flowiq 3100 Data sheet

Similar documents
flowiq 3100 Data sheet

flowiq 3101 DATA SHEET

MULTICAL 21 & flowiq 2101

flowiq 2100 Data Sheet

Technical Description MULTICAL 21. Water Meter

Technical Description. flowiq Water Meter

Technical Description. MULTICAL 21 flowiq 2101 /..02 /..03. Water Meter

MULTICAL 302 DATA SHEET

ULTRAFLOW TS PTB. Application. Ultrasonic flow sensor. Compact design. Static meter with no moving parts. Large dynamic range.

ULTRAFLOW. Application. Cooling flow sensor. Ultrasonic flow sensor. Compact design. Static meter with no moving parts. Large dynamic range.

ULTRAFLOW TS Application OIML R75 DS/EN 1434

Applications. Features RESIDENTIAL ULTRASONIC WATER METER. Revenue metering Residential submetering Commercial buildings.

Technical Description MULTICAL 21. flowiq 2101 /..02 /..03. Water Meter

MULTICAL 21. Ultra STRONG and ACCURATE compact water meter based on ULTRASONIC metering

Applications. Features RESIDENTIAL ULTRASONIC WATER METER. Revenue metering Residential submetering Commercial buildings.

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approval with dynamic range up to 1:250 (qi:qp) MID in class 2 (depends on meter size), standard 1:100

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

SonoSelect 10 and SonoSafe 10 Energy Meters

MULTICAL 403. Data sheet

WESAN WP E ELECTRONIC METER WOLTMAN

MULTICAL 601 DATA SHEET

SONOMETER TM 1100 Ultrasonic compact energy meter

SONOMETER TM 1100 Ultrasonic compact energy meter

wprime TM Series 280W-CI ULTRASONIC WATER METER

USB Meter Reader. Data sheet. For reading Kamstrup consumption meters

SonoMeter 31 Energy Meters

Brunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2

MULTICAL 603. Data sheet. The future-proof heat and cooling meter with full flexibility

Wireless M-Bus module for MULTICAL 403

Brunata Optuna H. Properties. Counter

MULTICAL 602 DATA SHEET

Infocal 9 Energy calculator

Installation & User Guide. Multical 402. (Heating & Cooling) Supplied by. .com. Call us on +44 (0)

Technical Description MULTICAL 302. Kamstrup A/S Industrivej 28, Stilling DK-8660 Skanderborg T: kamstrup.

MULTICAL 603. Data sheet. The future-proof heat and cooling meter with full flexibility

Smart Mobile Metering Solutions WALK-BY OR DRIVE-BY READING HYDRUS SMART METERS AND IZAR SYSTEM COMPONENTS

MULTICAL 602. Data sheet. Heat and cooling meters with unlimited communication

RAY MECHANICAL COMPACT METER. 4 MID approved class 2 from ND 15 mm qp 0,6 m3/h up to ND 40 mm qp 10 m3/h

Metering systems 0527EN January 2014 Sanitary water meter, GE552-2 series Versions for wireless centralisation

Technical Description ULTRAFLOW 54 DN

Portfolio. and ULTRAWATER. Ultrasonic Static Meters. Ultrasonic Meters Residential and District Heating/ Cooling Water Measurement

MULTICAL 61. Water Meter. Technical Description

WATERFLUX 3070 Technical Datasheet

RAY COMPACT ENERGY METER MECHANICAL

MULTICAL Energy meter TS PTB. Application

MULTICAL 403. Data sheet

RAY MC COMPACT ENERGY METER MECHANICAL

MULTICAL 602 & ULTRAFLOW

SN+ MID MASTER + APPLICATION WATER METERS

RAY MC COMPACT ENERGY METER MECHANICAL

Residential Water Meters

MULTICAL 62. Water Meter. Technical Description

MID MP-01, MP WATER MEASUREMENT

INFOCAL 8 Energy calculator

Q water 5.5. Electronic water meter. Data sheet DST1-QWA5-EN0 WMEAP / V 2.1

Heat meter Q heat 5 US

ULTRAHEAT / ULTRACOLD T330. The Evolutionary. Ultrasonic Heat Meter / Cooling Meter. Ultrasonic Heat Meter / Cooling Meter.

