IRIS POWER TGA-B. Periodic Online Partial Discharge Monitoring Instrument for Turbine Generators and Motors

Similar documents
IRIS POWER PDTracII. Continuous On-line Partial Discharge Monitoring for Motors, Generators, Dry Type Transformers, and Air-Insulated Switchgear.

IRIS POWER PDTracII. Continuous On-line Partial Discharge Monitoring for Motors, Generators, Dry Type Transformers, and Air-Insulated Switchgear.

PORTABLE PARTIAL DISCHARGE MONITORING INSTRUMENT

PARTIAL DISCHARGE MEASUREMENT ON ROTATING MACHINES

CONTINUOUS ON-LINE SYSTEM FOR PARTIAL DISCHARGE MONITORING FOR HA1 AT CHE ROBEŞTI

Knowledge Is Power SM Apparatus Maintenance and Power Management for Energy Delivery. Application of EMI Diagnostics to Hydro Generators

PARTIAL DISCHARGE MEASUREMENT

Relative Ability of UHF Antenna and VHF Capacitor Methods to Detect Partial Discharge in Turbine Generator Stator Windings

Stator Winding Partial Discharge Activity for Air- Cooled Generators

Low Frequency Velocity Sensor

Current clamps for AC current

Why partial discharge testing makes good sense

Doble Solutions for Partial Discharge. Greg Topjian Solutions Manager

TECHIMP Technologies & Services for Diagnostics and Monitoring of High Voltage Assets

II. TRADITIONAL APPROACH OF PD MEASUREMENTS

Africa Utility Week Focus Day Substation Condition Monitoring Benefits of Ultrasound

Type 297, High-Voltage Mica Capacitors Corona-free Mica Coupling Capacitors for Medium-Voltage PDA s

Objective Methods to Interpret Partial-Discharge Data on Rotating-Machine Stator Windings

RECENT DEVELOPMENTS IN IEEE AND IEC STANDARDS FOR OFF-LINE AND ON-LINE PARTIAL DISCHARGE TESTING OF MOTOR AND GENERATOR STATOR WINDINGS

PD Solutions. On-Line PD Measurement Devices

TOS5300 SERIES Hipot Tester/Hipot Tester with Insulation Resistance Test

NPN PNP NPN PNP NPN PNP

Ieee Guide For Partial Discharge Testing Of Shielded Power

GENERATOR TESTING APPLICATION GUIDE. reliable. precision.

Advanced, accurate and intelligent monitoring for your transformer

Fluke 3540 FC Three-Phase Power Monitor

Top-Innovator MotorAnalyzer 2. Multi-purpose testers for electric motors and windings. Made in Germany Expect more.

Diagnostic testing of cast resin transformers

For Medium Voltage Motors, Generators, Switchgear, Bus Duct and Cable Terminations

DOBLE F6150e TECHNICAL SPECIFICATIONS

1587/1577 Insulation Multimeters

MIT510/2, MIT520/2 and MIT1020/2

Flexible AC current probes

Fluke 1587 FC/1577 Insulation Multimeters

EXPERIENCE WITH ON-LINE PARTIAL DISCHARGE MEASUREMENT IN HIGH VOLTAGE INVERTER FED MOTORS

DOBLE F6150SV TECHNICAL SPECIFICATIONS

A1-209 EXPERIENCES IN IDENTIFICATION OF PARTIAL DISCHARGE PATTERNS IN LARGE HYDROGENERATORS

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Top-Innovator MotorAnalyzer 1. Multi-purpose testers for electric motors and windings. Made in Germany Expect more.

Condition-based maintenance of power transformers Complete three-phase system Turns Ratio: Recovery Voltage: Winding Resistance:

Features 100A400AM20. 4kHz 400MHz Class A Portable Full VSWR tolerant CE & RoHS compliant High Efficiency

Advanced Test Equipment Rentals ATEC (2832) CIBANO in-1 test system for medium- and high-voltage circuit breakers

Modular Partial Discharge (PD) & Radio Interference Voltage (RIV) Detector

TORKEL 900-series Battery Load Unit

TECHIMP Power Transformer Monitoring

TORKEL 900-series Battery Load Unit

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

The University of New South Wales. School of Electrical Engineering and Telecommunications. High Voltage Systems ELEC9712. Appendix Partial Discharge

