Effect of Surge Arrester on Overhead Transmission Lines as Shield against Over Voltage

Similar documents
Utility System Lightning Protection

Tab 8 Surge Arresters

SURGE ARRESTERS AND TESTING. Keith Hill Doble Engineering Company

The Many Uses of Transmission Line Arresters

Lightning performance of a HV/MV substation

A Case Study on Selection and Application of Lightning Arrester and Designing its Suitable Grounding Grid

Analysis of lightning performance of 132KV transmission line by application of surge arresters

ABSTRACTS of SESSION 6

Modeling of overhead transmission lines with line surge arresters for lightning overvoltages. Poland

Lightning Protection of Distribution Substations by Using Metal Oxide Gapless Surge Arresters Connected in Parallel

Session Four: Practical Insulation Co-ordination for Lightning Induced Overvoltages

Effect of High Frequency Cable Attenuation on Lightning-Induced Overvoltages at Transformers

Lightning overvoltage and protection of power substations

VFTO STUDIES DUO TO THE SWITCHING OPERATION IN GIS 132KV SUBSTATION AND EFFECTIVE FACTORS IN REDUCING THESE OVER VOLTAGES

Power Quality and Reliablity Centre

PREVENTING FLASHOVER NEAR A SUBSTATION BY INSTALLING LINE SURGE ARRESTERS

Computer Based Model for Design Selection of Lightning Arrester for 132/33kV Substation

Analysis of MOV Surge Arrester Models by using Alternative Transient Program ATP/EMTP

LIGHTNING OVERVOLTAGES AND THE QUALITY OF SUPPLY: A CASE STUDY OF A SUBSTATION

Modeling insulation in high-voltage substations

(2) New Standard IEEE P (3) Core : (4) Windings :

High voltage engineering

Journal of Asian Scientific Research SUBSTATION PROTECTION AND THE CLIMATIC ENVIRONMENT OF NIGER DELTA. John Tarilanyo Afa

EE 1402 HIGH VOLTAGE ENGINEERING

Insulation Co-ordination For HVDC Station

HIGH VOLTAGE Insulation Coordination

Calculation of Transient Overvoltages by using EMTP software in a 2-Phase 132KV GIS

Protection against unacceptable voltages in railway systems

X International Symposium on Lightning Protection

Maximum Lightning Overvoltage along a Cable due to Shielding Failure

When surge arres t ers are installed close to a power transformer, overvoltage TRANSFORMER IN GRID ABSTRACT KEYWORDS

Effect of Shielded Distribution Cables on Lightning-Induced Overvoltages in a Distribution System

ANALYSIS OF A FLASHOVER OPERATION ON TWO 138KV TRANSMISSION LINES

Simplified Approach to Calculate the Back Flashover Voltage of Shielded H.V. Transmission Line Towers

B2-301 IMPROVING DOUBLE CIRCUIT TRANSMISSION LINE RELIABILITY THROUGH LIGHTNING DESIGN

In order to minimise distribution (11 and 22 kv) feeder breaker

AMENDMENT NO. 1 SEPTEMBER IS (Part 1) : 2001/IEC (1991) SURGE ARRESTORS

Substation Insulation Coordination Study

2 Grounding of power supply system neutral

Voltage Sag Mitigation by Neutral Grounding Resistance Application in Distribution System of Provincial Electricity Authority

The relationship between operating maintenance and lightning overvoltage in distribution networks based on PSCAD/EMTDC

VariSTAR Type AZL heavy-duty distribution-class MOV arrester

Simulation and Analysis of Lightning on 345-kV Arrester Platform Ground-Leading Line Models

TECHNICAL NOTE 2.0. Overvoltages origin and magnitudes Overvoltage protection

Computation of Lightning Impulse Backflashover Outages Rates on High Voltage Transmission Lines

Arrester 2050 JONATHAN WOODWORTH

Electric System Overvoltage Protection

Lightning current field measurement on a transmission line, comparison with electromagnetic transient calculations

Hazard of Induced Overvoltage to Power Distribution Lines Jiang Jun, Zhao Rui, Chen Jingyang, Tian Hua, Han Lin

