MB100 MODEL. STARLINE MINI-BRIDGER SERIES 1GHz AMPLIFIER.

Similar documents
MBV3 1 GHz Amplifier MODEL

The BT87 also offers high gain. This allows the operator to hold existing amplifier locations during system upgrades thereby reducing system costs.

ADVANCED SYSTEM DESIGN PRODUCT SPECIFICATIONS BT*/* STARLINE Broadband Telecommunications Amplifier

STARLINE Series BT100

ADVANCED SYSTEM DESIGN PRODUCT SPECIFICATIONS MBE*/*

MODEL BTN GHz OPTICAL NODE STARLINE SERIES

ASEM MOTO BLE & MB Distribution Amplifiers 1002 MHz

MODEL BLN GHz FIBER DEEP NODE STARLINE SERIES

ASEM C-Cor /Arris Distribution Amplifiers 1002 MHz

GainMaker Unbalanced Triple System Amplifier 870 MHz with 40/52 MHz Split

GainMaker Low Gain Dual System Amplifier 1 GHz with 55/70 MHz Split

ASEM CISCO 1002 MHz RF UPGRADE MODULES

GainMaker High Gain Balanced Triple System Amplifier 1 GHz with 40/52 MHz Split

SDA and ALX MiniFlex Super Distribution Amplifiers 1002 MHz

GainMaker High Output HGBT System Amplifier 5-40/ MHz

GainMaker Line Extender 1 GHz with 42/54 MHz Split

GainMaker Unbalanced Triple System Amplifier 1 GHz with 42/54 MHz Split

GainMaker Line Extender 1 GHz with 65/86 MHz Split

Flex Max RF Amplifiers

Installation and Operation Manual. MB100 1 GHz MiniBridger Amplifier

ACI SDAF MHz Miniflex Configurable Bridger Amplifier

Flex Max. RF Amplifiers FM601e T/B. 1 GHz Trunk and Bridger Amplifiers FEATURES PRODUCT OVERVIEW. arris.com

ACI SDLA. Miniflex Line Extender 1002 MHz

Cisco 1218 MHz GainMaker High Gain Dual (HGD) System Amplifier

rf link 870 mhz mini-bridger

RF LINK 750 MHz FLAMETHROWER MINI-BRIDGER

Diamond Line 3 Single Output Amplifiers

ALX and SDA MiniFlex Super Distribution Amplifiers 750 MHz. Features

GainMaker High Output Node 5-40/ MHz

ALX. 870 MHz Line Extender

GainStar 1 GHz Node with 42/54 MHz Split

GainMaker Optoelectronic Node 1 GHz with 42/54 MHz Split

Cisco 1218 MHz GainMaker High-Gain Balanced Triple System Amplifier

Cisco GainMaker High Output High Gain Balanced Triple 1 GHz System Amplifier 5-85/ MHz

AC2000 AMPLIFIER PLATFORM

RF LINK 750 MHz PAL LINE EXTENDER

Cisco 1.2GHz GainMaker Line Extender (GMLE)