Advancements in online partial discharge monitoring and assessment of MV through EHV Substation assets

200Amp AC Clamp Meter + NCV Model MA250

Dielectric response and partial discharge measurements on stator insulation at varied low frequency. Nathaniel Taylor

3. Contact Form A: SPST-NO

NI PXI-2532 Specifications

RIGOL. User s Guide. RP1000D Series High Voltage Differential Probe. Feb RIGOL Technologies, Inc

Dawson DDM230C. True RMS Multimeter with Bar Graph Display User s Manual

Fluke 5820A Oscilloscope Calibrator Specifications

DM-45 Digital Multimeter

Improve asset protection and utilization

User s Guide. 400A AC/DC Clamp Meter. Model MA220

Fluke MDA-510 and MDA-550 Motor Drive Analyzer

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

NEW DEVELOPMENTS IN FLUX MONITORING FOR TURBINE GENERATORS. M. Sasic, B. A. Lloyd and S.R. Campbell Iris Power LP, Mississauga, Ontario, Canada

Further Experience in the Use of Existing RTDs in Windings of Motors and Generators for the Measurement of Partial Discharges

Wide-band Models from DC to 100 MHz

Protection components

Fluke 3540 FC Three-Phase Power Monitor

Complimentary Reference Material

T5-600/T Electrical Tester

Insulation resistance testing. A complete solution for every application.

Motor Winding Ohmmeter RMO50M

Vector Network Analyzers ZVB

79/26 Series III Multimeter

TT-SI 9001 / TT-SI MHz Active Differential Probes

MPD 500. Partial Discharge Measuring System for Routine Test Applications

1 INTRODUCTION ORDER CODE / INFORMATION

On-line Flux Monitoring of Hydro-generator Rotor Windings

P2 Power Solutions Pvt. Ltd. P2 Power Magnetics. Quality Power within your Reach. An ISO 9001:2008 Company

Partial discharge diagnostics on very long and branched cable circuits

10. DISTURBANCE VOLTAGE WITHSTAND CAPABILITY

A NOVEL APPROACH TO PARTIAL DISCHARGE MONITORING

PD Diagnostic Applications and TechImp solutions

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

MIT510, MIT520 and MIT1020

R&S RSC Step Attenuator Specifications

20 General technical data XI/ON

NI PXI/PXIe-2532 Specifications

Voltage Sensors URV5-Z

NI PXI-2521 Specifications 40-Channel DPST Relay Module

Advanced Test Equipment Rentals ATEC (2832) CP RC. Resonance circuit for GIS testing

NI PXI-2530 Specifications

DC/DC Converter B_XT-2WR2 Series

PD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description

Partial Discharge Theory, Modeling and Applications To Electrical Machines

MW3105 DIGITAL CLAMP MULTIMETER

SIGNATURE ANALYSIS FOR ON-LINE MOTOR DIAGNOSTICS

AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER

Advanced Test Equipment Rentals ATEC (2832)

Partial Discharge Measurements on 110kV Current Transformers. Case Study. Results

USER'S MANUAL DMR-6700

Partial Discharge, Survey or Monitor?

Transcription:

IRIS POWER TGA-B Periodic Online Partial Discharge Monitoring Instrument for Turbine Generators and Motors

We have not found another test method that produces as much decision support data for generator stator maintenance planning based on actual in-service insulation condition... Analysts were able to recommend the needed corrective maintenance before the maintenance outages began. Partial Discharge Is A Leading Symptom Of Failures On Generator Stator Windings Insulation problems are one of the principal causes of forced outages for generators, motors switchgear and dry type transformers which result in considerable damage and lost revenues. Periodic online monitoring of partial discharge provides a cost effective and proven technique to minimize the risk of unexpected failures. Other 1% Bearing / Shaft 12% Rotator Winding 12% Avoid In Service Failures With Early Detection Of Failure Mechanisms FAILURE MECHANISMS FOR GENERATORS Allianz insurance, Survey 1996-1999 VDE Colloquium, June 28, 2001 Stator Winding 63% Stator Core 12% Partial Discharge monitoring has become an important tool for condition based maintenance on generators by identifying risks of failure caused by abrasion of insulation, loose stator windings, thermal degradation of insulation and manufacturing defects. Global Acceptance Of Online Partial Discharge Monitoring Partial discharges in degrading high voltage stator windings give rise to small voltage pulses which travel through the stator winding. The magnitude and number of these pulses depends on the degree of insulation deterioration. As the magnitude and number of partial discharge voltage pulses increase, the rate of electrical insulation deterioration is also increasing. Partial Discharge monitoring has won worldwide acceptance across utilities, major industrial companies and manufacturers. Iris Power has provided products for partial discharge monitoring on over 16,000 assets globally in addition to partial discharge monitoring being recommended in industry standards such as IEEE Standard 1434-2014 and IEC TS 60034-27-2:2012. Iris Power online partial discharge monitoring instruments have accurately identified problems on many hundreds of generators with hundreds of case studies and dozens of published papers by Iris Power customers that confirm Iris Power partial discharge monitoring instruments can help: Prioritize assets needing immediate maintenance Identify and repair damage at an earlier stage Avoid in-service failures Reduce outage frequency when results are good Obtain information regarding the type and location of maintenance required prior to outages Reduce overall cost of maintenance

