Study of the immunity of the GSM-R against electromagnetic disturbances present on moving trains

Similar documents
Statistical characterisation of the EM interferences acting on GSM-R antennas fixed above moving trains

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

Standardisation and Immunity Tests regarding IEMI

On the characterization of pantograph arc transients on GSM-R antenna. Andrea Mariscotti 1, Virginie Deniau 2

Evaluation of the Impact of Transient Disturbances on Railway Signaling Systems Using an Adapted Time-Frequency Analysis Method

PANTOGRAPH ARC TRANSIENTS OCCURRENCE AND GSM-R CHARACTERISTICS

Human volunteer studies: general and special populations. Human Exposure to Base Station Signals Source Specification

Spectrum Analyzers R3132/3132N/3162 R3132/3132N/3162. Low cost, high performance. General-Purpose Spectrum Analyzer Adaptable to Various Applications

Co-Existence of UMTS900 and GSM-R Systems

Interference Direction Analysis. Communication Signals

ELEC 0017: ELECTROMAGNETIC COMPATIBILITY LABORATORY SESSIONS

SPREAD SPECTRUM CHANNEL MEASUREMENT INSTRUMENT

Wireless Physical Layer Concepts: Part III

Level 6 Graduate Diploma in Engineering Wireless and mobile communications

ETSI Standards and the Measurement of RF Conducted Output Power of Wi-Fi ac Signals

Unit 4 - Cellular System Design, Capacity, Handoff, and Outage

Successful mobile-radio tester now with US TDMA and AMPS standards

Annex - Propagation environment: real field example Analysis with a high resolution Direction Finder

GSM Transmitter Modulation Quality Measurement Option

Access Methods and Spectral Efficiency

Selected answers * Problem set 6

Outline for this presentation. Introduction I -- background. Introduction I Background

Wireless WANS and MANS. Chapter 3

EMI Pre-Compliance Testing Solution

Contents. ZT530PCI & PXI Specifications. Arbitrary Waveform Generator. 16-bit, 400 MS/s, 2 Ch

Evaluating Electromagnetic Railway Environment Using adaptive Time-Frequency Analysis

INSTRUCTION SHEET WIDEBAND POWER SENSOR MODEL Copyright 2008 by Bird Electronic Corporation Instruction Book P/N Rev.

FFT 3010 EMI TEST RECEIVER

SC5307A/SC5308A 100 khz to 6 GHz RF Downconverter. Datasheet SignalCore, Inc.

SC5407A/SC5408A 100 khz to 6 GHz RF Upconverter. Datasheet. Rev SignalCore, Inc.

Wireless Networks: An Introduction

Performance Analysis of GSM System Using SUI Channel

Reti di Telecomunicazione. Channels and Multiplexing

ECE 476/ECE 501C/CS Wireless Communication Systems Winter Lecture 9: Multiple Access, GSM, and IS-95

Input to FM54 on OOB emissions due to UMTS or LTE signals

Radar-Verfahren und -Signalverarbeitung

R3477. Ideal for mobile communication applications including base stations and handsets, from the development stage to production and installation

RF Channel Characterization with Multiple Antenna Systems for LTE

UNIVERSITI MALAYSIA PERLIS Pusat Pengajian Kejuruteraan Komputer dan Perhubungan Semester 1, 2011/12 DKT 211 Basic Communication Engineering

2620 Modular Measurement and Control System

Harvesting a Clock from a GSM Signal for the Wake-Up of a Wireless Sensor Network

RECOMMENDATION ITU-R SM.1268*

Spectrum Analyzers 2680 Series Features & benefits

Multipath fading effects on short range indoor RF links. White paper

IEEE SUPPLEMENT TO IEEE STANDARD FOR INFORMATION TECHNOLOGY

NXDN Signal and Interference Contour Requirements An Empirical Study

RECOMMENDATION ITU-R M.1580 *, ** Generic unwanted emission characteristics of base stations using the terrestrial radio interfaces of IMT-2000

ADJACENT BAND COMPATIBILITY BETWEEN TETRA TAPS MOBILE SERVICES AT 870 MHz

CEPT/ERC Recommendation ERC E (Funchal 1998)

Preliminary RFI Survey for IIP

Spectrum Analyser Monitoring of Wireless Communications Networks. Claudio Narduzzi, Paolo Attilio Pegoraro, Luigi Prigol

