OpDAT Universalkabel 1x4 OM4 - biegeunempfindlich, Klasse. Principle diagram

Similar documents
Data sheet OpDAT breakout cable 24x1 OM4 - bend insensitive

Data sheet OpDAT connection cable 2x1 OS2 - bend insensitive

Data sheet MC GC1200 pro22 Cat.7A S/FTP 4P LSHF-FR, class Dca s2 d2

Data sheet MC GC1200 pro22 Cat.7A S/FTP 2x4P LSHF-FR 1640 ft

Data sheet MC GC1000 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft

Data sheet. Connection line M12 plug straight - M12 jack straight drag chain suitable, 8-pole, X-coded 2.0 m. Illustrations

Data sheet Patch cord Cat.6 A AWG m yellow

Outdoor, CCTV or CCTV, Fig 8 Armored.

Ø560*336mm 4.25 kg 2100 ± 105m

Data sheet Connection line M12 jack straight - RJ45 plug straight 4-pole, D-coded 2.0 m

Outdoor, Fig 8 Armored, Multi Tube

GUXW. Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor, Steel Wire Armor (SWA) A/I-VQ(ZN)HBH Full Rodent Protection v5.

Data sheet C6 A RJ45 field plug pro

Ø 1250 * 688 mm 93 kg ± 105m

HES HACILAR ELEKTRİK SANAYİ VE TİC.A.Ş.

Data sheet E-DAT Industry RJ45 plug black Cat.6 Class E A

Data sheet C6 A RJ45 field plug pro 360

Data sheet C6 A RJ45 field plug pro 360

GAAG. Multi Loose Tube Cables Outdoor - ADSS A-DQ(ZN)2Y(T) v4.0. Ordering Information. Applications. Features & Benefits

Data sheet C6 A RJ45 field plug pro 360

GORN. Central Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection, 1000N Permanent Load v6.0. Ordering Information

Single-Armored Cables, Fibers

Data sheet E-DAT Industry RJ45 field plug insert Cat.6 Class E A

Data sheet E-DAT modul 2 port AP Cat.6 A, pearl white

Data sheet C6 A modul K 180 jack - Keystone style

Dax DX-S10121 (12F Sin ngle Mode Armoured Fiber Cable -Uni-Tube Design) Introduction:

ALTOS Lite Gel-Free, Single-Jacket, Single-Armored Cables, Fibers

Data sheet E-DAT Industry RJ45 field plug black Cat.6 Class E A

Data sheet. C5 RJ45 field plug pro 2P 360 PROFINET. Illustrations P/N 130E405042PE EAN Product specification. Page 1/

Data sheet C5 RJ45 field plug pro 2P PROFINET

Data sheet. E-DAT modul 3 port AP Cat.6A, pure white. Illustrations P/N E EAN Product specification. Page 1/

Ship Hybrid Cable DL 58 5 x UC1500 SS22 2x SM BendBright XS G.657.A2 6x MM MaxCap-BB-OM4

Data sheet C6 A modul K 90 jack - keystone style

OPENETICS. P/N E-DAT Industry RJ45 field plug insert Cat.6A. Specialist Manufacturer Voice Data Security.

features and benefits

Data sheet Cable connector class F A

Data sheet. E-DAT modul Cat.6A 8(8) jack, T568B. Illustrations P/N I-B1 EAN Product specification. Page 1/

Standard Monotube SAFE

Fibre Optic Indoor/Outdoor Cable

One Enterprise. One Infrastructure. One Partner. Optical Fiber Loss Testing. Optical loss testing in the field is not as simple as it seems.

COPPER + LWL RAW CABLES

LSSS-OF FOR. Zero Water Peak Single-Mode Optical Fiber. (Reference: ITU-T G.652.D) Prepared by Eun Kyung Min Engineer Passive Solution Team

Fiber Optic Outside Plant Cables (4-144 Fibers)

Cores layed up around conductive filler with aramid rope in the center Rubber, special compound, mechanical properties acc.