Release A Member of the

Technical Description ULTRAFLOW 54 ULTRAFLOW 34

EC type-examination certificate UK/0126/0087 Revision 3

ULTRAHEAT / ULTRACOLD T330. The Evolutionary. Ultrasonic Heat Meter / Cooling Meter. Ultrasonic Heat Meter / Cooling Meter.

HDU-SF (Horizontal Distribution Units - Single Flat)

Size : Connection End : Min Temperature : Max Temperature : Materials : Cast iron body

EC type-examination certificate UK/0126/0086 Revision 4

ph or ORP Transmitter

Bulk water meter. All that c ou n t s. EnergyMetering

EW447-EW452 Series Mechanical Heatmeters FOR HEATING AND COOLING APPLICATIONS

Flow Measurement SITRANS F US Inline

MULTICAL 602 & ULTRAFLOW

ultego III smart plus

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver

SONOMETER TM 1000 Ultrasonic compact heat meter

ULTRAHEAT T230 ULTRACOLD T230

INSERTION paddle wheel flowmeter for continuous flow measurement

SONOMETER 2000 Ultrasonic heat meter

Digital inductive conductivity transmitter

SONO 1500 CT Ultrasonic flow sensor

MULTICAL 602 & ULTRAFLOW 34

Technical Description MULTICAL 402

HMU/LPHW LPHW Heat Meters

SVM F27 / C27. Ultrasonic BTU meter for heating or cooling. Data sheet

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview

Metering systems 0474EN April 2018 Domestic water meter

The transducer component converts the measured signal and displays the actual value.

Digital flow transmitter for continuous flow measurement

mass flowmeter for compressed air

TS-9100 Electronic Sensors and Transducers. Features and Benefits. G Wide range of enclosures and signal outputs

Device Manual Chapter 4.1-R optosonic u 3 radio net

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

ULTRASONIC D. Compact ultrasonic heat meter

SVM F27 Compact. Ultrasonic heatmeter. Data sheet

Operating manual IMPORTANT! READ CAREFULLY BEFORE USE. KEEP FOR THE ENTIRE LIFE OF THE PRODUCT. Heat meters. Deltamess TKS-WM compact heat meter

M-Bus Master MultiPort 250L Installation and User Guide

Flow Measurement SITRANS F M

Transcription:

Data sheet flowiq 3100 Pinpoint accuracy Vacuum sealed construction Drive-by or network Long range Long life Built-in Wireless M-Bus Simple installation

Contents Approved meter data 4 Material 4 Technical data 5 Meter sizes 6 Meter details 7 Display and info codes 8 Measurement of temperatures 9 Consumption values 10 Optional registers in data logger 10 Wireless M-Bus wireless radio communication 11 Data registers 13 Pressure loss 14 Ordering details 15 Configuration 16 Dimensioned sketches 17 Dimensions 20 Accessories 20 Electronic ultrasonic meter - for measuring the distribution and consumption of cold water in blocks of flats and commercial premises Pinpoint accuracy Ultrasonic flow measurement guarantees pinpoint measuring accuracy and long life. All measurements, references, readings, calculations and data communication are controlled by an advanced, specially designed, electronic circuit.the electronic meter has no moving parts, meaning that there is no wear and that flowiq 3100 is resistant to any impurities in the water. Vacuum sealed construction flowiq 3100 is constructed as a hermetically vacuumsealed unit, which prevents humidity from reaching the electronics. Therefore condensation water between the glass and the large display is avoided. The meter is waterproof, IP68 type tested, so also suitable for installation in meter pits. The meter has been MID approved and type tested according to OIML R49. Drive-by or network flowiq 3100 comes with the newest radio technology to meet increasing market demands for smart metering, both for drive-by and network installations. Radio packages are available with transmission intervals of 16 or 96 seconds. Long range The meter is equipped with a long range antenna that transmits strong radio signals with intelligent coding to the network. The meter can also be read from a long distance with drive-by. Longevity An internal lithium battery with up to 16 years battery lifetime powers the meter and thus guarantees the meter s total longevity. Built-in Wireless M-Bus flowiq 3100 has built-in radio communication Wireless M-Bus for data communikation on 868 MHz. 2 Kamstrup A/S 58101169_C2_GB_04.2015