Development Of Iris Power Partial Discharge Monitoring The development of Iris Power partial discharge testing instruments in 1990 s was funded by the North American utility industry (CEA and EPRI) to provide machine owners a method of detecting stator insulation problems and obtaining adequate data to make maintenance decisions independent of equipment manufacturers. The TGA-B was designed specifically for monitoring partial discharges under normal electrical, mechanical and thermal machine operating stresses without interference from external noise such as power system corona, output bus arcing or other common electrical disturbances. There are now over 65,000 Iris Power partial discharge Epoxy Mica Capacitive Sensors installed across thousands of motors, generators and metal glad switchgear globally that are monitored by Iris Power portable and continuous instruments. Sensor Installation and Configuration Iris Power Epoxy Mica Capacitors (EMCs) are 80pF capacitors that are used to block high voltage output from the generator since impedance is inversely proportional to frequency. The 60 Hz or 50 Hz power frequency is filtered with >30 MΩ impedance while the high frequency partial discharge pulses up to 250 MHz easily pass through the EMC with only 10 s Ω impedance. This allows us to see small partial discharge pulses of under 100 mv on rotating machines rated over 3.3kV. Iris Power typically installs two 80pF epoxy mica capacitive couplers per phase on generators. Noise pulses originating outside the machine arrive at the sensor closer to the power system first. Partial discharge pulses originating in the machine winding arrive at the sensor nearest the machine first. This allows the TGA-B to automatically distinguish between noise and winding partial discharge based onpulse arrival time. Motors with over 30m of cable the switchgear may require only one epoxy mica capacitor per phase. The TGA-B automatically analyzes the pulse shapes to separate distorted pulses originating from the power system from machine partial discharges. Epoxy Mica Capacitors Installed On Generator BUS Epoxy Mica Capacitors (80pF) Data Collection Method The online partial discharge test takes less than 30 minutes per machine with data collected in a simple, safe and non-destructive manner based on sound principles that are recommended by manufacturers and industry standards such as IEEE Std. 1434-2014 and IEC60034-27-2: 2012. The operator connects low voltage coaxial cable from the Iris Power PDA-IV portable instrument to a coupler termination box. The PDA-IV instrument is then connected to a control computer that runs the PDLight Pro and PDView software using a USB or Ethernet cable. The test is initiated through the PDLight Pro software which automatically collects the partial discharge data while the machine is running and without any interference to normal operation of the generator. Termination Box Control Computer Installed with PDLitePro & PDView Iris Power TGA-B

