Operation Manual PA-9312/9324/9336/9348. Public Address Power Amplifier

Similar documents
Operation Manual PA-6312/6324/6336/6348. Public Address Power Amplifier

Welcome Warning...1 Unpacking...2. Installation Environment...2 Important Safety Instructions...2. Features...3 Accessories...3

PA-9312/9324/9336 Public Address Power Amplifier

VCA-100 Wall Volume Controller

Operation Manual. Public Address Amplifier MA-106

Operation Manual. Digital Amplifier MA-110/110N

Operation Manual. Pre Amplifier PP-6214

A-60/120 Public Address Amplifier

RM-05A Remote Amp with Zone Selector

Operation Manual. Mixing Amplifier PA-360/480/600

PP-9213 Pre Amplifier

Operation Manual. Professional Power Amplifier V2-1000/2000/3000/4000

L800/1400/1800/2400 Professional Power Amplifier

Operation Manual. Digital Amplifier MA-103

Operation Manual. Dual 31-Band Graphic Equalizer EQ-2231A

R150 PLUS/300 PLUS/500 PLUS Reference Amplifier

PT-9107SD Stereo Tuner

Operation Manual. Public Address Amplifier PAM-120A/340A/480A

PA-2312 Public Address 2 CH Power Amplifier

PP-9214 Pre Amplifier

PAM-240A/360A Public Address Amplifier

PAM-240/360 Public Address Amplifier

H-3200/4200 Professional Power Amplifier OFF

Operation Manual FTA-108S/ITX-108/ITX /8 Channel Audio Transmitter/Receiver. Transmitter: Receiver: FRA-108S/IRX-108/IRX-102

PT-9107SD Stereo Tuner

L800/1400/1800/2400/3000 Professional Power Amplifier

Inter-M, Ltd. (Korea) began operations in 1983.

EQ-2131/2231/2215 Graphic Equalizer

Operation Manual. Mixing Amplifier PA-60/120/240

Inter-M, Ltd. (Korea) began operations in 1983.

Operation Manual QD-4240/4480/4960 QX Quad Amplifier

Operation Manual TP-6231A. Telephone Paging

Big Bang. B B O w n e r s M a n u a l. Power Amplifiers. SpeakerCraft BB2125 POWER ACTIVE PROTECTION L

ECA COMMERCIAL AMPLIFIER OWNER S MANUAL ECA-70MIXAMP V / 70V / 4Ω Amplifier ECA-70MIXAMP-1-60 OUTPUT LEVEL POWER MASTER MIC 1

REVAMP4100 Instruction manual

A Channel Amplifier

Model CC4041. CC Series Amplifier. Installation and Use Manual

REVAMP4120T Instruction manual

PAT-20TB MOBILE PUBLIC ADDRESS AMPLIFIER WITH TALK BACK SYSTEM

WX-1 & WX-3 OPERATING MANUAL AND USER GUIDE. Professional Power Amplifier. WX-1 and WX-3.indd :23:16

3.Avoid spilling liquids or allowing materials to enter the cabinet

IMPORTANT SAFETY INSTRUCTIONS

R-Series R235LS 2-Channel Power Amplifier with Local Source Switching

Model CC4052. CC Series Amplifier. Installation and Use Manual

AMPLIFIER QD-4240/4480

PT-9107S Stereo Tuner

HTA125A/250A. Power Amplifiers. Installation & Use Manual

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS

Classic Series Public Address Amplifiers C10 & C20 Models

REVAMP2250 Instruction manual

KLASIK NEAR FIELD ACTIVE STUDIO MONITOR

2BSST POWER AMPLIFIER OWNER S MANUAL

Important Safety Information

plifier D-501 otion Am Tactile M

M-300 Mono power amplifier User s guide

User Guide. Wideband 4-channel Auto Gain-Control Antenna Divider

DPA-1.2. Instruction Manual. 2 Channel Amplifier with Auto A/B Selector DPA-1.2 DPA-1.2 POWER SERIAL # LINE INPUT SENSING SPEAKER B OUT

Mini-Z. Manual. Model: ZA-21.

