SC SC230 (AS05710/115V- AS05711/115V) Apparecchiatura elettronica SCHEMA ELETTRICO E COLLEGAMENTI Electronic control unit ELECTRICAL CNECTIS I UK
2 SC230 SCHEMA ELETTRICO / ELECTRICAL CNECTIS 91 G:B:D:055G3 F1 F0.5A F3 F0.5A PAUSE FORCE SENS. SLOW SW1 PED OFF OFF 3 4 5 6 7 8 9 10 SW4 DL8 START LED DL1 DL2 DL3 DL5 DL6 DL8 DL9 DL10 PED START PHOTO FCA FCC IND. SAFETY STOP-SAFETY T1 U8 DL6 DL5 DL3 L1 K4 U2 U3 DL9 DL10 DL2 DL1 K2 K3 K6 Q3 E FINECORSA CHIUDE CLOSING LIMIT SWITCH F2 F5A K1 EXTERNAL CAPACITOR K5 Q4 E FINECORSA APRE OPENING LIMIT SWITCH CN3 CN2 CN5 CN4 115Vac 3 4 5 6 7 CLOSE M 115Vac 40W MAX OPEN PHASE NEUTRAL LAMP LAMP J2 3W MAX
SC230 3 COLLEGAMENTO ALIMENTAZIE / POWER SUPPLY CNECTI 2 INTERRUTTORE MAGNETOTERMICO OVERCURRENT CIRCUIT BREAKER NEUTRAL PHASE NEUTRAL PHASE 115Vac INTERRUTTORE DIFFERENZIALE RESIDUAL-CURRENT DEVICE COLLEGAMENTO DI TERRA / EARTH CNECTI 3 CN3 CN2 COLLEGAMENTO MOTORE / MOTOR CNECTI 4 3 4 5 6 7 3 4 5 6 7 CAVO NERO / BLACK CABLE CAVO BLU / BLUE CABLE CAVO MARRE / BROWN CABLE CAVO MARRE / BROWN CABLE CAVO BLU / BLUE CABLE CAVO NERO / BLACK CABLE
SC230 4 INSTALLAZIE SENZA RALLENTAMENTI / INSTALLATI WITHOUT DECELERATIS 22 31 6 STOP STOP APERTURA CHIUSURA CLOSING OPENING INSTALLAZIE C RALLENTAMENTI / INSTALLATI WITH DECELERATIS 22 31 22 31 7 STOP STOP INIZIO RALLENTAMENTO IN CHIUSURA DECELERATI START IN CLOSING CHIUSURA CLOSING X2 INIZIO RALLENTAMENTO IN APERTURA DECELERATI START IN OPENING APERTURA OPENING X2
SC230 5 COLLEGAMENTO CDENSATORE / CAPACITOR CNECTI 8 F2 F5A EXTERNAL CAPACITOR 115Vac 3 4 5 6 7 COLLEGAMENTO LAMPEGGIANTE / FLASHING LIGHT CNECTI 4 9 115 Vac 40W max DIP SWITCH 3 3 4 5 6 7 Ref LAMP LAMP OFF 3 on off 3s on off 3s OFF 3 on off on off COLLEGAMENTO DISPOSITIVI DI ANDO / CTROL DEVICES CNECTI 410 Q3 Q3 K3 K1 K5 Q4! F2 F5A K3 K1 EXTERNAL CAPACITOR K5 Q4 CN3 CN2 CN5 CN4 CN3 CN2 CN5 CN4 J2 115Vac 3 4 5 6 7 J2 CDENSATORE CAPACITOR
6 SC230 COLLEGAMENTO FOTOCELLULE / PHOTOCELLS CNECTI CSULTARE IL MANUALE DELLE FOTOCELLULE PER MAGGIORI DETTAGLI / REFER TO THE PHOTOCELLS MANUAL FOR DETAILED CNECTI DIAGRAMS 411 COLLEGAMENTO FOTOCELLULE C TEST / PHOTOCELLS CNECTI WITH TEST 12 413 414 2 3 3 4 1 3 3 4 COLLEGAMENTO FOTOCELLULE / PHOTOCELLS CNECTI COLLEGAMENTO FOTOCELLULE C TEST / PHOTOCELLS CNECTI WITH TEST ( AU02000 SINCRIZZATE / SYNCHRIZED ) ( AU01900 - AU01910 SINCRIZZATE / SYNCHRIZED ) 3 4 3 4 2 3 3 4 1 3 3 4 ( AU02000 SINCRIZZATE / SYNCHRIZED ) 3 4 5 3 4 5 3 4 3 4 3 4 5 ( AU01900 - AU01910 SINCRIZZATE / SYNCHRIZED ) 3 4 5
SC230 7 COLLEGAMENTO DISPOSITIVO DI SICUREZZA NC / NC SAFETY DEVICE CNECTI 415 NC NC NC COLLEGAMENTO DISPOSITIVO DI SICUREZZA / SAFETY DEVICE CNECTI 416 COLLEGAMENTO DISPOSITIVO DI SICUREZZA NC AGGIUNTIVO / ADDITIAL NC SAFETY DEVICE CNECTI 417 OFF 10 DIP SWITCH 10 = NC NC NC COLLEGAMENTO DISPOSITIVO DI SICUREZZA AGGIUNTIVO / ADDITIAL SAFETY DEVICE CNECTI 418 OFF 10 DIP SWITCH 10 =
8 SC230 COLLEGAMENTO STOP / STOP CNECTI 19 431 OFF 10 DIP SWITCH 10 = OFF COLLEGAMENTO DI SEGNALAZIE / WARNING LIGHT CNECTI 420 3W MAX COLLEGAMENTO E GIRI MOTORE / MOTOR RPM 421 NERO - BLACK MARRE - BROWN BLU - BLUE
