Standard Specifications

Similar documents
SECTION PRECAST CONCRETE SECTIONAL MANHOLES

SECTION MANHOLES

SECTION 39 - MANHOLES TABLE OF CONTENTS

MANHOLES PART I: GENERAL. A. Precast Concrete Manholes

SECTION PRECAST CONCRETE STRUCTURES

SECTION MANHOLES

SECTION PUBLIC UTILITY MANHOLES AND STRUCTURES. 2. Modular precast concrete pump wetwell. 5. Manhole bedding and cover materials.

SECTION 58 PRECAST CONCRETE BOX CULVERT. This work consists of furnishing and installing Pre-cast Concrete Box Culverts.

The Manitoba Water Services Board SECTION Standard Construction Specifications September 2013 Page 1 of 8

SPECIFICATIONS FOR THE MANUFACTURE AND DESIGN OF PRECAST THREE SIDED ARCH STRUCTURES, WINGWALLS AND HEADWALLS

A. Extent of structural precast concrete work is shown on drawings and in schedules.

KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, 1990 EDITION

STRUCTURES FOR SANITARY AND STORM SEWERS

STANDARD SPECIFICATIONS SECTION PRECAST CONCRETE 1.2 REQUIREMENTS FOR MANUFACTURERS AND SUPPLIERS BEFORE DELIVERY

UNDERGROUND UTILITY TRENCHES AND VAULTS Page 1 of 6 ADDENDUM #1

CONSTRUCTION SPECIFICATION FOR MAINTENANCE HOLE, CATCH BASIN, DITCH INLET, AND VALVE CHAMBER INSTALLATION

REQUEST FOR BIDS WELL #4 ABANDONMENT

Pipe Product Catalog Table of Contents

SECTION 8: DRAINAGE, SEWER AND WATER SUPPLY NETWORKS

StormTrap Guide Specification. StormTrap SingleTrap on Pad Foundation Groundwater BELOW Invert Revised 11/21/18

Large Scale CalArc Pavers for Sand-Set Pedestrian Use Installations

SECTION STEEL LIGHTING STANDARDS. 1. Electrical conduit and fittings; Section

StormTrap Guide Specification. StormTrap 2 SingleTrap on Aggregate Foundation Groundwater BELOW Invert Revised 11/30/17

IGGA Guide Specification: Dowel Bar Retrofit (DBR) Introduction

WAL-MART SUPERCENTER # ; Milwaukie, OR: SPECIFICATIONS. Revisions to Specification Fence

2016 Specification Treads, Base, Stringers and other Amenities Wausau Tile Precast Epoxy Terrazzo

CONSTRUCTION SPECIFICATION FOR PRECAST REINFORCED CONCRETE BOX CULVERTS AND BOX SEWERS

D. Thermally Sprayed Metallic Coating (Flame Spray): STD SPEC

1. Architectural precast concrete cladding units.

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENT 1073 PRECAST CONCRETE CERTIFICATION PROGRAM JULY 20, 2018

SECTION PRECAST CULVERT STEAM TUNNEL

SECTION ARCHITECTURAL PRECAST CONCRETE PART 1 - GENERAL

Proposal PROJECT MANUAL P R O P E R T Y M A N A G E M E N T F A L L O N C O U N T Y. Baker, MT P.O. Box 846

NITTERHOUSE CONCRETE PRODUCTS, INC Molly Pitcher Highway South Chambersburg, PA

SECTION PRECAST HOLLOW CORE PLANKS

Section 914. JOINT AND WATERPROOFING MATERIALS

4.1. Foremen 4.2. Concrete plant manager 4.3. Concrete plant operator 4.4. Personnel performing saw cutting and joint sealing

SECTION G ESTIMATE OF QUANTITIES

1. INTRODUCTION 2. REFERENCE SPECIFICATIONS. Page -1- Bonding and Grouting

STANDARD CATCH BASIN GUTTER LINE CB INLET FRAME & GRATE, GROUTED TO GRADE RINGS AS REQ'D CONCRETE CURB FINISHED GRADE ASPHALT MAX 50 MIN

