R/C SMD Tweezers Multimeter Model RC200

Similar documents
User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

USER'S MANUAL DMR-6700

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

Compact MultiMeters + Voltage Detector

Autoranging Multimeter Extech EX503

400Amp True RMS AC Clamp Meter + NCV

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

400Amp True RMS AC/DC Clamp Meter Model EX613

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

User's Guide Extech EX Amp Clamp Meter with IR Thermometer

200Amp AC Clamp Meter + NCV Model MA250

DL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter

User s Guide. 400A AC/DC Clamp Meter. Model MA220

User Guide. AC/DC Mini Clamp Meter. Model

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

AUTORANGING TRUE RMS MULTIMETER USER GUIDE. INST151 Doc 1.00

400Amp True RMS AC/DC Clamp Meter with IR Thermometer Model EX623

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

USER MANUAL. Model MA A AC Mini Clamp-on Meter. Additional User Manual Translations available at

User s Guide. Model MA A AC Mini Clamp-on Meter

Model True RMS AC/DC 30A Mini Clamp-on Meter. User Guide

EX360 Series USER MANUAL. True RMS Digital Multimeters. EX360 True RMS Digital Multimeter EX363 True RMS DMM with Temperature and µa AC/DC

USER S MANUAL DMR-1500

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

User's Guide. Extech 800 Series 1000 Amp Clamp Meters with IR Thermometer

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)

Pen-type DIGITAL MULTITESTER

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

OPERATING INSTRUCTION

USER'S MANUAL DMR-4350

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

User s Guide. Digital AC/DC Clamp Meter Model 38394

Not for Reproduction

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

PeakTech 3355 / 3360

User Guide. Digital AC/DC Clamp Meter Model 38394

USER'S MANUAL DMR-4300

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

MM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS

Operating Instructions 22070T True RMS AC/DC CLAMP METER Instrucciones de uso. Pinza amperimétrica de CA/CC de RMS verdadera

MULTIMETRE DIGITAL 3 3/4 AVEC ECHELLE AUTOMATIQUE & EXTINCTION AUTOMATIQUE MANUEL D UTILISATION

User Manual 4 wire Earth Resistance Tester Model GRT300

User Guide. 4 wire Earth Resistance Tester Model GRT Washington Street Melrose, MA Phone Toll Free

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

AC/DC CLAMP METER USER S MANUAL

Safety. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present.

Passive Component LCR Meter

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

USER'S MANUAL DMR-2400

DM-45 Digital Multimeter

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

OWNER S MANUAL HH0308C. AUTO-RANGING DC/True RMS AC DIGITAL MULTIMETER

OPERATOR S INSTRUCTION MANUAL

USER MANUAL. Extech EX850 True RMS 1000 Amp Clamp Meter. Bluetooth TM and Android TM ready. Patented

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

USER MANUAL. Model MA A AC Clamp Meter DMM Model MA445 True RMS 400A AC/DC Clamp Meter DMM

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

AMM-1022 Digital Multimeter USER`S MANUAL

Micro-Ohmmeter Model UM200

MODEL: D03128 CLAMP METER

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

Digital Clamp Meter Model: &

KMD-S04 Multímetro de bolsillo

DIGITAL CLAMP METER Use s Manual

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

User s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130

Sales: Technical: Fax:

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

Mini Clamp Meter Model:

USER'S MANUAL. ACD-6 Pro. ACD-6 TRMS Pro. Versatile Clamp-on Multimeter Series

USER GUIDE. Extech EX850 True RMS 1000 Amp Clamp Meter. Bluetooth TM and Android TM ready. Patented

NOTE: Fully read and understand this manual before using this Digital Multimeter.

User Manual Digital Multimeter. model no.: MSR-U1000

DDM350 Pen-Type Digital Multimeter User s Manual

UT207A/208A/209A Operating Manual. Table of Contents

User Manual Digital Multimeter

User Manual. All rights reserved. Specifications are subject to change without notice.

User Manual. All rights reserved. Specifications are subject to change without notice.

Pen Multimeter. Model

CONTENTS MS2033A. 1.Introduction Safety Information...01

Item ref: UK MTM01 DIGITAL MULTITESTER. User Manual

1. SAFETY 1.1. SAFETY INFORMATION 1.2. SAFETY SYMBOLS

600A Clamp Meters w/tightsight Display

Digital Clamp Meter. User Manual

Pocket Size Digital Multimeter Models: and

ET-3888 True RMS Clamp Meter. User Manual

INSTRUCTION MANUAL ACD-10 PRO & TRMS PRO

DM-46 Instruction Manual

USER'S MANUAL AM-100 AM-105 TRMS AM-110 TRMS. Digital Multimeters

DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD 10A COM LIGHT MS8265 ON/OFF. 200M KHz 2K 20K μ μ μ n.

