ADJUSTABLE SPEED DRIVES. HX7 Series. 18 Pulse. Phone: Fax: Web: -

Similar documents
ADJUSTABLE SPEED DRIVES. W7 Series. 18 Pulse

ADJUSTABLE SPEED DRIVES. HX7 Series. 18-Pulse

S11 Adjustable Speed Drive Engineering Specification

ADJUSTABLE SPEED DRIVES FS1

E3 Adjustable Speed Drive Engineering Specification

VF-nC1 Adjustable Speed Drive Engineering Specification

ADJUSTABLE SPEED DRIVES VF-S11 Sords Electric

SECTION 16483D ADJUSTABLE FREQUENCY DRIVE - MICRODRIVE (MVX <10-HP)

Variable Frequency Drive / Inverter (0.4 ~ 280kW)

ADJUSTABLE SPEED DRIVES. AS1 Drive

AV-300i Specifications. Saftronics Inc. PC10 Product Specifications PC10. Mini Vector AC Drive

Inverter Drive /Vector Drive Motors & Controls

VFD - D700 Series Specifications. The latest low-cost variable speed control solution for centrifugal pumps.

NGS N01 LIMESTONE CRUSHER ELECTRICAL SPECIFICATIONS

P-SERIES VFD 1-40HP (200~230VAC), 1-400HP (380~480VAC),3Ø Dual Rated for Constant & Variable Torque Integrated PID Control

AF91 Adjustable Frequency Drives Series B

Phoenix DX Clean Power (18 Pulse) AC Drive

PRODUCT OFFERING ADJUSTABLE SPEED DRIVES

ACH550 HVAC Drive Submittal

1. Institute of Electrical and Electronic Engineers (IEEE) a. Standard , IEEE Guide for Harmonic Content and Control.

Manual Overview...1 2

PowerFlex 400 AC Drive Guide Specification

SECTIONS , (15040, 15767, 15950, 16269) Guide Specification for VARIABLE SPEED DRIVES with Optional Bypass

System configuration. Ratings 400 V Class three-phase 90 to 800 kw 690 V Class three-phase 90 to 1000 kw SX-D. Frequency inverters.

NEWPCC VARIABLE FREQUENCY DRIVES Section LAB RENOVATION BID OPPORTUNITY NO PAGE 1 OF SCOPE

PowerFlex 400 Submittal

Fan and Pump AC Inverter

For additional PowerFlex 4 and 40 data and general drive information, refer to the following publications:

AV-300i Specifications. Saftronics Inc. VG10 Product Specifications VG10. Dynamic Vector Drive

D SERIES EM16 IP 20 / NEMA 1 & IP 66 / NEMA 4X COMPACT VECTOR CONTROL DRIVE EM 16 COMPACT VECTOR CONTROL DRIVE

PowerGard Series C 18-Pulse Enclosed Drive Controllers

APQline Active Harmonic Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

General Specifications FECA-TE /2010. Phone: Fax: Web:

TOSVERT TM VF-nC3 Parameter List

SX (400V) System configuration

G8000MM Series IGBT. 100 to 750 KVA UPS UNINTERRUPTIBLE POWER SYSTEMS. 94% Efficiency. Input PF >0.98 DESIGN

SX (400 V) System configuration

INDEX. i 1. B Braking Resistor Dimensions: A 24 Braking Resistors: A 20 Braking Units: A 20. DURAPULSE AC Drive User Manual

Medium Voltage VFD. Perfect Energy Saving Drive 3kV 200kVA ~ 3,700kVA / 4kV 250kVA ~ 4,700kVA 6kV 400kVA ~ 7,500kVA / 10kV 600kVA ~ 11,000kVA

Product description. At a glance. Customer benefits

PRODUCT OFFERING ADJUSTABLE SPEED DRIVES

Electrical Submersible Pumping Systems

The new Yaskawa Varispeed G7 Inverter

SJ700 series High performance with Many useful Functions and, yet User Friendly. WJ200 series Pursuing the Ideal Compact Inverter NEW

SX (690 V) System configuration

2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing.