3400 Tectura Designs Precast Concrete

BPDL Architectural precast concrete specifications USA TESTING AND INSPECTION A. Testing by Independent Agency : Materials and workmanship furn

SECTION STRUCTURAL STEEL FRAMING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

14 March 2016 City Hall Station Renovations Bid Documents 15 th Street Station Phase Station Improvements SECTION PRECAST CONCRETE

B. Installation Instructions. Provide installation instructions, including any special equipment, to address the following.

SECTION 1085 PRECAST REINFORCED CONCRETE BOX CULVERT

1.1 SUMMARY. A. This Section includes the following: 1. Loose steel lintels. 2. Shelf angles. 3. Metal floor plate. 4. Pipe bollards.

SECTION METAL FABRICATIONS

MH Table of Contents Standard Title/Scope Page Table of Contents SCE Public

SECTION TRACER WIRE FOR NONMETALLIC PIPE

PART MATERIALS. Section Fencing Materials. Description

MEDIUM DUTY CAST IRON SLIDE GATES SERIES 20-10C

CS3 represents manufacturers of products for use in the municipal waterworks industry.

SECTION CONCRETE REINFORCEMENT FOR STEAM UTILITY DISTRIBUTION

CVO/169897A OCTOBER 29, GROUT

CUTTING THE PIPE: BLUE DUCT Pipe can be easily cut using a Circular Saw or Reciprocal Saw. Trim all edges as necessary.

SECTION UNDERGROUND POWER DUCT AND SUB-STRUCTURES. A. Section : Trenching, Backfilling, and Compacting

"A" "A" SECTION "A-A" X-SECTION VERTICAL CURB (TYPE B) Village STREET & PAVEMENT STR-05. Engineering Department

Manholes Table of Contents

STORM M ANHOLE FOR 42" PIPE AND SM ALLER JOB NO. SHEET NO. DATE MARCH 2015 OF MIN OF 3 CRSES MAX OF 5 CRSES 30"MAX 3 OR 3.5 PRECAST ECCENTIC CONC

EMMEGI ARCHITECTURAL FENCING MASTER SPECIFICATION SECTION METAL FENCING, GATES & RAILING SYSTEM PART 1 GENERAL

b. B aluminum and aluminum-alloy extruded bar, rod, wire, shape and tube

1. ANSI/ASME Standard B , Square and Hex Bolts and Screws, Inch Series

SECTION CHAIN LINK FENCING AND GATES AND SOFTBALL BACKSTOP

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

SECTION SHEET METAL FLASHING AND TRIM

FACTS YOU NEED TO KNOW ABOUT WATERTIGHT PRECAST MANHOLES

SECTION SAND CUSHION TERRAZZO FLOORING

PRESTON HEALTH SERVICES ARCHITECT S NO. 2700

Project No.: VTRC 06-R22 March Period Covered: Contract No.

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

SECTION COUNTERTOPS ecox PART 1 GENERAL

SECTION BULLET- RESISTANT DOORS

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

SAUSALITO-MARIN CITY SANITARY DISTRICT MISCELLANEOUS UPGRADES PROJECT. Addendum No. 2

SECTION STRUCTURAL STEEL. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

DISTRIBUTION VAULT 8' x 14' x 9'-4" DEEP TRAFFIC FLAT WALL WITH 5' x 8' OPENING

MATERIAL COMBINATION NUMBER 2: Corrosive environment requiring harder, wear-resistant seating faces and resistance to dezincification.

SECTION CHAIN LINK FENCING AND GATES

4. Metal roof jacks at penetrations and attachments

Section COUPLINGS AND COUPLING ADAPTERS. This Section covers couplings and coupling adapters for ductile iron and steel pipe.