ADSS Fiber Optic Cable. DESCRIPTION core, Single-mode/Multi-mode. Version: V2.0

Data sheet. M12 field plug X-coded, straight. Illustrations P/N MNF881A EAN Product specification. Page 1/

Data sheet. M12 Jack X-coded IP67, field assembly. Illustrations P/N MMF881A315 EAN Product specification. Page 1/

Optical Systems Contents

Industrial Automation

Outside Plant All Dielectric

How Bend Insensitive Multimode Fiber is Affecting Installation and Testing of Enterprise and Data Center Cabling

TECHNICAL DATA SHEET FOR Single Mode Optical Fibre Cable Duct Application

SPECIFICATION. FOR SINGLE-MODE OPTICAL FIBER (FutureGuide -SR15E)

K20 & L120 LSZH Armoured F/FTP Cat6 Cables

OptoLup TM POF cable Data Sheet. Overview. COMOSS OptoLup TM Cable is a type of APF, All. for the transmitting. compliant POF cables.

TECHNICAL DATASHEET FOR LOOSE TUBE OPTICAL FIBER CABLE. Air Blown Micro LC Cable

Type QG-G50-2C- M-BU

Article number: Sheath marking ACE - TKF LTC ADSS 24x SM G.657.A1 (2x12) A-DQ(ZN)2Y {Batch} {Year} {Length}

TECHNICAL DATA SHEET FOR Single Mode Optical Fibre Cable Direct Burial Application

FiberHome Fiber Products

Optical Fiber Cable. MODEL:GYTA53 PE Jacket. optic.com. For detailed inquiry please contact our sales team at:

ekсkoм TECHNICAL DATA SHEET FOR Duct/Aerial Application kabeli.eu (SM 24 Fibers) Technical literature for Optical Fiber Cable

SPECIFICATION. Optical Fiber Cable

NETWORK CONNECTIVITY SYSTEMS

FTTH Fiber Optical Cable

Optical Fiber Jelly. PBT loose tube. PE shealth. Aramid Yarn SINGLE MODE OPTICAL FIBER ITU-T REC. G.652D

Industrial Ethernet OPT cable manufactured for Petrol Forecourt Applications.

ETK Kablo SPECIFICATION. FOR SINGLE-MODE OPTICAL FIBER (FutureGuide -LWP)

Exhibit A Construction Project Manual and Drawings

kv: medium voltage reeling cable with fibreoptics

Datasheet Outside Plant Cable

Information technology. Generic cabling systems, General requirements

TECHNICAL DATA SHEET FOR Uni-tube Single Mode Optical Fibre Cable ARMORED. (SM 2~24 Fibers)

Content HYBRID AND SPECIAL CABLES G 1. for the application on marine engines... page. : especially for use in rail vehicles. ❿! Applications...

White Paper: The Ins and Outs of Testing Bend Insensitive Multimode Fiber (BIMMF): The Need for Encircled Flux

TECHNICAL ARTICLE: DESIGN BRIEF FOR INDUSTRIAL FIBRE OPTICAL NETWORKS

GIGABIT ETHERNET. e-ready Building Next Generation IT infrastructures. The Cabling Partnership. Mike Gilmore Managing Director, e-ready Building

RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814

Nufern 980 nm Select Cut-Off Single-Mode Fiber

Bending the Truth - Get the straight story about Corning ClearCurve multimode fibers

Measurement Considerations for Corning ClearCurve LBL and ZBL Optical Fiber

For information transmission at dry and moist production sites, in and under plaster, outdoors for fixed installation.

Data, Network and Bus Technology

SPECIFICATION FOR SINGLE-MODE OPTICAL FIBRES

RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814

Z EE E E Z E Z Z Z Z Z

Connection technology for wireless communication systems

There are lots of problems or challenges with fiber, Attenuation, Reflections, Dispersion and so on. So here we will look at these problems.