Lanen Series 21 from Prodipe SB21 Lanen Instrument Mic. User Manual SB21 Lanen Sax / Brass / Percussion

CR31. Companion. Instruction Manual

Primare A33.2 Amplifier User Guide

DA216S DISTRIBUTION AMPLIFIER

POWERED MIXER DIGITAL ECHO EFFECT ECHO LEVEL ECHO LEVEL ECHO LEVEL ECHO LEVEL ECHO VOL REPEAT MPM CHANNEL POWERED MIXER OWNER S MANUAL

HARMONY SINGER 2. Battery-Powered Vocal Effects Stompbox with Guitar-Controlled Harmony, Reverb and Tone. User Manual

Classic Series Public Address Amplifiers C10 & C20 Models

A-16D A-Net Distributor

DSR-3. Bedienungsanleitung User Guide

User Manual. ia480x Power amplifier

User Manual. MA 240 Mixing amplifier

1695T Black Magick. User Manual

User Manual LMS-325 Line Monitor Speaker

MC58 Eight Channel Power Amplifier

MIC MECHANIC 2. Ultra-Simple Battery-Powered Vocal Effects Stompbox with Echo, Reverb and Pitch Correction. User Manual

Lanen True Diversity UHF Systems For electric and bass guitars: GB21 For Series 21 mics: UHF21. User Manual GB21 receiver/uhf21 transmitter

PREZONE1 Instruction manual

USER MANUAL APG DYNAMIC PROCESSORS MATRIX ARRAY SYSTEMS 4000SP 6000SP 9000SP

MAZ 18/MAZ 38. Manual. Model: ZA-8 / ZA-5.

Classic Series Amplifiers C35, C60, & C100 Models

arthur ART48 - YELLOW ACOUSTIC FIDELITY USER MANUAL Assembling instruction on ART48-L/Rmast manual

SAGA PRO SERIES STEREO POWER AMPLIFIER OPERATION MANUAL

XD-V30 Digital Wireless System

UA ª 35T II Utility Amplifier OPERATING INSTRUCTIONS

User Manual. imix 63 Stereo mixing preamplifier

FOR AVLEX ONLY MT-24A. User Guide. 2.4 GHz Digital Stationary Transmitter

A32. f u l l y b a l a n c e d p o w e r a m p l i f i e r. user guide

Audio Systems. Mono Amplifier with Subwoofer Crossover OWNER S MANUAL

MODEL A1. PackLite TM POWER AMPLIFIER

RackAmp 250 AMPLIFIER MANUAL WARRANTY INFORMATION

STEREO POWER AMPLIFIER OWNER MANUAL PR-150 DESIGNED IN U.K. PDF created with FinePrint pdffactory trial version

Operation Manual. Mixing Amplifier PMU-60N/120N/240N

3400 Watt Stereo Power Amplifier

a u d i o p h i l e d i g i t a l - t o - a n a l o g u e c o n v e r t e r user guide

IMPORTANT SAFETY INSTRUCTIONS

PROLUDE AMPLIFICATION D750. User s manual for the tube preamplifier version

CANARY AUDIO. EL34 Stereo Power Amplifier. Handcrafted in California CA-770 OWNER S MANUAL MADE IN USA

EPA104/254. User Manual.

w i t h T A B L E O F C O N T E N T S Safety Information 2 Certifications/Standards 3

Page 1 of 6 Systems Inc.

THE NEW FACE OF BASS PRO BASS SYSTEM U30, U60, U120. Owner s Manual

Transcription:

Operation Manual Public Address Power Amplifier PA-9312/9324/9336/9348 * Rack mount products in the Western Hemisphere(North America, South America, and the Caribbean) do not have handles installed due to customer preference.

Contents Welcome Warning...1 Unpacking...2 Installation Environment...2 Important Safety Instructions...2 Features...3 Accessories...3 Operation...3 Front Panel...4 Rear Panel...5 Connecting Speakers...7 Applications...8 Block Diagram...9 Specifications...11 Service Procedures...12 Schematic...12 Parts List...12 Variations and Options...12 Warranty...12