Essex County College - West Essex Campus Addition And Renovations dlb # / SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING

TENANT IMPROVEMENT 16 FEBRUARY WEST 27TH STREET, 4TH FLOOR 100% CD OWNER/BID ADD 1-03/08/2018

Testing. Material testing will be according to applicable AASHTO, ASTM or Department methods as specified.

VILLAGE OF VILLA PARK CENTRAL BOULEVARD IMPROVEMENTS LOCATION MAP (NOT TO SCALE) CORTESI AVE. MYRTLE AVE. CENTRAL BLVD.

11-1/4 OD at Transition Point. Microcosmic. 4th and Brannan Street Platform Station Project. Elevation. Moto Ohtake 2014

SECTION TRAFFIC SIGNAGE

ABOUT INLAND. Tannis Karklin, E.I.T Technical Sales and Marketing

Utility Structures. Utility vaults, trenches, transformer pads Electrical Pole Bases and switching cubicles

Anti-Trust Statement

Design and Construction Standards SECTION ATHLETIC LOCKERS

A. Radius elbows with a construction radius of 1.5 the duct width are preferred to square elbows.

2. All work and materials shall be in full accordance with Local and State ordinance and with any prevailing rules and regulations.

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

CONCRETE MANHOLES.

A. Compatibility: Products shall be suitable for piping service fluids, materials, working pressures, and temperatures.

A. Deviation from this standard must be approved by the Project Architect.

B. Terracotta Precast Facade Assembly consisting of single-leaf, through body color terracotta clay tiles.

TOWN of LAKESHORE SITE PLAN CHECKLIST

CITY OF PITTSBURG ENGINEERING DEPARTMENT CONTRACT NO A WATER TREATEMENT PLANT CAPITAL IMPROVEMENTS PHASE 1A ADDENDUM #1 FENCE AND DITCH AUGUST

Transcription:

Standard Specifications

PART 1.00 GENERAL 1.01 DECRIPTION SECTION 02620 PRECAST REINFORCED CONCRETE SANITARY MANHOLES A. Work included: The Contractor shall furnish all labor, materials, equipment, and incidentals required and install all precast concrete units including tops in accordance with the Drawings and these Specifications. 1.02 RELATED WORK A. Unit Masonry B. Miscellaneous Materials C. Water Tight Joints 1.03 REFERENCES A. American Society for Testing and Materials (ASTM): 1. ASTM A-185 Steel Welded Wire Fabric for Concrete Reinforcement 2. ASTM C33 Concrete Aggregates 3. ASTM C39 Compressive Strength Cylinder Specimens 4. ASTM C478 Precast Reinforced Concrete Manhole Sections 5. ASTM C497 Testing of Manhole Sections 6. ASTM C990 Joints for Concrete Pipe, Manholes, and Precast Box Sections Using Preformed Flexible Joint Sealants 7. ASTM C1244 Standard Test Method for Concrete Sewer Manholes by the Negative Air Pressure (Vacuum) Test B. American Association of State Highway and Transportation Officials (AASHTO): 1. AASHTO M55- Steel Welded Wire Fabric for Concrete Reinforcement 2. AASHTO M199 Precast Reinforced Concrete Manhole Sections 3. AASHTO M198 Joints for Concrete Pipe, Manholes and Precast Box Sections Using Preformed Flexible Joint Sealants 4. AASHTO T22 Compressive Strength Cylinder Specimens 5. AASHTO T280 Testing of Manhole Sections C. Occupational Safety and Health Standards (OSHA): 1. OSHA 29 CFR 1910.27 Steps and Ladders D. State of Connecticut Department of Transportation (CTDOT): 1. Form 815 and Supplements 1.04 SUBMITTALS A. Shop Drawings: Submit shop drawings under provisions of Section 01340. Show pertinent dimensions, steel, and concrete strength B. Quality Control Submittals: Submit manufacturers certification indicating compliance with specified performance and design requirements. SECTION 02620 Page 1