CHOICE OF MV FEEDER BIL TO MAXIMIZE QOS AND MINIMIZE EQUIPMENT FAILURE

Parameters Affecting the Back Flashover across the Overhead Transmission Line Insulator Caused by Lightning

Analysis of current distribution among long-flashover arresters for 10 kv overhead line protection against direct lightning strikes

Lightning Performance Improvement of 115 kv and 24 kv Circuits by External Ground in MEA s Distribution System

The line-lightning performance and mitigation studies of shielded steelstructure

7P Series - Surge Protection Device (SPD) Features 7P P P

Simulation Study on Transient Performance of Lightning Over-voltage of Transmission Lines

2000 Mathematics Subject Classification: 68Uxx/Subject Classification for Computer Science. 281, 242.2

Problems connected with Commissioning of Power Transformers

ABSTRACT 1.0 INTRODUCTION LIST OF SYMBOLS

AORC Technical meeting 2014

Insulation Coordination Fundamentals Where Arrester and Insulator Characteristics Meet

GIS Disconnector Switching Operation VFTO Study

Surge Arresters. VariSTAR Type AZS Normal Duty Distribution Class MOV Arrester

Lightning transient analysis in wind turbine blades

Analysis of Major Changes to Arrester Standards IEC STEVE BREWER

Modeling and Analysis of a 3-Phase 132kv Gas Insulated Substation

International Journal of Advance Engineering and Research Development. Analysis of Surge Arrester using FEM

Research on State Estimation and Information Processing Method for Intelligent Substation

Lightning phenomena and its effect on transmission line

University of Zagreb Faculty of Electrical Engineering and Computing

OVERVOLTAGE PROTECTION. Dimensioning, testing and application of metal oxide surge arresters in low-voltage power distribution systems

10. DISTURBANCE VOLTAGE WITHSTAND CAPABILITY

A Simple Simulation Model for Analyzing Very Fast Transient Overvoltage in Gas Insulated Switchgear

EMC Philosophy applied to Design the Grounding Systems for Gas Insulation Switchgear (GIS) Indoor Substation

ROEVER ENGINEERING COLLEGE ELAMBALUR, PERAMBALUR DEPARTMENT OF ELECTRICAL & ELECTRONICS ENGINEERING

RESULTS OF EXPERIMENTAL HIGH CURRENT IMPULSE 4/10 s OF METAL OXIDE VARISTORS ZINC IN THE HIGH VOLTAGE 220KV SURGE ARRESTER

Earthing of Electrical Devices and Safety

Industrial Electrician Level 3

Fatima Michael College of Engineering & Technology

Electric Stresses on Surge Arrester Insulation under Standard and

Substation Design Volume VII

Transmission of Electrical Energy

Influence Of Lightning Strike Location On The Induced Voltage On a Nearby Overhead Line

Secondary Arresters. Figure 1. Type L secondary surge arrester rated 175 Vac, 125 Vdc.

MAHALAKSHMI ENGINEERING COLLEGE

ARC FLASH HAZARD ANALYSIS AND MITIGATION

EVALUATION OF LIGHTNING-INDUCED VOLTAGES ON LOW-VOLTAGE DISTRIBUTION NETWORKS

FERRORESONANCE SIMULATION STUDIES USING EMTP

DEVELOPMENT OF A TEST PROTOCOL FOR A 15 KV CLASS SOLID-STATE CURRENT LIMITER

Effects of Phase-Shifting Transformers, and Synchronous Condensers on Breaker Transient Recovery Voltages

APPLICATION OF LONG FLASHOVER ARRESTERS FOR IMPROVEMENT OF LIGHTNING PROTECTION AND OPERATING VOLTAGE RELIABILITY OF DISTRIBUTION LINES

COOPER POWER. UltraSIL Polymer-Housed VariSTAR Type U2Surge Arrester for Systems through 275 kv IEC 10-kA; Line Discharge Class 2 SERIES

Overview of Grounding for Industrial and Commercial Power Systems Presented By Robert Schuerger, P.E.