General Purpose Drives

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

Frequently Asked Questions (FAQs) MV1000 Drive

Index 2. G Gain settings 4 31 Glossary of terms A 2 Grommets 2 13

TOSHIBA International Corp

Bypass Panels FRENIC-EcoPAK. Fuji Electric Corp. of America FECA-IN-105 / Information subject to change without notice.

SECTION LOW VOLTAGE ACTIVE HARMONIC FILTER SYSTEM NEMA 1 ENCLOSED

BOSTON GEAR CONTROLLERS. ACE 20 Series 1/8 through 10 HP Adjustable Frequency AC Motor Controllers. MTY (81)

MV1000 MEDIUM VOLTAGE AC DRIVE 175 HP TO 16,000 HP

CHAPTER AC DRIVE PARAMETERS. In This Chapter...

Power IT LV Active Filters PQFI PQFM PQFK. The ABB comprehensive solution for active filtering of harmonics

Variable Frequency Drive Packages with Harmonic Mitigation. Low Harmonic Drive Packages Engineered by Rockwell Automation

Integra 1560 and 1580 Digital Transducer Systems

FUJI Inverter. Standard Specifications

Design Specifications Operator Keypad Environmental and Operating Conditions

SJ series P1 High performance inverter with innovative ease-of-use and excellent driving performance

NX Series Inverters. HVAC Pocket Programming Guide

TMdrive -XL Series Family Product Application Guide. solar inverters. power generation

D SERIES LM16. COMPACT DRIVE V/f and SLV CONTROL. LM16 COMPACT DRIVE V/f and SLV CONTROL

HPVFP High Performance Full Function Vector Frequency Inverter

Multimeter 500CVD21 RTU500 series

WJ200 series Pursuing the Ideal Compact Inverter

Rexroth Frequency Converter Fe 0.75 kw to 7.5 kw / 400 VAC

TAC ATV38, IP55. Variable Speed Drives for Asynchronous Motors. 3-phase. 380/460 V, Hz

PROGRAMMABLE AC POWER SOURCE MODEL 6500 SERIES MODEL 6500 SERIES. Programmable AC Power Source. Key Features:

Frequency Inverters. SJ700B Series. Powerful Inverter for General Purpose Use. SJ700B Series

Multi-function, Compact Inverters. 3G3MV Series

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

A Subsidiary of Regal-Beloit Corporation. AC Inverter Terminology

Gutor PxW AC UPS Designed for North American Market

DSAE - AAA - B - C - DD - E AAA

Micro and Mini Inverters

Power IT LV Active Filters PQFA - PQFL - PQFT

Active Harmonic Filter

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

Softstarters. Specification guide. Type PST. Low Voltage Products & Systems

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

Design Characteristics. FlexDrive II. Series

ROLL TO ROLL FUNCTION MANUAL FR-A (0.4K)-04750(90K)-R2R FR-A (0.4K)-06830(280K)-R2R FR-A (315K)-12120(500K)-R2R

GS1 Parameter Summary Detailed Parameter Listings...4 9

2.10. Adjustable Frequency Drives. Clean Power Drives. Clean Power Drives

Univerter-MV. Medium Voltage Variable Speed Drive

Power Processor - Series 700F 10KVA to 150KVA

Frequency Inverters. VF-nC3 VF-S11 VF-FS1 VF-PS1 VF-AS1

Variable Frequency Drives Basic Operating Principles and Core Maintenance Considerations

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

User manuel. Hybrid stepper servo drive

Types VIS and CRE. A e. Compliance with Standards. Uses. Features

Variable Speed Brushed DC Motor Drive

MYS WWSP PLUS III POWER UNIT

A700 Series. Variable Frequency Drives UNSURPASSED POWER AND CONTROL 1 /2-700 HP

NX series Constant and variable torque Variable Speed Drives for induction motors