Consumption data can be read directly and manually from the display or using an optical eye. Furthermore, consumption data can be remotely read by means of the Wireless M-Bus. Installation The meter housing, which is made of the plastic material PPS, is mounted on a measuring tube of brass or stainless steel, and as the meter can be installed both vertically and horizontally, it is quickly mounted independent of existing piping and installation conditions. The unique combination of pinpoint measuring accuracy, longevity and built-in Wireless M-Bus wireless radio communication reduces the current operating costs of the water supply company measurably. In addition, leakage monitoring helps the utility and the consumer to detect any leaks in the system, with the aim of preventing further loss of water thus minimizing unforeseen costs to the consumer. General description flowiq 3100 is a series of integrated water meters intended for consumption and distribution measurement of cold domestic water. The water meter uses the ultrasonic principle and has been constructed on the basis of Kamstrup s experience since 1991 with the development and production of static ultrasonic meters. flowiq 3100 has been subjected to a very comprehensive OIML R49 type test with a view to securing a long-term stable, accurate and reliable meter. One of the water meter s many advantages is the fact that it has no wearing parts, which entails high immunity towards particles and thereby longevity. The meter housing is constructed as a vacuum chamber of moulded composite material, which is mounted on a measuring tube of brass or stainless steel. Thus, the electronics are fully protected against penetration of water, both from medium pipes and from the environment. The meter is specially suited for small pump stations and distribution wells as well as meter pits which are frequently filled with water. flowiq 3100 is also suited for consumption measurement in big blocks of flats and in commercial buildings. The meter fits perfectly into a network of MULTICAL 21 household meters. The volume is measured using ultrasonic technique which is proven as a long-term stable and accurate measuring principle. Two ultrasonic transducers are used to send sound signals both against and with the flow. The ultrasonic signal travelling with the flow reaches the opposite transducer first. The time difference between the two signals can be converted into flow velocity and subsequently volume. The accumulated water consumption is displayed in cubic metres (m³) with five digits and up to three decimals, i.e. the resolution has been extended to 1 litre only. The large and clear display has been specially designed to obtain long life and sharp contrast in a wide temperature range. In addition to volume reading, a graphic indication of current flow and a number of information codes are displayed. All registers are saved daily in an EEPROM for 460 days. Furthermore, monthly data for the latest 36 months are saved. flowiq 3100 comes with built-in data communication for Wireless M-Bus, 868 MHz, Mode C1 and mode T1 OMS. The meter is fitted with an optical eye which makes it possible to read saved consumption data and info codes, stored in the meter s data logger. Using a serial PC connection, the optical eye furthermore gives access to configure the water meter. The water meter is powered by an internal lithium battery with up to 16 years lifetime. The meter can and must only be opened by Kamstrup A/S. If the meter has been opened and the seals have thus been broken, the meter is no longer valid for billing purposes. Furthermore, the factory guarantee no longer applies. The ultra sonic principle Characteristics in short: OIML R49 type testet electronic ultrasonic meter accurate and reliable no moving parts no wear low start flow hermetically sealed large clear display multiple info codes long-term stable long life powered by a lithium battery suitable for mounting in pits. Kamstrup A/S 58101169_C2_GB_04.2015 3

Approved meter data MID classifications Approval Mechanical environment Electromagnetic environment Climatic environment DK-0200-MI001-017 Class M1 Class E1 and E2 5...55 C, condensing humidity (indoors mounted in utility rooms and outdoors in meter pits mounting in direct prolonged sunligt must be avoided) OIML R49 designations Accuracy class 2 Ambient class Fulfils OIML R49 class B and C (indoors/outdoors) Medium temperature, cold water 0.1...30 C (T30) or 0.1...50 C (T50) Meter type Q3 = 1.6 2.5 4.0 6.3 10 16 and 25 m³/h Material Wetted parts Flow part, threaded DZR brass (dezincification-proof brass) (CW511L) An environmentally friendly brass quality low lead Flow part, flanged Stainless steel W.no. 1.4408 O-ring (gasket) EPDM Measuring tube Polyphenylene sulfide PPS with 40 % fibre glass Reflectors Stainless steel, W.no. 1.4306, 1.4401, AISI316 External meter parts Meter housing Cover Top ring (sealing) Polyphenylene sulfide PPS with 40 % fibre glass Glass Polycarbonate (dyed, blue) 4 Kamstrup A/S 58101169_C2_GB_04.2015