Energy Division. Bowthorpe LV/MV Surge Arresters

Power Frequency Withstand Voltage On-site testing of 400 kv GIS

Transient Recovery Voltage (TRV) and Rate of Rise of Recovery Voltage (RRRV) of Line Circuit Breakers in Over Compensated Transmission Lines

Simulation of Short Circuit and Lightning Transients on 110 kv Overhead and Cable Transmission Lines Using ATP-EMTP

Minimum Leakage Current for Dry Band Formation under Polluted Environment

ABSTRACT 1 INTRODUCTION

DIFFERENCE BETWEEN SWITCHING OF MOTORS & GENERATORS WITH VACUUM TECHNOLOGY

Transcription:

Effect of Surge Arrester on Overhead Transmission Lines as Shield against Over Voltage Swati Agrawal Assistant Professor, MATS University, Raipur (C.G) Abstract: This paper describes the usage of surge arrester to reduce effect of lightning stroke on transmission line. Voltage induced on overhead transmission lines due to lightning phenomena is one of the major reasons for the flash over voltage and outages. Lightning being one of the most natural and serious causes of high voltage. Determination of the maximum voltages induced on the overhead line by direct stroke is a complex problem. Distribution circuits typically are not insulated to withstand direct lightning strokes, as a result, direct strikes will cause a flash over between phase to phase or phase to ground depending upon the arc path. For estimating the flashover due to direct strokes, it is necessary to calculate the maximum voltage induced on the line. The effect of direct lightning on transmission lines have been analyzed with and without the help of surge arrester. Keywords: Surge arrester, over voltage, conductor, lightning, flash over. I. INTRODUCTION On many transmission lines lightning impulse is the main cause of unscheduled supply interruption. A number of methods for estimating trip out rates have been deployed. The voltages produced on overhead lines by lightning might be due to indirect or direct strokes. Therefore a lightning stroke to a transmission line conductor injects a transient current of several thousand amperes. Our aim is to obtain maximum over voltage value that might occur on the transmission system for analysis purpose. Various circuit configurations is selected from the existing 11KV transmission system. The objective is to calculate induced over voltage from lightning. As a consequence, their evaluation has been for years, and is still, one of the most important problems in designing and coordinating the protection of overhead transmission lines. A better knowledge of the over voltages experienced on a simple 11KV circuit could improve our ability to select equipment such as switches, arresters and BILs level of transformer. It would also provide input into the design parameters for live line tools, cover up equipment, insulation levels and barriers used to build or maintain such transmission systems. II. METHODOLOGY: Arresters have been introduced for the protection of transmission lines as an alternative to overhead ground wires. They are placed out at intervals on the poles or towers. Voltage across the line insulator at the point of installation is controlled by the MOV (Metal Oxide Varistors) and kept below flashover voltage of the insulator to avoid back flashover which is most frequent form of lightning outage. The voltage across the line insulation is greatly influenced by the high tower footing resistance. The entire lightning event is referred to as a flash and the individual pulses are referred to as strokes and when this current injects on phase conductor, voltage waves radiate from the point of contact in both directions along the conductor and down the tower if flashover occurred across insulator to tower. These waves rapidly encounter discontinuities which initiate reflected waves, which generate another waves when they return to the stricken point. In this way a large number of waves are generated in short order. The effect of these waves will depend on the change of surge impedance at this discontinuity. Available online @ www.ijntse.com 1

The potential difference across the suspension insulators is of particular concern since a flashover can occur and a fault be placed on the phase if this voltage becomes excessive. When direct lightning strikes on overhead phase conductors,magnitude of the current and high frequency nature of the stroke causes voltage surges to be propagated in both directions from the point of strike and the two travelling voltage waves originates having magnitude: e= 1 * Z* I 2 Where, e= voltage induced Z= Surge impedance I = current III. ASSUMPTION OF DATA In lightning surge studies many simplified assumptions are made since the waveshape and amplitude of the current source represents the lightning stroke which is obviously not well known. Lightning wave assumed (as per IEEE Standard, 1947)1.2/50 µsec with 30 K Amp of current magnitude. Inductance of surge arrester lead was assumed 0.001 mh. Wave speed are approximately equal to speed of the light with surge impedance in phase quantities. Only six spans near to surge arrester assumed with different span lengths, reflections from the other section whose surge impedance assumed to be 37.6 Ω and 300.0 Ω. Six spans of 11 KV & tower no ranging from Po to P6 is taken. Travel time is the min time taken by the wave to travel between two node and 10% of shortest travel time for o/p time scale is supposed so that better o/p is obtained from analytical point of view. It is very important to know that electrically which section is treated as one span for lightning stroke but mechanical supports are supposed at different intervals. Surge impedance on 11 KV line are calculated for conductor type Panther. Input data required to calculate the surge impedance on MATLAB. Data Input for Panther type of conductor: S.No Conductor Type Diameter of conductor Resistance at ambient temp Height of conductor at pole Height of conductor from ground in mid span Tower footing resistance 1. Panther 21.0 0.1363 9.448 m 9.144m 0.5 Ω Available online @ www.ijntse.com 2