Digital Modulation Schemes

RECOMMENDATION ITU-R BS

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 AMETEK CO., LTD. NAGOYA OFFICE. (Main Laboratory) Onna, Atsugi-shi, Kanagawa-ken, Japan

Signal generators. Modular design for user-friendly solutions

INTRODUCTION OF RADIO MICROPHONE APPLICATIONS IN THE FREQUENCY RANGE MHz

CORRELATION FOR MULTI-FREQUENCY PROPAGA- TION IN URBAN ENVIRONMENTS. 3 Place du Levant, Louvain-la-Neuve 1348, Belgium

Chapter 7 GSM: Pan-European Digital Cellular System. Prof. Jang-Ping Sheu

ER55 EMI TEST RECEIVER Family of automatic test receivers for measurement of electromagnetic interference from 9kHz to 2.8GHz.

Page 1. Problems with 1G Systems. Wireless Wide Area Networks (WWANs) EEC173B/ECS152C, Spring Cellular Wireless Network

Test of rolling stock electromagnetic compatibility for cross-domain interoperability

Some Aspects Regarding the Measurement of the Adjacent Channel Interference for Frequency Hopping Radio Systems

EMI Test Receivers: Past, Present and Future

Agilent AN 1275 Automatic Frequency Settling Time Measurement Speeds Time-to-Market for RF Designs

CS6956: Wireless and Mobile Networks Lecture Notes: 3/23/2015

PXI LTE FDD and LTE TDD Measurement Suites Data Sheet

2026Q CDMA/GSM Interferer MultiSource Generator

Chapter 14. Cellular Wireless Networks

Pulsed S-Parameter Measurements using the ZVA network Analyzer

PROPAGATION CHANNEL EMULATOR : ECP

EMC in the railway environment Hans Bängtsson

DMR Rx Test Solution. Signal Analyzer MS2830A. Reference Specifications

The need for Tower Mounted Amplifiers

Introduction: The FFT emission measurement method

RKE/TPS Measurement System Measurement for Automotive Applications

CONFORMANCE TEST REPORT FOR EN /-6

Part 3. Multiple Access Methods. p. 1 ELEC6040 Mobile Radio Communications, Dept. of E.E.E., HKU

SC5306B 1 MHz to 3.9 GHz RF Downconverter Core Module. Datasheet SignalCore, Inc.

ERC Recommendation 54-01

Models 296 and 295 combine sophisticated

Spectrum Sensing as a tool to analyze Wideband HF channel availability

Study on the next generation ITS radio communication in Japan

Technical Details and Guidelines for VDES Implementation

Objectives. Presentation Outline. Digital Modulation Revision

Ultra Wideband Transceiver Design

ECS455: Chapter 4 Multiple Access

Single Frequency Network Structural Aspects & Practical Field Considerations

Signal Sources. 2026A/B 10 khz to 2.05/2.51 GHz MultiSource Generator.

2026A/B 10 khz to 2.05/2.51 GHz MultiSource Generator

AN4949 Application note

For the National Voluntary Laboratory Accreditation Program

Page 1. Overview : Wireless Networks Lecture 9: OFDM, WiMAX, LTE

Introduction to GSM. Introduction to GSM, page Development of GSM. History of GSM. Market situation. GSM s future development

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Personal Communication System

TAS5600. Advanced Test Equipment Rentals ATEC (2832) Universal Interference Emulator

Ultra Wide Band Communications

The Cellular Concept. History of Communication. Frequency Planning. Coverage & Capacity

Dive deep into interference analysis

Telecommunication Electronics

Transcription:

Study of the immunity of the against electromagnetic disturbances present on moving trains Virginie Deniau, INRETS, France virginie.deniau@inrets.fr R. Adriano, S. Dudoyer, N. Ben Slimen, J. Rioult, P. Massy, B. Meyniel, M. Berbineau, A. Raux and E. Smulders

Outline The system Characterisation and Analysis of the disturbances received by antennas Impact of the supply voltage on the disturbances Estimation of the impact of the transient disturbances on the BER of communications Immunity testing on communications in laboratory Detection of transients disturbances for diagnostic in-situ Conclusion, future works Railcom final conference, UIC, Paris, 21 april 2009

ERTMS and ERTMS: European Rail Traffic Management System Harmonised signaling standards throughout Europe : Global System for Mobiles-RAILWAYS radio system for providing voice and data communication between the track and the train Data and voice transmissions

