SECTION MECHANICAL IDENTIFICATION

Similar documents
Piping & Equipment Identification

CSP PSYCHIATRIC SERVICES UNIT SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

SECTION IDENTIFICATION FOR HVAC PIPING, DUCTWORK AND EQUIPMENT

SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

SECTION IDENTIFICATION OF PLUMBING, PIPING AND EQUIPMENT. A. Section includes nameplates, tags, stencils and pipe markers.

B. Samples: For color, letter style, and graphic representation required for each identification material and device.

SECTION IDENTIFICATION OF HVAC PIPING AND EQUIPMENT. A. Section includes nameplates, tags, stencils and pipe markers.

Excavating, Backfilling, and Compaction for Utilities Piping (Plumbing).

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

SECTION IDENTIFICATION FOR PLUMBING PIPING AND EQUIPMENT

SECTION MECHANICAL IDENTIFICATION

SECTION MECHANICAL IDENTIFICATION. 1. Identification of mechanical products installed under Division 15.

SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

SECTION MECHANICAL IDENTIFICATION

Industrial Pipe Marking

SECTION MECHANICAL IDENTIFICATION

1. ASME A Scheme for the Identification of Piping Systems.

PART 0 DESIGN STANDARDS 0.01 GENERAL DESIGN GUIDELINES

SECTION IDENTIFICATION FOR FIRE SUPPRESSION PIPING AND EQUIPMENT

PROJECT TITLE PROJECT NO: CONTRACT TITLE GRANT NO: UNIVERSITY OF CALIFORNIA, DAVIS CITY, CALIFORNIA

SECTION MECHANICAL IDENTIFICATION. 1. Identification of mechanical products installed under Division 15.

SECTION COMMON WORK RESULTS FOR HVAC

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2017

A. Product Data: For each electrical identification product indicated.

IDENTIFICATION DEPOT, INC. 206 East Second Street Washington, NC PHONE FAX

SECTION ELECTRICAL IDENTIFICATION

A. Radius elbows with a construction radius of 1.5 the duct width are preferred to square elbows.

PRESTON HEALTH SERVICES ARCHITECT S NO. 2700

SECTION IDENTIFICATION DEVICES

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section ELECTRICAL IDENTIFICATION

Facility Services Subgroup Preface for Divisions 21` through 28

Page PRODUCT DESCRIPTION

SECTION ELECTRICAL IDENTIFICATION

Part VIII Electrical GENERAL REQUIREMENTS CHAPTER 33

A. It is preferred that all submittals to be submitted electronically in PDF format.

Page PRODUCT DESCRIPTION

SECTION 10520: FIRE EXTINGUISHERS AND CABINETS

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE

AMPCO PRODUCTS, INC. TECHNICAL SPECIFICATIONS SOLID PHENOLIC CORE TOILET COMPARTMENTS

FIRE STATION NO TH STREET NORTH ST. PETERSBURG, FL M-1 SCOPE OF WORK SYMBOL DESCRIPTION SYMBOL DESCRIPTION HVAC SYMBOL LEGEND

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

MECHANICAL GENERAL REQUIREMENTS SECTION B. The requirements of this SECTION apply to all work of this DIVISION.

SECTION SIGNAGE

SECTION IDENTIFICATION FOR ELECTRONIC SAFETY AND SECURITY

Residential Construction Checklist Single and Two Family Construction

SECTION LOW PRESSURE DUCTWORK

The School District of Palm Beach County Project Name SDPBC Project No. SECTION ( ) SIGNAGE PART 1 GENERAL 1.1 RELATED DOCUMENTS

A. Submit properly identified manufacturer's literature before starting work.

*********************************************************************************************************

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Address: South Elgin, IL Phone: ( ) - Fax: ( ) - Cell: ( ) - Contractor Type: Phone: ( ) - Fax: ( ) - Cell: ( ) - Contact Type:

University of Houston Master Construction Specifications Insert Project Name SECTION MECHANICAL SCOPE OF WORK PART 1 - GENERAL

SECTION IDENTIFYING DEVICES

UNIFIED FACILITIES GUIDE SPECIFICATIONS

A. This Section includes plumbing fixtures and related components.

SECTION Display Case Door Series 1301-CM

D. Thermally Sprayed Metallic Coating (Flame Spray): STD SPEC

SECTION WIREWAYS FOR RADIOLOGY EQUIPMENT

DIVISION 11 EQUIPMENT SECTION PHOTO DARKROOM FUME EXHAUST VENT-HOODS

SECTION CABLE TRAYS FOR ELECTRONIC SAFETY AND SECURITY

New Product Release: October 2014 Boone Racks

Ductwork Controls and Instrumentation Outlets (HVAC) HVAC Control System.