Welcome A personal welcome to you from the management and employees of Inter-M All of the co-workers here at Inter-M are dedicated to providing excellent products with inherently good value, and we are delighted you have purchased one of our products. We sincerely trust this product will provide years of satisfactory service, but if anything is not to your complete satisfaction, we will endeavor to make things right. Welcome to Inter-M, and thank you for becoming part of our worldwide extended family! CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN This symbol is intended to alert the user to the presence of uninsulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK. DO NOT REMOVE COVER (OR BACK). NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. Caution: This symbol is intended to alert the user to the presence of important operation and maintenance (servicing) instructions in the literature accompanying the appliance. To prevent electric shock do not use this (polarized) plug with an extension cord, receptacle or other outlet unless the blades can be fully inserted to prevent blade exposure. WARNING To prevent fire or shock hazard, do not expose the unit to rain or moisture. Attentions: Pour prévenir les chocs électriques ne pas utiliser cette fiche polarisée avec un prolongateur, une prise de courant on une autre sortie de courant, sauf si les lames peuvent étre insérées à fond sans en laisser aucune partie à découvert. *Do not install this equipment in a confined space such as a book case or similar unit. *The apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such vases, shall be placed on the apparatus. *Worded: WARNING FOR YOUR PROTECTION PLEASE READ THE FOLLOWING-WATER AND MOISTURE: Unit should not be used near water(e.g. near a bathtub, washbowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool, etc). Care should be taken so than objects do not fall and liquids are not spilled into the enclosure through openings. PA-9312/9324/9336/9348 1

Unpacking Although your PA-9312/9324/9336/9348 is neither complicated nor difficult to operate, we recommend you take a few minutes to read this brief manual and familiarize yourself with the important information regarding product features, setup and operation. As with most electronic devices, we strongly recommend you retain the original packaging. In the unlikely event the product must be returned for servicing, the original packaging (or reasonable equivalent) is required. Installation Environment Never place this product in an environment which could alter its performance or reduce its service life. Such environments usually include high levels of heat, dust, moisture, and vibration. Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Clean only with dry cloth. 7. Do not block any ventilation openings. Install in accordance with the manufacturer s instructions. 8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. 10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus. 11. Only use attachments/accessories specified by the manufacturer. 12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over. 13. Unplug this apparatus during lightning storms or when unused for long periods of time. 14. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. S3125A 2 PA-9312/9324/9336/9348

Features - HIGH POWER, LOW DISTORTION - 120W (PA-9312), 240W (PA-9324) or 360W (PA-9336) of RMS power, with less than 1% THD. - 480W(PA-9348) of RMS power, with less than 5% THD. - BALANCED INPUT Balanced XLR inputs to reduce ground hum and increase efficiency. - GAIN ADJUSTMENT Input gain is adjustable from 12dB to 0dB (1V) via rear panel control. - EMERGENCY BATTERY BACKUP Emergency battery backup for unexpected AC power failure. - SLIM DESIGN, COMPACT SIZE Streamlined design fits in a compact 3RU space. Accessories One detachable AC power cord and XLR cord are provided for use with this product. Operation Make certain that speakers and input sources are properly connected before switching on. Keep volume levels turned down before switching on. NOTE: The system s operation is delayed by approximately three seconds after pressing the power switch. This is due to the built-in protection circuitry, designed to protect speakers and other system components. PA-9312/9324/9336/9348 3

Front Panel 1 2 3 PA 9348 PUBLIC ADDRESS POWER AMPLIFIER OUTPUT & PROTECTION PROT POWER CLIP ON 10dB OFF 40dB 4 5 1. FAN VENTS These vents provide cool air flow into the unit. It is important to keep them free of obstructions, to prevent the unit from overheating. It is also important to operate the unit in a dust-free environment. 2. PROTECTION INDICATOR This LED indicates the state of the amplifier s protection circuitry. When the Protection LED is on (illuminated), the protection circuitry is active, indicating that the unit is not operating normally. This is typically due to overheating or power limiting. Please check the Input and Output condition of the amplifier. 3. POWER LED When the unit is powered on, the Power LED will glow steadily. 4. OUTPUT LEVEL INDICATOR These three LEDs indicate the amplifier s output status. The 40dB LED indicates the presence of audio signal at the amplifier s output. The 10dB LED indicates output at nominal operating range. The red CLIP LED indicates an excessive output level. Do not operate the unit with the CLIP LED continuously on (illuminated). 5. POWER SWITCH Pressing this switch turns the unit on, as indicated by the Power LED. Pressing it again turns the unit off. 4 PA-9312/9324/9336/9348

