FLEXDC INSTALLATION GUIDE

Similar documents
Mounting Clips. FLEXMNT.SIL.INT, FLEXMNT.SIL.EXT12 Dimming Options. (pg. 7) 0-10 Volts. Channels. Connectors LUMEN OUTPUT.

SLOT INSTALLATION GUIDE Indoor IP20

Drywall with Plaster and Paint. Lamp: The average LED Life is 50,000 hours. per Foot. per Watt. (2x2.5WDC) (2x5WDC) (2x6WDC)

Lamp: The average LED Life is 50,000 hours. per Foot 2WDC (2.5WDC) per Watt. per Foot 5WDC Lumen values are based on the 3000K LED test.

Drywall with Plaster and Paint. 6" - 400" (15.2cm cm) Lamp: The average LED Life is 50,000 hours. per Foot. per Watt. per Foot (2.

TruLine TruQuad.5A 24VDC - PLASTER-IN LED SYSTEM

DAZZLE ACCENT LIGHTING SYSTEM

LED Neon Light Round

PRODUCT DATA SHEET. ColorBright Color Changing. RGB 300 Series. Year Warranty.

Project: Client: Part #: NEON -P FLT HB 24VDC WHT lc con cab. Date: Qty:

Project: Client: Part #: NEON -P ARC 24VDC WHT lc con cab. Date: Qty: Length CST Custom Length cuttable every 2.81 Operating Voltage (ov)

ACCESSORIES. Channels Mounting Clips Connectors Strain Relief LUMEN OUTPUT 1800K 2350K 2750K K K 1 PERFORMANCE CRI + + +

diode led DAZZLE ACCENT LIGHTING SYSTEM POWERED BY INCEPTION LIGHTING TECHNOLOGY IP65 24VDC SPECIFICATIONS CHANNEL COVER AVAILABLE IN:

LED Neon Light Flat RGBW

Installation Instructions for DIY or Completed Light Channel.6 Millwork

LED Neon Light Arch RGB

PrimaLine 1.5 XT Wet Location LED Tape Light

MOUTNING OPTIONS. Mounting Clips. Double Sided Tape Channels 2400K 2700K 3000K 3500K 4100K 6000K PERFORMANCE

ACCESSORIES. Channels Optic Arts Channel (pg. 3-6) LUMEN OUTPUT. 1800k PERFORMANCE CRI = 24 VDC 73 = 7.3w XX = Custom Length

Installation Instructions For Reveal

INSTALLATION LED DRIVER. Top view. LED Module. Barrel. Block side. 2 black or white wires. 2 red wires. Gland. + side. Cover. Mounting Screws.

The only lighting product that is designed, approved, and patented to replace the cross members in a suspended grid ceiling system.

DURAFLEX NEON TM SIDE Flex IP66 OUTDOOR

QUANTUM 2 CIRCLE 24 Installation Instructions

Installation Instructions for TruLine 1.6A 24VDC. Section One: Basic Configuration Options

Installation Instructions for DIY or Completed 45 Degree Light Channel

QUANTUM 2 TRAPEZOID 2509 Installation Instructions

Installing Fixture Using Remote Power Supply

MOONDISH RPD06/R2 SUSPENDED, SURFACE

DURAFLEX NEON TM TOP Flex IP66 OUTDOOR

FLEX DC VARIABLE WHITE

3% VOLTAGE DROP. Installation Instructions for 400 Watt 24 Volt DC RGB DMX LED Power Supply SAVE THESE INSTRUCTIONS!

LX Series Part-Sensing Light Screen

Aluminum Clad Wood Window 1/2 Reinforced Field Mulling and Stacking Supplement

Quantum 2 SQUARE 0605

Underwater LED Lighting Installation Instructions

Underwater LED Lighting Installation Instructions

ALS450T. our most versatile SERIES

Installation Instructions for Zip Suspension Downlight with Remote Power and 4" Square or Round Canopy

Sky FactoryTM. Classic w/ EcoPlus Electrical Instructions (Fixture Only) Installation Instructions includes:

SeriesTWO RGB Fluorescent Fixtures. Installation and Instruction Manual

DURAFLEX NEON TM SIDE VIEW IP66 OUTDOOR

12VDC SMD5050 RGBW 4in1 LED flexible strip, 300LED per 5meter per roll

Installation Guide. brighter. lighter.

