DUAL 4-20 MA NETWORK BRIDGE. Voltage. Regulator. Neuron CPU. Ohm Sense Resistor. Model 1400A Block

Similar documents
NEUROLOGIC RESEARCH CORPORATION

DESCRIPTION MODEL 1450 NOTE

DESCRIPTION NOTE. Power Supply MODEL 2200A PM

DESCRIPTION NOTE MODEL 2200VM

A local 3.5 mm network jack allows a convenient way to connect an installation or diagnostic tool to the network without disconnecting any wires.

PolyGard Digital Transmitter DGC DT-02

Lonbox PIO4014 Users Manual

FTT-10A Free Topology Twisted Pair Transceiver Model 50051

n FRONT PANEL CONFIGURATIONS

Functional Profile. SOMFY animeo LON Sensor Interface WM Ref

Nemo 96HD/HD+ LONWORKS

Tel: (949) Fax: (949) IAA100 Product Manual

LRI 5133/10 - Helio Multi-Sensor

H LONTalk Integration Node For Use With Enercept H8036 Power Meters H NOTICE DANGER INSTALLATION GUIDE METER DATA NETWORK VARIABLES

Excel 15 S7760A COMMAND DISPLAY

LONMARK Functional Profile: Air Velocity Sensor

A2000 Multifunctional Power Meter LON-Interface

SMX Transceivers Models 77010, 77030, 77040, 77050, and 77162

Castle Creations, INC.

Installation & Operation Manual

Non-Submersible Industrial Pressure Transducer

PolyGard DGC DT-1110-interoperable Electrochemical carbon monoxide transmitter LON interoperable serial no. DT-S 005 User Manual Preliminary Edition

RH/RHT Series. Relative Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies. Features

Applications: Power generation, Cogeneration, Stationary power Large engines

Isolated High Level Voltage Output 7B22 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Materials (other materials see WIKA diaphragm seal program) Model S-10

No-Contact, CANbus Rotary Position Sensor NRH27C

HI 2204LT Loop Powered Level Weight Transmitter OPERATION AND INSTALLATION MANUAL

Functional description "BIU-2ILT"

R7L-YV2. DC VOLTAGE OUTPUT MODULE, 2 points MODEL BEFORE USE... POINTS OF CAUTION COMPONENT IDENTIFICATION INSTRUCTION MANUAL R7L-YV2

Functional Profile. SOMFY animeo LON RTS Module 433 MHz WM Ref SOMFY animeo LON RTS Module 447 MHz WM Ref

Industrial Modbus I/O Modules

Isolated, Linearized Thermocouple Input 7B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Thermocouple Input 7B37 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Software Description SRCN_HWL_9_1_03 for SRC 04 FTT and SRC 65 FTT

Isolated, Linearized RTD Input 7B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Compact I/O Module XIO-8AI UNIVERSAL ANALOG INPUT MODULE

USB-TEMP and TC Series USB-Based Temperature Measurement Devices

Modus M Series. General Eastern Differential Pressure Transmitters. GE Sensing

Series T. Amphenol Advanced Sensors. Differential Pressure Transmitters

PRELIMINARY. Preliminary TECHNICAL DATASHEET #TDAX DC MOTOR CONTROLLER P/N: AX100650

User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters

Relative Humidity & Temperature Transmitters

Programmable with Electronic Assistant Simulink

READ THESE INSTRUCTIONS BEFORE YOU BEGIN INSTALLATION. Ground yourself before touching board. Some components are static sensitive.

WIRELESS MODBUS GATEWAY WGW410

ECL-VAV-N. Features & Benefits

Ordering Part Numbers: SAE J1939 version Controller: AX022400

PEAKTRONICS AMC-103 ADDITIONAL FEATURES. AC Motor Controller, 2A AMC-103 AMC-103A AMC-103B

TECHNICAL DATASHEET #TDAX Universal Signal Inputs CAN Controller V, ma, Digital, PWM, Hz/RPM, Counter Inputs CANopen P/N: AX030121

