90 V DC... 350 V DC 45 Hz... 65 Hz 0 Hz Approx. 5.1 A (120 V AC) Approx. 2.3 A (230 V AC) < 20 A (typical) < 3.2 A 2 s Power failure bypass > 20 ms (120 V AC) > 20 ms (230 V AC) Typical response time < 0.5 s Protective circuitry Transient surge protection Varistor Input fuse, integrated 12 A (slow-blow, internal) Recommended backup fuse for mains protection 10 A (characteristic B) 16 A (characteristic B) Discharge current to PE < 3.5 ma Output data Nominal output voltage 24 V DC ±1% Setting range of the output voltage 18 V DC... 29.5 V DC (> 24 V constant capacity) Output current 20 A (-25 C... 70 C, U OUT = 24 V DC) 26 A (with POWER BOOST, -25 C... 40 C permanently, U OUT = 24 V DC) 120 A (with SFB technology, 12 ms) Magnetic fuse tripping max 16 A (characteristic B) max 6 A (Characteristic C) Derating From 60 C 2.5% per Kelvin Control deviation < 1 % (change in load, static 10%... 90%) < 2 % (change in load, dynamic 10%... 90%) < 0.1 % (change in input voltage ±10%) Power loss nominal load max. 40 W Maximum power dissipation idling 8 W Efficiency > 93 % (for 230 V AC and nominal values) Ascent time Residual ripple Connection in parallel < 0.5 ms < 30 mv PP (with nominal values) Yes, for redundancy and increased capacity 103129_en_04 PHOENIX CONTACT 3

Output data (Continued) Connection in series Surge protection against internal surge voltages Resistance to reverse feed active Output description Voltage Current Status display floating Output description Voltage Current Status display Yes Yes, limited to approx. 35 V DC max. 35 V DC U OUT > 0.9 x U N : High signal 18 V DC... 24 V DC 20 ma (short circuit resistant) U OUT > 0.9 x U N : "" ED green / U OUT < 0.9 x U N : Flashing "" ED Relay contact, U OUT > 0.9 x U N : Contact closed 30 V AC/DC 1 A U OUT > 0.9 x U N : "" ED green / U OUT < 0.9 x U N : Flashing "" ED POWER BOOST, active Output description Voltage Current I OUT < I N : High signal 18 V DC... 24 V DC 20 ma (short circuit resistant) Status display I OUT > I N : ED "BOOST" yellow / General data Insulation voltage input/output 4 kv AC (type test) 2 kv AC (routine test) Insulation voltage input / PE 3.5 kv AC (type test) 2 kv AC (routine test) Insulation voltage output / PE 500 V DC (routine test) Degree of protection IP20 Class of protection I, with PE connection MTBF > 500 000 h in acc. with IEC 61709 (SN 29500) Type of housing Steel sheet, zinc-plated Housing material Dimensions W / H / D (state of delivery) Dimensions W / H / D (90 turned) Weight Ambient conditions Ambient temperature (operation) Steel sheet, zinc-plated 90 mm / 130 mm / 125 mm 122 mm / 130 mm / 93 mm 1.7 kg -25 C... 70 C (> 60 C derating) Ambient temperature (storage/transport) -40 C... 85 C Max. permissible relative humidity (operation) 95 % (at 25 C, no condensation) Vibration (operation) < 15 Hz, amplitude ±2.5 mm in acc. with IEC 60068-2-6 15 Hz... 150 Hz, 2.3g, 90 min. Shock 30g in all directions in acc. with IEC 60068-2-27 Pollution degree in acc. with EN 50178 2 Climatic class 3K3 (in acc. with EN 60721) 103129_en_04 PHOENIX CONTACT 4