Drives 101 Lesson 3. Parts of a Variable Frequency Drive (VFD)

Transcription:

ADJUSTABLE SPEED DRIVES HX7 Series 18 Pulse

Toshiba HX7 In some industrial applications, users need reliable and efficient adjustable speed drives that do not contribute significant harmonic distortion to the power grid. The HX7 meets this need. The HX7 is the newest addition to the Toshiba 7-Series family offering the latest technology and proven reliability. Patented 18 Pulse Design* Small Footprint Powerful, User-Friendly Operator Interface Variety of Communication Options 1. Small Footprint with Uniform 24 Depth 1 5 2. User-Friendly Electronic Operator Interface (EOI) 3. Variety of User Configurable Options 4. Gasketed and Filtered Enclosure Force Ventilated 5. Top or Bottom Cable Entry/Exit 6. 65 KAIC Breaker 7. Proven Toshiba ASD Technology 8. Integrated Phase- Shifting Transformer 2 3 4 6 7 8 * US Patent 6396723 JP Patent 2000-179543 (Pending)

The Drive Solution Total Harmonic Distortion (THD) can come from many sources, including computers, fluorescent lights, copiers and six-pulse drives. The HX7, with Toshibaʼs patented 18 Pulse Autotransformer design, removes the distortion that would be generated by a six pulse drive. Meets IEEE 519 Guidelines without Adding Filters Produces a Ripple Free Voltage on DC Bus Clean Sinusoidal Input Current Waveform Up to 60% Reduction in Transformer Losses 100 90 80 70 INPUT CURRENT HARMONICS Current Voltage 60 50 40 30 20 10 0 6 Pulse (Typical) 18 Pulse HX7 5 7 11 13 17 19 23 25 29 31 35 37 41 43 47 49 HARMONIC NUMBER e: 60 Hz @ : 113 Hz Ch1 500mV Ch2 5.00mVΩ M2.00ms Ch1 10mV Small Footprint The high cost of real estate and constraints of existing facilities make size an important consideration in drive selection. - 400 HP Drive Only 42 Wide - 24 Depth on All Sizes - Integrated Phase Shifting Autotransformer - Saves Real Estate on New Designs - Easier Replacement of Old Drives in Existing Facilities 60 200 HP: 100 H x 30 W x 24 D 250 400 HP: 100 H x 42 W x 24 D 500 800 HP: 100 H x 76 W x 24 D (Addition of a bypass option will increase enclosure size)

T1 Micro for Harmonic Distortion Powerful, User-Friendly Operator Interface The HX7 advanced Electronic Operator Interface (EOI) is so intuitive the manual is usually not needed to make drive setting adjustments. The HX7 features menu driven programming as well as direct access to all of the motor control parameters. A built-in rotary encoder makes programming quick and easy. Easy Start-up Wizard Remote Mountable up to 1,000 Feet Real Time Clock Option Flash Upgradable EOI Software Display Multiple Parameter Simultaneously Standard Keypad Design for Low Voltage and Medium Voltage Drives Variety of Communication Options In todayʼs fast-paced manufacturing world, coordinated systems require communications from drive-to-drive and drive-to-system. Built-in ports and a variety of option cards provide versatility in communication selection. Built-in RS232 / 485 and TTL Ports Communication Protocol Options - Profibus - DeviceNet - Modbus RTU - Modbus+ - Metasys - Ethernet