Quantum 2 SQUARE 0808K

SURFACE CLIP MOUNT. 1 Insert lens into channel, measure, and cut to length. Remove lens cover from channel. surface. Attach lens cover and end caps

#4 Phillips Driver Bit 1/8, 4mm, 5.5mm & 8mm (5/16 ) Allen Wrench. Safety Glasses

Installation Instructions For Reveal Light Channel

Lattice Application Overview Updated

UNIT No FRAMELESS PIVOT SHOWER DOOR

COOLEDGE TILE GEN2 INTERIOR-TUNABLE WHITE INSTALLATION MANUAL

ES255-LED SERIES DIRECT, INDIRECT, DIRECT/INDIRECT HIGH EFFIECIENCY LED - SUSPENDED, WALL, SURFACE, RECESSED

ROUND LIGHTPLANE 2 RLP2 WALL MOUNT. STANDARD SIZES 2" Diameter Wall-Mounted Luminaires Configurable in individual sections from 1ft. - 8ft.

PRELIMINARY. S050W-054C1400-L03-UN-D2 50W Programmable Driver. Electrical Specifications. Protections. Environmental Specifications.

Sienna Pendant Drop Lens PENDANT

with Lamp Install the Housing with Adjustable Bars Installation Instructions for LED E3_-L_DN 1.1 ½ to ¾ ¾ or thicker

300C6 CONTINUOUS HINGE SEMI-FRAMELESS DOOR KIT

CROWNE POINTE RPD16 SUSPENDED, WALL, SURFACE

BSS610 GENERAL INFORMATION - FIXTURE HOUSING

Baymaster HL LED Luminaire High Bay for Hazardous Locations

INSTALLATION INSTRUCTIONS. Deluxe Continuous Hinge Inline Door & Panel Shower Enclosure QCI5230

Waterproof RGB Pixel Control LED Neon Part Number: PLN-RGB-20

PRODUCT SPECIFICATIONS

675 Quick N Stall Neo Angle Framed Hinge Shower Enclosure

Emily Pendant PENDANT

LL-105-R LED Dimmer & 0-10V Bridge Setup Guide

FRAMED PANEL / DOOR / PANEL CONTINUOUS HINGE SHOWER ENCLOSURE INSTALLATION INSTRUCTIONS

FEATURES MECHANICAL SPECIFICATIONS ELECTRICAL SPECIFICATIONS PRODUCT INTERFACE

Model Location Dimming Location Output CRI * C.C.T. Reflector Shell Color Suspension Options Q2LP

The following instructions will guide you through the installation of your new vinyl railing.

D2 Dimmer User s Manual Rev 0.3

HOLLY HUNT LIGHTING. STUDIO H EDGE CHANDELIER Installation Instructions

R12V 12-VOLT STANDARD OUTPUT 12V INDOOR STANDARD OUTPUT LED RIBBON 12V WET LOCATION STANDARD OUTPUT LED RIBBON WESTGATE MFG

MODA MINI GRAZE INTERIOR GLOWDIM SPECIFICATION. Client: Project Name: MODA Contact: Quantity: PO#: Type: Notes:

Kayla Pendant Flush Lens PENDANT

GO FIGURE RPD07 SUSPENDED, SURFACE

738 SERIES PIVOT SHOWER DOOR

Andrena Pendant PENDANT

Baymaster LED Luminaire High Bay for Hazardous Locations

THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS.

Parts List. Description. Installation Instructions

MODA MINI COVE INTERIOR DYNAMIC WHITE

SINKS AND LAVATORIES. Steps to completion: These items are essential for installing all sinks:

diode led 24VDC COMMERCIAL GRADE SPECIFICATION SHEET RECEIVE A UL LISTED DRIVER WHEN ORDERING THE LO-PRO JUNCTION BOX & DRIVER COMBO ON PAGE 2.

All Terrain Flares 2014 Chevy Silverado

Installation Instructions

Connecting the Channel A

MODA MINI COVE INTERIOR DYNAMIC WHITE

ROOF MOUNT. *Class A* Fire Rated INSTALLATION MANUAL

Prel-Lam LC-LTI Liquid Crystal Laminated Glass

Storing, Handling, and Cleaning dekō Markerboards Storing Markerboards. Handling. Cleaning

INSTALLATION INSTRUCTIONS Xenix Incandescent Series XN12, XN24, XN36, XN48

Installation Instructions

Sealed Interface Control: EC20300

LUMINAIRE LLED9100-F OUR MOST VERSATILE SERIES

IP66 IP65. Trail Wires Female Connectors. STEP 1: Measure area where system is to be installed.