Standards Electrical Equipment for Machinery EN 60204 Safety transformers for power supply units IEC 61558-2-17 Electrical safety (of information technology equipment) IEC 60950/VDE 0805 (SEV) Electronic equipment for use in electrical power installations EN 50178/VDE 0160 (PEV) SEV IEC 60950 (SEV) and EN 60204 (PEV) Safe isolation DIN VDE 0100-410 DIN VDE 0106-1010 Protection against electric shock DIN 57100-410 Protection against electric shock, basic requirements for safe isolation in DIN VDE 0106-101 electrical equipment imitation of mains harmonic currents EN 61000-3-2 Device safety GS (tested safety) Network variants (undervoltage) Semi F47-0706 Certificate CB Scheme Approvals U approvals U isted U 508 U/C-U Recognized U 60950 U/C-U isted U 1604 Class I, Division 2, Groups A, B, C, D Conformance with EMC guideline 2004/108/EC and for low-voltage guideline 2006/95/EC Noise immunity according to EN 61000-6-2 Electrostatic discharge EN 61000-4-2 Housing evel 4 Contact discharge 8 kv Discharge in air 15 kv Comments Criterion B Electromagnetic HF field EN 61000-4-3 Housing evel 4 Frequency range 80 MHz... 1000 MHz (20 V/m) 1 GHz... 3 GHz (10 V/m) Field intensity Comments Criterion A Fast transients (burst) EN 61000-4-4 Input 4 kv (level 4 - asymmetrical) Output 2 kv (level 1 - asymmetrical) Signal 1 kv (level 1 - asymmetrical) Comments Criterion B Surge current loads (surge) EN 61000-4-5 Input 4 kv (inst. class 4 - asymmetrical: conductor to ground) 2 kv (inst. class 4 -symmetrical: conductor to conductor) Output Signal 2 kv (level 3 - asymmetrical: conductor to ground) 1 kv (level 1 - symmetrical: conductor to conductor) 1 kv (level 3 - asymmetrical: conductor to ground) Comments Criterion B 103129_en_04 PHOENIX CONTACT 5

Conformance with EMC guideline 2004/108/EC and for low-voltage guideline 2006/95/EC (Continued) Noise immunity according to EN 61000-6-2 Conducted interference EN 61000-4-6 Input/Output/Signal evel 3 - asymmetrical Frequency range 0.15 MHz... 80 MHz Voltage 10 V Comments Criterion A Voltage dips EN 61000-4-11 Input (Mains buffering > 20 ms (Semi F47)) Comments Criterion B Emitted interference in acc. with EN 61000-6-3 Radio interference voltage in acc. with EN 55011 Emitted radio interference in acc. with EN 55011 EN 55011 (EN 55022) Class B, area of application: Industry and residential EN 55011 (EN 55022) Class B, area of application: Industry and residential 103129_en_04 PHOENIX CONTACT 6

5 Structure 5 4 Signal DC OK?<? N 9 1 AC input 2 DC output 3 POWER BOOST switching output, active 4 switching output active 5 output, floating 6 Potentiometer 18 V DC... 29.5 V DC 7 "" ED 8 "BOOST" ED 9 Universal DIN rail adapter UTA 107/30 3 QUINT POWER Boost Input AC 100-240 V 18-29,5 V 1 2 Output DC 24V 20 A - - - 6 7 8 [mm 2 ] AWG [Nm] solid stranded Torque Input 0.2-6 0.2-4 18-10 0.5-0.6 Output 0.2-6 0.2-4 12-10 0.5-0.6 Signal 0.2-6 0.2-4 18-10 0.5-0.6 Input data Input nominal voltage range 100 V AC... 240 V AC AC input voltage range 85 V AC... 264 V AC Short-term input voltage 300 V AC DC input voltage range 90 V DC... 350 V DC AC frequency range 45 Hz... 65 Hz DC frequency range 0 Hz Input fuse, integrated 12 A (slow-blow, internal) Recommended backup fuse for mains protection 10 A (characteristic B) 16 A (characteristic B) Type of connection Screw connection Stripping length 7 mm Output data Nominal output voltage 24 V DC ±1% Setting range of the output voltage Output current Type of connection Stripping length 18 V DC... 29.5 V DC (> 24 V constant capacity) 20 A (-25 C... 70 C, U OUT = 24 V DC) 26 A (with POWER BOOST, -25 C... 40 C permanently, U OUT = 24 V DC) 120 A (with SFB technology, 12 ms) Pluggable screw connection 7 mm 103129_en_04 PHOENIX CONTACT 7

6 Block diagram () N (-) active PFC PE I<I N 13 14 7 Safety and warning notes DANGER OF EXPOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. DANGER The device contains dangerous live elements and high levels of stored energy. Never carry out work when the power is turned on. WARNING Before startup please ensure: The mains connection has been carried out by a competent person and protection against electric shock is guaranteed! The device can be disconnected outside the power supply unit in accordance with the regulations as in EN 60950 (e.g. through primary side line protection)! The ground conductor is connected! All feed lines are sufficiently protected and dimensioned! All output lines are dimensioned according to the maximum output current of the device or separately protected! Sufficient convection is guaranteed! CAUTION The power supply units are built-in devices. The device may only be installed and put into operation by qualified personnel. The corresponding national regulations must be observed. 103129_en_04 PHOENIX CONTACT 8