Meets or Exceeds Your Specifications Standard Specifications Item Voltage Class 460 V Maximum HP 60 75 100 125 150 200 250 300 400 500 600 700 800 Drive Rating (A) 77 96 124 156 190 240 302 370 480 628 753 879 960A Dimensions 100 H x 30 W x 24 D 100 H x 42 W x 24 D 100 H x 76 W x 24 D Power Requirements Output Frequency 0 299 Hz Main Circuit Control Power Three Phase 460 V Input Auto-Transformer 18-pulse design with Circuit Breaker, IGBT Output DC Bus Control Power Tolerance Voltage: ±10%; Frequency: ±2% Control Specifications Control Method Sine Wave PWM System; Flux Field Current Vector Control V/Hz Control Overload Rating Frequency Setting Frequency Precision Frequency Resolution Acceleration / Deceleration Speed Regulation Torque Regulation Set Point Control (PID) Analog Inputs Analog Outputs Discrete Inputs Output Contacts Signal Isolation Control Board Communication Ports Data Transmission Main Protective Functions Soft Stall Retry Restart LCD / EOI (Liquid Crystal Display / Electronic Operator Interface) LED Indicators Keys Monitoring Selectable Display Units EOI Communication Ports Remote Mount Display Constant Torque, Variable Torque, Open Loop Vector, Auto or Manual Torque Boost, 5 point V/Hz Custom Curves 120% for 60 seconds; 100% continuous Rotary Encoder integrated into EOI, 0 to 10 V, ±10 V, 4 to 20mA, Binary Input, Motorized Potentiometer Input Analog Input: ±0.2% of Maximum Output Frequency; Digital Input: ±0.01% of Maximum Output Frequency Panel Operation: 0.01 Hz; Analog Input 10 to 12 bit A to D Converter: 0.1 Hz 0.1 to 6000 seconds Up to 0.1%; 60:1 Speed Range 10% Regulation; less than 3% Ripple from 50 to 100% Fange Proportional Gain, Integral Gain, Feedback Settings Upper/Lower Deviation Limits; Feedback Source Delay Filter, Feedback Settings Differential Gain Four Programmable: (1) 4 to 20mA, (1) 0 to 10 V, (1) -10 to +10 V, (1) 1 to 10kΩ potentiometer connection Two Programmable to 31 Functions Eight Programmable to 67 Functions; Expandable to (N-Value) Three Output Terminals, Programmable to 52 Functions; Form C Contacts Rated 250 V AC, 2 Amps Inductive Available 3-Channel Signal Isolation for AM/FM outputs and II terminal input, rated at 750 V RS232 / 485 and TTL ports standard Profibus, DeviceNet, Modbus RTU, Modbus+, Metasys, Ethernet (some devices are external) Current Limit, Overcurrent, Overvoltage, Undervoltage, Load Side Short Circuit, Load Side Ground Fault, Armature Short; Overtorque, ASD Overload, Motor Overload, Heatsink Overheat; Open Output Phase, Loss of Feedback; CPU Error, Communications Error Automatic Load Reduction Control During Overload Can Automatically Clear Fault upon Trip; Programmable to 10 tries with up to 10 seconds between tries Restart into a Rotating Motor Interface 128 x 64 Pixels. Backlit LCD Display; Ability to display multiple parameters on one screen Keypad may be operated from an external power source Software is flash upgradable Includes multi-function rotary encoder Run (Red) / Stop (Green), Remote / Local (Green), DC bus charge indication (Red) Local /Remote, Monitor / Program, Run, Enter, ESC, Stop / Reset, Up, Down Main display shows two monitored items continuously, or scrolls up to 40 items. User-selectable and configurable, along with scaling factor multiplier Voltage display selectable: Volts or %, Current display selectable: Amps or %. RS232 / 485 and TTL ports standard Remote mountable up to 1000 ft Construction NEMA 1, IP20, Gasketed and Filtered Free standing, front maintenance type, top or bottom access for motor and power cables Enclosure Panel Construction Cooling Forced air cooled Top-mounted fans may be removed during shipment or installation Color ANSI-61 Gray Ambient Conditions Ambient Temperature 0 40 C, 32 104 F Humidity Altitude Installation Electrical Compliance Max. 95% (non-condensing) 1000 m (3300 ft) above sea level or less Indoor, no direct sunlight, protect from corrosive gases, and/or explosive gases Standards NEC, ANSI