Micropulse BTL-SF filling level sensor

Similar documents
Temposonics. Magnetostrictive Linear Position Sensors. GB-M / GB-T SSI Data Sheet

BML-S1F_-A/Q _-M _-_0-KA Magnetic Linear Encoder System. User's Guide. Magnetic Linear Encoder System BML-S1F_-A/Q _-M _-_0-KA

Level sensor Magnetostrictive, high-resolution measuring principle For sanitary applications, model FLM-H

BTL-5- -M -J-DEXC-KL20

Temposonics. Magnetostrictive Linear Position Sensors. GB-M / GB-T Analog Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. ET Analog Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. GB Analog Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. ET Start/Stop Data Sheet. High operating temperature Compact sensor housing ATEX certified

Temposonics. Magnetostrictive Linear Position Sensors. EP / EL Analog Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. EH Analog Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. TH SSI Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. ER Analog Data Sheet

Micropulse position measuring Micropulse

Pressure transmitter For sanitary applications Model SA-11

Temposonics. E-Series Model ER. Magnetostrictive, Absolute, Non-contact Linear-Position Sensors. Analog and Start/Stop Outputs.

Temposonics. Magnetostrictive Linear Position Sensors. EP2 Analog Data Sheet

NOVOTURN Multiturn Sensor non-contacting. Series RSM-2800

Temposonics. Magnetostrictive Linear Position Sensors. EP / EL Analog Data Sheet

P R o D u c T I n F o R m at I o n. TDR Level Sensor LFP. The clean solution

Type F-20-3A Sanitary Pressure Transmitter NEMA 4X with Integral Junction Box

Operating Instructions for Microwave Level Switch. Model: LNM

NOVOHALL Rotary Sensor non-contacting. Series RSC-2800

Distance Sensors BOD 26K.... with optional Master-Slave-Mode

Temposonics. Magnetostrictive Linear Position Sensors. ER SSI Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. ER Analog Data Sheet

NOVOSTRICTIVE Transducer up to 4250 mm touchless. Series TH1

Temposonics. Magnetostrictive Linear Position Sensors. EH IO-Link Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. EP2 Analog Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. EP2 SSI Data Sheet

T10FS. Data Sheet. Torque Flange. Special features. Installation example T10FS. B en

POSICHRON position sensor in a stainless steel pressure case. Voltage: V, 3 wire Current: ma, 3 wire

Temposonics. Magnetostrictive Linear Position Sensors. ER IO-Link Data Sheet

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Temposonics. Magnetostrictive Linear Position Sensors. EP2 CANopen Data Sheet

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

Temposonics. Magnetostrictive Linear Position Sensors. EP2 IO-Link Data Sheet

T10F. Data Sheet. Torque Flange. Special features. Installation example T10F. B en

Technical Information Smartec CLD18

POSICHRON position sensor in stick design. Protection class. Voltage: V, 3 wire Current: ma, 3 wire

LVDT. Inductive Position Transducer. SLX-series. designed for pharmaceutical, medical and food industry. content: Key-Features:

Temposonics. Magnetostrictive Linear Position Sensors. ER Start / Stop Data Sheet

Flush pressure transmitter For viscous and solids-containing media Model S-11

RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC

RoHS. High shaft load capacity. Shock / vibration resistant

XXXX e. X d.. X X X a

High-quality pressure transmitter For general industrial applications Model S-10

T22. Torque transducer. Special features. Data sheet

BTL5-_-M_-J-DEXC-TA12 Micropulse Linear Position Transducer

Temposonics. Magnetostrictive Linear Position Sensors. EP / EL Start / Stop Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. EP / EL IO-Link Data Sheet

NOVOHALL Rotary Sensor non-contacting. Series RSC2800 digital SSI, SPI, Incremental

NOVOHALL Rotary Sensor non-contacting. Series RSX-7900

Temposonics. Magnetostrictive Linear Position Sensors. MH-Series Flexible MH Data Sheet

OPTITEMP TT 20 Technical Datasheet

Technical Information Smartec CLD18

Technical Information Memosens CLS82D

Absolute Encoders Multiturn

DTM.OCS.S/N - Modbus Level Transmitter

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

Temposonics. Magnetostrictive Linear Position Sensors. ER IO-Link Data Sheet

XXXX e. X d.. X X X a

omnigrad T - TSM 480, TR 480. Technical Information. RTD Temperature Sensor Hygienic design TSM 480 with electronics programmable via PC

Temposonics. Magnetostrictive Linear Position Sensors. RT4 SSI Data Sheet. Redundant SSI output High temperature rod IP68 ingress protection

Temposonics. Magnetostrictive Linear Position Sensors. ER SSI Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. TH SSI Data Sheet

