Strain Gauge Measuring Amplifier BA 662

Similar documents
TVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active

Transducer transmitter BILT 4 II 2(1) G. Technical Manual

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5

MINI MCR-SL-UI-I-LP-NC

SY038 UNIVERSAL LOAD CELL AMPLIFIER

GSV-1H 010/250/2. Highlights

Installation and Operating Manual

Installation and Operational Instructions for ROBA -multiswitch Type 019._00.2

Operating manual. Force transducer with strain gage measuring system C9B. A en. hvordan man bruger astrologi med tibetanske medicin

Operating Manual MU2000K

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

Strain gauge amplifier

Operating manual. 600 Hz Measuring Amplifier ME30. A en

Installation and Operational Instructions for ROBA -switch Type 017._00.2

MCR-SL-CUC Universal current transducer. Data sheet _en_05. 1 Description

Force and strain sensors. Measure. Test. Control. Edition 2016

HAEHNE. Digital Strain Gauge Amplifier DMA2. Adjustment Instructions. Content

RAD-IN/OUT-8D. Digital extension modules for the bidirectional wireless system. INTERFACE Data sheet _en_05. 1 Description

Technical data Model F1301 F13C1 ATEX/IECEX 2) F13C1 (Option) Nominal load F nom 10 / 20 / 30 / 50 / 100 / 200 kn 10 / 20 / 30 / 50 / 100 / 200 kn 10

Tel: (949) Fax: (949) IAA100 Product Manual

LCT100. Load Cell Tester User s Guide (v1711) Anyload Transducer Co. Ltd Website:

Industrial motor controller for brushed DC motors 24 VDC

Industrial motor controller for brushed DC motors 12 VDC

Module Input type Ranges TEDS Filters (LP = lowpass, HP = highpass) Piezoresistive bridge ±0.5 to mv/ma 1 ma exc

Transducer for Measurement Bridges SCM90, SIGS15

Series 7000 Torque Sensor for PTO-shafts

Analogowy przetwornik wzmacniający dedykowany dla czujników tensometrycznych RQA INSTALLATION MANUAL. Rev. 0.2

Digital amplifier for proportional valves PEM XD

User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters

SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS

MODEL AT-10 ANALOG TRANSMITTER

OPERATION MANUAL ELECTRONIC FREQUENCY CONVERTER HFO E

Low Noise Variable Gain Low Frequency Voltage Amplifier

OPERATION MANUAL ELECTRONIC FREQUENCY CONVERTER HFO-E

USER S MANUAL POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER ZSP 41 POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER SIGNAL MULTIPLIER ZSP 41/2

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

Technical data. Your advantages

Operating instructions Switching amplifier for fibre optics. OBF5xx / / 2009

MACX MCR-UI-UI-UP(-SP)(-NC)

Torque Sensor Series 3000 and Series 4000

Low Noise Variable Gain Low Frequency Voltage Amplifier

WS12EX Position Sensor with Analog output Dust explosion-proof

User manual. Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD

electronics Data Sheet Industrial Amplifier Special features Dimensions (in mm; 1 mm= inches) B en

LOW VOLTAGE CONVERTER WITH THREE POINT GALVANIC INSULATION

Voltage Transient Emission Test

High Speed Strain Gauge Amplifier/Isolator User Manual

400,440Vac Vdc V, A, W, VA, var, Hz, V, Avg. A cos phi, sin phi and phi measurement kwh, kvarh (via Pulse Output)

Conductivity Transmitter N-LF V AC

CSG110 Strain Gauge Universal Amplifier

MINI MCR-SL-UI-f(-SP)

Inductive sensor slot-type SI2-K08-AP7

Embedded Strain Gauge and Load Cell Signal Conditioner/Amplifier v.2.3

ICA User Manual ICA. ICA Embedded Strain Gauge Analogue Amplifiers

SUNSTAR 传感与控制

ECM3 EARTH CONTINUITY RELAY

GESTRA Steam Systems LRS English. Installation & Operating Instructions Conductivity Switch LRS 1-50

User manual. Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD

Overview of types. Technical data

BC145 SIGNAL ISOLATOR BOARD

User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters

Multichannel amplifier Model 9235/36

SGIM Strain Gauge Input Module. user manual

ICAM. Electronics & Software. Industrial Charge Amplifier for Applications in Manufacturing. Type 5073A...