Rear Panel 1 2 3 OUTPUT B A COM 43.8V(4Ω) 62V(8 Ω) 70V(10.2 Ω) www.inter-m.com ~AC INPUT 120V 60Hz, 600W BALANCED INPUT 1V/10KΩ LINK INPUT(ADJ) ) HPF ON OFF GROUND LIFT FUSE : T15AH / 250V 12dB 0dB FLOAT FRAME DC INPUT 24V 4 5 6 7 8 9 1. SPEAKER OUTPUT TERMINALS These terminals are used to connect speakers to the unit. You may select either 4Ω or 8Ω conventional operation, or High Impedance operation at either 70V or 100V. Make certain the combined impedance of the speakers is equal to or higher than the rated output impedance of the amplifier. The impedance and output voltage are as follows. Countries USA/CANADA & Associated Version EC & Associated, JAPAN Version Output Terminals 4Ω 8Ω 25V 70V 4Ω 70V 100V PA-9312 22V - 5.2Ω 41Ω 22V 41Ω 83Ω PA-9324 31V - 2.6Ω 21Ω 31V 21Ω 42Ω PA-9336 38V 54V - 13.6Ω 38V 13.6Ω 27.8Ω PA-9348 43.8V 62V - 10.2Ω 43.8V 10.2Ω 20.8Ω 2. LEVEL CONTROL This knob provides continuous control of the amplifier s output level, from 12dB to 0dB (reference input of 0dB at 1V). Turning the knob clockwise increases the level, and turning it counter-clockwise decreases the level. PA-9312/9324/9336/9348 5

3. FAN VENTS These vents provide hot air flow out of the unit. It is important to keep them free of obstructions, to prevent the unit from overheating. It is also important to operate the unit in a dust-free environment. 4. AC POWER INPUT Connect the supplied standard AC input cable here. 5. FUSE HOLDER This holder contains the AC overload protection fuse. If the fuse has blown out, replace it with a fuse of the same type and rating. If the fuse continues to blow, refer servicing to a qualified service technician. 6. HIGH-PASS FILTER SWITCH This switch activates the high-pass filter circuitry, which decreases frequencies lower than 400Hz by 3dB. The high-pass filter is designed to protect speakers from damage caused by excessive low frequency transients. 7. AUDIO INPUTS These balanced XLR jacks are for the input of audio signal. 8. GROUND LIFT SWITCH This switch provides for connection or disconnection of the amplifier s ground to AC earth ground, to prevent noise from ground loops. Under most circumstances, this switch should be set to FRAME position. 9. DC INPUT TERMINALS These terminals are provided for the connection of backup battery. Connect a 24VDC(100A) battery source to these terminals. Make certain the red terminal is connected to the battery s positive (+) side, and the black terminal to the battery s negative (-) side. 6 PA-9312/9324/9336/9348

Connecting Speakers Connecting Speakers Before connecting speakers to your PA-9312/9324/9336/9348 unit, be sure to disconnect the AC power cable. Make certain that the total impedance is not less than the rated impedance indicated. For 4Ω speakers, connect the positive (+) connector to the 4Ω terminal and the negative (-) connectors to the COM terminal. For high-voltage distributed systems, connect with matching transformer to the COM and either B or A terminals. Be certain that the total impedance does not equal less than the rated impedance. *The impedance and output voltage are as follows. Countries USA/CANADA & Associated Version EC & Associated, JAPAN Version Impedance Low High (B) High (A) Low High (B) High (A) Output Terminals 4Ω 8Ω 25V 70V 4Ω 70V 100V PA-9312 22V - 5.2Ω 42Ω 22V 42Ω 83Ω PA-9324 31V - 2.6Ω 21Ω 31V 21Ω 42Ω PA-9336 38V 54V - 13.6Ω 38V 13.6Ω 27.8Ω PA-9348 43.8V 62V - 10.2Ω 43.8V 10.2Ω 20.8Ω PA-9312/9324/9336/9348 7

