MINIMUM REQUIREMENTS FOR A DARKROOM.

Similar documents
Guide to Manual Processing of NDT Films

Anatomix Plus X-Ray System

Anatomix RP X-Ray System

50 Tips for Manual Processing

RD-90 Developer-Replenisher F-Fix Fixer-Replenisher

Film and processing quality assurance

5 Using KODAK EKTACOLOR RA Chemicals with Tray, Drum, and Rotary-Tube Processors

Multiple Choice Identify the letter of the choice that best completes the statement or answers the question.

Processing and. Photography. Printing

ILFORDINFO HOW TO PROCESS YOUR FIRST BLACK AND WHITE FILM

KODAK T-MAX 100 Direct Positive Film Developing Outfit

Radiology. Radiograph: Is the image of an object made with use of X- ray instead of light.

KODAK INDUSTREX AA400 Film Versatility is the key.

Fig. 1. A. Adjustable section of film holder. B. Notched portion. C. Projection guides. D. Back stop

Processing Film. How do I develop and fix the latent image on my film so I can make prints? By Marcine Linder

RA Duplicating Film X-OMAT 5000 RA Processor; RP X-OMAT Chemicals; 90 Second Cycle; Diffuse Visual Densitometry. Density

KODAK Simulation Film / 7157

Autofluor. Autoradiographic Image Intensifier. Documented... Autofluor is Superior! C 3 PPO-DMSO. Autofluor

KODAK PROFESSIONAL T-MAX P3200 Black & White Negative Film

KODAK PROFESSIONAL T-MAX P3200 Black & White Negative Film

10 ROTARY-TUBE PROCESSORS

imaging guide metalphoto 400 PROCESSING

KODAK PROFESSIONAL TRI-X 320 and 400 Films

KODAK PROFESSIONAL Display and Print Materials

Nash Chandelier Assembly and Installation Instructions

EASTMAN TRI-X Reversal Film 7278

The Silver Gelatin Photographic Print

KODAK PROFESSIONAL AZO Paper

ISO 400/27 o BLACK AND WHITE PROFESSIONAL FILM FOR HIGH PRINT QUALITY AND FLEXIBILITY IN USE

KODAK X-OMAT BT Film / 4530 / XBT

KODAK MIN-R S Film / 4906

KODAK Medical X-ray Film / General Purpose / Blue / 3528 / MXB

Capillary Film Troubleshooting. Pinholes. Stencil underexposed

SPRINGFIELD TECHNICAL COMMUNITY COLLEGE ACADEMIC AFFAIRS

NOTES ON PRINTING 08/06

CAUTION: BEFORE INSTALLING THE LUMINAIRE, MAKE SURE THAT THE CURRENT IS CUT TO THE BOX FUSES / MAIN CIRCUIT BREAKER.

TECHNICAL DATA / COLOR PAPER July 2003 E-19

INTRODUCTION TO THE FPC PROCESS CONTROL

KODALITH Ortho Films 2556,6556, Type 3

TECHNICAL DATA / COLOR PAPER July 2003 E-23

TECHNICAL INFORMATION Küsnacht, February 2004 (rev. 1/09) THICKFILM STENCILS FOTECOAT 1845 SOLO

KODAK PROFESSIONAL T-MAX Developers

KODAK PROFESSIONAL POLYCONTRAST III RC Paper

MULTIGRADE FB WARMTONE 1

Cornerstone Electronics Technology and Robotics I Week 19 Soldering Tutorial

KODAK EKTACHROME RADIANCE III Paper

INDUSTREX Film. For Non-Destructive Testing WHEN CLARITY IS CRITICAL

FORMULARY P.O. Box 950 Condon MT FAX

Woven Leather Chandelier Large Assembly and Installation Instructions

KODAK ROYAL Digital Paper

Suggested Specification for Preparing Hot-Dip Galvanized Steel Surfaces for Painting Revised February 2002

Darkroom printing. Pictionary_tutorial

SECTION 10. SAFETY METHODS FOR TURNBUCKLES

TECHNICAL INFORMATION

To help you learn tiiasctfql. to learn to develop, print, and enlarge m OREGON STATE COLLEGE

KODAK PROFESSIONAL PRO IMAGE II Paper

Contains chemicals to make approximately 24 8 x 10 prints

DEVELOPMENT. The following developers are recommended: Ilford ID-2 Developer For Fine Grain Safety Positive Film.

Making a Surface Coating Kersti Cox, Miami University, Oxford, OH

EASTMAN PLUS-X Reversal Film / 7276

E3 UV-30 Resist Film Instructions

Homemade Copper Solar Cells

FOCUS TECHNOLOGY THE BEAUTY OF A LACQUERED SURFACE

Infrared Thermometer Remote Temperature Measurement ( Non-Contact ) 1327 INSTRUCTION MANUAL

Photo graph ic Sens itizer for Cloth and Pape r

KODAK TRI-X Pan and KODAK TRI-X Pan Professional Films

KODAK VERSALITE TDF Film

KODAK IMAGELITE ESY Scanner Film KODAK GEN 5 GAI Recording Film KODAK IMAGELITE IRF Scanner Film KODAK GEN 5 GIR Recording Film

TECHNICAL INFORMATION

MADELINE METAL CHANDELIER

TECHNICAL INFORMATION MULTIGRADE IV FB FIBER PREMIUM QUALITY VARIABLE CONTRAST PAPER ON A FIBER BASE ILFORD

FUJICOLOR CRYSTAL ARCHIVE PAPER TYPE CA

How to Print: Making an Enlargement from a Negative in the Darkroom

DELTA PROFESSIONAL ILFORD FACT SHEET ISO 400/27º, FINE GRAIN, BLACK AND WHITE PROFESSIONAL FILM FOR SUPERB PRINT QUALITY F.