DC OK Ι< Ι N QUINT-PS/ 1AC/24DC/20 8 Installation Signal DC OK?<? N ATTENTION In order to ensure sufficient convection, we recommend a minimum vertical distance of 5 cm to the other modules. A lateral distance of 5 mm, and in the case of active components, that of 15 mm is necessary for proper functioning of the module. Depending on the ambient temperature and the load of the module, the housing can become very hot! QUINT POWER Input AC 100-240 V Output DC 24 V 20 A - - - Boost 18-29,5 V The power supply unit can be snapped onto all DIN rails in acc. with EN 60715. They must be mounted horizontally (connecting terminal blocks top and bottom). 9 Installation position 5 90 5 122 115 50 Signal Boost 230 QUINT POWER 18-29,5 V 130 Input AC 100-240 V Output DC 24V 20 A - - - Slim-style installation: Installation depth 125 mm ( DIN rail) (state at delivery) ow-profile installation: Installation depth 90 mm ( DIN rail) 103129_en_04 PHOENIX CONTACT 9

10 Mounting on DIN rails A B Slim-style installation Assembly: Position the module with the DIN rail guide on the upper edge of the DIN rail, and snap it in with a downward motion. Removing: Pull the snap lever open with the aid of a screwdriver and slide the module out at the lower edge of the DIN rail. A B ow-profile installation ow-profile installation can be achieved by mounting the device at right-angles to the DIN rail. Mount the DIN rail adapter (UTA 107/30) as described in the figure. No additional mounting material is required. Fixing screws: Torx T10 (torque 0.8 Nm... 0.9 Nm). 103129_en_04 PHOENIX CONTACT 10

11 Connection to various systems TN-S TN-C TT it N PE PEN PEN 1 2(N) 1 2 3 N PE 1 2 3 PEN 1 2 3 N 1 2 3 The connection for 100 V AC... 240 V AC is established using the, N, and P screw connections. The device can be connected to 1-phase AC networks or to two of the phase conductors of three-phase systems (TN, TT or IT systems in accordance with VDE 0100-300/IEC 60364-3) with nominal voltages of 100 V AC... 240 V AC. The device also continues to work on short-term input voltages > 300 V AC. For operation on two of the phase conductors of a three-phase system, an isolating facility for all poles must be provided. 12 Input CAUTION If an internal fuse is triggered, there is most probably a malfunction in the device. In this case, the device must be inspected in the factory! QUINT POWER Input AC 100-240 V Signal DC OK Output DC 24V 20 A?<? N Boost 18-29,5 V - - - Protection of the primary side The device must be installed in acc. with the regulations as in EN 60950. It must be possible to disconnect the device using a suitable isolating facility outside the power supply. The primary side line protection, for example, is suitable. For device protection, there is an internal fuse. Additional device protection is not necessary. Recommended backup fuse for mains protection Power circuit breaker 10 A or 16 A, characteristic B (or identical function). In DC applications, a suitable fuse must be wired in upstream. 103129_en_04 PHOENIX CONTACT 11

13 Output CAUTION Make sure that all output lines are dimensioned according to the maximum output current or are separately protected. The cables on the secondary side must have sufficiently large cross sections in order to keep the voltage drops on the lines as low as possible. QUINT POWER Signal DC OK?<? N Boost 18-29,5 V The connection is established using screw connections on the screw connection of the DC output: 24 V DC: "" and " "; switching output active: "" and " "; output floating: "13" and "14"; POWER BOOST switching output active: "I < I N " and " ". At the time of delivery, the output voltage is 24 V DC. The output voltage can be set on the potentiometer. Input AC 100-240 V Output DC 24V 20 A - - - Protection of the secondary side The device is electronically protected against short circuit and idling. In the event of a malfunction, the output voltage is limited to 35 V DC. 14 Signaling An active signal output, a floating signal contact and an active signal output POWER BOOST are available for function monitoring. In addition, the ED and the BOOST ED can be used to evaluate the function of the power supply directly at the installation location (see output characteristic curve). I < I N I > I N U OUT < 0.9 x U N "" ED ON ON Flashing "BOOST" ED OFF ON ON Active switching output ON ON OFF Floating output Closed Closed Open Active POWER BOOST switching output ON OFF OFF Meaning Normal operation of the power supply (U OUT >21.5V) POWER BOOST operation, e.g. to start loads Overload mode, e.g. consumer short circuit or overload 103129_en_04 PHOENIX CONTACT 12