GainMaker Optoelectronic Node 1 GHz with 42/54 MHz Split

1 GHz SASMAX II series

AC3000 INTELLIGENT BROADBAND AMPLIFIER

Broadband System - J

AC500 AMPLIFIER PLATFORM

CXE202 UNIVERSAL AMPLIFIER

GainMaker Optoelectronic Node 1 GHz with 40/52 MHz Split and RF Redundancy

AC1000 AMPLIFIER & OPTICAL NODE PLATFORM

Compact Model Fiber Deep Node 862 MHz with 42/54 MHz Split

RFPD2650 GaAs/GaN Power Doubler Hybrid 45MHz to 1003MHz

Model 6942 Four Port Optoelectronic Node 870 MHz with 42/54 MHz Split

GainMaker High Output Reverse Segmentable Node with 40/52 MHz Split

Model 6940 Four Port Optoelectronic Node 870 MHz with 42/54 MHz Split

750 MHz Magnamax series

CXE202 UNIVERSAL AMPLIFIER

CXE101 DISTRIBUTION AMPLIFIER

AC GHZ DISTRIBUTION AND TRUNK AMPLIFIER

AC3200 INTELLIGENT BROADBAND AMPLIFIER

AC GHZ INTELLIGENT BROADBAND AMPLIFIER

AC8000 FIBRE OPTIC PLATFORM

AC800 FIBRE OPTIC NODE

Diamond Line Type 1 and Type 2 Amplifiers

CXE180 UNIVERSAL AMPLIFIER

AC GHZ INTELLIGENT BROADBAND AMPLIFIER

BDA Broadband Drop Amplifier

BROADBAND DROP AMPLIFIER

ACE3 INTELLIGENT BROADBAND AMPLIFIER

CXE180 UNIVERSAL AMPLIFIER

CXE100 DISTRIBUTION AMPLIFIER

CATV Product Family MEDIALINE 2000

ACE2 INTELLIGENT BROADBAND AMPLIFIER

BDA Broadband Drop Amplifier

Digital Return System

Digital Return System

GainMaker High Output 4-Port Node

Model 6940 Collector/Terminator Three Port Unbalanced Optoelectronic Node 870 MHz with 65/86 MHz Split

TELESTE AC AMPLIFIER MODULES

Opti Max Optical Node Series

STARLINE. SG 2000 Telecommunications Optical Node Installation and Operation Manual

Compact Node Optoelectronics

Downstream signal path (values with diplex filters)

GainMaker 1 GHz High Output 4-Port Node with 40/52 MHz Split

OPTICAL NODE TRUNK & DISTRIBUTION

Model 6944 Four Port Optoelectronic Node 870 MHz with 42/54 MHz Split

Compact Nodes and 90071

ACE8 1.2 GHZ INTELLIGENT OPTICAL NODE

AC9000 INTELLIGENT FIBRE OPTIC PLATFORM

AC9000 INTELLIGENT FIBRE OPTIC PLATFORM

AC8800 INTELLIGENT FIBRE OPTIC PLATFORM

AC GHZ DISTRIBUTION AMPLIFIER

ACA4789: 1218 MHz 25 db Gain CATV Power-Doubler Amplifier

1 GHz, 22 db gain GaAs high output power doubler

TELESTE AC NODE SPECIFIC MODULES

1 GHz, 22 db gain GaAs high output power doubler dbc CSO composite second-order V o = 48 dbmv at 862 MHz

Prisma II 1310 nm High Density Transmitter and Host Module

End of Life. Optical Node Series (HL2) HLN3142C. HL2 Series PWRBlazer II Optical Nodes FEATURES PRODUCT OVERVIEW. arris.com

Prisma II 1 GHz SuperQAM Full Spectrum Transmitter

CXE880 FIBRE OPTIC NODE

ODN4P. Optical Distribution Node, Four Ports. About the Product

amplifiers Phoenix Communication Technologies AMPLIFIERS PAGE DROP AMPLIFIERS DISTRIBUTION AMPLIFIER

= 25 C) Parameter 2.5 GHz 4.0 GHz 6.0 GHz Units Gain db W Power P OUT. = 43 dbm

NCTA RURAL DISTRIBUTION SYSTEMS: A NEW TECHNIQUE FOR SMALL SYSTEM TRUNKING. John A. Hastings. C-COR Electronics, Inc.

