MAGNETIC FIELD METER Operator s Manual

Similar documents
MAGNETIC FIELD METER Operator s Manual

Exposure Level Tester ELT-400

ELECTRIC FIELD METER 200

Selective and broadband low frequency field analysis

Safety Evaluation Within a Magnetic Field Environment

Selective and broadband high frequency field analysis

Advanced Test Equipment Rentals ATEC (2832)

Continuously monitors and stores the levels of Electromagnetic fields Up to four simultaneous bands: GSM 900 / 1800 MHz / UMTS / Broadband 100 khz 3

Analysis of static and time-variable magnetic fields

UltraTEV Locator. Portable PD (Partial Discharge) investigation system. benefits. features. FACT: 85% of disruptive substation failures are PD-related

Safety Evaluation Within a Magnetic Field Environment

OVA-50 Optical Variable Attenuator User s Manual

For Isotropic Measurement of Magnetic and Electric Fields

Tender NO. PGVCL/PROC/Cable & Pipeline Locator/832

Continuous, remote monitoring and logging of electromagnetic fields

Selective and broadband low frequency field analysis

ExpoM - ELF User Manual

Instructions for Use: DSP-523 True-RMS 3 Axis DSP Gaussmeter Magnii Technologies

SAS-562B Active Loop Antenna Operation Manual

PIPELINE DEFECT MAPPER

vscan Data Sheet V1.0

The new generation More comfortable even faster more precise SmartBalancer2 Perfect field balancing made easy

Professional Dual-Laser Infrared Thermometer with 50:1 Distance-to-Sight Ratio, Data Logging, USB Output, Single Type K Input, and Temperature Alarm

Hand-held temperature calibrator Model CEP3000

Magnetic Field Meter BMM-5 user instructions

JD723A/JD724B/JD726A Cable and Antenna Analyzers

Continuous, remote monitoring and logging of electromagnetic fields

Advanced Test Equipment Rentals ATEC (2832)

SAS-563B Active Loop Antenna Operation Manual

GC723A / GC724B Cable and Antenna Analyzer

9/2/2013 Excellent ID. Operational Manual eskan SADL handheld scanner

MD-5060 DIGITAL MEGOHMMETER

Vitrek 4700 Precision High Voltage Meter

Model 7000 Low Noise Differential Preamplifier

IT-24 RigExpert. 2.4 GHz ISM Band Universal Tester. User s manual

Transformer test equipment easy to use

Mobile Activation Case

Digital Function Generator

WS-29 DUAL CHANNEL WIRELESS BELTPACK

( F L O W I Z F A M I L Y )

SPM-50 RF Spectrum Power Meter PC Software User Manual

Handheld Gaussmeter Gaussmeter

Continuous, remote monitoring and logging of electromagnetic fields

Kistler LabAmp for DynoWare

Low Cost Three-Axis Fluxgate Sensor GFS-E. Measurement Range up to ±1000μT Output Voltage Calibration Error: 0.5% Noise 20pTrms/ Hz at 1Hz

NHT 3DL. The new landmark meter for electromagnetic safety. Percipere Aestimare et Inquirere

Selective and broadband low frequency field analysis

TT7000R4. DS Instruments. D text. RF Power Meter, Signal Generator, Frequency Counter. -Key Features-

2kVA EARTH TESTING CURRENT INJECTION SYSTEM 4046 / 4047 DATASHEET REDPHASE INSTRUMENTS

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control

SRM-3000 Selective Radiation Meter

WaveStation Function/Arbitrary Waveform Generators

REFERENCE AIRBASS Wireless Subwoofer Volume Control System

Selective and broadband low frequency field analysis

PMM 7010 EMI RECEIVERS. The EMI Receiver with built-in LISN

VIBCONNECT RF. Wireless Condition Monitoring. Catalog. PRÜFTECHNIK Condition Monitoring Edition: Oder No.: LIT

DC Electronic Loads 8500 Series

Spectrum Analyzer. Spectrum Analyzer. Antenna Panel Inputs. Auxiliary Antenna Inputs. Two models available: 24 GHz and 8 GHz OSCOR

Narda EMF drive test solution

UltraTEV Locator Portable Partial Discharge (PD) investigation system.

