Measurement solutions for single-mode fibers

Similar documents
Power Measurment. Hand-held Design Brings Peak Performance to the Field. Introduction. Features

LASER DIODE SOURCE FIBER OPTIC (SINGLE OR MULTI-WAVELENGTH)

LASER DIODE SOURCE FIBER OPTIC (SINGLE OR MULTI-WAVELENGTH)

MADE FOR THE TRADE! XL fibertools Series

Agilent 81662A DFB Laser Agilent 81663A DFB Laser Agilent Fabry-Perot Lasers

OPTICAL MEASURING INSTRUMENTS MS9020D GPIB OPTICAL LOSS TEST SET

USER MANUAL OLS-100 Optical Light Source

Tools Single Unit Introduction. Fiber Checker Fiber Meter Light Source

IQS-2100/FLS-2100 OPTICAL LIGHT SOURCE. Telecom Test and Measurement

OPTICAL MEASURING INSTRUMENTS. MS9710B 0.6 to 1.75 µm GPIB OPTICAL SPECTRUM ANALYZER

OVA-50 Optical Variable Attenuator User s Manual

Agilent 81600B All-band Tunable Laser Source Technical Specifications December 2002

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

MS9020D. Optical Loss Test Set

Agilent 86146B Optical Spectrum Analyzer Technical Specifications

Pro. SimpliFiber. Getting Started Guide. Optical Power Meter and Fiber Test Kits

Agilent 8614xB Optical Spectrum Analyzer Family Technical Specifications

TURNKEY, ULTRA STABLE, OEM LASER DIODE SOURCE OZ-1000 & OZ-2000 SERIES

Advanced Test Equipment Rentals ATEC (2832)

EX-SFP-1GE-LX-A 1000Base-LX SFP Module 1310nm, 10Km, SMF, LC RoHS6

RF over Fiber Optic Transceiver OZ816 Series Ultra Broadband 6 GHz

Miniature, Ruggedized, 20 GHz RF over Fiber Transmitter

POLARIZATION EXTINCTION RATIO METER

PTR-1500 AUDIO TONE TELEPROTECTION TERMINAL FEATURES DESCRIPTION

Hand-held temperature calibrator Model CEP3000

Agilent 83440B/C/D High-Speed Lightwave Converters

Distance Sensors BOD 26K.... with optional Master-Slave-Mode

Advanced Test Equipment Rentals ATEC (2832)

Copper Lines and High Speed

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Beaming Optical Length Tester (BOLT)

Agilent 8703B Lightwave Component Analyzer Technical Specifications. 50 MHz to GHz modulation bandwidth

Complimentary Reference Material

Chapter 6 Specifications

RoHS Compliant 2x5 Small Form Factor Transceiver for Gigabit Ethernet

ROHS Compliant MM SFP Transceiver 1.25Gb Gigabit Ethernet

SHF Communication Technologies AG

3B SCIENTIFIC PHYSICS

TT7000R4. DS Instruments. D text. RF Power Meter, Signal Generator, Frequency Counter. -Key Features-

Voltage Sensors URV5-Z

Agilent 81980/ 81940A, Agilent 81989/ 81949A, Agilent 81944A Compact Tunable Laser Sources

GLC-LH-SMD-AO. 1.25Gbps SFP Transceiver

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

PV200. Why buy the PV200? The most compact I-V curve tracer around.

A3422 XMTDR. Digital Return Optical Transmitter Module. Features

Agilent 71400C Lightwave Signal Analyzer Product Overview. Calibrated measurements of high-speed modulation, RIN, and laser linewidth

RISH Max-12 and 14 Analog-Digital Multimeter. Data Sheet. RISH Max-12 and 14 Analog-Digital Multimeter. Rishabh Instruments

RF Signal Generator RIGOL TECHNOLOGIES, INC.