Prisma II Multi-Wavelength High Density Transmitter

Transcription:

MODEL MB100 STARLINE MINI-BRIDGER SERIES 1Gz AMPLIFIER Product Overview Motorola s 1 Gz STARLINE MB100 Mini- Bridger Amplifier leads the industry in features and performance. This two-way capable, dual-output amplifier offers high gain, high output levels, ergonomics, superior distortion performance, multiple diplex filter options, 16 db return loss, and Bode equalization, as well as optional advanced features such as ingress control switching and status monitoring. A third output can be configured using a splitter or directional coupler plug-in. Single-output models are also available. Enhanced Gallium Nitride Motorola s STARLINE MB100 1 Gz Amplifiers now feature Gallium Nitride (GaN) Output ybrids to allow for an increased drive level while maintaining existing specifications. The GaN hybrid technology allows for 3 db of increased drive level over the existing Gallium Arsenide (GaAS) technology. The GaN technology also provides for increased reliability that raises the Electro Static Discharge (ESD) levels by 3kV putting them at the reliability level of Silicon (Si) technology. igh Gain The MB100 offers high gain, allowing the operator to hold existing amplifier locations during system upgrades, reducing maintenance, installation, and powering costs. Return Path igh-gain return amplifiers providing 20 db minimum station gain are available. Return path equalizers from 0 to 12 db can be selected. Thermal compensation is an optional feature, available as a plug-in JXP- T*C, which stabilizes gain and match over temperature extremes. Ingress Control Switching (ICS) in three states is also available. This pin diode attenuator circuit can lower levels by 6 db or by 38 db with a controlled slew rate for minimum bit errors. The LIFELINE Mini- Bridger amplifier transponder (available directly from Opterna AM) is required to operate the Ingress Control Switch from a remote location. Features 10 02 Mz Enhanced Gallium Nitride (E- GaN) power doubling technology igh gain igh output level Multiple diplex filter options N -split (5 to 85 Mz /104 to 10 02 Mz) available Ease - of-use ergonomics 16 db return loss 60/9 0 V powering Meets Telcordia GR- 1098 - Core voltage surge requirements using IEEE C62.41 surge waveforms FCC, CENELEC, and CCC approved RoS - compliant models available Bode equalization (thermal or auto controlled) 15 A capability Optional return path ingress control and status monitor Power factor corrected power supply Directional coupler 20 db test points www.amt.com

Forward Path The operational gain of the MB100 is 42 db, with 16 db return loss. Output level control is achieved through the use of an interstage Bode equalizer, which compensates for coaxial cable attenuation changes due to temperature. Equalization may be controlled manually, with a thermal drive unit (TDU), or with a single-pilot closed-loop automatic drive unit, model ADU-* (analog pilot) or QADU-* (QAM pilot). Both the ADU and QADU boards are common to the STARLINE family of amplifiers (with the exception of the SLE and MBV3). ADUs use Surface Acoustic Wave (SAW) filters for determining pilot frequency, improving amplifier stability over temperature. To further ensure system flexibility, installation ease, and maintenance, the amplifier is engineered for compatibility with standard accessories, such as attenuators, equalizers, ADUs or QADUs, return amplifiers, automotive fuses, and FTEC crowbar circuits. The MB100 uses modular diplex filters, which can be changed for a different frequency split as required. The following filters are available for use with all US-style Motorola RF distribution amplifiers (models BLE, MB/ MBV3, BT): K-split (5 to 42 Mz/54 to 1002 Mz) A-split (5 to 65 Mz/85 to 1002 Mz) N-split (5 to 85 Mz/104 to 1002 Mz) Backward Compatibility The MB100 electronics package can be made backward compatible with the MB-15A Kit. These kits contain 50 mil gold plated platform assemblies. This makes it possible for the amplifier to carry 15 Amperes continuous through the input or output ports. For an optional third output, the MB100 uses splitters (model SP100) and directional couplers (model DC100/*). The SP100, DC100/8, DC100/10, and DC100/12 offer superior performance to 1 Gz. Block Diagram +20 db (Status Monitor JXP-B PD Output) -1.0dB +24 db ~ -7.0 db -6.5 db -1.0 db +23 db -4.0 db -1.0dB SFE Therm or JXP-B PP PF RC BODE 4 db Cntrl JXP-B MDR PP tilt -1.7 db F SCS -4.0 db -1.0 db R +20 db L Manual Auto JXP-B PD -1.0dB -1.0dB Input -1.7 db F ADU/ OnBrd port 1 JXP-B RF/ TDU Atten RF L Status -1.0 db R Monitor -1.0dB Input -0.5dB +30.0 db -0.3dB ICS JXP JXP-B -0.4dB -0.4 db -4.0 db -0.4dB SRE TERM JXP-B LPF JXP-B -1.0dB -2.0 db F -4.0 db D C / -16 db SP/ RF RF/ JMP L -1.0dB -1.0dB R 24 Vdc ICS JXP JXP-B -0.4dB RF To status monitor Power supply RF/ RF RF/ Port 2 Port 4 Port 3 Plug-in module DC SP JMP