Output 24 V DC - - - Floating contact The floating signal contact opens and indicates that the set output voltage has undershot by more than 10%. Signals and ohmic loads of up to maximum 30 V and currents of maximum 1 A (or maximum 60 V with maximum 0.5 A) can be switched. For heavily inductive loads such as a relay, a suitable protection circuit (e.g. damping diode) is necessary. max. 30 V AC/DC 1A Active signal outputs 18... 24 VDC 20 ma Output 24 VDC - - - The 18... 24 V DC signal is applied between the "" and the " " connection terminal blocks or between "I < I N " and " " and can carry up to 20 ma. By switching from "active high" to "low", the signal output signalizes when the output voltage is fallen short of by more than 10 %. The signal is decoupled from the power output. This ensures that an external supply does not enter from devices connected in parallel. The POWER BOOST signal output I < I N signalizes that the nominal current is exceeded. The power supply unit is then in the POWER BOOST mode. Using this preventive function monitoring, critical operating statuses can be governed at an early stage before it results in a voltage dip. The 18... 24 V DC signal can be directly connected to a logic input for evaluation. 1 2 Output 24 V DC - - - Output 24 V DC - - - Signal loop Monitoring two devices: Use the active signal output of device 1 and loop in the floating signal output of device 2. In the event of malfunctioning, a common alarm is output. Any number of devices can be looped in. This signal combination saves wiring costs and logic inputs. 103129_en_04 PHOENIX CONTACT 13

15 Function Output characteristic curve The power supply unit works with the static power reserve POWER BOOST as shown in the U/I characteristic curve in the figure. At ambient temperatures T amb <40 C, I BOOST is available continuously. At higher temperatures, it's available for a few minutes. In the event of a secondary-side short circuit or overload, the output current is limited to I BOOST. Thereby, the module does not switch off, but rather supplies a continuous output current. The secondary voltage is reduced here until the short circuit is eliminated. The U/I characteristic curve with the power reserve POWER BOOST ensures that both high inrush currents of capacitive loads as well as consumers with DC/DC converters in the primary circuit can be supplied. In order to trip standard power circuit breakers magnetically and very quickly, power supply units must supply a multiple of their nominal current for a short period. As can be seen from the characteristic curve, when I < I N, I > I N and U < 0.9 x U N. The relevant signaling can be found in the table "Signaling". U N = 24 V I N = 20 A I BOOST = 26 A SFB technology = 120 A P N = 480 W P BOOST = 625 W U [V] OUT U N I<I N I N I>I N U<0,9xU N I BOOST I OUT [A] Thermal behavior Output current [A] I BOOST I N 0-25 20 40 60 Ambient temperature [ C] With an ambient temperature of up to 40 C, the device supplies the continuous output current of I BOOST. The device can supply a nominal output current of I N with ambient temperatures of up to 60 C. In the case of ambient temperatures above 60 C, the output current must be reduced by 2.5% per Kelvin increase in temperature. The device does not switch off at ambient temperatures of 70 C or thermal overload. The output capacity is reduced as far as necessary to provide device protection. After it has cooled down, the output capacity is increased again. 103129_en_04 PHOENIX CONTACT 14

Parallel operation Devices of the same type can be connected in parallel to enable both redundancy and an increase in efficiency. On default upon delivery, a further adjustment is not needed. If the output voltage is adjusted, a uniform distribution of power is guaranteed by setting all parallel operated power supply units to exactly the same output voltage. To ensure symmetrical current distribution we recommend that all cable connections from the power supply unit to the busbar are the same length and have the same cross-section! Depending on the system, for parallel connection of more than two power supply units a protective circuit should be installed at each individual device output (e.g. decoupling diode, DC fuse or power circuit breaker). This prevents high return currents in the event of a secondary device fault. Redundant operation I N I N Σ =I N Redundant circuits are suitable for the supply of systems which make especially high requirements on the operational safety. If a fault occurs in the primary circuit of the first power supply unit, the second device automatically takes over the entire power supply, without interruption, and vice versa. For this reason, the power supply units to be connected in parallel are dimensioned in such a way that the total current requirement of all consumers can be completely covered by one power supply unit. 100% redundancy makes external decoupling diodes necessary (QUINT-DIODE/40, Order No. 2938963)! I N I N Increased performance For n parallel connected devices, the output current can be increased to n x I N. Parallel connection to increase efficiency is used for the expansion of existing systems. It is advisable to use parallel connection if the power supply unit does not cover the current requirement of the most powerful consumer. Otherwise the consumers should be spread among individual devices independent of one another. A maximum of five devices can be connected in parallel! Σ =2xI N 103129_en_04 PHOENIX CONTACT GmbH & Co. KG 32823 Blomberg Germany Phone: 49-(0) 5235-3-00 15 PHOENIX CONTACT P.O.Box 4100 Harrisburg PA 17111-0100 USA Phone: 717-944-1300 www.phoenixcontact.com