Rotary Measurement Technology Incremental Encoders

DIGITAL VARIABLE ATTENUATOR

NOW WITH BROADER TUNING RANGE

POLARIZATION EXTINCTION RATIO MEASUREMENT TEST SETFOR V-GROOVE ASSEMBLIES AND PM PATCHCORDS

Laboratory Grade Instruments Series & 4021 Power Meter SERIES Power Sensor

DTR-xxx-3.3-SM-T. 3.3 Volt Single Mode Transceivers (1x9 pin-out) ! Single +3.3 V supply & LV-PECL data interface. ! Eye Safe (Class I Laser Safety)

FiberLink 4040 Series

MW3105 DIGITAL CLAMP MULTIMETER

AXGE Gbps Single-mode 1310nm, SFP Transceiver

Technical Information itemp TMT180

Single-mode 266Mbps Transmitter / Receiver

User Manual. Portable C-band 26dB-gain EDFA Instrument in compact benchtop. (EDFA-C-26G-S, version 1.0b. January 28, 2015) Fiberprime, Inc.

Data Sheet. RISH Max-14 Analog-Digital Multimeter. RISH Max-14 Analog-Digital Multimeter. Page 1 of 5. Rishabh Instruments 1 / 05 / IX / 1210 / B

ES3112-3LCD Gbps SFP Optical Transceiver, 10KM Reach

SWT 3000 Teleprotection technical data siemens.com

STX / SRX SONET/SDH Transmitters & Receivers. Parameter Symbol Minimum Maximum Units Storage Temperature T st C

OPTICAL NODE TRUNK & DISTRIBUTION

Agilent EPM Series Power Meters

Exposure Level Tester ELT-400

Dynatel. 2273M Cable/Pipe and Fault Locators 2273M-iD Cable/Pipe/Fault and Marker Locators with id Read/Write

PV210. Why buy the PV210?

Keysight N9310A RF Signal Generator

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

PIPELINE DEFECT MAPPER

c A T v s y s T E N\ BAND MODEL 6103 Head End Cable TEst Return IIHECTER/' MODEL 6106 Carrier Generator/ Telemetry Receiver Field Unit I'HECTER'S PUP"

SFP CWDM Dual Channel Optical Transmitter

STABILA compact laser: For all professionals. For all finishing trades.

INGAAS FAST PIN (RF) AMPLIFIED PHOTODETECTORS

GLC-LH-SM-LEG-5PK. 1.25Gbps SFP Transceiver

Multi-Wavelength Meter AQ6141. Perfect for Wavelength Analysis in DWDM Systems

FFP-C Fiber Fabry-Perot Controller OPERATING INSTRUCTIONS. Version 1.0 MICRON OPTICS, INC.

SFP-ZX-SM Gbps SFP Optical Transceiver, 80km Reach

20 GHz High Power, High Linearity Photodiode Part #ARX zz-DC-C-FL-FC

Keysight N4373E 43.5/50/67 GHz Single-Mode Fiber Lightwave Component Analyzer for 100G/400G/1T Electro-Optical Test

FALL-OF-POTENTIAL GROUND RESISTANCE TESTER

TQ8215 Optical Power Multimeter

Variable Gain Photoreceiver Fast Optical Power Meter

OP-MP4 13L1SD-4 0. Product Features. Applications. General. 1.25Gb/s RoHS Compliant Pluggable SFP Transceiver

Miniature, Ruggedized, 20 GHz RF over Fiber Transmitter

Atlantic. series. Industrial High Power Picosecond DPSS Lasers

Handheld Spectrum Analyzer R&S FSH khz to 3 GHz

GLC-LH-SM-TX. Product Features. Applications. General. Cisco Compatible 1000BASE-LX/LH SFP TurboX

TES-1306 DIGITAL THERMOMETER INSTRUCTION MANUAL 1. SAFETY INFORMATION

SFP-GE-LX Gigabit Ethernet-Singlemode Transceiver SFP, Duplex LC Connector, 1310nm DFB 40km for Single Mode Fiber, RoHS Compliant

Variable Gain Photoreceiver - Fast Optical Power Meter

Q-SERIES. Optical. QFQR 200A-04 Series Return Path Optical Receiver. Installation & Operation Manual

Agilent 8614xB Optical Spectrum Analyzer Family Technical Specifications

Accutech AM20. Wireless acoustic monitor field unit

XFP BIDI Series JB1330-XFP-LC.S60. Features. Applications. Ordering information. Regulatory Compliance

MAGNETIC FIELD METER Operator s Manual

ASF Features. Applications. 1310nm SFP Single-Mode for 1.25G FC/GBE Duplex SFP Transceiver RoHS 6 Compliant

F6 Series Diode Lasers 6-Pin Fiber-Coupled Single-Stripe CW Devices

Transcription:

Measurement solutions for single-mode fibers Economical test solutions for ± installation ± maintenance and ± repair of single mode networks WG OMK-6 WG OVF-1 WG OLS-6 780/1300 nm WG OLP-6 WG OLS-6 1310/1550 nm The experience gained over many years in the field of optical measurement has resulted in a new, economical range of high-quality, rugged and reliable instruments. WG MT-32 The instruments are pocket-sized and fit in a handy belt pouch so they can be used anywhere as an everyday tool. The simple three-button operation, easy to read display and instrument characteristics have all been optimized for measuring absolute level and loss on optical fibers. Automatic recognition by the level meter of the wavelength transmitted by the level generator means that measurement errors are eliminated. The reference level for attenuation measurements conforming to IEC-874-1 (method 6) is stored for each wavelength separately at the press of a key. The reference value remains stored even when the instrument is switched off so that no battery power is wasted between making the reference measurement and the on-site measurement. This storage of a reference level for each wavelength coupled with the two laser modules built in to the OLS-6 means that dual-wavelength measurements at 1310/1550 nm or 780/1300 nm can be made quickly and easily. Individual fibers in a fiber optics cable can be identified rapidly and simply by transmitting modulated signals down the required fiber. The OLP-6 automatically detects the modulation frequency and indicates the correct fiber. Australia: Tel. +61-3-9690 6700 Brazil: Tel. +55-11-5505 3266 China: Tel. +86-10-6856 1034 Singapore: Tel. +65-356-3246 United Kingdom: Tel. +44-1189-409200 USA: Tel. +1-919 - 941-5730 Worldwide: Tel. +49-7121-86 16 16 Fax +49-7121-86 13 33 e-mail: info@wago.de http://www.wg.com

Economical, easy to handle and operate, yet highly reliable and robust. Designed from start to finish with users in mind. Dual Laser Source WG OLS-6 WG OLS-6 1310/1550 nm WG OLS-6 780/1300 nm. One FC/PC connector for each wavelength. Connectors can be removed from the casing for cleaning. Excellent short- and long-term stability thanks to level-stabilized laser source Reduces the need for time-consuming reference measurements. High output level for attenuation measurements over long distances (±7 dbm). Simple 3-button operation. Optimum protection of optical connectors with built-in cover ªIntelligentº laser beam makes life easier Single-wavelength mode or dual-wavelength mode. Measurement errors are avoided by automatic detection of the standard wavelength Single-wavelength mode. Automatic modulation frequency detection ideal for testing correct fiber connection Actual size. Ergonomic design. All-round shock protection. Robust and reliable

WG OLP-6 Optical Power Meter UPP (Universal push-pull interface). High-contrast easy-to-read display. For IEC 874-1 (method 6) attenuation measurements, the attenuation is shown directly in db without further calculation after the reference measurement.. Automatic display of battery capacity in % whenever the ON/OFF key is pressed.. BAT icon displayed during measurement to indicate the need to replace the batteries. Different connectors? No problem!. No more tiresome, time-consuming adapter changes. Simple push-pull mechanism. All common 2.5 mm connectors can be used ST SC E2000 FC DIN Usual life OLP-6 Operating life Long operating time (4130 h). Uses low-power components. Automatic power down activated after approx. 20 minutes. Uses two standard AA size (Mignon) 1.5 V batteries / NiCds ± available worldwide

The ideal pair for everyday measurements on single-mode fibers (1310/1550 nm) now available all in one as the WG OMK-6 Optical Test Kit Belt pouch. The practical solution. One with each instrument. Always at hand WG OMK-6 Optical Test Kit:. Optimized for attenuation measurements with a dynamic range of up to approx. 58 db in CW mode, corresponding to & 120 km fiber at 1310 nm & 190 km fiber at 1550 nm. The dynamic range in Auto-l or Modulation mode is around 40 db, corresponding to & 90 km fiber at 1310 nm & 130 km fiber at 1550 nm