Model ABV Pressure Independent Automatic Balancing Valve. Application: Standard Construction: Performance: Configurations Available:

SECTION CONCRETE REINFORCEMENT FOR STEAM UTILITY DISTRIBUTION

GRICE-TRIVERS JOINT VENTURE ARCHITECTS PAGE 1 PROJECT NO

SECTION INTERIOR SIGNAGE

B. Division-16 Basic Materials and Methods section apply to work specified in this section.

Round Duct and Fittings. Standards and Dimensional Data for Air Duct and Fittings

Design and Construction Standards SECTION ATHLETIC LOCKERS

1. State that all workmanship must conform to all pertinent laws, ordinances and regulations of all bodies having jurisdiction.

FLUOROPOLYMER COATED DUCT FOR CAUSTIC ENVIRONMENTS

SECTION CABLE TRAYS

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PRESSURE GAUGES, Section 15130

UNIFIED FACILITIES GUIDE SPECIFICATIONS

PROGRAMMING SCHEMATIC DESIGN DESIGN DEVELOPMENT CONSTRUCTION DOCUMENTS. room) Scalable bubble diagrams schedules describing programmatic

C. Samples for Initial Selection: Manufacturer's color charts showing the full range of colors available.

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

Health and Safety at Work (Hazardous Substances Markings for Pipework Connected to Above Ground Stationary Tanks) Safe Work Instrument 2017

LOW PRESSURE STEEL DUCTWORK Mechanical Systems Insulation Outlets (HVAC) Testing and Balancing.

DOCUMENT ADDENDUM NO. 4. Issued to all Bidders: Date: October 14, Contract Name: Electrical Installation. Contract Number: C8410

SECTION FRAMELESS GLASS SLIDING BI-FOLD SHOWER DOOR HARDWARE

SECTION BATHROOM ACCESSORIES

SECTION BULLET- RESISTANT DOORS

Health and Safety at Work (Hazardous Substances Markings for Pipework Connected to Above Ground Stationary Tanks) Safe Work Instrument 2017

Union County Vocational - Technical Schools Scotch Plains, New Jersey

PROJECT INSTRUCTIONS Roofing

2. All work and materials shall be in full accordance with Local and State ordinance and with any prevailing rules and regulations.

WEST HOLLYWOOD ACCESSIBLE UNISEX BATHROOMS: COMMERCIAL CLEARANCES. Accessible Unisex Bathrooms: Commercial Page 1 of 5

SCI-FAB Product Specifications. Casework Section 1. Part 1 General

.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1.

METAL METAL

INSTALLATION INSTRUCTIONS SIDELITE ASSEMBLY SERIES 900 TERRACE DOOR AND SERIES 925 PATIO DOOR

SECTION SUBMITTALS. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

CHAPTER 6 DUCT SYSTEMS

SECTION NON-ILLUMINATED INTERIOR DISPLAY SYSTEM

SECTION PAINTS AND COATINGS

Series 6000 Vinyl Single Hung

ADDENDUM NO. 1 TO THE CONTRACT DOCUMENTS AND SPECIFICATIONS DATED JULY 2017 FLORIDA GOVERNMENTAL UTILITY AUTHORITY PROJECT NO.

FUEL GAS PIPING SECTION A. The provisions of SECTION 15010, MECHANICAL GENERAL REQUIREMENTS, apply to this section.

Transcription:

SECTION 15190 MECHANICAL IDENTIFICATION PART 1 GENERAL 1.01 SECTION INCLUDES A. Section Includes: 1. Nameplates. 2. Tags. 3. Stencils. 4. Pipe Markers. 1.02 SUBMITTALS A. Submit valve chart and schedule, including valve tag number, location, function, and valve manufacturer's name and model number. PART 2 PRODUCTS 2.01 MANUFACTURERS A. Seton Nameplate Corporation. B. Or equal. 2.02 IDENTIFICATION A. Comply with ASME A13.1-1975. B. Access Tile Identification. 1. Buttons, tabs, and markers: to identify location of concealed work. 2. Submit for review. C. Valve Tags: 1. Minimum 2 in. diameter. 2. Engraved plastic; Seton Setonply Series 2961, or equal. 3. Identifying number and system letter. a. Per design documents. 4. Different patterns (circular, square, etc.) for: a. HVAC. b. Plumbing. c. Fire protection. 5. Attachment: 15190-1 November 13, 1998