Submersible pressure sensor For oils and fuels Model LF-1

Absolute Encoders Multiturn

NOVOHALL Rotary Sensor non-contacting. Series RSC2800 analog

PHOTOELECTRIC SENSORS. Online data sheet

NOVOHALL Rotary Sensor touchless transmissive. Series RFX-6900

ATM.ECO - Analog Pressure Transmitter with Temperature Compensation

T40FM. Data Sheet. Torque flange. Special features. Overall concept. B en

Float switch For industrial applications, plastic version Model RLS-2000

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

T40B. Torque Flange. Special features. Data sheet. Overall concept

EMSPA LINEAR MAGNETOSTRICTIVE TRANSDUCER WITH ANALOG OUTPUT. Magnetostrictive transducer. Main characteristics. Ordering code EMSPA 1000 S 10S 10 P A

T40FH. Torque flange. Special features. Data sheet

Absolute Encoders Singleturn

Features. Picture. Specifications

T22. Data Sheet. Torque transducer. Special features. Installation example with two bellows couplings. B en

Passive Current Transducers for Sinusoidal Alternate Currents From A/0...5 A MCR-SLP-1/5-UI-0(-SW)

Liquiphant T FTL20H. Technical Information

MHPS MHPS. Modular pressure transmitter. Technical documentation. Table of content. Characteristics - applications - technical data

OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5)

Inductive Standard Displacement Transducers

ENCODER. Analog Multiturn Encoder. Serie 8.M5861. Key-Features:

Standard Sendix 5000 / 5020 (shaft / hollow shaft) Push-Pull / RS422 / Open collector. Robust performance. Many variants

LINEAR POTENTIOMETER. LMI12-SL / LMI12-SE Series. Key-Features:

BNI IOL E023 BNI IOL E023 BNI IOL E023 BNI IOL E023. User s Guide

Temposonics. R-Series SSI. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Measuring length mm. Perfect data processing I 7 I

Resistance thermometer Model TR31, miniature design

Magnetic absolute encoder GEL 2035 Serial interface (SSI), 24 Bit

Features. Picture. Specifications. Pressure Transmitter 4-20mA 2-wire MPG Type: MPGxxxxxxxx for level measurement Order No.: see Table 1 / Page 4

Absolute Encoders - Singleturn

Temposonics. R-Series SSI. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Stroke length mm. Perfect data processing 0.

Magnetic-Inductive flow Meter fmi

Picture. Digital output signal (pressure and temperature) RS-485 Modbus RTU, 9600 bps Protocol details see Data Sheet SW

Phone: Fax: Web: -

11 Product group. Inductive transducers in cylindrical metal housings A WA F A WA X A WD X A WU X

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Transcription:

Micropulse BTL-SF filling level sensor Maximum precision for foodstuffs and hygiene MICROPULSE

Micropulse transducers BTL-SF fi lling level sensor Continuously precise measurement in µ area delivers excellent fi lling results 100 % stainless steel ensures top hygiene standards and long service life International certifi cate guarantees maximum quality Maximum precision for food hygiene internationally certified The BTL-SF fi lling level sensor ensures continuously precise measurement in applications that demand extreme hygiene. Made from corrosion-free stainless steel with excellent surface quality and rounded edges, the sensor meets the highest international hygiene standards and fulfi lls all strict requirements of the food industry. Take advantage of the best quality directly from the manufacturer. Other benefi ts Neutral for all liquids Compensates for foam, thus delivering reliable fi lling level values Adjustment-free installation Easy to clean in installed state (CIP Clean in Place) For process temperatures up to 130 C (SIP Sterilization in Place) Standardized interfaces ensure fl exible installation Internationally certifi ed quality guarantees global marketing and sales of your system Rising and falling signal available In the USA, 3-A Sanitary Standards Inc. formulates and monitors hygiene guidelines for devices used in the manufacture and packaging of milk and foodstuffs. Our products with this designation are 3-Aapproved. The EHEDG (European Hygienic Engineering & Design) designation is the European standard for hygiene in the food industry. Our products with this logo conform to EHEDG standards. The FDA (Food and Drug Administration) oversees the US food and medicaments industry and certifi es devices, materials, as well as systems and machines, from these areas. With such a product designation, you are also able to receive FDA approval for your system. The ECOLAB designation stands for consistency against aggressive cleaning agents. Devices with ECOLAB markings fulfi ll their standards.