Data Analysis and Information Outputs Iris Power is foremost focused on providing a clear, reliable and repeatable result that allows the user to understand the true condition of the motor or generator and to make educated decisions on operations and maintenance. The TGA-B instrument has been designed to automatically collect partial discharge data and output the relevant information needed to provide a decisive means of: Identifying Partial Discharge Severity Identifying Probable Causes of Winding Deterioration Comparing Relative Health Across Machines Peak Partial Discharge Magnitude Peak pulse magnitude (Qm) values are automatically calculated by the PDA-IV instrument and output to help understand the relative health of each asset. The Qm value is defined in IEEE 1434 and IEC 60032-27-2 to allow several means of comparison including the following: Trending of Qm to show any major change in the rate deterioration of the stator winding insulation. Peak Partial Discharge Magnitude (Qm) Trend Graph Showing Increasing Rate of Partial Discharge Severity Comparison of generator condition against similar machines using the freely available Iris Partial Discharge Severity Tables which are composed of over 550,000 test results collected across most makes and sizes of machines. Machine Partial Discharge Electrical disturbances including partial discharges in the transmission lines (corona) or transformer as well as sparking of overhead cranes or on-site welding can create pulses similar to partial discharges. It is important to be able to understand the difference between power system noise and machine partial discharges to avoid false positive indications, to prevent unnecessary shut-downs and to avoid in-service failures. Phase Resolved Partial Discharge Plot showing pulse magnitude (mv) and frequency (pulses per second) by phase angle in the machine The Iris Power TGA-B is designed specifically for Turbine Generators and Motors to ensure machine partial discharges are viewed and analyzed separately from system noises. Separation of System Noise Installation of two couplers per phase allows the TGA-B instrument to automatically distinguish between power system noise by evaluating pulse shape and the time of arrival of pulses. Pulses originating outside the generator which arrive to the instrument through sensor closest to the system so can be automatically separated and classified as disturbances. Phase Resolved Partial Discharge Plot showing pulse magnitude (mv) and frequency (pulses per second) by phase angle from the system The pulses that arrive at the machine side sensor are automatically classified as machine partial discharges. Any pulses between the two sensors are automatically classified as pulses on the isolated phase bus.

Product Overview The Iris Power TGA-B instrument provides the most reliable and accurate portable partial discharge monitoring solution on the market that is designed specifically for motors and generators. Advanced noise separation based on pulse shape and time of arrival methods to consistently quantify and isolate partial discharges from system disturbances. Test frequency range from 40 MHz to 350MHz while working with 80 pf Epoxy Mica Capacitors (EMCs) and 2 MHz to 350 MHz with 1-2 nf capacitive couplers. Optional capability for offline partial discharge testing of individual stator bars, coils and windings. Ability to operate instrument from 12V battery pack Partial Discharge Pulse Measurement Software & Manual Frequency Bandwidth Phase Windows Pulse Amplitude Range Data Acquisition Time Resolution Ambient Sensors Sensor Compatibility 0.1 MHz - 350 MHz 100 phase windows per cycle 2 mv - 34,000 mv 10 Sensitivity Range Settings 5s per magnitude window 6ns for EMCs Ambient Temperature Sensor Ambient Humidity Sensor 80 pf EMC (6.9kV - 35 kv) - 6 Sensor Inputs PDLITEPRO Included PDVIEW Standard Edition Included PDVIEW Advanced Edition Optional User & Installation Manuals Included Testing And Certification Vibration Test IEC 60068-26 Shock Test IEC 60068-2-27 Operating Conditions Operating Temperature -15 o C to 45 o C ( 5 o F to 113 o F ) Relative Humidity Up to 95% non-condensing Accessories Included Power Supply Cord 1.8m ( 6 ft ) Power Supply Adapter Ethernet Cable AC Reference Cable Input: 100 240 VAC, 1.5A, 50 60Hz Output: 12 VDC, 5A 3m ( 10ft ) CAT-5 USB Cable 1.5m ( 5ft ) Impact Resistant Case 1.8m ( 6ft ) Shrouded Plug 41 cm x 31 cm x 21 cm (WxDxH) 16" x 12" x 8" (WxDxH) 10 kg (22 lbs) Transit Vibration MIL-STD 810G, Method 514 Electrical CE, UL Options Controlling Computer Sensor Compatibility VFD Motor Operation Low Frequency Test Details Available On Request Stator Slot Coupler (TGA-SB) Hydro EMC Couplers (TGA-BP) 20 Hz - 120 Hz Reference Circuit Capacitive Divider Offline Testing 80pF EMC 25kV or 28 kv 50 khz- 5 MHz

IRIS POWER LP 3110 American Drive Mississauga, ON, Canada L4V 1T2 Phone: +1-905-677-4824 Toll Free: +1-888.873.4747 Sales.iris@qualitrolcorp.com QUALITROL COMPANY LLC 1385 Fairport Road Fairport, NY, USA 14450 Phone: +1-585-586-1515 Fax: +1-585-377-0220 www.qualitrolcorp.com The TGA-B is a Trademark of Iris Power LP - a Qualitrol Company VER 8-9 / 16