PCRD 6 STREP The is based on the standard GSM Phase 2+ the modulation type is GMSK (Gaussian Minimum Shift Keying). Specific frequencies: 876-880 MHz for the up-link (trains base stations) 921-925 MHz for the down-link (base stations trains) 200 khz frequency spacing between each channel + Advanced functions specifically developed for rail. group calls, ads or calls broadcast, location-based connections, call pre-emption in case of emergency Base Transceiver Station (BTS) close to the tracks The distance between base stations 3-4 km antennas on the roof of the trains

PCRD 6 STREP The is a Time Division Multiple Access (TDMA) system For each carrier frequency (physical channel) - data are organized per periodic TDMA frame, with a period of 4.615 ms. - each TDMA frame is divided into 8 time intervals of 577 μs long called "Time Slots" Each Time Slot (logical channel) - includes 156 bits which 148 bits of information. The one bit transmission duration is about 3.7 µs.

PCRD 6 STREP Carrier frequencies physical channels Frequency 924.8 MHz 924.6 MHz 921.4 MHz 921.2 MHz user 1 TDMA frame= 4.6 ms user 2 user 3 user 4 user 5 user 6 user 7 8 logical channels 200 khz user 8 user 1 burst user 2 Time slot 577 μs user 3 3.7 µs bit time user 4 user 5 user 6 user 7 user 8 Time

Characterisation and Analysis of the disturbances received by antennas

The disturbances received by antennas Main potential EM disturbances for the : Public GSM, UMTS 900 on frequency channels adjacent to the frequency bands «permanent» disturbances Transients coming from the catenary - pantograph sliding contact On-board measurements: 1. To characterise the coverage levels of the permanent disturbances 2. To characterise the level of noise produced by the transients in the frequency bands 3. To characterise the time characteristics and the repetition rate of the transients

Analysis of transient disturbances received by antennas Characterisation of the noise levels produced by the transients in the frequency bands: F.F.T Power (dbm) Power (dbm) 300 MHz 1 GHz S11-antenna -35 dbm frequencies are systematically covered -35 dbm

Time caracteristics of the transient disturbances Characterisation of the time characteristics of the transients : A A 100% 90% 50% Duration time 10% Rise time time

Time caracteristics of the transient disturbances Statistical study with about 20000 collected transients on trains: Probability Density Function 15 10 5 0 x 10 7 Duration experimental distribution empirical distribution 0 0.5 1 1.5 2 Duration (s) x 10-8 Probability Density Function 2.5 2 1.5 3 x 109 1 20 ns 0.5 1 ns 0 Rise Time experimental distribution empirical distribution 2 4 6 8 10 Rise time (s) x 10-10 Duration (s) Typical duration = 5 ns Rise time (s) Typical rise time = 0.4 ns

Analysis of transient disturbances received by antennas Characterisation of the repetition rate «Rr» of the transients : Measurements performed in 400 µs time windows Objective: to establish distributions of the time delays between the transients according to the operating conditions 0.6 Amplitude (V) 0.4 0.2 0 Time delay Amplitude (V) -0.2 400 µs -0.4 0 1 2 3 4 Time (s) x 10-4 1 0.5 0-0.5 1 transient/ 10 µs 400 µs -1 0 1 2 3 4 0.15 0.1 0.05 0-0.05-0 1 1 transient/ 5µs 400 µs Very variable Rr according to the trains operating conditions

Number of transient disturbances Analysis of transient disturbances received by antennas Number of transients in each 400 µs time window : 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 0 0 200 400 600 800 1000 1200 1400 1600 0 200 400 600 file 800 order 1000 1200 1400 1600 Successive time windows 1568 recorded files Time duration of the measurements process 400 µs Time Window + Loading Time = ~ 1 s 4.5 µs medium time delay between two successive transients Over a 1500 s Measurements duration :1568 recorded files ==> 0,95 s Measurement equipment was continuously detecting transients

Impact of the supply voltages on the time characteristics of the transients About 300 transient disturbances collected under 1500 Vcc and 25000 Vac Comparison of the rise times Time (ns) 2 x 10-9 1500 Vcc 1.5 1 0.5 0 0 50 100 150 200 250 300 2 x 10-9 Rise Time = 0.4 ns Typical rise time 25000 Vcc 1.5 1 0.5 = 0.4 ns 0 0 50 100 150 200 250 300