Specifications MB100K GaN series Specifications Units Notes: Forward Return Frequency split (N) Mz 1 54-1002 5-42 Flatness db 2 +/- 0.7 +/- 0.5 Minimum Full Gain db 3 46 Operation Gain db 4 42 20 Manual Bode Slope Control Range db 5 +3 / -5 Operating Tilt (linear) db 14 18 Interstage Equalizer Slope db 6 14 +/- 1 18 +/-1 Noise figure db 7 8 (10) 8.5 (10.5) 5.5 Reference Frequency Mz 8 1002/550/54 5-42 Reference Output Level 79 analog chs / 450 Mz QAM Reference Output Level dbmv 8 51/44/37 57/48/39 35 (flat) Distortion dbc 21 CCN79 db 54.5 56 CTB79 dbc 9,19 77 73 80 XM79 dbc 10,19 69 62 70 CSO79 dbc 9,11,19 71.5 70 81 Reference Frequency Mz 8 1002/54 948 Mz QAM dbmv 8 51/37 57/39 40 (Flat) NPR db 19 50.5 53 >60 MER db 19 >42 >42 >42 Test Point db 12 20 (+/- 1.0 db) Return Loss db 13 16 15 um Modulation @ 15A dbc 14 <65dB DC Voltage VDC 15 24 DC Ripple mv pkpk 15 p-p Input Voltage Range V 38-90 Current DC ma 16 1475 1610 Power Consumption W 48 50.2 Current Draw A 2-way with ADU @ 90 V 0.55 0.58 @ 75 V 0.68 0.71 @ 60 V 17 0.81 0.85 @ 53 V 0.92 0.97 @ 45 V 1.08 1.14 @ 38 V 1.31 1.37 Bypass Current (all ports) A 17 15A Group Delay, 55.25 to 58.83 Mz nsec 18 52 Operating temperature range C -40 to +60 ousing dimensions, W x x D Inches 15.4 in L x 5.5 in W x 9.6 in D Weight lb 15

MB100N GaN series Specifications Units Notes: Forward Return Frequency split (N) Mz 1 104-1002 5-85 Flatness db 2 +/- 0.7 +/- 0.5 Minimum Full Gain db 3 46 Operation Gain db 4 42 20 Manual Bode Slope Control Range db 5 +3 / -5 Operating Tilt (linear) db 13 17 Interstage Equalizer Slope db 6 14 +/- 1 18 +/-1 (N) Noise figure db 7 8 9 5.5 Reference Frequency Mz 8 1002/550/104 5-85 Reference Output Level 74 analog chs / 450 Mz QAM dbmv 8 51/44/38 57/48/40 35 (flat) Distortion dbc 21 CCN db 55 56.5 CTB dbc 9,19 78 73 80 XM dbc 10,19 69 62 70 CSO dbc 9,11,19 74 72 81 Reference Frequency Mz 8 1002/104 Reference Output Level 898 Mz QAM (Virtual analog levels) dbmv 8 51/38 57/40 40 (Flat) NPR db 19 50.5 53 >60 MER db 19 >42 >42 >42 Test Point db 12 20 (+/- 1.0 db) Return Loss db 13 16 15 um Modulation @ 15A dbc 14 <65dB DC Voltage VDC 15 24 DC Ripple mv pkpk 15 p-p Input Voltage Range V 38-90 Current DC ma 16 1475 1610 Power Consumption W 48 50.2 Current Draw A 2-way with ADU @ 90 V 0.55 0.58 @ 75 V 0.68 0.71 @ 60 V 17 0.81 0.85 @ 53 V 0.92 0.97 @ 45 V 1.08 1.14 @ 38 V 1.31 1.37 Bypass Current (all ports) A 17 15A Group Delay, 109.25 to 112.83 Mz nsec 18 14 Group Delay, 112.25 to 116.63 Mz nsec 18 12 Operating temperature range C 18-40 to +60 ousing dimensions, W x x D Inches 15.4 in L x 5.5 in W x 9.6 in D Weight lb 15