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

Model UT10A: OPERATING MANUAL Table of Contents (1)

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

DVM1190 DIGITAL MULTIMETER

Transcription:

User's Guide R/C SMD Tweezers Multimeter Model RC200

Introduction Congratulations on your purchase of the Extech RC200 RC Tweezers Multimeter This meter, using the tweezers adaptor, measures SMD capacitors, resistors, diodes and continuity test. With the test lead adaptor, it measures AC/DC Voltage. Proper use and care of this meter will provide many years of reliable service. Safety INTERNATIONAL ELECTRICAL SYMBOLS! Caution! Refer to the explanation in this Manual Caution! Risk of electric shock Earth (Ground) Double Insulation or Reinforced insulation This meter has been designed for safe use, but must be operated with caution. The rules listed below must be carefully followed for safe operation. 1. NEVER measure voltage with the Tweezer adaptor installed. 2. NEVER apply voltage or current to the meter that exceeds the specified maximum: Input Protection Limits Function Maximum Input V DC or V AC 600V DC/AC 3. USE EXTREME CAUTION when working with voltages greater than 25VAC or 35VDC. These voltages are considered a shock hazard. 4. DO NOT measure voltage if the voltage on the "COM" input jack exceeds 600V above earth ground. 5. NEVER connect the meter leads across a voltage source while the function switch is in the capacitance, resistance, or diode mode. Doing so can damage the meter. 6. ALWAYS discharge filter capacitors in power supplies and disconnect the power when making capacitance, resistance, continuity or diode tests. 7. ALWAYS turn off the power and disconnect the test leads from the circuit before opening the cover to replace the batteries. 8. NEVER operate the meter unless the battery cover is in place and fastened securely. 9. NEVER operate the meter if any part is damaged. 10. ALWAYS turn the meter off when not in use. 2

Description 1. LCD display 2. RANGE button 3. MODE and Power button 4. Spacing adjustment 5. Tweezer contacts 6. Voltage adaptor 7. Batter compartment (rear) 1 2 3 4 5 7 6 LCD Display Symbols Low battery Continuity Diode >30V caution icon. n nano (10-9 ) (capacitance) µ micro (10-6 ) (amps, cap) m milli (10-3 ) (volts, amps) k kilo (10 3 ) (ohms) F Farads (capacitance) M mega (10 6 ) (ohms) Ω Ohms V Volts AC AC voltage DC DC voltage AUTO Auto Range SCAN SCAN mode APO Auto power off enabled 3

Operating Instructions WARNING: Risk of electrocution. High-voltage circuits, both AC and DC, are very dangerous and should be measured with great care. 1. If OL appears in the display during a measurement, the value exceeds the range you have selected. Change to a higher range. 2. The meter will automatically recognize if the voltage test leads or tweezers adaptor is inserted. 3. The meter will turn on with autoranging AUTO selected. In this mode, the unit will automatically select the proper range to measure the device under test. Press the RANGE button to go to manual ( MANU ) ranging. Continue pressing the button until the range desired is selected. Press and hold the RANGE button for two seconds to return to autoranging. 4. On some low AC and DC voltage ranges, with the test leads not connected to a device, the display may show a random, changing reading. This is normal and is caused by the high-input sensitivity. The reading will stabilize and give a proper measurement when connected to a load. Test Lead AC/DC Voltage Measurements 1. Insert the voltage adaptor into the meter observing the polarity indicators. 2. Press the MODE button for 2 seconds until the meter beeps. V will be displayed on the LCD 3. Press the MODE button to select either AC or DC voltage. 4. Touch the black test probe tip to the negative side of the circuit. Touch the red test probe tip to the positive side of the circuit. 5. Read the voltage in the display. Note: The DANGER symbol will appear in the display whenever the measured voltage exceeds 30V WARNING: To avoid electric shock, disconnect power to the unit under test and discharge all capacitors before taking any capacitance or resistance measurements. Remove the batteries and unplug line cords. Tweezer Resistance, Capacitance, Continuity and Diode Measurements. 1. Insert the tweezers adaptor into the meter observing the polarity indicators. 2. Press the MODE button for 2 seconds until the meter beeps. The meter turns on in the SCAN mode and - - - - on the display. 3. Insert a component into the tweezers contacts. In the SCAN mode, the meter automatically selects the proper range and units (Capacitance or Resistance). 4. Read the measurement results in the display. 5. Press the MODE button to exit the SCAN mode and begin resistance measurements. The Ω icon will appear on the display. 6. Press the MODE button for continuity measurements. The icon will appear on the display. The meter will beep if the resistance is less than the continuity threshold. 7. Press the MODE button for diode measurements. The icon will appear on the display. A good diode will read OL in one direction and a low voltage in the opposite direction. 8. Press the MODE button for capacitance measurements.the F icon will appear on the display. It can take several minutes for the reading to stabilize at the final value for large value capacitors. 9. Press the MODE button again to return to the SCAN mode. 4