a. Brass "S" hooks, beaded chain or jack chain. 6. Seton Name Plate Corporation or equal. D. Pipe Markers: 1. Factory fabricated snap-on type. a. Service legend. b. Flow arrows. 2. Weather-proof plastic coating. 3. Do not use where surface temperature exceeds 180 o F. 4. Of following types: a. Smaller than 6 in.: Setmark SNA or equal. 1) Completely encircling pipe. b. 6 in. and larger: Setmark STR or equal. 1) Stainless steel spring fasteners. 5. Adhesive type markers not permitted. E. Duct and Equipment Name plates: 1. Engraved black Lamicoid sheet with lettering. 2. Secure with chrome plated screws. 3. Inscription: Subject to review, indicating equipment and voltage. F. Valve and Piping Charts 1. Valve Charts: a. Schematic flow diagrams of each piping system indicating: 1) Location and function of each tagged valve. 2) Type, size and essential features of each system. 3) Indicate whether normally open or normally closed. 4) Submit for review. 2. Piping Identification Charts: a. List piping services and identifying symbols. b. List color coding, where applicable. 3. Charts suitably sized. 4. Glass or plastic front. 5. Provide galvanized steel, or extruded satin finish aluminum mount: a. Clear plastic front. 15190-2 November 13, 1998

b. Dust-proof frame. c. Permanently fastened in locations as directed. PART 3 EXECUTION 3.01 General A. Piping should be placed in one of the following classifications and color coded, shade as approved. This corresponds to colors on ASME Al3.1, (Scheme for Identification of Piping Systems). 1. Red for fire-protection materials. 2. Yellow or Orange for dangerous materials. 3. Green and Blue for safe materials. B. Shades shall be consistent throughout the project. C. Valves, strainer and other appurtenances operating at over 220 o F where bare metal is exposed shall be coated with Silicone Alkyd Aluminum, 7lS30. 3.02 IDENTIFICATION A. Valve Tags: 1. On all following valves, except at equipment connections: a. Domestic water and gas valves controlling mains, risers and branch runouts. b. Sprinkler and standpipe systems, except hose valves. 2. Identify fire service valves with tags reading: FIRE MAIN - DO NOT CLOSE a. Red background. b. White letters. 3. Indicate normally open or normally closed. 4. Secure to valve handwheels or stems with brass-beaded chain. B. Piping Identification. 1. Before applying identification complete testing, insulation and finish painting. 2. Identifying piping services per legend on drawings. 3. Identify all piping, bare or insulated. 4. Identify valves and piping immediately behind access panels into furred spaces. 5. Identification locations: a. Locate legends and flow arrows to be readily visible from any reasonable point of observation. b. Where two or more pipes run in parallel, place legend and other markers in same relative location. 15190-3 November 13, 1998

c. Place at eye level: along center line of pipe. d. Above eye level: on lower quarter of pipe. e. Below eye level: on upper quarter of pipe. f. Where view is unobstructed from two directions, apply two sets of stencilling (two sides) visible from each direction. g. Locate legend, flow arrow, etc: 1) At valve locations; 2) At all points where piping enters leaves partition, wall, floor or ceiling. 3) At intervals of 20 ft. on straight runs. 6. Identify piping with snap-on pipe markers as specified herein before. a. On piping under 3/4 in. outside diameter use tags similar to valve tags. 7. Identify following piping when not completely painted C. Duct Identification. a. Fire protection piping: 1) 1 in. wide red painted band encircling pipe. 2) Adjacent to symbol identifications. 1. Identify exposed ductwork in mechanical equipment rooms as follows: a. Air handling apparatus to which connected. b. Service: 1) Outside Air. 2) Relief Air. 3) Toilet Exhaust. 2. Identification Locations: a. Readily visible from normal operating level. b. At centerline of duct, close to equipment. c. If view is unobstructed from two directions apply identification on both sides of duct. 3. Use nameplates as specified above. D. Equipment Identification. 1. Identify each item of mechanical equipment. 2. Spell out complete name or use symbol on drawings. 3. Use nameplates as specified above. 4. Conform to identification in contract documents. 5. Provide for following equipment: a. Gauges. b. Meters and Instruments. c. Pilot lamps. 15190-4 November 13, 1998

d. Control devices. e. Motor controllers. f. As noted. 6. Provide manufacturer's nameplates on equipment, identifying: a. Manufacturer's name. b. Model number. c. Size. d. Capacity. e. Electrical characteristics. 7. Leave manufacturer's nameplates clean and legible. 8. Install equipment so that view of nameplates is not obstructed. a. If necessary install additional visible nameplates. E. Valve and Piping Charts. 1. Install where directed by Architect, but at least one in first floor electrical room. END OF SECTION D:\Drawings\Office org1\spec\m\sss01m19.wpd 15190-5 November 13, 1998