COM 43.8V(4 ) 62V(8 ) 70V(10.2 ) ON AMP IN 1 ALL GROUP 2 AMP IN 2 GROUP 1 TIMER OFF REMOTE FLOAT FRAME DC INPUT 24V CH 16 CH 15 CH 14 CH 13 CH 12 CH 11 CH 10 CH 9 CH 8 CH 7 CH 6 CH 5 CH 4 CH 3 CH 2 CH 1 ON PUBLIC ADDRESS POWER AMPLIFIER Applications CD-3500 PP-9213 MIC 1 1 1 2 2 2 MASTER OUTPUT SUB OUT PRIORITY INPUT AUX INPUT L L L REC OUT INSERT - + DC INPUT 24V R CH9 R CH8 R CH7 CH6 CH5 CH4 CH3 DUCK P.PWR DUCK P.PWR CH2 CH1 PA-9348 OUTPUT B A www.inter-m.com BALANCED INPUT 1V/10K LINK HPF INPUT(ADJ) ) GROUND LIFT FUSE : T15AH / 250V 12dB 0dB DC INPUT 24V SPEAKER PS-9116 (+) (+) (-) S N - + (-) PD-9359 REMOT EMERGENCY MODEL ES-9116 PX-9116 RG-9116 EP-9216 PB-9207A AC IN BATTERY IN ( ) ( ) S N * When using connected to a power outlet of PD-9359, the only one (PA-9348) must connect the plug to the separate outlet block. 8 PA-9312/9324/9336/9348

Block Diagram - PA-9312/9324 PA-9312/9324/9336/9348 9

Block Diagram - PA-9336/9348 10 PA-9312/9324/9336/9348

Specifications PA-9312 PA-9324 PA-9336 PA-9348 Rated Output Power (THD 5%, 1kHz) 120W 240W 360W 480W Frequency Response (+1/-3dB) 70Hz-18kHz T.H.D Less than 1% Less than 5% High Pass Filter (400Hz) Gain Control -3dB -12dB S/N Better than 95dB Better than 90dB Input Sensitivity/Impedance 1V/10kΩ Balanced Output Voltage/Impedance 4Ω/22V 4Ω/31V 4Ω/38V 4Ω/43.8V 5.2Ω/25V 2.6Ω/25V 8Ω/54V 8Ω/62V 41Ω/70V 21Ω/70V 13.6Ω/70V 10.2Ω/70V 83Ω/100V 42Ω/100V 27.8Ω/100V 20.8Ω/100V Operating Temperature Power Source -10 C ~ +40 C 100 120VAC or 220 240VAC; 50/60Hz, 24VDC (Supplied AC mains transformer depends on country requirements) Power Consumption(1/8 power) 130W 310W 380W 600W Weight 14kg/30.8lb 19kg/41.9lb 21kg/46.3lb 22kg/48lb Dimensions 482(W) 132(H) 280(D)mm/19(W)x5.2(H)x11(D)in * Specifications and design subject to change without notice. PA-9312/9324/9336/9348 11

Service Procedures Take steps to insure the problem is not related to operator error or other products within the system. Information provided in the troubleshooting portion of this manual may help with this process. Once it is certain that the problem is related to the product contact your warranty provider as described in the warranty section of this manual. Schematic A Schematic is available by contacting your warranty provider. Parts List A Parts List is available by contacting your warranty provider. Variations and Options Variations Products supplied through legitimate sources are compatible with local AC power requirements. Options No optional items are available for this product. Warranty Warranty terms and conditions vary by country and may not be the same for all products. Terms and conditions of warranty for a given product may be determined first by locating the appropriate country which the product was purchased in, then by locating the product type. To obtain specific warranty information and available service locations contact Inter-M directly or the authorized Inter-M Distributor for your specific country or region. 12 PA-9312/9324/9336/9348

Inter-M, Ltd. (Korea) began operations in 1983. Since then, Inter-M has grown to become one of the largest manufacturers of professional audio and commercial sound electronics equipment in the world. Inter-M has gained worldwide recognition for its own branded products, as well as private label manufacturing of electronics sold under other names (OEM). The company is no longer just a Korean company, but rather a global company that is truly international in scope, with factories and offices in Korea and China, and sales and marketing operations located in Japan, Europe, and the U.S.A. With more than 850 employees around the globe, Inter-M is well-poised for further growth and expansion. Inter-M Americas, INC. 13875 ARTESIA BLVD. CERRITOS, CA 90703 USA TEL : +1-562-921-0313, FAX : +1-562-921-0370 Home Page : http://www.inter-m.net, E-mail : info@inter-m.net Inter-M Corporation SEOUL OFFICE:653-5 BANGHAK-DONG, DOBONG-KU, SEOUL, KOREA TEL : +82-2-2289-8140~8, FAX : +82-2-2289-8149 Home Page : http://www.inter-m.com, E-mail : overseas@inter-m.com MADE IN KOREA April 2006 9000000420