CX-100. Installation Instructions. PIR Occupancy Sensor SPECIFICATIONS

8 Channel, DMX to 0 10 volt, Decoder board

LED SERIES SPECTACOLOUR FLOOD RGB SPECTACOLOUR FLOOD RGB

Aluminum Clad Wood Window Field Mulling and Stacking Instructions

Transcription:

Please read entire guide prior to starting installation. NOTES 1. IP40 and lower tape must be installed indoors only. 2. Installation must be carried out by a licensed electrician & executed in accordance with local codes. 3. The installing contractor assumes all liability for the safety and code compliance of the installation. SINGLE COLOR INDOOR +24VDC RGBA/W INDOOR +24VDC -CH 1, RED -CH2, GREEN WIRE COLOR RED WIRE COLOR WHITE RED GREEN RGB INDOOR +24VDC -CH 1, RED -CH2, GREEN -CH 3, BLUE WIRE COLOR WHITE RED GREEN BLUE 4. Optic Arts is not liable for any damages caused by improper -CH 3, BLUE BLUE INSTALLATION WITH CHANNEL wiring, driver overloading, driver under-loading, power surges, poor system design or layout, negligence or other conditions. -CH4, WHITE OR AMBER YELLOW 1. 2. 1 1.1 Channel is not waterproof. If installing channel in a location where it will be in direct contact with water (rain, sprinkler spray, etc.) weep holes should be drilled to allow water to drain out of channel. Drill holes every 12 and in such a way that water in the channel will run out through them. Holes should be approximately 1/16 to 1/8 in diameter. When considering weep hole locations, be aware that light may leak from weep holes and try to position them out of normal viewing angles. 2.1 Channel without mounting clips: drill screws directly through the channel and into the mounting surface. 1 screw every 2 feet if recommended. 3. 3.1 Channel with mounting clips: mount 1 clip per foot by screwing down each clip to mounting surface. 3.2 Snap channel into clips. Join channels end to end if aligning multiple pieces for longer runs. 3.3 Before mounting tape, clean inside of aluminum channel 1 using a lint free cloth with rubbing alcohol and allow channel to dry. 1 of 11

INSTALLATION WITH CHANNEL 4. 5. 4.1 Apply a bead of 3M 1099 adhesive to channel. *3M 1099 Adhesive supplied by others FLEX.ZIP 3 5.1 Install FLEX.ZIP mounting clip 3 away from end of mounting tape. 5.2 Unroll FLEXDC strip and place on top of silicone bead pressing down firmly to set in place. 5.3 Remove excess silicone from channel with a lint free cloth. *FLEXDC must be clamped or weighted down while curing to ensure proper bond to channel. **Installations in cold locations may require the use of heaters to allow for proper curing. ***Allow silicone to cure for 24 hours. 6. 6.1 Snap or slide lens into channel. 6.2 Install channel endcaps. 2 of 11

INSTALLATION WITH CHANNEL 7. 7.1 Install zip tie around lead wire. Cut off excess zip tie. 3 of 11

ELECTRICAL INSTALLATION MLV ELECTRONIC - NON-DIM MLV ELECTRONIC 120 VAC 120-277 VAC PURE DC MLV ELECTRONIC W/0-10V MODULE 120 VAC WIRING 24V + 24V - PURE DC ELECTRONIC 0-10 + 0-10 - 277 VAC WIRING + 120 VAC 120-277 VAC FIELD INSTALLED IN LOW VOLTAGE WIRING COMPARTMENT 0-10 V CONTROLLER - Install DIM-010V Module in low voltage wiring compartment. - Max number of 25 modules on one dimmer. Consult dimmer datasheet for maximum device limitation of a specific controller. PURE DC 277 VAC + GRAY WIRE TO 0-10V CONTROLLER - VIOLET WIRE TO 0-10V CONTROLLER + BLACK WIRE TO DC - OUTPUT OF RED WIRE TO DC + OUTPUT OF DIM-010V 0-10V MODULE BLUE WIRE TO LED - YELLOW WIRE TO LED + 1.1 Confirm that all power is off prior to starting installation. Landing hot wires to the FLEXDC wire leads can damage the strip and will not be covered under warranty. 1.2 Wire FLEXDC strip to Optic Arts supplied driver. Use of any other driver must be approved by Optic Arts prior to use in order to maintain warranty. 1.3 EMCOD MLV drivers must be loaded between 80% and 100%. 1.4 PURE DC drivers and electronic drivers have no minimum load. 1.5 Ensure that the proper wire gauge is used in order to minimize voltage drop. 1.6 Make certain that the polarity is correct prior to energizing system. Reverse polarity wiring can damage the FLEXDC strip and will not be covered under warranty. 4 of 11

ELECTRICAL INSTALLATION ELECTRONIC W/DMX MODULE 120-277 VAC ELECTRONIC DMX MODULE DMX in + DMX in - DMX in shield LED+ CH1 - CH2 - CH3 - CH4 - FROM DMX CONTROLLER (BY OTHERS) OUT TO NEXT MODULE (32 MAX) W/A B G R LED+ 5 of 11

ELECTRICAL INSTALLATION 1% 2-WIRE: 2-WIRE CONTROL FORWARD PHASE 1% 2-WIRE: 2-WIRE CONTROL FORWARD PHASE DIMMER WITH DIMMER WITHOUT 24V DC + 24V DC + 24V DC - 24V DC - 1% 2-WIRE 1% 2-WIRE DIMMED LINE (BLACK) -WIRE DIMMER/MODULE/PANEL LINE/HOT DIMMED LINE (BLACK) FORWARD PHASE DIMMER WITHOUT LINE/HOT (WHITE) (WHITE) 6 of 11