Low Frequency. Precision test equipment for safety in electric and magnetic fields

Green ADVANTAGES. Spectrum Analyzer Two models available: 24 GHz and 8 GHz SPECTRUM ANALYZER. Antenna Panel Inputs. Auxiliary Antenna Inputs OSCOR

RIGOL Data Sheet. DG3000 Series Function/Arbitrary Waveform Generator DG3121A, DG3101A, DG3061A. Product Overview. Easy to Use Design.

Winding Ohmmeter & Tap Changer Test Set RMO40TD with Demagnetizer

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.2

VLR-502 Wireless System. Owner s Guide

WaveStation Function/Arbitrary Waveform Generators

True RMS Bench Multimeters 2831E and 5491B

Advanced Test Equipment Rentals ATEC (2832)

EA3012 TRANSCONDUCTANCE AMPLIFIER OPERATION MANUAL

1510A PRECISION SIGNAL SIMULATOR

Review: The MFJ-225 Graphical Antenna Analyzer Phil Salas AD5X

TDT Biological Amplifier User s Guide? TDT

Read and be familiar with this manual before operating or servicing this device. To ensure operator, technician, and patient safety, use only as

Magnetic Field Compensation System MR-3

MultiMaster. Base Station Test Tools. Multi Purpose Base Station Tester. Introduction. Feature

ST121 SIGNAL IMITATOR TECHNICAL DESCRIPTION AND OPERATING MANUAL

TBSI W32 System Manual Version 3.0

INSTALLATION MANUAL. Model: Smart Analyzer Manufacturer: Smart Impulse. Power meter with consumption breakdown by use 03/12/13

2801 Multilock. Communications System Analyzer. Data Sheet. Boosting wireless efficiency

Introduction. Specifications. Features. Controls. Model 103

S3602C Vector Network Analyzer Datasheet

ISOBE5600. Data sheet. Isolated Probe Systems. - ISOBE5600 Isolation system - ISOBE5600 Transient recorder. Features and Benefits

Fluke Norma 4000/5000

TABLE OF CONTENTS. Electromatic Equipment Co., Inc. -1-

SGD-EEM «MEDUSA» GEOELECTRICAL MULTIFUNCTION RECEIVER

True RMS Bench Multimeters 2831E and 5491B

Medidores de vibración salida RS232 Datalogger VT-8204 LUTRON manual ingles

Agilent PNA Series RF Network Analyzers

Infocal 9 Energy calculator

UNIVERSAL-DDS-VFO UDV ( 1 Hz to 10 MHz)

MIT415 Insulation tester

acknowledgments...xv introduction...xvii 1 LEGO MINDSTORMS NXT 2.0: people, pieces, and potential getting started with the NXT 2.0 set...

U1571A Ni-MH Battery Pack for U1600A Handheld Oscilloscopes

Model 4402B. Ultra-Pure Sinewave Oscillator 1Hz to 110kHz Typical Distortion of % Serial No. Operating Manual

Application Note TS-EMF. System for RF Exposure Measurements. System Check with Tri-Axis Sensor (Isotropic Antenna)

OFFSHORE ENERGY. BUYER S GUIDE HYDROlog Hydrotest Logger Range. Simply advanced

Why Modern Servicing Requires Complete Waveform & Circuit Analyzing!

AT-7000 Advanced Wire Tracer

Agilent N9340B Handheld Spectrum Analyzer (HSA)

Transcription:

Edition 3.1 2009-09-03 MAGNETIC FIELD METER 2000 Operator s Manual The MFM 2000 is a professional magnetic field instrument To make the best use of the instrument we recommend that you read this manual carefully. COMBINOVA MARKETING AB Postal address Visiting address: Domkraftsvägen 1 Domkraftsvägen 1 S-197 40 Bro S-197 40 Bro Sweden Sweden Internet: www.combinova.se e-mail: sales@combinova.se Tel: +46-8-627 93 10 Fax: +46-8-29 59 85