JFOC-BSG2D MODEL:JFOC-BSG2D. optic.com. For detailed inquiry please contact our sales team at:

Medium Voltage Power Cables

OFS AllWave non-dispersion shifted single-mode optical fiber

CXP/CFP 100G MPO Cable Assembly

Fiber Optic Principles. Oct-09 1

The Quality Connection. Cable and Systems for Rolling Stock Business Unit Rolling Stock

GYFY-24FO Total Dry. Item Material Description PE outer sheath HDPE Nominal thickness:1.8mm

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

HO7RN-F 450/750V BS EN Highly Flexible Rubber Cable

Electric cables. Cranes

ZHONGTIAN TECHNOLOGIES CO., LTD ZHONGTIAN TECHNOLOGIES FIBER OPTICS CO., LTD

ORTRONICS FIBER TRUNK CABLE SYSTEM BY LEGRAND. designed to be better.

Transcription:

Page 1/9 Illustrations Principle diagram See enlarged drawings at the end of document Product specification installation cable U-DQ(ZN)BH universal fiber optic cable for indoors/outdoors with central or stranded loose tube bend insensitive fiber UV-resistant, metal-free, longitudinally waterproof, tensile strength and rodent repellent cable jacket: LSHF cable structure: filled loose tubes cable diameter for central loose tube 7.5 mm with 2 to 12 fibers per loose tube cable diameter for central loose tube 8.0 mm with 24 fibers per loose tube cable diameter with stranded loose tube 11.0 mm strain relief: longitudinally waterproof wrapping, glass roving elements stranded loose tubes: loose tubes grouped around a glass fiber reinforced plastic stick with a dia. of 2.5 mm for laying in ducts or directly in the ground in a suitable layer of sand applicable standards: EN 50173-1, ISO 11801 2nd edition, IEC 60794-1, EN 187000 fire behaviour: Class (classification acc. to EN 13501-6) Variant: Number of OM5 fibers 1x4, 1x8, 1x12, 1x24, 4x12 Number of OM4 fibers 1x4, 1x8, 1x12, 1x24, 4x12 Number of OM3 fibers 1x4, 1x8, 1x12, 1x24, 4x12 Number of OM2 fibers 1x4, 1x8, 1x12

Page 2/9 Illustrations General Data Fields of application Design Structured building cabling, Office Data center Installation cables Transmission technology Fiber optic Color violett Color coding fiber/ wire(s) see table Mode type of the fiber Multimode Fiber class Number of cables/ cores OM4 (ISO/IEC 11801/EN 50173 & IEC 60793-2-10/EN 60793-2-10 A1.a.3) 1 Number of fibres each cable/ wire 4 Fiber construction 50/125 µm Weight 55.00 kg/km Connections/interfaces Connector technology interface 1 Free line end Connector technology interface 2 Free line end Cable sheath diameter (min. - max.) Cable sheath diameter 7.50 mm Cable sheath diameter 0.276 in. Mechanical characteristics strain relief longitudinally waterproof wrapping, glass roving elements Maximum installation load (max.) 1500 N Maximum installation load 60 mm Maximum installation load 2.362 in. Impact resistance 20 J Crush (compressive strength) 2000 N Fire load 1100 MJ/km

Page 3/9 Materials and material properties Material - Cable jacket LSHF Bend insensitivity Tensile strength Rodent protection Flame retardancy Halogen free UV-resistance Longitudinal water tightness pass, no water on free end Laser-optimized Environmental conditions Temperature (min. - max.) Temperature - Storage C -40-60 C Temperature - Storage F -40-140 F Temperature - Operating C -30-70 C Temperature - Operating F -22-158 F Temperature - Installation C -15-40 C Temperature - Installation F 5-104 F Approvals RoHS compliant The product meets the following standards Generic cabling systems General requirements ISO/IEC 11801 DIN EN 50173-1 Optical fibers: Product specifications Sectional specification for category A1 multimode fibres ISO/IEC 60793-2-10 (A1a.3) Optical fibers: Generic specification Cross reference table for optical cable test procedures ISO/IEC 60794-1-2 Test on gases evolved during combustion of materials from cables Determination of the halogen acid gas content IEC 60754-1 Determination of acidity (by measuring the ph value) and conductivity IEC 60754-2