Operating Manual. GV210 Encoder distributor, cross switcher and splitter for incremental encoder signals. Product Features:

PHOENIX CONTACT

Level Switch NRS 2-50 NRS Original Installation Instructions English

12/4/ X3 Bridge Amplifier. Resistive bridge amplifier with integrated excitation and power conditioning. Logos Electromechanical

WIRELESS INSULATOR POLLUTION MONITORING SYSTEM

DUAL CHANNEL BROADBAND LINEAR AMPLIFIER Model A800D

Power supply CP-E 24/0.75

Characteristics and functioning

ADAM Isolated DC Input/Output Signal Conditioning Module. User s Manual

EY-EM 527: Remote I/O module, ecolink527

Mounting instruction and operating manual. Access Point (UK) HmIP-HAP-UK

Technical Manual TRANSDUCER AMPLIFIER TYPE DR7AC. Doc. Ref CD2402K

Operating Manual Series Load Pins

Trip amplifier, 1 channel

Power supply CP-D 24/1.3

Brunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2

RENATO DESIRÒ PARABIAGO (MI) Via Sant Anna, 51 Tel Fax

INSTALLATION MANUAL. Model: Smart Analyzer Manufacturer: Smart Impulse. Power meter with consumption breakdown by use 03/12/13

EY-EM 522, 523: Remote I/O module, ecolink522, 523

GFL-1000 User Manual Ground Fault Locator

Installation / Monitoring Technique

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

7.2 DV1311.L08 and DV1311.L12

USER MANUAL. WBP314P71 active power transducer. (3-phase 4-wired)

EPA152/252/502. User Manual.

Valve amplifier for proportional pressure valves

Digital Function Generator

BROADBAND LINEAR AMPLIFIER Model P150

Emergency lighting units EM powerled

Resistance thermometer Model TR31, miniature design

21 VA (l max 20 5 ms) Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque Inhibiting torque

ARD154. DIN rail mountable amplifier for strain gage sensors. User s guide. User s guide ARD CONNECTING 4-WIRE SENSORS

TxBlock-USB Transmitter

Type CP-S, CP-C & CP-A Switch mode

Original operating instructions Fail-safe inductive sensor GG507S / / 2013

Protection components

Transcription:

Strain Gauge Measuring Amplifier BA 662 Original of the Manual Table of Contents 1. Safety precautions... 2 1.1. Field of application... 2 1.2. Installation... 2 1.3. Maintenance... 2 2. Function... 2 3. Specifications... 3 3.1. General technical data... 3 3.2. Circuit diagram... 4 3.3. Dimensions... 4 3.4. Connections... 5 3.5. How to connect signal output... 5 3.6. Trigger input... 5 4. Operation... 6 4.1. Overview operating elements BA662/IP20... 6 4.2. How to operate the keys... 6 4.3. Amplification... 6 4.4. Zero alingment... 7 4.5. Filter... 7 4.6. Signal output... 7 4.7. LED Status... 8 4.8. Restart... 8 4.9. Factory setting (RESET)... 8 5. Using the Software ASTAS (USB)... 8 6. EC Declaration of Conformity... 9 Technical changes reserved. 09/2016 Page 1 of 10