IV. CASE STUDY Following two cases were selected, in which location for lightning is same, the only difference is that in one case surge arrester is enabled whereas in another case surge arrester is disabled. By analyzing both the cases, the importance of surge arrester can be determined. Case No.1. Lightning stroke striking on conductor [Panther] away from substation and surge arrester is not enabled. Case No.2. Lightning stroke striking on conductor [Panther] away from substation and surge arrester is enabled. Surge protection has been a primary concern when connecting devices and equipment to low, medium, or high-voltage electrical systems. As the use of products and equipment with components and insulation systems vulnerable to voltage surges and spikes continues to increase, the requirement for surge arresters to protect against the effects due to lightning strikes, switching phenomenon, etc., continues to increase as well. From personal computers to HV transmission and distribution systems, everything is susceptible to these surges and their destructive effects. This Arrester facts is about the switching surge from an arrester perspective. This text does not try to add any new data to the vast knowledge database on switching, but is an overview of the effect switching surges have on the power systems and how arresters mitigate that effect. Surge arrester being defined as: A protective device for limiting surge voltages by discharging or bypassing surge current, and it also prevents the flow of follow current while remaining capable of repeating these functions. The switching surge comes in many different forms, and has many different sources. Classifications Of surge arresters: Originally, there were three types of surge arresters. They are: 1. Expulsion type 2. Nonlinear resistor type with gaps (currently silicone-carbide gap type) 3. Gapless metal-oxide type. There are four classifications of surge arresters. They are: 1. Station class 2. Intermediate class 3. Distribution class (heavy, normal, and light duty) 4. Secondary class (for voltages 999V or less) Of the three types noted above, the expulsion types are no longer being used. The nonlinear resistor type with gaps was utilized through the middle of the 1970s and is currently being phased out. The conventional gap type with silicone-carbide blocks/discs are still being used and the gapless metal-oxide type are the most widely used today. Secondary class is not addressed in this article. Station class: With respect to the four classes of surge arresters, the station class surge arrester is the best because of its cost and overall protective quality and durability. It has the lowest (best) available protection level and energy discharging capability with successively higher (poorer) protection levels for the other classifications. Station class arresters are designed for protection of equipment that may be exposed to Available online @ www.ijntse.com 3

significant energy due to line switching surges and at locations where significant fault current is available. They have superior electrical performance because their energy absorption capabilities are greater, the discharge voltages (protective levels) are lower and the pressure relief is greater. The value of the protected equipment and the importance of uninterrupted service generally warrant the use of station class arresters throughout their voltage range. Industry standards dictate the use of both station class and intermediate class arresters for equipment protection in the 5-to 20-mVA size ranges. Above 20mVA, station class arresters are predominately used. Intermediate class: Intermediate class arresters are designed to provide economic and reliable protection of medium voltage class power equipment. Intermediate arresters are an excellent choice for the protection of dry-type transformers, for use in switching and sectionalizing equipment and for the protection of URD cables. Traditional applications include equipment protection in the range of 1 to 20 mva for substations and rotating machines. Distribution class (heavy, normal, and light duty): Distribution class arresters are frequently used for smaller liquid-filled and dry-type transformers 1000 kva and less. These arresters can also be used, if available in the proper voltage rating, for application at the terminals of rotating machines below 1000 kva. The distribution arrester is often used out on exposed lines that are directly connected to rotating machines. As noted above, the distribution class has several duty ratings, which are dependent upon the test severity. Heavy-duty arresters are more durable and have lower protective characteristics. The housing/enclosure construction of surge arresters can be of either polymer or porcelain. All of the system parameters need to be considered while choosing an arrester classification. If the actual arrester energy duties are not known and a transient study cannot be performed, then it is suggested that Station class arresters be applied. This is a conservative approach that reduces the chances of misapplication Gapless metal-oxide surge arrester (MOSA), provides the best performance and reliability. Both the gap and gapless type arresters do the same job and the selection and application process of both types are similar. However, the need to select higher voltage levels for the silicone-carbide gap type and the possibility of contamination of the gap means the protection and reliability is slightly less. When gapped type arresters fail, they are replaced by the metal-oxide gapless type. V. RESULTS Case No.1. Lightning stroke striking on conductor [Panther] away from substation without surge arrester. Circuit Diagram Available online @ www.ijntse.com 4