Technical data Electrical data 16-year battery EMC data 3.65 VDC, 1 C cell lithium Fulfils MID class E1 and E2 Mechanical data Metrological class 2 Ambient class Fulfils OIML R49 class B and C (indoors/outdoors) Ambient temperature 2 55 C Protection class IP68 Medium temperature 0.1 30 C (T30) or 0.1 50 C (T50) Storage temp. empty sensor -25 60 C Pressure stage Thread mounted PN16 Flange mounted PN25 Accuracy MPE (maximum permissible error) MPE according to OIML R49 Meter approved 0.1 30 C ± 5 % in range Q1 Q < Q2 ± 2 % in range Q2 Q Q4 At 30 C < t < 50 C 3 % in range Q2 Q Q4 Kamstrup A/S 58101169_C2_GB_04.2015 5

Meter sizes flowiq 3100 is available in different combinations of overall length and nominal flow Q3. Type number Nom. flow Q3 Min. flow Q1 Max. flow Q4 Dynamicområde Q3/Q1 Min. cutoff Max. cutoff Pressure loss p at Q3 Connection on meter Length Check valve Measuring water temperature [m³/h] [l/h] [m³/h] [l/h] [m³/h] [bar] [mm] 031-46-C0A-8XX 1.6 16 2 100 2.0 4.6 0.25 G¾B (R½) 110 No Yes 031-46-C0B-8XX 2.5 25 3.1 100 2.0 4.6 0.04 G¾B (R½) 110 No Yes 031-46-C0C-8XX 2.5 25 3.1 100 2.0 4.6 0.04 G1B (R¾) 190 Yes Yes 031-46-C0G-8XX 4.0 40 5.0 100 3.2 9 0.095 G5/4B (R1) 260 Yes No 031-46-C0H-8XX 6.3 63 7.9 100 5.1 18 0.21 G5/4B (R1) 260 Yes No 031-46-C0J-8XX 10.0 100 12.5 100 8 36 0.13 G2B (R1½) 300 Yes No 031-46-C0L-8XX 16.0 160 20.0 100 13 36 0.19 DN50 270 No No 031-46-C0M-8XX 25.0 250 31.25 100 20 72 0.06 DN65 300 No No 6 Kamstrup A/S 58101169_C2_GB_04.2015

Meter details Meter information in permanent laser engraved text. Optical eye for reading and configuration Graphic flow indicator Type number (includes information on meter size, overall length etc.) Serial number and production year Configuration (with information on display resolution and encryption level etc.) Accuracy class 2 according to OIML R49 Environment class: Electrical E2 and Mechanical M1 according to MID Environment class B and C according to OIML R49 Optional customer label, e.g. water company logo (15x38 mm) Bar code with serial number Expiry year of battery Temperature class according to OIML R49 Meter size Q3 Dynamic range Software version Pressure stage and protection class CE-marking acc. to MID Kamstrup A/S 58101169_C2_GB_04.2015 7

Display and info codes flowiq 3100 can be read from the large, easily readable, specially designed display. The five large figures indicate number of cubic meters. The three small figures are decimals. The sign L (to the right of m³) will always be off when the meter is in operation as it is solely used during factory control and verification of the meter. The flow arrows in the left side of the display indicate water flow through the meter. If there is no flow, all arrows will be off. The info codes in the display have the following meaning and function: Info code Meaning flashes in the display LEAK The water in the meter has not been stagnant for one continuous hour during the latest 24 hours. This can be a sign of a leaky faucet or toilet cistern. BURST The water consumption has been consistently high for half an hour, which indicates a pipe burst. TAMPER Attempt of fraud. The meter is no longer valid for billing. DRY The meter is not water-filled. In this case nothing will be measured. REVERSE The water flows through the meter in the wrong direction. RADIO OFF The meter is still in transport mode with the built-in radio transmitter turned off. The transmitter turns on automatically when the first litre of water has run through the meter. (two square dots ) Two small squares flashing alternately indicate that the meter is active. A followed by a number Indicates the number of metrologic changes the meter has gone through after factory verification. If no adjustments have been made both the A symbol and the digit are inactive. Info codes LEAK, BURST, DRY and REVERSE switch off automatically, when the conditions that activated them no longer exist. In other words, LEAK disappears when the water has been stagnant for an hour, BURST disappears when the consumption falls to normal level, REVERSE disappears when the water no longer flows in the wrong direction, and DRY disappears when the meter is filled with water. 8 Kamstrup A/S 58101169_C2_GB_04.2015