2

CONTENTS Section 1 - INTRODUCTION 1.1 Magnetic Fields from IT equipment 1.2 The Instrument 1.3 Combinova AB - The Company Behind the Product Section 2 - UNPACKING AND INSPECTION 2.1 Unpacking 2.2 Inspection Section 3 - OPERATING INSTRUCTIONS 3.1 General Operation 3.2 Battery Charging 3.3 Display 3.4 Parameters 3.5 Measurements Section 4 - SPECIFICATIONS WARRANTY FORM 3

4

Section 1 - INTRODUCTION 1.1 Magnetic Fields from IT equipment 1.2 The Instrument 1.3 Combinova AB - The Company Behind the Product 5

The Magnetic Field Meter 2000 (MFM 2000) is a professional instrument designed to measure magnetic fields simultaneously in two frequency bands. Band 1 is from 5 Hz to 2 khz and band 2 is from 2 khz to 400 khz. The MFM 2000 has been developed for self-contained operation with such features as built in rechargeable batteries, LCD touch panel display, PC communication using a USB 2 interface and a large data logging memory. The instrument has a full bandwidth real time dual band spectrum analysis to provide detailed information about the magnetic field. MFM 2000 is specifically designed to measure magnetic fields according to MPR 2 and TCO testing specifications and is the first instrument to combine dual frequency band testing in one instrument. 1.1 Magnetic Fields from IT equipment Since the 1980 s the use of IT equipment in offices and at home has increased rapidly. Research findings and user concern about the exposure to low frequency magnetic fields, has led to the development of a number of certification standards including limits for emission of low frequency electric and magnetic fields. The most widely used certification is the TCO certification that started with TCO 92 for video displays and newer certifications like TCO 99, TCO 03 and TCO 06 have been introduced since then. Similar certifications are also present for flat displays, printers, desktop an laptop computers. All these certifications puts limits on the emission of low frequency magnetic fields. Typical limits for these certifications are 200 nt in band 1 and 25 nt in band 2. More details about the test methods and certifications are available from TCO Development (www.tcodevelopment.com). 6

1.2 The Instrument The MFM 2000 instrument is designed using the latest technology in amplifiers, AD-converters and signal processors to achieve the best measurement performance. Using the same antenna the instrument covers two frequency ranges, band 1 from 5 Hz-2 khz and band 2 from 2 khz-400 khz. With an innovative concept for signal handling it has a wide dynamic range and still a very good resolution at low magnetic field levels. With dual band spectrum analysis built into the instrument the measurement gives complete information of the different frequency components in the magnetic field. The user interface is mainly handled by the graphic LCD-display that has a touch panel to select the type of measurement, display settings and to define the parameters controlling measurements and related functions. Two push buttons are used for power ON/OFF and to START measurements. The instrument has a large memory bank to store test results and to provide possibilities for manual or automatic logging of test results. External communication to a PC is handled by the built in USB 2 interface and the PC software handles a variety of applications including remote control for laboratory use and handling of logged data. The built in smart battery allows for around 10 hours of operation where mains power is not available. The standard battery charger supplied with the instrument can be used both to charge the battery and also to supply the instrument in laboratory applications. 7

8

1.3 Combinova AB The company behind the product Magnetic Field Meter 2000 has been developed by Combinova AB. We are also responsible for the manufacturing, marketing and after-sales service of the instrument. Combinova has been making instruments for magnetic and electric field measurements for the last 20 years. Other products in this product family are: MFM 3000 - Magnetic Field Meter, wide band 5 Hz 400 khz with spectrum analysis and applications for EN 50366 and ICNIRP testing. EFM 200 Electric Field Meter for electrostatic and alternating electric fields in two bands 5 Hz 2 khz and 2 khz 400 khz. EFM 100 - Electric Field Meter for alternating electric fields in two bands 5 Hz 2 khz and 2 khz 400 khz. FD 1 Field Detector for alternating magnetic and electric fields from 20 Hz 2 khz. FD 2 - Field Detector for alternating magnetic and electric fields from 2 khz 400 khz.. FD 3 Field Dosimeter for logging of alternating magnetic fields from 20 Hz 2 khz. More details about these products are available at www.combinova.se 9

