Installation guide 873 SmartRadar Control Unit & Antenna Unit

Similar documents
Installation guide 971 SmartRadar LTi

Installation guide 877 FDI Field Display & Interface

Installation guide 970 SmartRadar ATi

Installation guide 854 XTG Level Gauge

Installation guide 970, 971 and 973 series SmartRadar

Installation Guide dedicated O-ring for demanding chemicals applications with 854 ATG

Installation guide Roof reflector

2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER

Servo Gauge 854 XTG. Global Experience. Locally Applied. Cut costs, not repeatability.

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

ENRAF SERVO GAUGE 854 ATG Setting the standard in gauging.

VITO LT. Global Experience. Locally Applied. A dependable choice.

OPTIWAVE 7300 C Supplementary instructions

INSTRUCTION MANUAL (ATEX / IECEx)

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

SET Installation and Operating Instructions. Level switch for two sensors

Mid-West. Instrument. Model 140 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL

Rosemount 5408 and 5408:SIS Level Transmitters

Instruction manual 970 SmartRadar ATi

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

Process display RIA 261

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Rosemount 5600 Series Radar Level Transmitter with HART and Foundation fieldbus protocol

KENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents

Specifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift

IP26 Series Current to Pneumatic Converter

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

User's Manual Model SE14 Magnetic Flow Converter

Head mounted Temperature Transmitter TF02/TF02-Ex

Sarasota CM200 Sarasota HME900 Density Converter Electronics

Submersible pressure sensor For oils and fuels Model LF-1

ATEX Installation Drawings and Instructions

MANUAL HYDROBAR. Manufactured by: Fax: H/US/Hydrobar/ /00 Klay Instruments Page 1

1-830 SERIES DISPLACEMENT TRANSMITTER

IT6810/IT6811/IT6812 IMPACT TRANSMITTER Installation Manual

Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H

Installation instructions Dec. 2002

GENERAL PURPOSE INDICATOR LOOP POWERED WITH VERY LARGE DIGITS DATASHEET F090 - GENERAL PURPOSE INDICATOR

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

Temperature Input Module for Zone 1 Series 9482/32

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique

Indicomp 2, Indicomp 2-Ex. Indicator and alarm signalling unit 10/ EN

Rosemount 5400 Series Radar Level Transmitter

Rosemount TGU 65 Tank Radar Gauge, Still Pipe Antenna

Submersible pressure sensor For superior applications Model LF-1

R88000 T (including ATEX)

Safety Instructions Nivotester FTC625, FTC325

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Transducer transmitter BILT 4 II 2(1) G. Technical Manual

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

LST400 Ultrasonic level / open channel flow transmitter

Level Measurement Continuous level measurement Radar transmitters

Instruction manual 862 MIR Multiple temperature selector with MPU, HPU or OPU board

SALES SERVICE +358 (0)

Level Measurement silometer FMX 570

Installation Instructions P/N MMI , Rev. AA July ATEX Installation Instructions for Micro Motion Model RFT9739 Transmitters

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

Field indicator for current loops with HART communication Models DIH50, DIH52

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

INSTALLATION AND OPERATION MANUAL

Page Type Resolution (mm) min. max. Output

Loop Powered Indicator

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Level Limit Switch nivotester FTL 325 P

PROline promag 53 Division 1

FLEX Ex Power Supplies

INTRINSIC SAFETY BASIC PRINCIPLES

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

Resistance Thermometers Model Series TR7X0, Sheathed Design

Rosemount 3101, 3102, and 3105

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Solexy USA, LLC International Blvd Cincinnati, Ohio Phone: Fax:

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

Rod probe With coaxial tube reference probe

Positioner with HART Communication Type 3780

Monocrystalline silicon smart differential pressure transmitter. High stability. Benefits. application DRS

Technical Information RMA42

Submersible pressure sensor For water and wastewater Model LW-1

RMA42. Technical Information

Overtravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0

Weighing Instruments

PRetrans Table of contents

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Installation Instructions P/N MMI , Rev. AA July ATEX Installation Instructions for Micro Motion Model 3500 Transmitters

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

MANUAL HYDROBAR. Manufactured by: 7991 CZ DWINGELOO 7990 AA DWINGELOO The Netherlands

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Isolators A3/1. Vibration Transducer Supply Unit Series

Level Measurement. Continuous level measurement Radar transmitters SITRANS LR460. 4/258 Siemens FI

Operating Instructions

VTM Local Display Unit with Frequency and Analogue Output

Transcription:

Installation guide 873 SmartRadar Control Unit & Antenna Unit Rev. 7 January 2006 Part no. 4416.569 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : info@enraf.nl Website : http://www.enraf.com Installation guide 873 SmartRadar Control Unit & Antenna Unit Page 1

Preface Preface The 873 SmartRadar is a radar-based level gauge for liquid storage tanks. This installation guide is intended for technicians involved in the mechanical and electrical installation of the Enraf series 873 SmartRadar Control Unit and Antenna Unit. EC declaration of conformity Refer to the EC declaration of conformity, shipped with the instrument. All connections to the instrument must be made with shielded cables with exception of the mains, alarm outputs and Enraf field bus cable. The shielding must be grounded in the cable gland on both ends of the cable. Legal aspects The mechanical and electrical installation shall only be carried out by trained personnel with knowledge of the requirements for installation of explosion-proof equipment in hazardous areas. The information in this installation guide is the copyright property of Enraf BV, Netherlands. Enraf BV disclaims any responsibility for personal injury or damage to equipment caused by: Deviation from any of the prescribed procedures; Execution of activities that are not prescribed; Neglect of the general safety precautions for handling tools and use of electricity. The contents, descriptions and specifications in this installation guide are subject to change without notice. Enraf BV accepts no responsibility for any errors that may appear in this installation guide. Additional information Please do not hesitate to contact Enraf or its representative if you require additional information. Page 2

Safety Safety Safety aspects of 873 SmartRadar Warning Do not use the instrument for anything else than its intended purpose. The housing of the 873 SmartRadar is explosion-proof: II 1/2 G EEx de [ib/ia] IIB T6; KEMA 02ATEX2301 X, certified by KEMA, Netherlands. Class I, Division 1, Groups B, C & D according to ANSI/NFPA, certified by Factory Mutual Research Company (FM no.: 2Z5A6.AE). Environmental conditions for the 873 SmartRadar are: ambient temperature : -40 to 65 C (-40 to 149 F) operating pressure : atmospheric for RoD antenna max. 6 bar for F06, F08, S06.. S12, W06 and T06 antennas max. 20 bar for H02 antenna max. 40 bar for H04 antenna relative humidity : 0-100 % ingress protection : IP65 (NEMA4), suitable for outdoor installation The covers of Antenna Unit and Control Unit are provided with blocking facilities which prevent unauthorised opening. The Control Unit has two separate cable entries for intrinsically safe options. Warning Improper installation of cable glands, conduits or stopping plugs will invalidate the Ex approval of the SmartRadar. The emitted microwave energy is far below acceptable limits for exposure to human body. 2 Depending on the type of antenna, a maximum radiation of 0.03 mw/cm is generated. Installation guide 873 SmartRadar Control Unit & Antenna Unit Page 3

Safety Personal safety The technician must have basic technical skills to be able to safely install the equipment. When the 873 SmartRadar is installed in a hazardous area, the technician must work in accordance with the (local) requirements for electrical equipment in hazardous areas. Warning In hazardous areas it is compulsory to use personal protection and safety gear such as: hard hat, fire-resistive overall, safety shoes, safety glasses and working gloves. Avoid possible generation of static electricity. Use non-sparking tools and explosion-proof testers. Make sure no dangerous quantities of combustible gas mixtures are present in the working area. Never start working before the work permit has been signed by all parties. Pay attention to the kind of product in the tank. If any danger for health, wear a gas mask and take all necessary precautions. Safety conventions Warnings, Cautions and Notes are used throughout this installation guide to bring special matters to the immediate attention of the reader. A Warning concerns danger to the safety of the technician or user; A Caution draws the attention to an action which may damage the equipment; A Note points out a statement deserving more emphasis than the general text, but not requiring a Warning or a Caution. Page 4

Mechanical installation Mechanical installation The entire installation procedure shall be in accordance with national, local and company regulations. Mechanical installation Control Unit The installation of the Control Unit is common for all antenna types. The Control Unit can be installed on or next to the tank. Maximum distance from Antenna Unit: 150 m (500 ft). Place Control Unit against a vertical mounting plate (or other suitable place). Minimum size for the mounting plate is: 230 mm (9") height by 140 mm (5½ ) width. Weight of Control Unit is 14 kg (31 lbs). Refer to appendix A for dimensions of Control Unit and drilling plan of mounting holes. Figure 1 gives an example of the Control Unit installation. Figure 1 Control Unit on mounting plate Leave sufficient space for the infra red connector at the bottom left side of the Control Unit and for removal of the front and rear cover. Refer to the dimensional drawing of the Control Unit in appendix A. Caution The Control Unit, its mounting plate and the Antenna Unit must have the same ground reference (grounded to the tank). Installation guide 873 SmartRadar Control Unit & Antenna Unit Page 5