Measurement of temperatures Temperature monitoring flowiq 3100 measures temperatures, water*) and ambient temperature respectively. The measurements can be used to monitor the installation and to give an indication of the quality of the water. Both temperatures are logged in the daily and monthly records. Minimum, mean and maximum values are being registered daily. The register contains the last 460 days. The first day of each month minimum, maximum and average temperatures are stored in the register. The register contains the last 36 months. Temperature values are referred to in C and can be read via the optical eye and sent by the Wireless M-Bus radio signal. Optional temperature combinations in the radio package are described in the section Optional registers in data logger. Ambient temperatures Monitoring the ambient temperature of the installation can be used as a warning of freezing temperatures or unintended high temperatures. The measurement in the meter housing corresponds to the ambient temperature where the meter is installed. The temperature is measured every minute. The calculation of maximum and minimum values is based on a two-minute averaging value. The average temperature is a time-weighted mean value. Water temperatures *) Meassuring the water temperature can be used to give an indication of the quality of the water when it reaches the consumer. Both temperatures are logged in the daily and monthly records. Water temperature is measured as an indirect measurement of the water using the ultrasound signal. The water temperature is measured every 32 seconds. The maximum and minimum values are calculated every 2 minutes based on an average since the latest calculation. Measurement of water temperature requires that the meter is filled with water. If there is no water in the meter a code will be saved, saying that the meter is not water filled. During periods of very low water consumption the water temperature approaches the ambient temperature. To give a correct indication of average water temperature this value is a volume weigthed average. During periods without water flow the weighted average cannot be calculated and then a code is stored. *) Observe! Temperature package in flowiq 3100 is NOT fully available for all sizes, which means that the measurement of the water temperature is ONLY available in the small meter sizes - 1.6 and 2.5 m 3. Kamstrup A/S 58101169_C2_GB_04.2015 9

Consumption values Besides readout of the current totally registered water use the meter saves a number of other consumption data. Following values are stored: Target Volume - i.e. meter reading the first day of the month Maximum flow - daily Maximum flow - monthly Selected values of water temperatures*) and ambient temperatures. Optional registers in data logger Some of the data sent via the Wireless M-Bus radio is optional. It is possible to select one data package - content is illustrated below. The choices are determined by means of the selected R-value when ordering a water meter as shown to the right in the figure. Data collection Ambient temperature Water temperature*) Consumption values R-value Fixed Network Average last day Minimum last day Monthly target volume 3 Maximum flow during last day 9 Minimum last month Minimum last month Monthly target volume 5 Drive-by Maximum last month 7 Meter reading 1 Max. flow during last month 2 *) measured only in meter sizes 1.6 og 2.5 m 3 /h 10 Kamstrup A/S 58101169_C2_GB_04.2015