C. Test Reports: Submit test reports for concrete strength under provisions of Section 01410. 1.05 DELIVERY, STORAGE, AND HANDLING A. Comply with provisions of Section 01610. B. Delivery of new product. C. Store units in an upright position. PART 2.00 PRODUCTS 2.01 MANUFACTURERS A. Precast Manholes: Connecticut Precast Corporation, Monroe, CT (203) 268-8688 or equivalent. B. Manholes Frames and Covers: Campbell Foundry, North Haven, CT or equivalent. 2.02 MATERIALS A. Manhole Bases: Bases shall have a monolithic base slab with riser barrel conforming to ASTM C478, AASHTO M199, and designed for AASHTO H20 loading. B. Manhole Risers: Riser sections shall have a minimum 5 wall for 48 diameter, 6 wall for 60 diameter, 7 wall for 72 diameter, 8 wall for 84 diameter, 9 wall for 96 diameter, 11 wall for 120 diameter, and 12 wall for 144 diameter and conform to ASTM C478 and AASHTO M199. C. Manhole Top Slabs: Top Slabs shall have a minimum thickness of 8 and conform to ASTM C478 and designed for AASHTO H20 loading. D. Manhole Steps: Manhole steps shall be ½ diameter steel reinforced copolymer polypropylene conforming to ASTM C478, AASHTO M-199 and OSHA 29 CFR 1910.27. Steps shall be placed in vertical alignment in preformed holes as per step manufactures instructions. The steps shall resist a pullout force of over 1500 lbs. Eng lugs shall have a reflecting material insert. E. Concrete: Concrete shall air entrained in accordance with CTDOT specifications and have a minimum concrete compressive strength of 4,000 PSI at 28 days. Concrete shall be placed in forms and vibrated in such a manner to make a dense uniform product. Concrete shall have a minimum density of 150 PSI and absorption of 5%-8%. F. Coating: Exterior surfaces of manholes shall have two coats of an approved asphalt coating applied according to manufactures recommendations. An alternate to the exterior coating shall be a concrete admixture that is applied to the concrete with batching and demonstrates a reduction in water absorption below five percent. G. Pipe Connections: Pipes shall be connected to the manhole walls using an approved flexible sleeve. Approved connections shall be Press-Seal Corporation, Kor-N-Seal by NPC, Inc., A-Lok or Z-Lok by A-Lok Products, or approved equal conforming to ASTM C990. H. The Engineer prior to use shall approve Extension/adapter rings. I. Joint Sealant: Joint sealant shall be an approved butyl rubber conforming to ASTM C478 and ASTM C990. SECTION 02620 Page 2