Fault voltage & fault current of case 1 Case No.2. Lightning stroke striking on conductor [Panther] away from substation and surge arrester is enabled. Circuit Diagram Available online @ www.ijntse.com 5

VI. CONCLUSION Unlike the lightning surge, the switching surge is generally self-induced by the operation of a breaker, switch or disconnect switch. However switching surges can be associated with lightning if during a lightning storm a lightning surge causes a breaker to operate and a switching surge is induced. The wave shape is very complex. The amplitude of this switching surge is about 2.5pu which is a quite common amplitude for switching surges. Also note the duration of this event is not much more than one power frequency cycle which again is quite common in switching surge events. Hence, after analyzing Case 1 & Case 2, finally conclusion is reached that in order to reduce the effect of lightning surge arrester must be enabled as induced voltage gets effectively reduced due to it. REFERENCES [1] Electrical Power Transmission System Engineering, Analysis and Design by Turan Gonen- California State University, Sacramento, California. [2] Extra High Voltage AC Transmission engineering by Rakoshi Das Begamudre Formerly visiting professor Indian Institute of Technology, Kanpur, India[ pp 467,463] [3] A simplified method for estimating lightning performance on overhead lines IEE Transactions on Power delivery volume PAS-104, NO.4 April 1985. [4] P. Chowdhuri, Analysis of Lightning Induced Voltages on overhead lines IEEE Transactions on Power delivery volume 4, NO.1 [pp 479-492] January 1989. [5] Standard Handbook for Electrical Engineers 13 th Edition Mc Grawhill International Editions by Donald.G.Fink and H.wayne Beaty [ pp 27-66 to 27-69]. [6] TORRES H., "Variation of lightning parameter magnitudes within space and time". Personal communication. May. 1998. [7] H.Yi and J.L.Cui, The present state and lightning protection of transmission line in China, High Voltage Engineering Vol 27 no.6,pp 44-50, December 2001. [8] X.H.Guo, Z.Q.Li and G.J.Qian, New measure of lightning shielding of transmission lines, High Voltage Engineering Vol.31,pp 37-38,July 2005. [9] W.H.Lu and X.D.Huang, Calculation methods of lightning conductor protective range. Guangdong Electric power Vol. 18. pp 64-67.March 2005. [10] G.Z.Guan High Voltage Engineering Basis Beijing China Power press,2003. [11] J.A.Martinez, F.Gonzalez and P.Chowdhuri, Calculation of lightning flashover rates on overhead transmission lines-a comparative study IEEE PES 2000 Summer Meeting, July 16-20, Seattle. [12] Xingjia Tang, Xishan Wen, Experiment and research of a new lightning protection measure IEEE PES 2008,Nov 9-13,pp 176-179. [13] Effect of lightning stroke current parameter s on the components of lightning generated vertical electric fields over finitely conducting earth by M.Z.I Sarkar, M.A.I. Sarkar ICECE 2008,20-22 December 2008,pp 43-48. BIOGRAPHY Swati Agrawal received BE degree in Electrical Engineering from Pt Ravi Shankar Shukla University in the year 2006. She has completed her M.E (by Research) from Yashwant Rao Chavan College of Engineering, Nagpur University. Since 2007, she is working with MATS University, Raipur (C.G).Her area of interested is high voltage, power electronics. Email id:swatiagrawal21@yahoo.co.in Available online @ www.ijntse.com 6