1. Safety precautions In this operating manual, the installation, putting into operation and the operation itself of the Strain Gauge Bridge Amplifier BA 662 is described. It is assumed that all measures are taken by qualified staff only who have adequate knowledge in the fields of measuring and control engineering. ATTENTION! Any non-compliance with these safety precautions may result in severe damage to property and health. 1.1. Field of application The Strain Gauge Bridge Amplifier BA 662 has been designed to the purpose of amplifying the output signals of sensors with metal-foil strain gauges, preferably force transducers and transform them into standard signals. Any other application is regarded contrary to the intended purpose. The manufacturer does not accept any liability for damages resulting from such inappropriate usage. In this case it is the user alone who has to bear the risk. Type BA 662 must not be used as the sole means to prevent dangerous conditions of machines and plants. All machines and plants must be constructed in such a way (e.g. by using mechanical stops, limit switches) that a condition of failure does not result in a situation of severe danger. It must be made sure that any erroneous setting or malfunction of the unit or its breakdown cannot cause damage or be a risk to the operating staff or other persons. 1.2. Installation The unit must be installed and connected in compliance with the current DIN- and VDEstandards. Supply cables and signal lines shall be installed so that interference signals such as electrical interference do not have any adverse effects on the function of the equipment. 1.3. Maintenance The device does not contain any components that require maintenance. Repairs shall be carried out by the manufacturer only. 2. Function The Strain Gauge Bridge Amplifier BA 662 is a digital amplifier for the low-drift amplification of the output signals of sensors with metal-foil strain gauges, preferably force transducers to supply a standard signal of (-10/0...10) VDC or (0/4...20) ma. An internal voltage source provides the stabilized feeding voltage for the sensor. The power is supplied by an unstabilized source of (9...36) VDC. The Strain Gauge Bridge Amplifier is delivered in a case for standard rails in accordance with DIN EN 50022-35. The BA 662 is delivered with a factory setting for an input signal of 2mV/V and a corresponding output signal of ± 10V or 20mA. The other input signal ranges 0.1mV/V to 7mV/V can be generated internally from the 2mV/V factory adjustments. The different settings of the factory adjustments (zero point and gain) can be changed by the user through keys. By an optically separated input, the zero-setting can be carried out by means of a superior control and through the trigger input. The overload limit is not affected by such a zeroing, which means that 100 % of the end-value adjustment of the sensor remains as end value. An existing preload by a container can thus be set zero. Page 2 of 10 Technical changes reserved. 09/2016

3. Specifications 3.1. General technical data Class of accuracy at input signal 2mV/V Connection for strain gauge sensor Bridge resistance / range of input impedance Input signal range (+Si/-Si) % FSR < 0.02 (typ.) Ω mv/v 4- or 6-wire 58...2000 (up to 6 loadcells each 350 Ω) 0.1 / 0.25 / 0.5 / 1.0 / 1.5 / 2.0 / 3.0 / 4.0 / 5.0 / 7.0 ±2.5 Excitation voltage (+Ex/-Ex) VDC Norm Output Current Output ma 0/ 4... +20; 0 24 Voltage Output V Load resistance Ω 500 Measurement Characteristics Conversion rate Hz 6. 3200 Resolution of the A/D Converter Bit 24 Filter Hz 0.8 2000 Error at S=2mV/V Nonlinearity Noise (at measurement rate) Input sensitivity for 1 LSB Zero drift Power Supply Input range Power consumption (without sensor) Environmental Conditions Operating temperature range Storage temperature range Construction Weight Dimensions (W x H x D) Environmental protection (EN 50529) Terminal block, wire size %FSR %FSR nv %/ 10K VDC W C C kg mm mm² -10/-5...0 +5/ +10 1000 0.0025 0.002 (0.8Hz) 0.009 (2000Hz) 150 <0.01 9... 36 1-20...+ 60-25...+ 85 Plastic housing for DIN-rail mounting 0.2 22.5 x 114.5 x 99 IP 20 0.14 2.5 *Software - Download over www.ast.de Technical changes reserved. 09/2016 Page 3 of 10