*Specifications are subject to change without notice. *All specifications are stated as worst-case over temperature unless otherwise noted. 1. Operating passband of station. 2. Referenced to the average gain across the passband. 3. Minimum full gain at 1002 Mz includes loss of equalizer but Bode slope reserves have not been set. Return gain includes loss of SRE-*-4 return equalizer. 4. Includes loss of slope reserves as well as equalizer. 5. From midpoint (typical setting is -3 db at 1002 Mz @ 20 C).This control should not be used for gain reduction. 6. Amount of slope created and cable equivalence of fixed, plug- in interstage equalizer. 7. Specified at the housing cable entry facility and includes the loss of 1 db for the pre-stage equalizer. The return noise figure includes the station loss preceding the RF hybrid. 8. Frequencies that relate the picture carriers or QAM channels to the specified output levels and tilts. QAM channels are virtual (-6 db down from analog picture carrier). 9. Measured with CW carriers and spectrum analyzer over specified temperature range. References are typical across the band of interest. * 10. Measured with wave analyzer and synchronous, 100% depth modulated channels. References are typical across the band of interest. * 11. Refers only to beat clusters that fall 0.75 Mz and 1.25 Mz above the subject picture carrier. 12. Test points should be used with GFAL adapter. 13. Match measurement at the station input and output, cable- entry facilities, at the specified passbands for operational gain. 14. Measured with the bypass current. 15. Measured at the power connector. 16. Current draw at 24 VDC. 17. Stated in RMS continuous. 18. Specified for standard NTSC video, where delay is the delta from picture carrier to 3.58 Mz color subcarrier. Reverse delay is in a 1.5 Mz bandwidth. 19. Typical performance over the stated temperature range in a cascade. 20. NTSC 79 Channel forward and 6 channel return, QAM carriers, -6 db relative to the analog CW carriers. 21. Stated specification and performances are referenced with the use of Motorola accessories. The noted parameters will not be supported when third party accessories are employed. 22. NPR - Noise Power ratio, is measured at the center frequency of the band of interest with a full noise load 23. MER Modulation Error Ratio is measured with a BER/MER analyzer and a source using an J.83, Annex datastream. *Specifications are compliant with the test methods as stated in NCTA Recommended Practices for Measurements on Cable