Mechanical installation Mechanical installation Antenna Unit The installation is common for all Antenna types. Refer to appendix A for the dimensions of the Antenna Unit. Antenna and tank separator should already be installed (refer to installation guide SmartRadar antennas). Install Antenna Unit on the tank separator as follows: 1) Place Antenna Unit on tank separator; mind locking pin! 2) Turn coupling nut manually securing the Antenna Unit Figure 2 H04 tank separator The H04 tank separator has two locking pin holes. Position Antenna Unit so that the locking pin of the Antenna Unit is placed in the locking pin hole which is 90 away from the vent plug (figure 2). Caution The Antenna Unit and Control Unit must have the same ground reference (grounded to the tank). Page 6

Electrical installation Electrical installation The entire electrical installation shall be in accordance with the International Standard IEC 79-14 for electrical equipment to be installed in hazardous areas. Warning Make sure that all power to the instrument is switched off before opening the covers of the 873 SmartRadar. Failure to do so may cause danger to persons or damage the equipment. All covers of the 873 SmartRadar (Control Unit and Antenna Unit) must be closed before switching on the power. Caution Before opening the covers of the Control Unit, make sure that the blocking devices ( A for the front cover and B for the rear cover) are removed (figure 3). Use Allen key 3 mm. Figure 3 Blocking / sealing facilities Caution Do not damage the thread of covers and the Control Unit and Antenna Unit and keep the thread free of dirt. After opening, grease it lightly with anti seize grease. When closing, never tighten the covers before the threads are properly engaged. The covers should be turned counter-clockwise until the thread clicks in place, then turn clockwise until the covers are fully closed. After closing the covers, do not forget to place the blocking devices. Installation guide 873 SmartRadar Control Unit & Antenna Unit Page 7

Electrical installation Preparing SmartRadar for electrical installation Mains voltage selector Check whether voltage selector is set correctly as indicated on identification label of Control Unit as well as for the presented supply. The voltage selector is located inside electronic compartment at top of the backplane (figure 4). The Control Unit operates on a mains voltage of 110, 130, 220 (+10% to -20%) and 230 Vac (±15%). A special 65 Vac (+10% to -20%) is available. Power rating: 25 VA; frequency: 50 to 60 Hz (±10%); I = 2 A. max Install an explosion-proof mains switch in the mains supply cable to each Control Unit. Specify which switch you need to operate the SmartRadar Control Unit. For 240 V supply voltage, set voltage selector to 230 V. Supply voltage may then vary +10% to -20%. To change the voltage setting, proceed as follows: Figure 4 Voltage selector 1) Check the local mains voltage 2) Open front cover of Control Unit 3) If necessary, change voltage selector to applicable voltage: remove mains supply indication plate slide switch in appropriate position (figure 4) place mains supply indication plate and lock it 4) Close front cover Caution Changes of the mains setting shall be marked on the identification label of the Control Unit. Page 8

Electrical installation External fuses The 873 SmartRadar Control Unit is internally fused on secondary side of the transformer (fuses are located on GPS board). Therefore, external fuses must be installed in the mains supply cable to each Control Unit. Mains voltage Fuse value (in accordance with IEC 127-2-3) 220 / 230 Vac 315 ma slow 110 / 130 Vac 630 ma slow 65 Vac 1 A slow Grounding The Control Unit and Antenna Unit should be properly grounded to the ground reference (generally the tank). This is a safety grounding requirement. For this purpose, the Control Unit and Antenna Unit have external ground terminals. Caution Antenna Unit and Control Unit must have the same ground reference. Caution Safety depends on proper grounding. Check the resistance of the ground connection directly after installation. The measured ground resistance shall be below the maximum prescribed by local grounding requirements. Warning When measuring the ground resistance, use a suitable explosion-proof tester. Grounding shall be performed in accordance with local regulations. Installation guide 873 SmartRadar Control Unit & Antenna Unit Page 9

Electrical installation Cable glands / conduit Cable glands: Explosion-proof (Ex-d) or increased safe (Ex-e) cable glands must be used, depending on local requirements. Refer to the Ex-marking on the identification label of the Control Unit to determine which type of cable gland is required. Mount the glands according to the supplier s instructions. Conduit: If the SmartRadar is installed in a hazardous area, threaded rigid metal conduit or threaded steel intermediate metal conduit shall be used. If the SmartRadar is installed in a hazardous area, stopper boxes must be applied within 18 inches (0.45 m) from the Antenna Unit and Control Unit to seal the cabling in the conduits. Depending on the wiring configuration, two or more ¾ NPT threaded cable glands (or rigid conduits) may be required with the Control Unit. The Antenna Unit requires a (flexible) conduit with one ½ NPT connection at the Antenna Unit side. The length of the flying leads from the Antenna Unit is 4 metres (13 ft). If the Control Unit is located within this distance, a direct connection can be made between Antenna Unit and Control Unit. If the distance is longer, a junction box and a separate four-core cable is required. The optional Enraf installation kit contains a flexible conduit (1 m) with ½ NPT connections and an Ex-e junction box with ¾ NPT cable entry (refer to appendix A). Figure 5 Cable entries at Control Unit Page 10