Impact of the supply voltages on the noise levels over the channels About 300 transient disturbances collected under 1500 Vcc and 25000 Vac FFT of the 300 transients and post pocess to extract the maximal noise level over the frequency bands -40 1500 Vcc -50-60 -70-80 0 50 100 150 200 250 300-40 Maximal Amplitude 921 MHz - 925 MHz -50 25000 Vcc -60-70 -80 0 50 100 150 200 250 300 921 MHz-925 MHz : Down-link

Impact of the supply voltages on the peak values About 300 transient disturbances collected under 1500 Vcc and 25000 Vac Peak value F.F.T Power (dbm) 921 MHz-925 MHz 2-40 1500 Vcc 1.5 1-50 -60 0.5-70 0 0 50 100 150 200 250 300-80 0 50 100 150 200 250 300 2 Peak Amplitude -40 Maximal Amplitude 921 MHz - 925 MHz 1.5-50 25000 Vcc 1 0.5-60 -70 0 0 50 100 150 200 250 300-80 0 50 100 150 200 250 300

Estimation of the impact of the transient disturbances on the BER of communications

Transient disturbances and BER on transmissions Hypothesis : GSM burst Transients duration << duration of one bit approximated by a punctual event, Transients produce high levels of interference in the band, Transients produce an arbitrary decision in a bit inside the burst (worst case?). BER = 2 1 R R r S Rs is the symbol rate of the communication system Rr represents the repetition rate of the transients Railcom final conference, UIC, Paris, 21 april 2009

Immunity testing on communications in laboratory

Immunity testing on communications Test set-up : CMU 200 924.8 MHz BER = Erroneous bits * 100% total number of bits Over 1200 speech frames Mobile Loop back combiner -40dB Combiner 50 Ω load CMU 200 SMIQ Spectrum analyzer Calibration of the power levels SMIQ GSM Public 925.2 MHz Signal generator Directional combiner Amplifier

combiners Mobile CMU 200 Spectrum analyzer Arbitrary signal generator SMIQ Oscilloscope Railcom final conference, UIC, Paris, 21 april 2009

Immunity testing on communications Power calibration based on the preliminary on-board measurements: Mobile CMU 200 924.8 MHz? SMIQ GSM Public 925.2 MHz? Combiner load? Signal generator : measurement campaign for coverage levels and specifications -90 dbm < < -25 dbm GSM public: measurement campaign for measurements of coverage levels Maximum level -25 dbm Transients: analysis by applying FFT Maximum level -35 dbm

Immunity testing on communications Wave form of the transients based on the statistical distributions: CMU 200 924.8 MHz 1 Double exponential model duration = 5 ns rise time = 0.4 ns Mobile Combiner load 2 Application of Bandpass numerical filter or modulation with a sinus SMIQ GSM Public 925.2 MHz Signal generator 3 - Normalization to 1V peak to peak 4 Variation of the repetition rate

Immunity testing on communications CMU 200 924.8 MHz Mobile combiner Combiner 50 Ω -40 Power (dbm) -50-60 -70-80 without transients GSM Spectrum analyzer Maxhold GSM Public 925.2 MHz Transient -90-100 920 922 924 926 928 930 Frequency (MHz) Railcom final conference, UIC, Paris, 21 april 2009

Immunity testing on communications CMU 200 924.8 MHz Mobile combiner Combiner 50 Ω -40-50 4 µs time interval 10 µs time interval 20 µs time interval Spectrum analyzer Maxhold GSM Public 925.2 MHz Transient Power (dbm) -60-70 -80 1.7 ms time interval without transients Time interval -90-100 920 922 924 926 928 930 Frequency (MHz) Time interval 10 µs for the immunity tests Railcom final conference, UIC, Paris, 21 april 2009

BER and RXQUAL Rxqual: parameter employed to control the quality of the service in situ Quality level i Range of values Typical values of BER

Immunity tests - Results Railcom final conference, UIC, Paris, 21 april 2009

- 17/23 - Railcom final conference, UIC, Paris, 21 april 2009 Impact of public GSM signals 924.8 MHz Mobile Combiner 1 2 3 4 5 6 FREQUENCY POWER (dbm) GSM public FREQUENCY GSM public POWER (dbm) Measured BER (%) RXQUAL GSM Public 925.2 MHz 924.8 MHz -70 925.2 MHz -70 0.004 0-52 0.011 0 + 55 dbm -30 0.01 0-17 0.086 0-15 0.137 1-12 0.44 2