Ordering Information Part Number Model Name Description 821000-014-00 MB100K-2GXX-F-R STARLINE ergonomic 1 Gz MB with 5 42/54 1002 Mz K-split, Manual Gain Control 821000-020-00 MB100K-2GXX-E15-R STARLINE ergonomic 1 Gz MB with 5 42/54 1002 Mz K-split,15 A electronics module only (no housing) 821000-016-00 MB100K-2GAX-F-R STARLINE ergonomic 1 Gz MB with 5 42/54 1002 Mz K-split, ADU 499.25Mz gain control 821000-015-00 MB100K-2GQX-F-R STARLINE ergonomic 1 Gz MB with 5 42/54 1002 Mz K-split, QAM ADU 609.00 Mz gain control 821000-017-00 MB100K-2GSX-F-R STARLINE ergonomic 1 Gz MB with 5 42/54 1002 Mz K-split, QAM ADU 711.00Mz gain control 821000-010-00 MB100K-2GXU-F-R STARLINE ergonomic 1 Gz MB with 5 42/54 1002 Mz K-split 821000-027-00 MB100K-2GXU-E15-R STARLINE ergonomic 1 Gz MB with 5 42/54 1002 Mz K-split, Ultra Slope 821000-023-00 MB100N-2GXX-F-R STARLINE ergonomic 1 Gz MB with 5 85/104 1002 Mz N-split, Manual Gain Control 821000-022-00 MB100N-2GQX-F-R STARLINE ergonomic 1 Gz MB with 5 85/104 1002 Mz N-split, QAM ADU 609.00 Mz gain control 821000-021-00 MB100N-2GQX-E15-R STARLINE ergonomic 1 Gz MB with 5 85/104 1002 Mz N-split, QAM ADU 609.00 Mz gain control, 15 A electronics module only (no housing) 821000-009-00 MB100N-2GXU-F-R STARLINE ergonomic 1 Gz MB with 5 85/104 1002 Mz N-split 821000-024-00 MB100A-2GXX-F-R STARLINE ergonomic 1 Gz MB with 5 65/85 1002 Mz A-split, Full Station, ROS Compliant Required Accessories 535723-001-00 SFE-100-0 STARLINE forward 1002 Mz equalizer (0 db) or 531124-001 to -022 531161-001 to -010 SFE-100-1 to -22 SCS-1 to SCS-10 STARLINE forward 1002 Mz equalizer (values 1 to 22 db in 1 db steps) or STARLINE cable simulator (values 1 to 10 db in 1 db steps) 531163-XXX-00 SRE-*-* STARLINE return equalizer,5 40 Mz (S-split),5 42 Mz (K-split),5 55 Mz (Jsplit),5 65 Mz (A-split),values 0 12 db in 1 db steps for S-split (2 db steps for all other frequency splits) 531186-XXX-00 JXP-*B Plug in attenuator/pad (values 0 to 26 db,in 1 db steps) ( 9 per MB,dual output) Optional Accessories 531230-001-00 SP100 Splitter (1 Gz) to activate third output or 531230-002-00 DC100/8 Directional coupler (1 Gz) to activate third output (8 db) 531230-003-00 DC100/10 Directional coupler (1 Gz) to activate third output (10 db) 531230-004-00 DC100/12 Directional coupler (1 Gz) to activate third output (12 db)

1 Gz MB Ordering Guide RF Configuration 2 Two-port 1 One -port G Gain E-GaAs (igh Output w/ 42 db Gain) GaN (igh Output w/ 42 db Gain) Level Control X A Q None ADU - 499.25/S QADU - 609.00/S F E15 ousing Standard (Full Station) Electronics only (15 amp) S QADU - 711.00/S T TDU MB - - Bandpass Split Return G ain 100K 5-42 Mz / 54-1002 Mz igh (20 db) 100A 100N 5-65 Mz / 85-1002 Mz 5-85 Mz / 104-1002 Mz X Station Slope 14 db (Fmin - 1002 Mz) U 18 db (Fmin 1002 Mz) Notes: 1) Not all combinations in the ordering guide are available. See Ordering Information for available models. 2) FTECs are included in all models as standard. 3) 20 A fuses are included in all amplifiers as standard. 4) ICS and status monitor transponders will continue to be customer-configurable options. 5) For RoS models, add -R to the end of the model string. MOTOROLA and the Stylized M Logo are trademarks or registered trademarks of Motorola Trademark oldings, LLC. All other product or service names are the property of their respective owners. 2012 Motorola Mobility, Inc. All rights reserved. 365-095-14728 x.3 08/12 UNCONTROLLED DOCUMENT - FOR REVIEW ONLY