PART 3.00 EXECUTION 2.01 INSTALLATION A. The manholes shall be constructed according to the sizes shown on the Drawings and as specified herein. Install at elevations and locations on the Drawings or as otherwise directed by the Engineer. B. Place the Precast base units on a granular sub base with a minimum thickness of six inches after compaction or of greater thickness and compaction if specified elsewhere. The granular sub base shall be check for level prior to setting. C. Pipe openings shall be sealed by the Contractor with cement mortar and shall be sized to accept pipes of the specified size(s) and material(s). D. After setting of precast base section, the joint shall be clean free of dirt or other unsuitable materials. A butyl joint sealant conforming to ASTM C990 shall be applied to the joint area and then the next precast section installed. Set all sections in plum. When setting sections ensure that the manhole steps are set in vertical alignment. After two sections are joined together. The interior and exterior of the joints shall be grouted. E. Joining Pipe to Manholes 1. If manhole base sections are equipped with flexible sleeves, slide pipe through sleeve until the end of the pipe is flush with the inside wall of manhole. Install and secure sleeve to pipe with stainless steel clamp is required. If flexible sleeve is a compression type, such as A-Lok type, no external stainless steel clamp is required. 2. If the joint is a grouted joint, place pipe through hole in manhole base section until end of pipe is flush with inside wall of manhole. Place a water stop device on the pipe. Mix and place concrete all around pipe, to full manhole wall thickness. Make a watertight joint. F. Plug holes, in the concrete sections made for handling with a non-shrink grout and/or the rubber plugs. G. Install tops according the Drawings at finished grade. Adjust to grade with brick or masonry conforming to ASTM C32 or pre-approved precast grade rings. 2.02 FIELD TESTING A. General: Provide all equipment and personnel necessary, and make all tests required to demonstrate that the work of this section has been completed in strict accordance with the design and the specified requirements. B. Inspection: All units shall be inspected to be sound. There shall be no visible leakage through the walls or pipe connections. C. Testing: Testing on Sanitary Precast Concrete Manholes shall be by Vacuum Testing in accordance with ASTM C1244. All vacuum testing shall be preformed prior to backfilling of manhole. The test procedure shall be as follows: 1. Plug, seal, and brace all pipes entering the manhole to prevent them from dislodging during the test. Pipe plugs shall be installed beyond boot seals. 2. Firmly secure vacuum testing equipment to manhole as per recommendations. 3. Start vacuum and seal and necessary leaks around the testing equipment bladder. 4. Attain a vacuum of 10 Hg. 5. Time pressure drop to 9 Hg. Record time. If time to drop 1 Hg is less than 1 minute, manhole shall be passed. If manhole does not pass, the Contractor shall locate leak(s) and repair and retest until satisfactory. SECTION 02620 Page 3

6. Release Vacuum and backfill manhole in accordance with specifications herein. D. Repair: Any defect found shall be repaired as approved by the Engineer. The repair method shall be of sound principle to ensure compliance with this specification. END OF SECTION SECTION 02620 Page 4

SECTION 02722 PRECAST REINFORCED CONCRETE STORM MANHOLES AND CATCH BASINS PART 1.00 GENERAL 1.01 DECRIPTION A. Work included: The Contractor shall furnish all labor, materials, equipment, and incidentals required and install all precast concrete units including tops in accordance with the Drawings and these Specifications. 1.02 RELATED WORK A. Unit Masonry B. Miscellaneous Materials C. Water Tight Joints 1.03 REFERENCES A. American Society for Testing and Materials (ASTM): 1. ASTM A-185 Steel Welded Wire Fabric for Concrete Reinforcement 2. ASTM C33 Concrete Aggregates 3. ASTM C39 Compressive Strength Cylinder Specimens 4. ASTM C478 Precast Reinforced Concrete Manhole Sections 5. ASTM C497 Testing of Manhole Sections 6. ASTM C990 Joints for Concrete Pipe, Manholes, and Precast Box Sections Using Preformed Flexible Joint Sealants B. American Association of State Highway and Transportation Officials (AASHTO): 1. AASHTO M55- Steel Welded Wire Fabric for Concrete Reinforcement 2. AASHTO M199 Precast Reinforced Concrete Manhole Sections 3. AASHTO M198 Joints for Concrete Pipe, Manholes and Precast Box Sections Using Preformed Flexible Joint Sealants 4. AASHTO T22 Compressive Strength Cylinder Specimens 5. AASHTO T280 Testing of Manhole Sections C. Occupational Safety and Health Standards (OSHA): 1. OSHA 29 CFR 1910.27 Steps and Ladders D. State of Connecticut Department of Transportation (CTDOT): 1. Form 815 and Supplements 1.04 SUBMITTALS A. Shop Drawings: Submit shop drawings under provisions of Section 01340. Show pertinent dimensions, steel, and concrete strength B. Quality Control Submittals: Submit manufacturers certification indicating compliance with specified performance and design requirements. SECTION 02722 Page 1