Freescale Semiconductor Data Sheet: Technical Data

CSG110 Strain Gauge Universal Amplifier

Model 144H NEW. PC-Programmable Temperature Transmitter. Product Data Sheet

MODEL AT-10 ANALOG TRANSMITTER

Communications & Networking

BusWorks 900EN Series Modbus TCP/IP 10/100M Industrial Ethernet I/O Modules

Part Numbers. SNAP-AIARMS-i SNAP-AIARMS-i-FM* SNAP-AIVRMS-i SNAP-AIVRMS-i-FM* SNAP-AIMA-i. SNAP-AIMA-iSRC SNAP-AIMA-iSRC-FM* SNAP-AIMA2-i

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

LON I/O Module DR-N MCU4-AC Art. no.: MTN881811

TECHNICAL DATASHEET #TDAX CAN SAE J1939, Dual Output Valve Controller

ROC800-Series HART Module

Selecting and Using High-Precision Digital-to-Analog Converters

ph or ORP Transmitter

FC-33, DC SELECTABLE SIGNAL CONDITIONER

Humidity Sensor/Transmitter Assembly

Software description LON bus

Uni-Mux XQL Multi-Channel Data Acquisition Module

Excel 10 W7761A Remote Input/Output Device

TECHNICAL MANUAL. SERIES AP5103 DIN-Rail DC Strain Gage Conditioner ISO 9001/AS9100

ADAM Isolated DC Input/Output Signal Conditioning Module. User s Manual

Isolated, Frequency Input 5B45 / 5B46 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Technical Data Sheet. Sensoric 4-20 ma Transmitter Board

Hardware Manual. PCD3.F240/PCD2.F2400 LON interface module for TP/FT-10 channel. Hardware Manual PCD3.F240/PCD2.F2400, LON interface module

Sensor Interfacing and Operational Amplifiers Lab 3

Fan-coil intelligent unitary controller

Penny & Giles No-Contact, Rotary Position Sensor NRH271 & NRH272

P/N: AX Applications: Off-highway construction equipment Municipal vehicles. Ordering Part Numbers:

TECHNICAL DATASHEET #TDAX022420

DCM20 Series. Three-Function DC Power Meters. DCM20 DISPLAY PRODUCT OVERVIEW FEATURES

Two-Wire Programmable Transmitter for:

Micro Thermo Standard Wiring Guide

MODEL: W2TS. Mini-MW Series

STT 3000 Smart Temperature Transmitter

H7625B, H7626B, H7635B,C H7636B, H7655B, H7656B

Dial-type digital bar graph. LEDs for Open Collector, Relays and Warning Indicator

W(G)S3.1 Position Sensor with Analog or A/D converted synchronous serial output

DIN SERIES DIGITAL PANEL METERS ELECTRO- NUMERICS, INC.

AMC mA Positioner

The Rosemount 848T Wireless Temperature Transmitter

Series T. General Eastern Differential Pressure Transmitters. GE Sensing. Description

The i-7531 CAN Repeater

Continental Hydraulics Installation Manual CEM-RA-A

TIY Programmable, Isolated Thermocouple Transmitter combines

Connecting a Neuron 5000 Processor to an External Transceiver

LB680A Pulse Profiling USB PowerSensor+ Data Sheet

Page 1 of Release 2.2. LON Transponder Reader. Technical Reports

Model 140 Inline Amplifier

CTE8000 Series OEM pressure transmitters for industrial media

Picture. Digital output signal (pressure and temperature) RS-485 Modbus RTU, 9600 bps Protocol details see Data Sheet SW

MODEL: 20VS2-02. Hybrid IC Isolation Amplifiers 20 Series

Transcription:

NEUROLOGIC RESEARCH CORPORATION MODEL 1400A DUAL 4-20 MA NETWORK BRIDGE Instantly integrate any standard sensor into the LONWORKS digital network. Supports loop and self powered sensors. Electronics are sealed for environmental durability. Digitally calibrated for high accuracy and custom inputs 1/2 NPT connection attaches directly to most sensors conduit entry. 3/4 NPT wiring conduit connection attaches to any standard wiring junction box. Multiple sensors multiplexed on same wires All outputs available using Standard Network Variables (SNVT) Compact and rugged body for durability Very compact package becomes part of the wiring conduit. Very high resolution of 0.05 ua. DC IN + Current Limit and Reverse Voltage Protection Current Input 2 (Blue) 100 1/2 NPT Current Input 1 (Green) DC IN Current Limit and Reverse Voltage Protection Ohm Sense Resistor 100 Ohm Sense Resistor Neuron CPU Voltage Regulator Analog to Digital Converter Transient Voltage Protection And Over-Current Fuse FTT-10 Network Xvr DC IN + NETWORK (2 Blue) 3/4 NPT DC IN Model 1400A Block NEUROLOGIC RESEARCH CORPORATION Copyright (c) 2003 Rev. 0