3.2. Circuit diagram Sensor Power supply 9... 36VDC 0V +Se +Ex +Si -Si 2.Stab A D C 1.Stab μc 16-Bit -DAC ±12V Output I Out VOut AG -Ex -Se Shi 2. Stab EMC-Filter Filter DIP -Switcher (Config. DAC ) T+ 24VDC T - 0V USB: (ASTAS*, Configuration DAC, Filter) 3.3. Dimensions 99 114,5 Filter (Hz) 156 67 25 8,3 2,4 0,8 Output 385 625 1315 2000 0... 10V 0... 5V -10... +10V -5... +5V 0... 20mA 0... 24mA 4... 20mA +Si -Ex -Si NC SHI -Se +Se +Ex 6-Wire 4-Wire 0.5 1.0 mv/v 0.25 1.5 0.1 2.0 7.0 3.0 5.0 4.0 Reset USB BA 662 + 100% - + 0% - 22,5 Status AG 24V 0V V OUT I OUT Tr- NC Tr+ Page 4 of 10 Technical changes reserved. 09/2016

3.4. Connections Terminal connection -Ex -Se +Se +Ex +Si -Si NC SHI AG V out I out NC 24V 0V Tr+ Tr- Description neg. Exitation voltage neg. Sense signal pos. Sense signal pos. Exitation voltage pos. Signal neg. Signal not connected Shield Ground for output signal Voltage output Current output not connected Supply voltage Supply voltage ground Trigger 24V Trigger 0V Sensor with 6-wire Outuput signal Power supply electrically isolated input Installation recommendations Use shielded cables. Use the largest possible cable cross section (Error due to cable extension). Lay the measuring lines separately from the power supply lines. At the force transducers and the measuring amplifier, make as short as possible a connection to earth, in particular in strong electromagnetic fields. Additionally, lay an equipotential bonding parallel to the measuring line. Keep away from stray fields of motors, transformers and contactors. Connect force transducers, amplifier, mains unit, and indicator / processor unit with earth in one place only. Set the slide switch for the sensing line (6- or 4-wire) according to the sensor connection. 3.5. How to connect signal output The Bridge Amplifier BA 662 provides different output signals, depending upon the setting of the slide switches. (see 4.6) NOTE Either the current output or the voltage output can be used, not both at the same time. TIP: o form the sum, current outputs of several BA662 can be connected in parallel. In this case, 12V should not be exceeded at the standard output and the maximum load (load resistance) be <12V / I Out.Voltage outputs must not be connected in parallel. 3.6. Trigger input The BA662 has an optically separate trigger input so that the zero-setting can be carried out by means of a superior control. The overload limit is not affected by such a zeroing. The function is started by a 24 VDC trigger impulse. Note! The measuring amplifier is protected against reverse polarity. Technical changes reserved. 09/2016 Page 5 of 10

4. Operation 4.1. Overview operating elements BA662/IP20 BA 662 6-Wire 4-Wire 0.5 1.0 mv/v 0.25 1.5 0.1 2.0 7.0 3.0 5.0 4.0 Reset USB Status + 100% - + 0% - Connection Sensitivity/ measuring range of sensor in mv/v Amplification Push simultaneous: Load calibration Factory setting (RESET) Zero: Push simultaneous: Zero calibration LED: Status Filter (Hz) 156 67 25 8,3 2,4 0,8 Output 385 625 1315 2000 0... 10V 0... 5V -10... +10V -5... +5V 0... 20mA 0... 24mA 4... 20mA 4.2. How to operate the keys Keys individually / short: Keys individually / long (2s): Setting of the signal output Fast setting of the signal output 4.3. Amplification Switch position 0 1 2 3 4 5 6 7 8 9 Measuring range (mv/v) 0,1 0,25 0,5 1,0 1,5 2,0 3,0 4,0 5,0 7,0 >100% +< and >100% -< simultaneously (2s): Adjustment of the present input signal (currently applied force) to100% of the output signal (end-value adjustment). By individually pushing the keys >100% +< or >100% -< respectively, an individual fine adjustment of the output signal / the end value is possible. NOTE In case of changing the amplifier output by means of keys > 100 % +< or > 100% -< there should always be a zero-alignment check. NOTE Amplification-values are saved permanently 7 seconds after last push button action. During saving LED blinks for a short time. Page 6 of 10 Technical changes reserved. 09/2016

