Product description High efficiency ~ 40 lm/w Colour temperature 3,850 K High colour rendering index (CRI > 80) Small colour tolerance MacAdam 4 Homogeneous, non-glare and wide-area lighting Dimmable neutral white light High specific light distribution of 9,000 lm/m² Extremely flat design (< 3 mm) White diffuse surfaces Connection with cable or plug contact Technical data Beam characteristic 120 Ambient temperature ta 0... +40 C Typ. tp point 40 C Risk group (EN 62471:2008) 0 È Standards, page 3 Colour temperatures and tolerances, Page 6 module LUREON REP 10 LUREON REP 31 49 99 89 tp The position of the tp point is on the backside of the module in the middle of the lable. 3 Order data Type Article number Colour Type of Packaging, temperature 3 connection carton Weight per pc. LUREON REP 10-40-DL 28000052 3,850 K Cable 10 pc(s). 0.055 kg LUREON REP 10-40-DC 28000053 3,850 K Plug contact 10 pc(s). 0.055 kg Spezific technical data Type Photometric code Typ. luminous flux 1 Forward current 12 Supply voltage 1 Typ. power1 Colour rendering index CRI 13 module LUREON REP 10-40 840/4x7 68 lm 285 ma 6.0 V 1.70 W > 80 840/4x7 83 lm 350 ma 6.1 V 2.14 W > 80 All data for tp = 25 C. 1 Tolerance range for optical and electrical data ±15 %. 2 For the valid current range, please refer to the diagram on page 4. Exceeding the max. operating current leads to an overload of the module. This may result in a significant reduction in lifetime or even in destruction. 3 Colour temperature and tolerances according to CIE 1931 www.tridonic.com 1
LED control gear matrix module LUREON (serial configuration) Type LED control gear with dimming function LCAI 015/0350 A020 one4all LCCI 016/0350 Q010 LCCI 016/0350 B020 LED control gear without dimming function LCI 015/0350 E020 LCI 005/0350 E020 LCCI 016/0700 Q010 Art. no. 86458899 86459213 86459210 24166312 24166311 86459215 Assignable LED control gear Type Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. LUREON REP 10-40 280000xx 2 7 1 7 1 7 4 7 2 3 1 3 www.tridonic.com 2
Standards EN 62471 Photometric code Key for photometric code, e. g. 830 / 559 1 st digit 2 nd + 3 rd digit 4 th digit 5 th digit 6 th digit Lumen maintanance after 25% Code CRI McAdams after of the lifetime (max.6000h) Colour temperature in McAdams 25% of the Code Remaining lumen 7 67 76 Kelvin x 100 initial lifetime 7 70 % 8 77 86 (max.6000h) 8 80 % 9 87 90 9 90 % Installation instructions Avoid mechanical stress from impact and pressure forces on the module otherwise the glass may break, the surface film may delaminate or the internal structure may be damaged. Always wear appropriate gloves when installing or removing the elements to avoid damaging or contaminating the contacts or the module. Hold the module on its side when installing or removing and avoid direct contact with the metal contacts. The modules are designed for indoor use. Keep the module away from water and areas of high humidity. Make sure condensation cannot form on the module. tp point, ambient temperatur and lifetime The temperature at the tp point is critical for the light output and lifetime of the module. Check for compliance with the permitted tp temperature under operating conditions in the thermally stable state. Bear in mind the worst-case conditions for the particular application. Ambient temperatur ta from 0 C to +40 C Storage conditions Store the modules in a dry environment at temperatures between 0 and 60 C under ESD conditions. Cooling type The module is self-cooling. Expected Lifetime1 tp temperature I F Luminous flux Lifetime 80 % 5.500 h 25 C 285 ma 70 % 10.000 h 50% 22.000 h 80% 3.000 h 25 C 350 ma 70% 5.500 h 50% 12.000 h Electrical supply/choice of control gear modules from Tridonic are not protected against overvoltages, overcurrents, overloads or short-circuit currents. Safe and reliable operation of the module is therefore possible only with a LED control gear that complies with the relevant specifications. If a LED control gear is used that does not come from Tridonic it must offer the following protective functions: Short-circuit detection Overload detection Overtemperature shutdown Operate modules on constant-current LED control gears. The module may be destroyed if it is operated on a constant-voltage LED control gear. Reversing the polarity may damage the module. Type of connection solder contact The modules are suitable only for manual soldering (max. 260 C, 2 seconds). An automatic soldering process may destroy the module because of the heat applied. The module will be delivered with pre-assembled cable. Wiring Cable: AWG 22; length 200 mm Colour white black Function + Type of connection plug contact Plug type: AVX 9159002 Cable: AWG 22; length 200 mm Colour white black Function + www.tridonic.com 3
Relative forward voltage and relative luminous flux 1,04 1,40 rel. voltage [a.u.] Relative colour temperature rel. colour temperature [a.u.] Optical properties The optical design ensures optimum homogenity for the light distribution. Light distribution rel. Light intensity Iv/Iv, max 1,02 0,98 0,96 0,94 0,92 100 80 rel. voltage at ta = 25 C 1,02 1,01 0,99 0,98 0,97 0,96 0,95 60-60 -50-40 -30-20 rel. colour temperature at ta = 25 C -10 0 40 70 20 80 0-100 -80-60 -40-20 0 20 40 60 80 100 90 10 20 30 40 50 60 rel. luminous flux [a.u.] 1,20 0,80 0,60 0,40 0,20 0,00 rel. luminous flux at ta = 25 C www.tridonic.com 4
Coordinates and tolerances according to CIE 1964 The specified colour coordinates are measured by a current impulse of 285 ma and a duration of 5 minutes. The ambient temperature of the measurement is ta = 25 C. The measurement tolerance of the colour coordinates is ± 0.01. x0 y0 Centre 0.3970 0.3920 0,4100 0,4050 0,4000 0,3950 0,3900 0,3850 0,3800 0,3750 0,3800 0,3850 0,3900 0,3950 MacAdam Ellipse: 4SDCM 1 Colour temperature and tolerances according to CIE 1931 0,4000 0,4050 0,4100 0,4150 rel. intensity [a.u.] 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.0 400 450 500 550 600 650 700 750 wavelength [nm] www.tridonic.com 5