SECTION 2 UNPACKING AND INSPECTION The MFM 2000 is delivered in a specially designed transportation case, which also contains the standard accessories that are used with the instrument. Open the case and check that the following items have been supplied. MFM 2000 instrument Universal Battery Charger USB Communication Cable Operator s Manual Calibration certificate Inspect the transportation case, the instrument and the accessories for any damage caused during transit. If damage has occurred, please contact the shipping company who delivered your instrument. IMPORTANT! Complete the warranty form and return a copy to: Combinova AB Domkraftsvägen 1 S 197 40 Bro Sweden The warranty is only valid when the warranty form has been completed and received by Combinova AB. NOTE! Before switching on the instrument, read this manual carefully. 10

11

Section 3 - OPERATING INSTRUCTIONS 3.1 General Operation 3.2 Battery Charging 3.3 Display 3.4 Parameters 3.5 Measurements 12

3.1 General Operation The instrument is operated by the ON-OFF button and the MEASURE button on the front panel. All other settings are handled by menus on the touch panel. ON-OFF To turn on the instrument is turned on by pressing the ON-OFF button on the front panel until the display is lit up. After power on a start up display is shown with program versions and some initial tests. The initial tests shown on the display are: DSP Boot DSP RAM-Test DSP Vector Init When tests are completed it shows the text Init Ready and automatically moves to the measurement display selected last time the instrument was used. To turn off the instrument depress the ON-OFF button for a few seconds and wait for the display to turn off. The instrument is automatically turned on if the battery charger is connected and cannot be turned off during charging. MEASURE The measure button is used to start a single measurement. If the button is depressed until the single measurement is completed a continuous measurement is started and keeps on running until the measure button is depressed again. After stopping a continuous measurement the last result is shown on the display. 13

Touch panel The display is also a touch panel where selections and settings in the instrument can be made. The three menus are: DISPLAY menu includes settings for the display of measurement results. Details are described in chapter 3.3. PARAMETERS menu contains all other instrument settings. Details are described in chapter 3.4. SAVE X is a funtcion key that saves the last measurement. X is the number of the results that will be saved when activated. If no measurment has been done or the data is already saved the response when attempting to save is NO DATA. Note you cannot save dat from continuous measurements. The memory can handle up to around 7,000 sets of data including results and spectra. To enter a menu use the touch panel pointer to enter the menu. The available selections are shown when a menu is selected and the text for the current selection is shown inverted (white text on a black background). As soon as a menu is selected a new line of keys will appear at the bottom part of the display. These keys and their functions are: UP + key is used to move up among available selections in the menu or to increase the setting of a variable. DOWN key is used to move down among available selections in the menu or to decrease the setting of a variable. 14

Pointing directly at a selection in a menu is also possible. ENTER key is used to confirm a selection and if there are available sub-menus they will appear after confirming the first selection until all related selections are made. CANCEL key is used to leave a menu without changing of any selections or settings. 15

3.2 Battery Charging The MFM 2000 can be operated either from the mains using the battery charger or from the internal rechargeable battery. When having the battery charger connected during measurements make sure the charger is located as far away from the instrument as possible to make sure that the magnetic field from the charger has a minimum influence on the measurement results. The charging status in percent of full charge of the battery is indicated in battery symbol on the display. Charging of the battery should be done when the charging level drops below 20 %. Whenever the battery needs charging just connect the battery charger to the instrument. If the instrument is off it will turn on and battery charging will start automatically. The instrument cannot be turned off when the battery charger is connected. Battery charging cycle is controlled by the firmware in the instrument so there is no risk involved if the battery charger is left connected to the instrument even after the battery has been fully charged. Charging time for an empty battery is around 4 hours. If the battery is replaced, the charger must be connected to start the instrument and initialize the new battery. NOTE! The battery is a smart battery with its own electronics and no other type of battery can be used with the instrument. 16

3.3 Display The MFM 2000 uses a touch panel for all operator settings and selections. To calibrate the coordinates on the touch screen keep the MEASURE button depressed at power on until you to get into the calibration function. A screen with a square in the upper left and another square in the lower right corner will appear. Mark the upper left corner with the pointer and keep it there until the instructions on screen asks you to mark the lower right corner. Keep the pointer on the square until the screen reports calibration ready. Wait for the saving of calibration data. The instrument will automatically return to the measurements after the calibration is completed. This calibration procedure can be repeated at any time if the positions of different screen selections are changing. 17