Electrical installation Seal the unused cable inlets with an approved ¾ NPT threaded stopping plug. Warning Improper installation of cable glands, conduit or stopping plugs will invalidate the Ex approval of the 873 SmartRadar. Non-intrinsically safe cabling The terminal compartment of the Control Unit is divided in a non-intrinsically safe part and an intrinsically safe part. Cable entries are all ¾ NPT. The non-intrinsically safe cabling may only enter at the centre and two right hand side cable entries (figure 6). Warning Only open the terminal compartment cover (rear cover) when the power is switched off. Figure 6 Terminal compartment Control Unit Installation guide 873 SmartRadar Control Unit & Antenna Unit Page 11

Electrical installation Non-intrinsically safe connections Mains cabling : Must be suitable for 873 SmartRadar power ratings and, moreover, approved for use in hazardous areas. Enraf field bus : One twisted pair cable is recommended. R max = 200 Ω / line; C max = 1 µf. Maximum distance: 10 km. Enraf field bus lines may be interchanged. If local regulations allow, mains and Enraf field bus lines may share one cable. Mind the isolation voltage of the cores in the cable; refer to the International Standard IEC 61010-1. If a quad cable is used and all four cores are twisted together, use two opposite cores for Enraf field bus lines and the two others for mains. AU cabling : Flying leads must be run in a (flexible) conduit, which gives EMC protection. For longer connections than the 4 metres of flying leads: Maximum length: 150 m (500 ft); twisted pairs and shielded; R max = 2.5 Ω / line; C max = 15 nf. Relay outputs : Option. The relay contacts are potential free. Contact rating: U max = 50 Vac or 75 Vdc; I max = 3 A non-inductive (CSA only: 0.6 A). Mind the isolation voltage of the cores in the cable; refer to the International Standard IEC 61010-1. Analog output : Option. Use shielded cable External supply voltage: minimum: 12 Vdc; maximum 64 Vdc (figure 8). Page 12

Electrical installation Figure 7 Non-intrinsically safe connections When the supply voltage exceeds 30 Vdc, an additional resistor is required. The permitted operational areas are shown in figure 8. Operational area 1 represents the area of operation without the need for an external loop resistance. Operational area 2 shows the area where a resistance is required. The power rating of the external resistor depends on the value of the resistor. We recommend: 1 W / kω. Figure 8 Selecting external loop resistor Installation guide 873 SmartRadar Control Unit & Antenna Unit Page 13

Electrical installation Optional RS communication connections For the mains, Antenna Unit and optional relay output cabling, refer to previous section. Caution Keep the RS-232C / RS-485 lines as short as possible. RS-232C : Option. Cable: maximum length 15 m (50 ft); twisted and shielded. RS-485 : Option. Cable: maximum length 1200 m (3900 ft); twisted and shielded. Figure 9 RS-232C or RS-485 connections Page 14

Electrical installation Intrinsically safe connections The cables for the intrinsically safe option(s) shall only be fed through the cable entries at the side of the intrinsically safe (blue) terminals. Blue marked cables are recommended for the intrinsically safe options. Caution The intrinsically safe options described in this section are explosion-proof certified. Make sure that the certificate of approval is available on site and act in accordance with the instructions as given in the approval certificate. Caution Intrinsically safe wiring shall be separated from all other wiring. Cable lay-out shall be in accordance with local regulations. The shield of the intrinsically safe cable shall not be connected inside the Control Unit housing. Connect the shield of the cable externally in the cable gland at both ends of the cable. Device Cable requirements Spot temperature element : Shielded; R = 12 Ω / line. max Average temp. element : Twisted pair and shielded; R max = 25 Ω / line. (combined water probe) Wiring between Control Unit and 762 VITO must be protected with EMC shielded conduit. Same conditions for connection to 862 MIR Pressure transmitters : Twisted pair and shielded; R max = 25 Ω / line (only pressure transmitters with HART protocol). Pressure transmitter P1 is the bottom transmitter (measures liquid head) and P3 is the top transmitter (measures vapour pressure). Water bottom probe : Twisted pair and shielded; R max = 25 Ω / line. (no VITO water sensor) (only with HART protocol). If pressure transmitters are also connected, use a junction box for the parallel connection of the pressure transmitters and water bottom probe. Installation guide 873 SmartRadar Control Unit & Antenna Unit Page 15