100 % stainless steel Micropulse transducers BTL-SF fi lling level sensor IP69K FDA- and EHEDGconformal Series BTL5 SF rod Transducer interface Analog Customer-side interface Analog Ordering code BTL5-...-M -SF-F Polarity reversal protected Yes Overvoltage protection 36 V Dielectric strength 500 V (GND to housing) Degree of protection as per IEC 60529 IP 67/IP 69K (fl ange and tube) Housing material Stainless 1.4404 Flange and tube material 1.4404 Connection Sensor with lead Attachment 1.5" Tri Clamp i.a.w. SSI 3A standard 74-03 Pressure rating 300 bar (depends on fl oat) EMC tests: RF Emission EN 55016-2-3 Group 1, Class A and B Static Electricity (ESD) IEC 61000-4-2/EN 61000-4-2 Severity 3 Electromagnetic Fields (RFI) IEC 61000-4-3/EN 61000-4-3 Severity 3 Rapid Transients (BURST) IEC 61000-4-4/EN 61000-4-4 Severity 3 Conducted interference IEC 61000-4-6/EN 61000-4-6 Severity 3 induced by high frequency fi elds Withstand voltage (Surge) IEC 61000-4-5/EN 61000-4-5 Severity 2 Magnetic fi elds IEC 61000-4-8/EN 61000-4-8 Severity 4 Standard nominal stroke (mm) 0025, 0050, 0075, 0100, 0125, 0150, 0175, 0200, 0225, 0250, 0275, 0300, 0325, 0350, 0375, 0400, 0425, 0450, 0475, 0500, 0550, 0600, 0650, 0700, 0750, 0800, 0850, 0900, 0950, 1000, 1100, 1200, 1300, 1400, 1500, 1600, 1700, 1800, 1900, 2000, 2250, 2500 or in 5 mm increments on request Scope of delivery: Transducer Brief instructions Please order separately: Tri Clamp Page 6 Float Page 6 O-ring Page 6 Welded hexagon nipple Page 6 Attention! Prior to design, installation and startup, please read the instructions in the user guide! n www.balluff.com 3

Micropulse transducers Micropulse magnetostrictive measurement The industry-standard filling level sensor works with the triedand-tested Micropulse technology, an absolute and contact-free magnetostrictive measurement, which for years has been associated with top reliability. In addition, it also has analog interfaces and can, through this widespread standard signal, be used simply in process automation. Analog signal A signal that can accept continuous, (almost) infinitely variable, values between a minimum and a maximum is described as an analog signal. The output signal of the BTL-SF filling level sensor is analog and directly proportional to the position of the float on the sensor tube. Features Reasonably priced system solution Can be used from each controller Cable break monitoring through 4...20 ma signal Current signal, interference-free signal transfer High resolution and repeatability Rising and falling signal available Variants Current (4...20 ma or 0...20 ma) Voltage (0...10 V or 10...0 V) Series Output signal Transducer interface Customer-side interface Ordering code Output voltage Output current Load current Ripple max. Load resistance System resolution Hysteresis Repeatability Sampling rate Max. non-linearity Temperature coefficient Operating voltage Current draw Polarity reversal protected Overvoltage protection Dielectric strength Operating temperature Process temperature 130 C for one hour Wiring configuration Color Output signals YE GY PK GN Operating voltage BU BN WH Shield connected to housing Scope of delivery: Transducer Brief instructions Please order separately: Tri Clamp Page 6 Float Page 6 O-ring Page 6 Welded hexagon nipple Page 6 Teflon cable LIF5Y-FC-5Y (7x0.25mm²): Temperature resistant up to 200 C Good resistance against chemicals and oil 4