4.4. Zero alingment >0% + < and >0% - < simultaneously (2s): Setting of the present input signal at the output to zero point (zero-adjustment/ zero-alignment) By individually pressing the keys >0% +< or >0% -< respectively, an individual fine adjustment of the output signal / the zero point is possible. NOTE! Zero-values are saved permanently 7 seconds after last push button action. During saving LED blinks red for a short time. 4.5. Filter Through a low-pass filter, the output signal can be set in 10 stages, from 0.8 to 2000Hz. Filter (Hz) 0,8 2,4 8,3 25 67 156 385 625 1315 2000 Internal Sample rate (Hz) 6 12 25 50 100 200 400 800 1600 3200 4.6. Signal output DIP-switch explanation: DIP-switch function: - OFF - 3 2 1 0 +10V 0 + 5V -10 +10V -5 + 5V 0 20mA 0 24mA 4 24mA ATTENTION! In case of exceedance of the input signal of >-120%, the analogue output is set to the maximum positive initial value. In case the input signal lies in the range between -120% and 0%, the minimum analogue signal is released at the unipolar voltage output and the current output respectively (see too 4.7). output bipolar (U) output unipolar (U/I) -120% 120% Input -120% 120% Input Sensor mv/v Graph 1 Output signal in case of error (bipolar) Output signal -5 5V, -10 10V Graph 2 Output signal in case of error (unipolar) Output signal 0 5/10V, 0/4 20/24mA Technical changes reserved. 09/2016 Page 7 of 10

4.7. LED Status LED display Explanation Error description Green Ready for operation No error Red 1 x flashing ADC-Overload Error at connections of sensor lines Cable break in sensor line Switch for 6- and 4-wire not accordingly connected Red 2x flashing Indicates overload Exceed of maximum load of 120% of nominal or underload sensitivity, or exceed minimum load (see too 4.6) Red 3x flashing TEDS error Error in the memory of the automatic sensor recognition (only option with TEDS) Red 4 x flashing Output > 100% The amplification at the output is set too high. Red 5 x flashing Output side not closed Current output open Cable break at output or overheating DAC Thermal overheating - cooling necessary Red 6 x flashing Hardware error General error restart necessary 4.8. Restart 100% - and >0% +< simultaneously: A restart is carried out. All settings are saved. 4.9. Factory setting (RESET) For all ten sensitivity settings / measuring ranges (see 4.1 sensitivity in mv/v of the sensor) factory settings are stored in the amplifier. Individual adjustments of the amplification (see 4.3.) or of the zero point (see 4.4) carried out later by the user, do only influence the active measuring range that has just been set. When simultaneously pushing the two keys >100% +< and >0% -< for 2s, all zero-point adjustments and end-value adjustments of all ten measuring ranges are deleted and reset to the factory settings of 0mV/V initial value of the selected signal output (-5/-10/0V or 0/4mA) and 2mV/V end value of the selected signal output (5/10V or 20/24mA). NOTE! After reset to factory settings, the amplifier has to be newly adjusted to the sensor! 5. Using the Software ASTAS (USB) Load the software from our website www.ast.de TIP: Linearization: If the measured values between zero and rated load should deviate from the real load, up to four additional points can be set to increase the measurement accuracy. These measuring points can be made in any order, similar to the input of the zero point and end point. After entering all of the calibration points, the result must be stored. Page 8 of 10 Technical changes reserved. 09/2016

6. EC Declaration of Conformity Technical changes reserved. 09/2016 Page 9 of 10

Page 10 of 10 Technical changes reserved. 09/2016