C. Test Reports: Submit test reports for concrete strength under provisions of Section 01410. 1.05 DELIVERY, STORAGE, AND HANDLING A. Comply with provisions of Section 01610. B. Delivery of new product. C. Store units in an upright position. PART 2.00 PRODUCTS 2.01 MANUFACTURERS A. Precast Manholes: Connecticut Precast Corporation, Monroe, CT (203) 268-8688 or equivalent. B. Manholes Frames and Covers: Campbell Foundry, North Haven, CT or equivalent. C. Catch Basins: Connecticut Precast Corporation, Monroe, CT (203) 268-8688 or equivalent. 2.02 MATERIALS A. Manhole Bases: Bases shall have a monolithic base slab with riser barrel conforming to ASTM C478, AASHTO M199, and designed for AASHTO H20 loading. B. Manhole Risers: Riser sections shall have a minimum 5 wall for 48 diameter, 6 wall for 60 diameter, 7 wall for 72 diameter, 8 wall for 84 diameter, 9 wall for 96 diameter, 11 wall for 120 diameter, and 12 wall for 144 diameter and conform to ASTM C478 and AASHTO M199. C. Manhole Top Slabs: Top Slabs shall have a minimum thickness of 8 and conform to ASTM C478 and designed for AASHTO H20 loading. D. Manhole Steps: Manhole steps shall be ½ diameter steel reinforced copolymer polypropylene conforming to ASTM C478, AASHTO M-199 and OSHA 29 CFR 1910.27. Steps shall be placed in vertical alignment in preformed holes as per step manufactures instructions. The steps shall resist a pullout force of over 1500 lbs. Eng lugs shall have a reflecting material insert. E. Concrete: Concrete shall air entrained in accordance with CTDOT specifications and have a minimum concrete compressive strength of 4,000 PSI at 28 days. Concrete shall be placed in forms and vibrated in such a manner to make a dense uniform product. F. Catch Basins: Catch Basin shall be of size as indicated on Drawings. Standard Catch Basin shall be as shown on CTDOT Specification Drawings 507H. The minimum wall thickness shall be six inches with a shiplap joint. All knockouts in riser walls shall be steel reinforced. G. Catch Basin Tops: Catch Basin Tops shall be as indicated on Drawings. Concrete Tops shall be manufactured in accordance with CTDOT Form 815 Specifications and as manufactured by Connecticut Precast Corp. All Catch Basin Frames and Grates shall be galvanized steel or cast iron in accordance with the applicable requirements of Section M.06.03 of Form 815. H. The Engineer prior to use shall approve Extension/adapter rings. SECTION 02722 Page 2

PART 3.00 EXECUTION 2.01 INSTALLATION A. The manholes and catch basins shall be constructed according to the sizes shown on the Drawings and as specified herein. Install at elevations and locations on the Drawings or as otherwise directed by the Engineer. B. Place the Precast base units on a granular sub base with a minimum thickness of six inches after compaction or of greater thickness and compaction if specified elsewhere. The granular sub base shall be check for level prior to setting. C. Pipe openings shall be sealed by the Contractor with cement mortar and shall be sized to accept pipes of the specified size(s) and material(s). D. After setting of precast base section, the joint shall be clean free of dirt or other unsuitable materials. A butyl joint sealant conforming to ASTM C990 shall be applied to the joint area and then the next precast section installed. Set all sections in plum. When setting sections ensure that the manhole steps are set in vertical alignment. E. Plug holes, in the concrete sections made for handling with a non-shrink grout and/or the rubber plugs. F. Install tops according the Drawings at finished grade. Adjust to grade with brick or masonry conforming to ASTM C32 or pre-approved precast grade rings. 2.02 FIELD TESTING A. General: Provide all equipment and personnel necessary, and make all tests required to demonstrate that the work of this section has been completed in strict accordance with the design and the specified requirements. B. Inspection: All units shall be inspected to be sound. There shall be no visible leakage through the walls or pipe connections. C. Repair: Any defect found shall be repaired as approved by the Engineer. The repair method shall be of sound principle to ensure compliance with this specification. END OF SECTION SECTION 02722 Page 3