Wireless M-Bus wireless radio communication flowiq 3100 communicates via built-in Wireless M-Bus, which gives access to quick and easy wireless reading of the meter. Connecting Wireless M-Bus Reader to an antenna on the roof of the car the meter can be read via drive-by. The meter has a long range antenna. Via Wireless M-Bus a data package is transmitted every 16 or 96 seconds according to the selected radio package. The options are Drive-by or Fixed network. When sending a data package every 16 seconds the package is kept short and compressed to achieve a long battery life. At 96 second intervals, a longer and intelligent radio package with built-in repair coding is sent the long battery life is still guaranteed since the transmission interval is increased. The following details are transmitted: Current meter reading Optional register combination of: Target volume monthly/ max. flow/water and ambient temperatures List of active info codes List of info codes which have been active within the latest 30 days. The list of info codes which have been active also includes information on how long they have been active. Wireless M-Bus communication is in accordance with the open standard EN 13757: 2013 and flowiq 3100 can be configured with or without encryption of Wireless M-Bus signal. Encryption is performed using 128 bit AES encryption. Encryption protects personal data against unauthorised monitoring. Furthermore, the encryption file provides easy access to import of meter data into reading programs. Kamstrup A/S recommends encryption. flowiq 3100 can be read by using for example the READy Kamstrup s mobile Android app which is ideal for walk-by and drive-by reading. To the right, previews of how a reading may appear on the user s smart phone. Kamstrup A/S 58101169_C2_GB_04.2015 11

Wireless M-Bus wireless radio communication Below, an example of the graphics from the READy Manager program on the PC. 12 Kamstrup A/S 58101169_C2_GB_04.2015

Data registers flowiq 3100 has a permanent memory (EEPROM) in which the values of various data loggers are saved. The meter includes the following registers: Data logging interval Data logging depth Logged value Monthly logger 36 months See table below Daily logger 460 days See table below Info logger 50 events Info code, meter reading and date It is always possible to read target volume and info codes for each of the latest 36 months as well as corresponding meter reading and possible info codes for each of the latest 460 days. The loggers can only be read via the meter s optical eye. The following registers are logged: The monthly logger is written on the first day of the month, the daily logger is written at midnight. Register type Description Monthly logger, 36 months Daily logger, 460 days Date (YY.MM.DD) Logging time, year, month and day Volume Current meter reading (legal) Operating hour counter Accumulated number of operating hours Info Information code Vol. Reverse Volume during reverse flow Date of max. flow Date stamp of max. flow during period Max. flow Value of max. flow during period Date of min. flow Date stamp of min. flow during period Min. flow Value of min. flow during period *)Min. temp. water *)Max. temp. water *)Mean temp. water Water temperature minimum Water temperature maximum Volume weighted mean water temp. Ambient temp. min.. Ambient temp. max. Ambient temp. mean. Meter temperature minimum Meter temperature maximum Meter temp. time weighted average *) applies only for meter sizes 1.6 and 2.5 m 3 /h Every time the information code changes, date and info codes are logged. Thus, it is possible to data read the latest 50 changes of the information code as well as the date the change was made. Reading is only possible via the optical eye. Kamstrup A/S 58101169_C2_GB_04.2015 13

Pressure loss According to OIML R49 the maximum pressure loss must not exceed 0.63 bar (0.063 MPa) in the range Q1 to Q3. The pressure loss in a meter increases with the square of the flow and can be stated as: Q=k v x p where: Q = volume flow rate [m³/h] k v = volume flow rate at 1 bar pressure loss p = pressure loss [bar] Graph Q3 [m 3 /h] Nom. diameter [mm] k v Q at 0.63 bar [m 3 /h] B 1.6 & 2.5 DN15 & DN20 6 4.8 C 4.0 & 6.3 DN25 13 10 D 10.0 DN40 28 22 E 16.0 DN50 37 29 F 25.0 DN65 102 81 14 Kamstrup A/S 58101169_C2_GB_04.2015

Ordering details An order is initiated by stating the type number of the selected model of flowiq 3100. The type number includes information on meter type - cold or hot water, meter size, overall length, battery life, country code etc. Some of the features included in the type number cannot be changed. Subsequently, the meter configuration, which determines customer specific requirements such as number of digits in display etc., is selected. The configuration is completed during programming of the finished meter. Finally, required accessories, if any, in the form of gaskets, different extension pipes, non-return valve, strainer and standard couplings are selected. Accessories are enclosed separately to be mounted by the installer. flowiq 3100 Type 031 0 Communication Wireless M-Bus, 868 MHz, Mode C1, ver. 2 46 Wireless M-Bus, 868 MHz, Mode T1 OMS, ver. 2 *) 47 *) only for selected markets Supply 16 years battery life C Meter size Q3 [m 3 /h] Connection Length [mm] Dynamic range 1.6 G¾B (R½) 110 100 A 2.5 G¾B (R½) 110 100 B 2.5 G1B (R¾) 190 100 C 4 G5/4B (R1) 260 100 G 6.3 G5/4B (R1) 260 100 H 10 G2B(R1½) 300 100 J 16 DN50 270 100 L 25 DN50 300 100 M Meter type Cold water meter 8 Country code (language on label etc.) XX The country code is used for: Language and approval on type label Temperature class of cold water meter (T30 and T50) Kamstrup A/S 58101169_C2_GB_04.2015 15