Extremely precise Micropulse transducers Analog interfaces BTL5 SF rod BTL5 SF rod BTL5 SF rod Analog Analog Analog A E C Analog Analog Analog BTL5-A11-M -SF- BTL5-E1_-M -SF- BTL5-C1_-M -SF- 0...10 V and 10...0 V 4...20 ma or 20...4 ma 0...20 ma or 20...0 ma max. 5 ma 5 mv 500 ohm (500 ohm) 500 ohm (500 ohm) 0.1 mv 0.2 µa 0.2 µa 4 µm 4 µm 4 µm System resolution/min. 2 µm System resolution/min. 2 µm System resolution/min. 2 µm f STANDARD = 500 Hz f STANDARD = 500 Hz f STANDARD = 500 Hz ±100 µm to 500 mm nominal stroke ±0.02 % 500... max. nominal stroke ±100 µm to 500 mm nominal stroke ±0.02 % 500... max. nominal stroke ±100 µm to 500 mm nominal stroke ±0.02 % 500... max. nominal stroke 40 ppm/k for nominal stroke 500 mm, float at center of measuring range 40 ppm/k for nominal stroke 500 mm, float at center of measuring range 40 ppm/k for nominal stroke 500 mm, float at center of measuring range 20...28 V DC 20...28 V DC 20...28 V DC 150 ma 150 ma 150 ma Yes Yes Yes 36 V 36 V 36 V 500 V DC (GND to housing) 500 V DC (GND to housing) 500 V DC (GND to housing) 40...+85 C 40...+85 C 40...+85 C 40...+100 C 40...+100 C 40...+100 C BTL5-A11... BTL5-E10... BTL5-E17... BTL5-C10... BTL5-C17... 4...20 ma 20...4 ma 0...20 ma 20...0 ma 0 V Output 0 V Output 0 V Output 0 V Output 0 V Output 10...0 V 0...10 V GND GND GND GND GND +24 V DC +24 V DC +24 V DC +24 V DC +24 V DC Ordering example: BTL5-_1_-M -SF- Interface Output Signal Standard Nominal stroke [mm] Radial connection A E C 1 rising and falling for A 0 rising (for C and E) 7 falling (for C and E) 0025, 0050, 0075, 0100, 0125, 0150, 0175, 0200, 0225, 0250, 0275, 0300, 0325, 0350, 0375, 0400, 0425, 0450, 0475, 0500, 0550, 0600, 0650, 0700, 0750, 0800, 0850, 0900, 0950, 1000, 1100, 1200, 1300, 1400, 1500, 1600, 1700, 1800, 1900, 2000, 2250, 2500 or in 5 mm increments on request F02 Teflon cable 2 m F05 Teflon cable 5 m F10 Teflon cable 10 m F15 Teflon cable 15 m F20 Teflon cable 20 m n www.balluff.com 5

Micropulse transducers Accessory Description Float Tri Clamp (DIN 32676) O-ring Welded hexagon nipple for series BTL5 SF rod BTL5 SF rod BTL5 SF rod BTL5 SF rod Ordering code BTL-S-3112-4Z BAM MC-XA-006-D38,1-5 BAM SE-XA-002-D38,1-5 BAM-AD-XA-003-D38,1-5 Material Stainless 1.4404 USA ASTM 316 (1.4401) Platinum catalyzed silicone Weight approx. 30 g Operating temperature/ 40...+130 C Storage temperature Insertion depth in water approx. 31 mm Pressure rating (static) 24 bar Part no. W. 1.4435 BN2 (Fe 0.5 %) i.a.w. EB 10088 IP69K 120 C 130 C Process temperature: maximum permissible temperature of the rod under the flange (with media contact). Certain production processes require, for example sterilization at 120 C 130 C for 0.5 1 hour. Included in scope of delivery for float: Float Instructions Splint (spring pin 2 30) "Junction float" on request. Attention! Approvals only issued through use of these components. Prior to design, installation and startup, please read the instructions in the user guide! 6

Balluff Competent partnership For greater efficiency On-site competent partnership technological diversity, optimal solutions, individual service With over 50 years of sensors experience, Balluff is a globally leading sensor specialist with well-engineered displacement sensing technology and its own line of connectivity products for every area of factory automation. Balluff stands for comprehensive systems from a single source, continuous innovation, the most modern technology, highest quality and greatest reliability. And even more. For distinctive customer orientation, custom-tailored solutions, fast worldwide service and outstanding application assistance. In short: for reliable, expert partnership. Headquartered in Germany and with 54 representatives and subsidiaries, Balluff is tightly networked internationally. So there is always a Balluff expert near you. Balluff high quality high-performance technology for increased productivity Extremely precise distance measurement Balluff distance measurement offers efficient individual solutions. Precisely for your needs. The most diverse operating principles. For travel distances from 1 to 48 m and resolutions from 1 to 100 µm. From position detection to distance measurement. Totally flexible. And use Balluff's mature linear displacement sensing technology to simply increase your added value. More information at balluff.de/btl7 Safety with stainless steel Our sensors and systems in stainless steel guarantee safety and hygiene. And perform even better. Find out more about the proven Balluff stainless steel program for food, drinks, cosmetics and pharmaceutical industries, as well as medical devices. For more information on the topic of stainless steel, please see the "Guaranteed Safety and Hygiene" catalogue or visit balluff.de/edelstahl Refined network Learn about comprehensive intelligently networked system technology. With components that are optimally matched to the controllers. More about high-performance communication which ensures the full potential of your system. See the "Industrial Networking" catalogue for more Balluff products used for connecting to the controls or visit balluff.de/networking n www.balluff.com 7

Object Detection Linear Position Sensing Industrial Identification Industrial Networking and Connectivity Mechanical Accessories Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a.d.f. Germany Phone +49 7158 173-0 Fax +49 7158 5010 balluff@balluff.com www.balluff.com No. 870670 E Edition 0907; Subject to changes.