ELECTRICAL INSTALLATION 1%: 3-WIRE/ECOSYSTEM 3-WIRE 1%: 3-WIRE/ECOSYSTEM ECOSYSTEM 24V DC + 24V DC + 24V DC - TO ECOSYSTEM DIGITAL LINK 24V DC - E1 (Purple) E1 (Purple) E2 (Purple) 1% 3-WIRE E2 (Purple) 1% 3-WIRE SWITCHED LINE (BLACK) DIMMED LINE (ORANGE) 3-WIRE DIMMER/MODULE/PANEL LINE/HOT DIMMED LINE (ORANGE) LINE/HOT (WHITE) 7 of 11

ELECTRICAL INSTALLATION PREMIER: 3-WIRE/ECOSYSTEM 3-WIRE PREMIER: 3-WIRE/ECOSYSTEM ECOSYSTEM 24V + 24V + 24V - 24V - PREMIER PREMIER (WITH ECOSYSTEM CONTROL & SOFT-ON FADE TO BLACK TECHNOLOGY) LINE/HOT 3-WIRE DIMMER/MODULE/PANEL SWITCHED LINE/HOT (L) DIMMED HOT (DH) TO ECOSYSTEM DIGITAL LINK E1 (Purple) E2 (Purple) 120-277 VAC 8 of 11

REMOTE DISTANCE CHART NOTES: 1. Calculated using 4 amp draw (96 Watts at 24VDC). 2. Calculation includes 6 1 factory lead connected to home run. 3. Home run can be increased if factory lead length is decreased. JUNCTION BOX FLEX DC HOME RUN FACTORY LEAD 6, 1 HOME RUN DISTANCE MINIMUM GAUGE VOLTS % DROP 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 1 16 AWG 14 AWG 14 AWG 12 AWG 12 AWG 10 AWG 10 AWG 10 AWG 10 AWG 6 AWG 6 AWG 6 AWG 6 AWG 23.44 23.38 23.43 23.34 23.38 23.32 23.42 23.38 23.34 23.30 23.42 23.40 23.37 23.35 23.32 23.30 23.43 22.41 23.40 23.38 2.38% 2.62% 2.41% 2.78% 2.60% 2.87% 2.45% 2.61% 2.78% 2.95% 2.43% 2.54% 2.64% 2.75% 2.85% 2.96% 2.40% 2.47% 2.53% 2.60% 9 of 11

120-277 VAC ELECTRONIC W/DMX MODULE ELECTRONIC PART GG100E-24-UNV-DMX DESCRIPTION 96W 120-277VAC ELECTRONIC WITH eldoled DMX DIMMING MODULE DIMENSIONS 96W H 3.00 ; W 11.46 ; D 1.30 DMX MODULE H 1.97 ; W 6.02 ; D 0.91 *Must be installed in UL box (by others) DIMMING PERFORMANCE DMX MODULE ELECTRONIC - DMX MODULE Dims to 0.1% on most DMX systems DMX in + DMX in - DMX in shield LED+ CH1 - CH2 - CH3 - CH4 - FROM DMX CONTROLLER (BY OTHERS) OUT TO NEXT MODULE (32 MAX) W/A B G R LED+ 10 of 11

24V + Y B W/R* Cool GG100-24-UNV Warm * Wire is either white or red, depending on specific product. 0-10 + 0-10 - 120-277 VAC ELECTRONIC W/VintageDim MODULE 0-10 V CONTROLLER PART DESCRIPTION GG100E-24-UNV-DMX 96W 120-277VAC ELECTRONIC WITH eldoled DMX DIMMING MODULE FIELD INSTALLED IN LOW VOLTAGE WIRING COMPARTMENT - Install VintageDim Module in low voltage wiring compartment. - Consult dimmer datasheet for maximum device limitation of a specific controller. DIMENSIONS ELECTRONIC H 3.00 ; W 11.46 ; D 1.30 GRAY WIRE TO 0-10V CONTROLLER - VintageDim MODULE H 1.56 ; W 1.56 ; D 0.78 VIOLET WIRE TO 0-10V CONTROLLER + BLUE WIRE TO DC - OUTPUT OF RED WIRE TO DC + OUTPUT OF VintageDim MODULE YELLOW WIRE TO LED (WARM) - WHITE WIRE TO LED (COOL) - BLACK WIRE TO LED + BLACK WIRE TO LED + DIMMING PERFORMANCE ELECTRONIC - VintageDim Dims below 1% on most 0-10V dimmers * Cap off one + wire unless using two separate strips 11 of 11