Configuration KK LLL MMM N P R S T Target date (fixed) 01 Average time of max. values 2 minutes 002 Customer label 2005-MMM MMM Leakage message limit OFF 0 Flow continuously > 0.5 % of Q3 1 Flow continuously > 1.0 % of Q3 2 Flow continuously > 2.0 % of Q3 3 Flow continuously > 0.25 % of Q3 4 Flow continuously > 0.1 % of Q3 5 Pipe burst limit OFF 0 Flow > 5 % of Q3 for 30 minutes 1 Flow > 10 % of Q3 for 30 minutes 2 Flow > 20 % of Q3 for 30 minutes 3 Optional register in data logger * ) Reccommended for Drive-by ** ) Reccommended for Fixed network Meter reading target date 1 Max. flow during last month 2 Monthly target volume / Min.temp.water - daily / Time weighted average temp. meter - daily **) 3 Monthly target volume / Min. water Temperature - Monthly / Min. temp. meter - latest month *) 5 Monthly target volume / Min. water Temperature - Monthly / Max. temp. meter - latest month *) 7 Daily max. flow / Min.temp.water-daily / Time weighted average temp. meter- daily **) 9 Measuring water temp.- applies only for meter sizes 1.6 and 2.5m 3 /h Display resolution 00001 m³ 0 00000.1 m³ 1 00000.01 m³ 2 00000.001 m³ 3 Encryption level No encryption 0 Utility encryption (only available for selected markets) 2 Encryption with separately forwarded key 3 Unless otherwise stated in the order, Kamstrup supplies the following: 01 002 000 1 3 5 3 3 16 Kamstrup A/S 58101169_C2_GB_04.2015

Dimensioned sketches Type: A Q3 1.6 m³/h G¾B (R½) x 110 mm B Q3 2.5 m³/h G¾B (R½) x 110 mm 110 Type: C Q3 2.5 m³/h G1B (R¾) x 190 mm 190 Type: G Q3 4 m³/h G5/4B x 260 mm H Q3 6.3 m³/h G5/4B x 260 mm 260 260 Kamstrup A/S 58101169_C2_GB_04.2015 17

Dimensioned sketches Type: J Q3 10 m³/h G2B x 300 mm 300 300 Type: L Q3 16 m³/h DN50 x 270 mm 270 268 18 Kamstrup A/S 58101169_C2_GB_04.2015

H flowiq 3100 Dimensioned sketches Thread ISO 228-1 B Flanged meter, type L L L1 L1 65 ø18 (for M16 bolt) 165 DN 125 H Flanged meter, type M 185 Ø78 300 DN Ø145 H Kamstrup A/S 58101169_C2_GB_04.2015 19

Dimensions Q3 Thread on L1 H B Weight ~ Meter type [m³/h] meter [mm] [mm] [mm] [kg] 1.6 G¾B (R½) 110 97 91.6 1.05 A 2.5 G¾B (R½) 110 97 91.6 1.05 B 2.5 G1B (R¾) 190 97 91.6 1.8 C 4.0 G5/4B 260 89.5 91.6 2.5 G 6.3 G5/4B 260 89.5 91.6 4.7 H 10.0 G2B 300 104.5 91.6 4.7 J 16.0 DN50 270 165 165 8.5 L 25.0 DN65 300 185 185 12.0 M Accessories See Accessories for Water Meters: 5810-1270-GB Kamstrup A/S 58101169_C2_GB_04.2015 Kamstrup A/S Industrivej 28, Stilling DK-8660 Skanderborg T: +45 89 93 10 00 F: +45 89 93 10 01 info@kamstrup.com kamstrup.com Think forward 20 Kamstrup A/S 58101169_C2_GB_04.2015