SC230 9 IMPOSTAZIE DI DEFAULT DIP SWITCH SW1 / DIP SWITCH SW1 DEFAULT SETTINGS 22 MORSETTO 12 E COSTA 8k2 / TERMINAL 12 AS 8k2 SAFETY EDGE 4 E GIRI MOTORE ABILITATO / MOTOR RPM ENABLED RICHIUSURA RAPIDA ABILITATA / FAST CLOSING ENABLED RALLENTAMENTI ABILITATI / DECELERATI ENABLED CHIUSURA AUTOMATICA DISABILITATA / AUTOMATIC CLOSING DISABLED FOTOCELLULA IN APERTURA ABILITATA / PHOTOCELL DURING OPENING ENABLED - TEST SICUREZZE ABILITATO - SAFETY DEVICES TEST ENABLED PRELAMPEGGIO ABILITATO / PRE-FLASHING ENABLED LOGICA DI FUNZIAMENTO / WORKING LOGIC 3 4 5 6 7 8 9 10 OFF MORSETTO 12 E STOP 8k2 / TERMINAL 12 AS 8k2 STOP E GIRI MOTORE DISABILITATO / MOTOR RPM DISABLED RICHIUSURA RAPIDA DISABILITATA / FAST CLOSING DISABLED RALLENTAMENTI DISABILITATI / DECELERATI DISABLED CHIUSURA AUTOMATICA ABILITATA / AUTOMATIC CLOSING ENABLED FOTOCELLULA IN APERTURA DISABILITATA / PHOTOCELL DURING OPENING DISABLED TEST SICUREZZE DISABILITATO - SAFETY DEVICES TEST DISABLED PRELAMPEGGIO DISABILITATO / PRE-FLASHING DISABLED OFF-OFF = PASSO-PASSO C STOP / STEP BY STEP WITH STOP -OFF = PASSO-PASSO / STEP BY STEP OFF- = CDOMINIALE / AUTOMATIC - = UOMO PRESENTE / DEAD MAN IMPOSTAZIE DI DEFAULT DIP SWITCH SW4 / DIP SWITCH SW4 DEFAULT SETTINGS 33 LEGGERE IL MANUALE PRIMA DI MODIFICARE LE IMPOSTAZII DI DEFAULT READ THE MANUAL BEFORE MODIFYING DEFAULT SETTINGS FRENATURA ELETTRICA ABILITATA ELECTRIC BRAKE ENABLED TENTATIVI MULTIPLI DOPO INTERVENTO SICUREZZE DISABILITATO ADDITIAL ATTEMPTS AFTER SECURITY DEVICES INTERVENTI DISABLED OFF FRENATURA ELETTRICA DISABILITATA ELECTRIC BRAKE DISABLED TENTATIVI MULTIPLI DOPO INTERVENTO SICUREZZE ABILITATO ADDITIAL ATTEMPTS AFTER SECURITY DEVICES INTERVENTI ENABLED TRIMMER PAUSE 34 PAUSA 2 SECDI PAUSE 2 SECDS TEMPO PAUSA 220 SECDI PAUSE 220 SECDS
10 SC230 TRIMMER FORCE 25 31 { MOVEMENT SPEED : 50% - THRUST FORCE: 25% VELOCITA ANTA : 50% - FORZA DI SPINTA : 25% MOVEMENT SPEED : 100% - THRUST FORCE: 25% VELOCITA ANTA : 100% - FORZA DI SPINTA : 25% MOVEMENT SPEED : 100% - THRUST FORCE: 50% VELOCITA ANTA : 100% - FORZA DI SPINTA : 50% MOVEMENT SPEED : 100% - THRUST FORCE: 100% VELOCITA ANTA : 100% - FORZA DI SPINTA : 100% TRIMMER SENS 36 SENSIBILITA INTERVENTO E ANTISCHIACCIAMENTO INTERVENTI SENSITIVITY OF ANTICRUSHING ALTA SENSIBILITA HIGH SENSITIVITY MEDIA SENSIBILITA MEDIUM SENSITIVITY BASSA SENSIBILITA LOW SENSITIVITY
SC230 11 TRIMMER SLOW 37 { RALLENTAMENTO DECELERATI { RALLENTAMENTO DECELERATI MOVEMENT SPEED : 50% - THRUST FORCE: 25% VELOCITA ANTA : 50% - FORZA DI SPINTA : 25% MOVEMENT SPEED : 100% - THRUST FORCE: 25% VELOCITA ANTA : 100% - FORZA DI SPINTA : 25% MOVEMENT SPEED : 100% - THRUST FORCE: 50% VELOCITA ANTA : 100% - FORZA DI SPINTA : 50% MOVEMENT SPEED : 100% - THRUST FORCE: 100% VELOCITA ANTA : 100% - FORZA DI SPINTA : 100%
Cod. AIC8979 - Rev. 00 03/2016 GI.BI.DI. S.r.l. Via Abetone Brennero, 177/B 46025 Poggio Rusco (MN) - ITALY Tel. +39.0386.52.20.11 Fax +39.0386.52.20.31 E-mail: info@gibidi.com Numero Verde: 800.290156 w w w. g i b i d i. c o m