Specifications OLS-6 Optical Laser Source OLS-6: 1310/1550 nm OLS-6: 780/1300 nm Optical source type FP laser FP laser Wavelength range 1310 nm typ. +20 nm 1550 nm +20 nm 780 nm +15 nm 1300 nm typ. +20 nm FWHM spectral width 57 nm / 57 nm 57 nm / 57 nm Output power (9/125 mm fiber) CW Modulated output level Class 1 laser ±7 dbm typ. +1 db typ. ±10 dbm Class 3A laser (780 nm) ±7 dbm +1.5 db typ. ±10 dbm Modulation frequencies 270 Hz, 1 khz, 2 khz 270 Hz, 1 khz, 2 khz Output signal stability Short-term: 15 min, ±10 to +55 ëc +0.02 db +0.05 db Long-term: 8 h, ±10 to +55 ëc +0.2 db +0.3 db Modes: CW AUTO-l FMOD DUAL Optical connector Power supply / operating time Dry batteries NiCd batteries Unmodulated light Output signal includes l information for WG level meters Modulation for fiber identification Both wavelengths active 2 outputs (1 for each wavelength); 26FC/PC 26Mignon (AA) 1.5 V / typ. 60 h 26Mignon (AA) 1.2 V / typ. 20 h 26Mignon (AA) 1.5 V / typ. 45 h ÐÐ OLP-6 Optical Power Level Meter OLP-6 Wavelength range....................... 780 to 1700 nm Photodiode................................ Germanium Fiber type......................... 9/125 to 100/140 mm Standard wavelength, switchable.............. 780 1), 850, 1300, 1310, 1550 nm Display range......................... ±65 to +10 dbm Maximum permitted level..................... +10 dbm Intrinsic measurement error 2).......... +0.13 db (+3 %) Linearity 2) ± 55 to +5 dbm.................... +0.06 db Wavelength detection 3) 4)........ automatic switch-over to and display of nominal wavelength Modulation detection 3)...... 270 Hz, 330 Hz, 1 khz, 2 khz Display Result display............................ LCD, 4-digit Results shown in............................. dbm, db Resolution................................... 0.01 db Battery charge state.............................. in % shown when instrument is switched on/off Reference level One measured value per wavelength can be stored Optical connector Universal Push-Pull Adapter (UPP) for all common plug connectors with 2.5 mm ferrules, e.g. DIN, ST, FC, SC, E2000 Power supply / operating time Dry batteries...................... 26AA (Mignon) 1.5 V or NiCd batteries................... 26AA (Mignon) 1.2 V Operating time (dry batteries).............. typically 130 h 1) 780 nm wavelength available from series B onwards 2) Under reference conditions: ± 20 dbm (CW), 1310 nm +2 nm, 23 ëc +3 ëc, 45 to 75% relative humidity 3) Level range at 1300 to 1550 nm: ± 50 to +10 dbm; at 780/850 nm: ± 45 to +10 dbm 4) Together with OLS-5, OLS-6 and OLS-15 from series E onwards General instrument specifications Discharge protection Instrument powers down automatically after about 20 minutes to conserve battery power (function can be disabled) Ambient temperature Nominal range of use...................... ±10 to +55 ëc Storage and transport..................... ±40 to +70 ëc Dimensions (b6h6t) in mm...... approx. 736286140 We ig h t (including batteries) OLS-6.................................. approx. 200 g OLP-6.................................. approx. 180 g Electromagnetic compatibility Meets EN 50081-1 and EN 50082-1 (CE conformance) OMK-6 Optical Test Kit OMK-6 contents: 16MK-5 Instrument Case complete with inlay 16OLS-6 Optical Laser Source, 1310/1550 nm 16OLP-6 Optical Power Level Meter 16Single-mode cable, FC/PC-FC/PC (9/125 mm), K 3112 46AA (Mignon) 1.5 V batteries Space is provided for OVF-1 (Optical Visible Fault Locator) Dynamic range of Loss Test Kit: CW mode..................................... 58 db Modulation or wavelength detection modes for 1310 to 1550 nm............................ 40 db for 780 to 850 nm.............................. 35 db Dimensions (b6h6t) in mm..... approx. 2656526225 Weight (including contents)............... approx. 900 g