In the Display menu you can select to show the results either with the Normal numerical result display or Spectrum graphical display where there is a choice to either show the spectrum for band 1 Spectrum B1 or the spectrum for band 2 Spectrum B2 together with the numerical results. After a measurement you can select the other spectrum to get details for both bands related to the same measurement. In the normal numerical display of results the total result in each band together with the largest signal in each band is shown. In the graphical displays with spectrum the total result, the largest and second largest signal shown is related to the spectrum shown on the display. 18

3.4 Parameters In the Parameter menu you can set the light and contrast of the display to optimize the readability of the display. How to use the menu keys is described in chapter 3.1 General operation. 19

3.5 Measurements Before making a measurement on a test object it is important to measure the background emission to make sure it is low enough not to influence the test results. Background fields are normally added to the field from a test object according to the formula: B measured 2 = B test object 2 + B background 2 B measured is the measurement result. B test object is the emitted field from the test object. B background is the background field. Note! This formula cannot be used to compensate for a too high background field, because other interactions between the test object fields and the background fields can occur. Test results are shown in nt with one decimal until the field is larger than 999 nt. Higher fields are shown in µt with two decimals. 20

After making a measurement the normal mode display shows the total results in band 1 and band 2 together with the largest signal in each band. MFM 2000 50 % Normal mode single measurement Band 1 5 Hz 2 khz RMS-value Largest signal 196.8 nt 157.2 nt at 85.00 Hz Band 2 2 khz 400 khz RMS-value Largest signal 16.8 nt 15.2 nt at 55.00 khz Parameter Display Results including a spectrum for each band can also be selected. The corresponding display showing results in band 1: 21

For results in band 2 the spectrum display will be: Note that the display showing a spectrum also includes the largest and second largest signal in each band. After a measurement you can select the different display options to look in more detail at the spectrum and result in each frequency band for the last measurement. 22

Section 4 SPECIFICATIONS Specifications are given at the temperature Tamb = 23 ± 5 C. Specifications subject to change without notice. Antenna system Frequency range Frequency response: Band I: Band II: ALTERNATING MAGNETIC FIELDS 3-axis, concentric, orthogonal. Coil area 100 cm² 5Hz - 2000 Hz (Band I) and 2 khz - 400 khz (Band II) at 5 Hz -3 db at 2 khz -3dB at 2 khz -3dB at 400 khz -3dB and below and above and below and above 5 Hz >80 db/octave 2 khz >40 db/octave 2 khz >80 db/octave 400 khz >40 db/octave Measurement range Accuracy Band I: ±(1% of reading +2 nt ) Accuracy Band II: ±(1% of reading +0.2 nt ) Measurement rates 1 s single measurements and continuous measurements 23

Display Parameter storage Result memory Power Communication Operating temperature MISCELLANEOUS Graphical 5,7" LCD display, with touch panel Instrument parameters and corrections are stored in a non-volatile memory 64 Mbit Smart Lithium ion battery, 10.8 V and 4.8 Ah. Universal battery charger 90-250 V, 45 65 Hz USB 2 interface for PC communication 10 C to +50 C. Operating humidity 10-85%. Dimensions Weight Environment protection IP 53 400 x 110 x 190 mm (LxWxH) Instrument weight 2.5 kg. 24

25

WARRANTY FORM for MFM 2000 Customer : Customer address : Delivery date : Warranty period : Serial number : Program version : The warranty includes material and labour cost for service and repair, but not transportation costs in any direction. If new program versions become available during the warranty period a free update is also included. A condition for the warranty is that a correctly filled in copy of the warranty form is sent to Combinova AB. Note: Always return the instrument in its own transportation case. 26

27

WARRANTY FORM for MFM 2000 (customer copy) Customer : Customer address : Delivery date : Warranty period : Serial number : Program version : The warranty includes material and labour cost for service and repair, but not transportation costs in any direction. If new program versions become available during the warranty period a free update is also included. A condition for the warranty is that a correctly filled in copy of the warranty form is sent to Combinova AB. Note: Always return the instrument in its own transportation case. If service is required the instrument should be sent to : Combinova AB Domkraftsvägen 1 S-197 40 Bro SWEDEN 28