Electrical installation + Water bottom probe - + P3 - + P1 - + - HART input 2 - + + - HART input 1 - + - + 762 VITO Interface A B C Spot temperature element A C B RTD 1 2 3 9 4 5 6 11 1 2 3 9 4 5 6 Figure 10 Intrinsically safe connections with HCU option board If pressure transmitters are connected to HART input 2, it must be verified that the maximum values for current and power of the HCU option board HART input 2 circuit are not exceeding the maximum values of the connected pressure transmitters. Refer to Appendix B. If the values of the HART input 2 circuit are too high, then connect the pressure transmitters to HART input 1 and the 762 VITO Interface to HART input 2 (only possible when HART input 1 is available). Page 16

Electrical installation + Water bottom probe - + P3 - + P1 - + - HART input - + + - 862 MIR + - To 862 MIR 1 2 3 9 4 5 6 11 1 2 3 9 4 5 6 Figure 11 Intrinsically safe connections with MPU-3 / HPU option board Installation guide 873 SmartRadar Control Unit & Antenna Unit Page 17

Appendix Appendix A Dimensional drawing 873 SmartRadar Control Unit Page 18

Appendix 873 SmartRadar Antenna Unit Installation guide 873 SmartRadar Control Unit & Antenna Unit Page 19

Appendix Terminal detail n 1 AKZ.4PX numbered 1413 12 11 SmartRadar Antenna Unit 1112 1314 Mounting holes ø6.5 (4x) Flexible conduit, length 1 m. with couplings ½" NPT 74 90 75 90 30 873 SmartRadar installation kit ø 20 ± 0.5 Page 20

Appendix Appendix B ATEX Approval The terminal compartment of the 873 Control Unit has been ATEX approved as explosion-proof and as being increased safe. The type of cable glands that must be used: For protection type increased safe EEx e approved glands are to be used. For protection type explosion proof EEx d approved glands or conduit are to be used. Connection requirements of optional boards The identification label on the Control Unit indicates whether your instrument is equipped with an optional board with intrinsically safe measuring circuits. HCU option board, [EEx ia] IIB Spot temperature input circuit: Max. values : U = 23.1 V; I = 221 ma; P = 0.19 W Max. permissible ext. inductance : 3.5 mh Max. permissible ext. capacitance : 980 nf HART input 1 circuit (for 762 VITO Interface): Max. values : U = 23.1 V; I = 90 ma; P = 0.52 W Max. permissible ext. inductance : 15 mh Max. permissible ext. capacitance : 1.02 µf HART input 2 circuit (for HART pressure transmitters and/or external water probe): Max. values : U = 23.1 V; I = 148 ma; P = 0.86 W Max. permissible ext. inductance : 7 mh Max. permissible ext. capacitance : 1.02 µf MPU-3 option board, [EEx ib] IIB 862 MIR input circuit: Max. values : U = 21 V; I = 231 ma; P = 0.88 W Max. permissible ext. inductance : 3 mh Max. permissible ext. capacitance : 1.27 µf Installation guide 873 SmartRadar Control Unit & Antenna Unit Page 21

Appendix HPU option board, [EEx ib] IIB 862 MIR input circuit: Max. values : U = 21 V; I = 221 ma; P = 0.86 W Max. permissible ext. inductance : 3 mh Max. permissible ext. capacitance : 1.27 µf HPU option board, [EEx ia] IIB HART input circuit (for HART pressure transmitters and/or external water probe): Max. values : U = 21 V; I = 148 ma; P = 0.72 W Max. permissible ext. inductance : 6 mh Max. permissible ext. capacitance : 1.27 µf Page 22

Appendix Appendix C Related publications Installation guide 873 SmartRadar Antennas Instruction manual 873 SmartRadar Instruction manual APU Hard alarm output contacts Instruction manual SmartRadar verification pin compensation Installation guide 762 VITO Interface & 764, 765 or 766 VITO temperature and/or water sensor Instruction manual XPU-2 option RS-232C/RS-485 Instruction manual Temperature, Water bottom and Analog output options Instruction manual HIMS / HTG and vapour pressure (P3) measurement Instruction manual 847 PET Installation Info 003 (Installation HIMS systems) Identification code 873 SmartRadar Installation guide 873 SmartRadar Control Unit & Antenna Unit Page 23

Page 24