Power OFF and Auto Power OFF Press and hold the MODE button for 4 seconds to manually turn power off. The auto off feature will automatically turn the meter off after approximately 10 minutes of inactivity.. Low Battery Indication The icon will appear in the display when the battery voltage becomes low. Replace the battery when this appears. Maintenance 1. KEEP THE METER DRY. If it gets wet, wipe it off. 2. USE AND STORE THE METER IN NORMAL TEMPERATURES. Temperature extremes can shorten the life of the electronic parts and distort or melt plastic parts. 3. HANDLE THE METER GENTLY AND CAREFULLY. Dropping it can damage the electronic parts or the case. 4. KEEP THE METER CLEAN. Wipe the case occasionally with a damp cloth. DO NOT use chemicals, cleaning solvents, or detergents. 5. USE ONLY FRESH BATTERIES OF THE RECOMMENDED SIZE AND TYPE. Remove old or weak batteries so they do not leak and damage the unit. 6. IF THE METER IS TO BE STORED FOR A LONG PERIOD OF TIME, the batteries should be removed to prevent damage to the unit. BATTERY INSTALLATION 1. Turn power off. 2. Open the rear battery cover by removing the two Phillips head screws located on the rear of the meter. 3. Insert the batteries into battery holder, observing the correct polarity. 4. Put the battery cover back in place. Secure with the screws. 5. You, as the end user, are legally bound (Battery ordinance) to return all used batteries and accumulators; disposal in the household garbage is prohibited! You can hand over your used batteries / accumulators at collection points in your community or wherever batteries / accumulators are sold! Disposal: Follow the valid legal stipulations in respect of the disposal of the device at the end of its lifecycle NOTE: If your meter does not work properly, check the batteries to make sure that they are still good and that they are properly inserted. 5

Specifications Function Range Resolution Accuracy DC Voltage 600mV 0.1mV 6V 0.001V ±(0.8% reading + 2 digits) 60V 0.01V 600V 0.1V ±(1.0% reading + 4 digits) AC Voltage 600mV 0.1mV 50 to 60Hz 6V 0.001V ±(1.0% reading + 4 digits) 60V 0.01V 600V 0.1V ±(1.2% reading + 6 digits) Resistance 600Ω 0.1Ω 6kΩ 0.001kΩ 60kΩ 0.01kΩ ±(1.5% reading + 8 digits) 600kΩ 0.1kΩ 6MΩ 0.001MΩ 60MΩ 0.01MΩ ±(2.5% reading + 8digits) Capacitance 6nF 0.001nF ±(5.0% reading + 50 digits) 60nF 0.01nF ±(5.0% reading + 7 digits) 600nF 0.1nF 6μF 0.001μF 60μF 0.01μF ±(3.0% reading + 5 digits) 600μF 0.1μF 6mF 0.001mF 60mF 0.01mF ±(10% reading + 10 digits) NOTE: Accuracy is stated at 18 o C to 28 o C (65 o F to 83 o F) and less than 75% RH. Diode Test Test current 1mA, open circuit voltage 3V DC typical Continuity Check Audible threshold 10 to 40 ohms. Input Impedance 10MΩ (VDC & VAC) AC Response Average responding ACV Bandwidth 50Hz to 60Hz Display 6000 count liquid crystal Overrange indication OL is displayed Polarity Automatic (no indication for positive); Minus (-) sign for negative Auto Power Off 10 minutes (approx) Low Battery Indication is displayed if battery voltage drops below the operating voltage Batteries Two button batteries, AG13/LR44 or equivalent Battery life Approximately 60 hours Operating Temperature -10ºC to 50ºC (14ºF to 122ºF) Storage Temperature -30 o C to 60 o C (-4 o F to 140 o F) Operating Humidity Max 80% up to 31ºC (87ºF) decreasing linearly to 50% at 40ºC (104ºF) Storage Humidity <80% Operating Altitude 2000 meters (7000ft) maximum. Weight 65g (2.3oz) Size 181 x 35 x 20mm (7.1 x 1.4 x 0.8 ) Safety For origin of installation use and in accordance with the requirements for double insulation per EN61010-1 and IEC61010-1 2 nd Edition (2001) to Overvoltage Category III 600V; Pollution Degree 2. Copyright 2011 Extech Instruments Corporation (a FLIR company) All rights reserved including the right of reproduction in whole or in part in any form. 6