Impact of the transient disturbances in presence of public GSM Transients with TI = 90 µs Transients with TI = 150 µs Transients with TI = 550 µs BER without Transient 2.0 1.6 1.2 0.8 BER (%) Rxqual = 3-60 -50-40 -30-20 -10 0 GSM public power (dbm) 0.4 0.0 Rxqual = 1

BER induced by two different collected transients 924.8 MHz BER (%) 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0.0 power = -70 dbm Railcom final conference, UIC, Paris, 21 april 2009 Mobile Recorded transient D=6.1 ns and RT= 0.35 ns Recorded transient D=6.75 ns and RT= 0.4 ns 0 400 800 1200 1600 Transients time interval (µs) Combiner Signal generator Transients collected on board

Comparisons between measured and estimated BER power = -70 dbm Mobile 924.8 MHz Combiner Transient collected on board RT= 0.35 ns, D= 6.1 ns 0.3 0.2 0.1 (V) 0 0.1 0.2 0.3 0 0.1 0.2 0.3 0.4 Temps (µs) V Signal generator Variable Time interval Time V Double exponential Model RT= 0.4 ns and D= 5 ns t FT () t = A exp exp γ () t BER 1 Rr = 2 R t RT Prediction of the BER S

Comparisons between measured and estimated BER BER (%) 2.0 1.6 1.2 0.8 power = -70 dbm S/N=1 over the duration of the transient estimation du BER (%) transitoire réel modèle de transitoire 1 BER = 2 Rr Rs 0.3 0.2 0.1 (V) 0 0.1 0.2 0.3 0 0.1 0.2 0.3 0.4 Temps (µs) 0.4 0.0 0 200 400 600 800 1000 1200 1400 1600 Intervalle de temps entre les transitoires (µs) Time interval between transients V t FT t RT () t = A exp exp γ () t Double exponential Model RT= 0.4 ns and D= 5 ns

Detection of transient disturbances for diagnostic in-situ

Characterisation of the noise level Over 300 transients -40-50 -60-70 -80 0 50 100 150 200 250 300 Maximal Amplitude 921 MHz - 925 MHz Noise level varies between -40 dbm and -70 dbm Reception level can Vary between About -20 dbm and -92 dbm The definition of a maximum level of noise is not adapted to this application We propose to control the recurrence of the transient disturbances and to compare it with the Rxlevel of the GSM- R signal

Minimum power level to keep a BER inferior to 1.13 % Required Power (dbm) -64-66 -68-70 -72-74 -76-78 -80 BER>1.13 % Variable power Mobile With Collected transient D=6.1 ns, RT = 0.35 ns With Collected transient D=6.75 ns, RT = 0.4 ns BER<1.13 % 0 400 800 1200 1600 Transients time interval (µs) 924.8 MHz Combiner Signal generator

Detection of the transient disturbances Method employed during the project is to «count» the transient is too «heavy» for a diagnostic methodology in situ Approach proposed Reflexion S-parameters of the antennas 0-10 Sii (db) -20-30 -40 S11 - straight antenna S11 - oblique antenna EMI Test Receiver In zero span Measures 1point/3.7 µs -50 300 400 500 600 700 800 900 1000 Frequency (MHz) 850 MHz Free channel Railcom final conference, UIC, Paris, 21 april 2009

Detection of the transient disturbances Approach proposed - Results Arbitrary waveform generator Test sequence -20-30 EMI Test Receiver 70 µs 200 µs Model transient 70 µs 200 µs Real transient Power (dbm) -40-50 -60-70 -80 0.0 0.5 1.0 1.5 2.0 Time (ms) Advantage: we collect 1 point by transient disturbance

Conclusion Complete characterisation of the time characteristics of the transient disturbances produced by the catenary-pantograph sliding contact! Characterisation with a antenna the bandwidth of the antenna can impact the rise time distribution obtained Proposition of a prediction method of the BER induced by the transients observed on board as a function of the repetition rate of the transients Proposition of a laboratory testing method to control the immunity of the communications against EM disturbances representative of the in situ conditions (+ permanent and transient disturbances simultaneously) Proposition of a methodology to preliminary verify the conditions required to guarantee the quality of the communications