DESCRIPTION The Model 1400A is a dual input network bridge. It bridges industry standard analog transmitters with LONWORKS network devices. While the functionality of the Model 1400A is not new, its packaging allows it to essentially become part of the wiring conduit. One side simply fastens directly into most standard transmitters via their 1/2 NPT wiring entry. The other side of the Model 1400A is a 3/4 NPT that allows attachment of any standard electrical conduit box. This approach greatly reduces the amount of wiring and space required for interfacing sensors to a LonWorks network. Although it is very compact, the Model 1400A electronics include a central processing unit, precision sense resistors, a high-resolution analog to digital converter, and a network communication interface. The communication interface is the FTT-10 transceiver. This architecture allows multiple sensors to be used over a simple four-wire bus installation. Two wires are used for power, the other are used for digital communication. WIRING AND INSTALLATION There are four flying leads that extend out of the 3/4-inch NPT end of the Model 1400A. Also note the Service Switch and LED on this end. The Service Switch and LED are used for network installation. When pressed the unit transmits its internal Neuron ID onto the network. The four wires connect power and the LonWorks network to the Model 1400A as follows: WIRE COLOR Red Black Blue 2 Wires DESCRIPTION Positive DC Input Voltage of 10 to 32 volts Negative DC Input Voltage LonWorks FTT-10 network. Polarity insensitive. There are four additional flying leads that extend out of the 1/2-inch NPT end. These leads connect the Model 1400A s current inputs to external devices. Please note that the Red and Black wires on the 1/2- inch NPT end can be used to supply power to the unit if it is more convenient to do so on that side. Please see later sections and the block diagram above for clarity. The wire connections are as follows: WIRE COLOR Red Black Green Blue DESCRIPTION Positive DC Input Voltage of 10 to 32 volts Negative DC Input Voltage Current Input 1 ( Input by default) Current Input 2 ( Output by default) NEUROLOGIC RESEARCH CORPORATION Copyright (c) 2003 Rev. 0 Page 2

Current Inputs The current input supports loop and self powered devices. Loop powered devices require a two wire connection and are normally simple devices that can operate on a current between 4 and 20 ma. Selfpowered devices require a three-wire connection and normally require much higher currents to operate. The following diagrams demonstrate proper connection of loop and self powered devices to the Model 1400A s Input #1. Substitute the blue wire for the green in the following diagrams to connect to the second input. Note, that power can be connected to the Model 1400A from either side. Loop Powered Device + - Current Flow Input1 (Green) Model 1400A DC Power Supply + Self Powered Device - Current Flow Input1 (Green) Model 1400A DC Power Supply DC Current Input1, green wire, updates the nvoai[0] output network variable. Current Input 2, blue wire, updates nvoai[1] output network variable. By default, 4 ma on the input represents 0% while 20 ma represents 100%. Many sensors provide a local mean to adjust the 4 ma and 20 ma to some actual process values to re-range the transmitter s current output. If this approach is used, there are no further calibration or adjustment to be made. Additionally, the input can be digitally calibrated via commands sent across the network. Digital calibration is much more precise and does not suffer from long-term component drift. The Model 1400A s input calibration is very flexible allowing any current value in the range of 0 to 25 ma to be specified. Calibration of the Model 1400A includes zero and span to re-define the 0% and 100% points as well as an offset. For convenience, the Model 1400A allows the customer to also calibrate any two custom points. For example precision input sources may only be available at 23% and 68%. The net result is to simply define the lower and upper points on a straight line. This is then used to internally correlate the input signal to the output percentage value. The offset is used to move the straight line up and down without changing its slope. For maximum flexibility, there are no limits imposed on the upper or lower calibration points. This is useful since you can actually re-define the upper point to be less than the lower point and thus define a NEUROLOGIC RESEARCH CORPORATION Copyright (c) 2003 Rev. 0 Page 3

characteristic line with a negative slope. In this case, the percentage output, nvoai, will actually go down as the input current goes up. Enabling 50 Hz Filter By default, the Model 1400A hardware has high rejection of 60 Hz that may be induced on to the analog signals. If the units are installed in an environment where 50 Hz power lines are used the 50 Hz filter can be enabled by setting the nci50hzfilter Configuration Network Variable to ON. NEUROLOGIC RESEARCH CORPORATION Copyright (c) 2003 Rev. 0 Page 4