Three practical solutions to the problem of measuring the physical parameters of systems and components in optical networks By combining individual instrument types into customized sets that fit into the MT-32 Instrument Bag, it is possible to always have the right instruments and appropriate accessories for every type of measurement ready to hand. These optimized test solutions mean that the only investment costs are those that are absolutely essential to solving the measurement problem. The combination of the new pocket-size OLX-5/-6 family with the high-performance OLX-15/-16/-18 range opens up new dimensions in customized test solutions for laboratory and field use. Example 1: Economical ªTWINtest solutionº for level and loss measurements on multimode and single-mode fibers: Measurement time halved by simultaneous measurement at 850/1300 nm on MM or at 1310/1550 nm on SM fibers. MT-32 Instrument Bag BN 2126/32 OLS-5 LED Source 850/1300 nm BN 2255/01 for MM fibers; ST adapter OLS-15 Laser Source 1310/1550 nm BN 2255/02 for SM fibers; universal adapter OLP-6 Optical Power Level Meter BN 2256/02 (± 65 to +10 dbm); Universal Push Pull Adapter OVF-1 Fault Locator for locating BN 2252/01 kinks and breaks in fibers Cleaning tape BN 2229/90.07 2 single-mode cables, FC/PC - FC/PC (9/125 lm) K 3112 2 multimode cables, ST-ST (50/125 lm) K 3027 FC/FC coupler S 3101 ST/ST coupler S 3109 1 Charger Unit for external charging of NiCd batteries: 220 V, Euro-style a.c. line plug BN 2229/90.03 Example 2: Economical ªQuad-wavelength solutionº for qualification of fiber optics cables by means of level and loss measurements in the optical windows of single-mode fibers MT-32 Instrument Bag BN 2126/32 OLS-6 Laser Source 1310/1550 nm BN 2255/02 for SM fibers; FC/PC adapter OLS-6 Laser Source 780/1300 nm BN 2255/03 for SM fibers; FC/PC adapter OLP-6 Optical Power Level Meter BN 2256/02 (± 65 to +10 dbm) OVF-1 Fault Locator for locating kinks BN 2252/01 and breaks in fibers Cleaning tape BN 2229/90.07 2 single-mode cables, FC/PC - FC/PC (9/125 mm) K 3112 FC/FC coupler S 3101 1 Charger Unit for external charging of NiCd batteries: 220 V, Euro-style a.c. line plug BN 2229/90.03 Example 3: Economical ªSystem installation solutionº for measuring absolute level and receiver sensitivity in single-mode systems. MT-32 Instrument Bag BN 2126/32 OLS-6 Laser Source 1310/1550 nm BN 2255/02 for SM fibers; FC/PC adapter OLP-6 Optical Power Level Meter BN 2256/02 (± 65 to +10 dbm); Universal Push Pull adapter OLA-15 Optical Attenuator; BN 2239/01 Universal adapter Cleaning tape BN 2229/90.07 2 single-mode cables, FC/PC - FC/PC (9/125 mm) K 3112 1 Charger Unit for external charging of NiCd batteries: 220 V, Euro-style a.c. line plug BN 2229/90.03 Ordering information WG OLS-6 Optical Laser Source WG OLS-6 1310/1550 nm BN 2255/02 1310/1550 nm (pack of 10) BN 2255/20 780/1300 nm BN 2255/03 WG OLP-6 Optical Power Level Meter BN 2256/02 WG OMK-6 Optical Test Kit BN 2126/06 Comprising: 16MK-5 Instrument Case complete with inlay 16OLS-6 Optical Laser Source, 1310/1550 nm 16OLP-6 Optical Power Level Meter 16Single-mode cable, FC/PC-FC/PC (9/125 mm), K 3112 46AA (Mignon) 1.5 V batteries Space is provided for OVF-1 (Optical Visible Fault Locator) WG OMK-6 Optical Test Kit (pack of 10) BN 2126/60 Accessories Calibration report for OLS-6 BN 2255/90.03 Calibration report for OLP-6 BN 2256/90.02 NiCd battery AA (Mignon) size BN 2229/90.02 (2 required for each instrument) Charger unit (for external charging of NiCd batteries) 230 V, Euro-style a.c. line plug BN 2229/90.03 110 V, US-style a.c. line plug BN 2229/90.09 MK-5 Transport Case BN 2126/90.01 (for holding 2 instruments) WG MT-32 Transport Case BN 2126/32 (for holding 3 instruments) Detailed information on adapters, cables and optical couplers is found in the separate data sheet on ªOptical test adapters and adapter cablesº. Subject to change without notice ± E/0498/D1/978/3.5 ± Printed in Germany Wandel & Goltermann Germany Wandel & Goltermann Communications Test Solutions