Page 4/9 The product meets the following standards Tests on electric and optical fibre cables under fire conditions Test for vertical flame propagation for a single insulated ISO/IEC 60332-1-2 wire or cable Measurement of smoke density of cables burning ISO/IEC 61034-2 Common test methods for cables under fire conditions Fire behaviour - class Standard colours for insulation for low-frequency cables & wires ITU-T standard Klasse (Klassifizierung nach EN 13501-6) IEC 60304 G.651.1 Classifications ETIM 5.0 EC000034 Packing details Type of packaging 0 meter Packaging dimension (W x H x D) 0.00 x 0.00 x 0.00 mm

Page 5/9 Illustrations Principle diagram

Page 6/9 Fiber color coding Fiber color code 1 2 3 4 red green blue yellow

Page 7/9 OpDAT fiber OM4 BR 150XXX7 General Data Transmission technology Fiber optic Mode type of the fiber Multimode Fiber class OM4 (ISO/IEC 11801/EN 50173 & IEC 60793-2-10/EN 60793-2-10 A1.a.3) 50/125 µm Fiber construction Transmission characteristics Transmission rate up to 10 GBit IEEE 802.3an Transmission rate up to 100 GBit IEEE 802.3ba Reach Reach 1000BASE LX 550 m Reach 1000BASE SX 1100 m Overfilled (OFL) modal bandwidth at 850 nm (min.) 3500 MHz * km Overfilled (OFL) modal bandwidth at 1300 nm (min.) 500 MHz * km Effective modal bandwidth (EMB) at 850 nm (min.) 4700 MHz * km Connections/interfaces Connector technology interface 1 Free line end Connector technology interface 2 Free line end Fiber core diameter 50 ± 2 µm Core-/ Fiber cladding diameter 125.0 ± 1.0 µm Primary coating diameter - colored 250 ± 15 µm Primary coating diameter - uncolored 242 ± 5 µm Optical characteristics Attenuation of the fiber Attenuation of the fiber in the cable at 850 nm Attenuation of the fiber in the cable at 1300 nm max. 3.5 db/km max. 0.8 db/km Maximum value of cable attenuation at 850 nm 3.0 db/km Maximum value of cable attenuation at 1300 nm 1.0 db/km

Page 8/9 OpDAT fiber OM4 BR 150XXX7 Mechanical characteristics Proof stress level min. 0.7 ( 1 %) GPa Typische durchschnittliche Abziehkraft 1.7 N Strip force (peak) 1.3 <= Fpeak.strip <= 8.9 N Fiber cladding non-circularity max. 0.7 % Core non-circularity max. 5 % Core (MDF)-cladding concentricity error max. 1 µm Primary coating concentricity error max. 5 % Primary coating-cladding concentricity error max. 6 Inhomogeneity of OTDR measurement report at 1310 nm und 1550 nm Group refractive index Gruppen-Brechungsindex bei 850 nm max. 0.1 db/km Gruppen-Brechungsindex bei 1300 nm Numerical aperture 1.482 1.477 0.200 ± 0.015 Materials and material properties Bend insensitivity Approvals RoHS compliant The product meets the following standards Generic cabling systems General requirements Data centers ISO/IEC 11801 cat. OM4 TIA/EIA 568-C ISO/IEC 24764 Optical fibers: Measuring methods and test procedures Fibre geometry ISO/IEC 60793-1-20 Coating geometry ISO/IEC 60793-1-21 Length measurement ISO/IEC 60793-1-22 Fibre proof test ISO/IEC 60793-1-30 Coating strippability ISO/IEC 60793-1-32 Attenuation ISO/IEC 60793-1-40 Bandbreite ISO/IEC 60793-1-41 Numerical aperture ISO/IEC 60793-1-43 Gruppenlaufzeitdifferenz ISO/IEC 60793-1-49

Page 9/9 OpDAT fiber OM4 BR 150XXX7 The product meets the following standards Optical fibers: Product specifications Sectional specification for category A1 multimode fibres ISO/IEC 60793-2-10 (A1a.3) ITU-T standard G.651.1 TIA/ANSI-492 AAAD Packing details Powered by TCPDF (www.tcpdf.org) Type of packaging 0 Packaging dimension (W x H x D) 0.00 x 0.00 x 0.00 mm