NETWORK OBJECTS The Model 1400A contains a Node Object and two identical LONMARK Analog Input Profiles, 0520, with input and output data shown below. The nvicalibrate and nvicalibval network variables allow the Model 1400A to be calibrated and re-ranged by the customer. Specific calibration functions for channel #1 are accomplished by writing the following values into nvicalibrate. The calibrate by value functions assume that nvicalibval contains a valid value before the command is written into nvicalibrate. Note, for the second channel add 16 to the command. 00 - Zero. The current input signal corresponds to 0%. 01 - Span. The current input signal corresponds to 100%. 02 - Calibrate Value #1. The current input signal corresponds to lower value which is contained in nvicalibval. 03 - Calibrate Value #2. The current input signal corresponds to upper value which is contained in nvicalibval. 15 - Reset calibration to factory Object 0: Node Object Type: 0 nv1 nvirequest SNVT_obj_request Mandatory Network Variables nv2 nvostatus SNVT_obj_status nv 50 nv 51 Manufacturer Defined Section nvicalibrate unsigned nvicalibval SNVT_lev_percent Configuration Properties ncixx - nci50hzfilter SNVT_lev_disc manufacturer Object 1&2: Analog Input Type: 0520 Mandatory Network Variables nv1 nvoai[2] SNVT_lev_percent Configuration Properties nci27 - ncimindelta SNVT_lev_percent manufacturer nci52 - nciminsendt SNVT_time_sec manufacturer nci49 - ncimaxsendt SNVT_time_sec manufacturer nci26 - nciaioffset[2] SNVT_lev_percent manufacturer NEUROLOGIC RESEARCH CORPORATION Copyright (c) 2003 Rev. 0 Page 5

GENERAL SPECIFICATION General CPU 3120 Neuron Network Transceiver FTT-10A Operating Temperature -40 85 C Operating Humidity 0-95% Relative Humidity non-condensing Environmental Protection Electronics are sealed. Input Power 10 to 32 VDC Input Power Protection Input power is fused and transient voltage protected. (Fuses do not need to be replaced) Current Consumption 20-30 ma Typical with service LED plus power used by devices. Plan for an additional 25 ma for each loop powered 4-20mA sensor. Network Transceiver Type Echelon FTT-10A transceiver at 78 kbps. DC blocking capacitors for LPT10 network. Sensor Wiring Non-terminated 24-awg wire leads 8 length. See Wiring and Installation Section for connection diagram and wire color. Input Power and Network Wiring Non-terminated 24-awg-wire leads 8 length. See Wiring and Installation Section for connection diagram and wire color. Analog Inputs Inputs 2 Input Types 0-25 ma current. Factory default is scaled for Input impedance 100 Ohm A/D resolution 0.05 ua. Note, limited by resolution of SNVT_lev_percent which is 0.005% Accuracy 5 ua at 25 C Software Update All inputs updated once every 300 milliseconds. Frequency Software Resolution 0.005% = SNVT_lev_percent network variable resolution Temp Coefficient 15 ppm per degree C Protection Reverse voltage and over-current limited to 32 ma typical Dimension and Materials Wiring Connection ¾ Male NPT Transmitter ½ Male NPT Probe Body 304 Stainless Steel 1.125 Hex, Installed length = 3.25 3.750" 1.300" 1/2" NPT 1 1/8" Hex 3/4" NPT NEUROLOGIC RESEARCH CORPORATION Copyright (c) 2003 Rev. 0 Page 6

ORDERING INFORMATION 1400A Model 1400A Dual Network Bridge Code Network Transceiver Option -0 TP/FTT-10A 1400A -0 Model 1400A with FTT-10A transceiver Echelon, LON, LONWORKS, Neuron, 3120, 3150, LONMARK are trademarks of Echelon Corporation. NEUROLOGIC RESEARCH CORPORATION Copyright (c) 2003 Rev. 0 Page 7