Sign Maintenance. Sign Maintenance

Custom Pendant- Hardwire Assembly and Installation Instructions

BLACK AND WHITE, ORTHOCHROMATIC COPY FILM

ISO 400/27º, BLACK AND WHITE PROFESSIONAL FILM FOR HIGH PRINT QUALITY AND FLEXIBILITY IN USE

FUJICOLOR CRYSTAL ARCHIVE PAPER SUPREME <NEW>

Dental Radiography Series

400 PROFESSIONAL FACT SHEET ISO 400/27º, FINE GRAIN, BLACK AND WHITE PROFESSIONAL FILM FOR SUPERB PRINT QUALITY. September 2002

Pacific Antenna SLT+ Switched Long wire Tuner

Bright Precious Metal Preparations for the Production of Decals for Glass

Operation Manual K

IMAGE PROCESSING AND CONTROL

SOLVENTS & RETARDERS STANDARD BUTYL CARBITOL PROPYLENE GLYCOL BUTYL CELLOSOLVE VINYL WASH THINNER N-116 XYLOL INK DEGRADIENT HO 1000 VARSOL

SURFACE FINISH. A galvanized finish is MnDOT s standard on new traffic control signal poles, mast arms, transformer bases, and luminaire extensions.

Wimberley Developer #2, Version D+ 1 liter kit (Dry) CATALOG NO TO MAKE 50 LITERS OF WORKING SOLUTION

Arched Top Lantern Pendant Assembly and Installation Instructions. Country of Destination: US/CN UK/EU/AUS Middle East

PAPER No. 7: Criminalistics & Forensic Physics MODULE No. 31: Black & White & Colour Film Processing and Printing. and Printing

ROPE CHANDELIER - FRAME ASSEMBLY & INSTALLATION INSTRUCTIONS

Troubleshooting. Agfa Dentus Intraoral radiography Troubleshooting Guide. Giving a hand to oral health.

Polymer Plate Development Procedures. (800) or (802) (800)

Light Enhancement Film

APPENDIX D AN ALTERNATIVE PROCESS WORK SPACE

LECTURE 1 The Radiographic Image

Technical Notes. Introduction. Optical Properties. Issue 6 July Figure 1. Specular Reflection:

KODAK PROFESSIONAL KODABROME II RC Paper

ARS-IMAGO CHEMICALS DATA SHEETS

KODAK Panchromatic Separation Film 2238

Transcription:

1 THE DARKROOM Neill Serman. Aug, 2000 W + P. Ch. Pages 97 - It is important that the darkroom be designed to make film processing an efficient, precise and standardized procedure. Since processing procedures are carried out in near total darkness, every piece of equipment must be in its specific place. For efficiency's sake, the room should be large enough to avoid crowded conditions and the equipment should be arranged so as to expedite the flow of work and be within arms reach. A dark room does not mean that one is obligated to process manually. It should be located as close as possible either to the X-ray clinic or the reading area. A light-tight darkroom does not mean that the walls must be painted black; walls should be of a light pastel color to reflect the room illumination. If humidity is a problem, especially in certain parts of the country, air conditioning is a must. When the temperature of the processing room exceeds 90. degree F, the X-ray films may become sensitized (fogged) by heat alone. MINIMUM REQUIREMENTS FOR A DARKROOM. a) Light-tight room b) Both safe-light and white-light illumination c) Processing tanks and / automatic processor d) Hot and cold running water e) Accurate thermometer and interval timer f) Drying racks or dryer g) Adequate storage space h) A radiograph viewer i) Has a light-tight storage draw for unexposed extra-oral film a) LIGHT-TIGHT PROCESSING ROOM The first requisite of a processing room is the exclusion of all external white light when radiographs are processed. Photosensitive crystals in dental film emulsions are extremely sensitive to visible light, and any light leaking around a door or window may fog and ruin the films. Many people advocate a door that can be locked to avoid accidental exposure of film to white light. Alternatively a light outside the door indicating that the darkroom is in use. When the white light in the darkroom is switched off, the indicating light outside automatically goes on. A maze walk in is helpful for heavy traffic in and out of the darkroom. Where a maze is incorporated, the maze must be painted black to prevent white light from scattering into the darkroom. Inevitably there will be some light leaks in the darkroom and may be tested as follows. Place 6 coins on unexposed films that have been removed from the wrapping, on the working surface. Process one of the films every 30 seconds. The first four films should not show the outline of the coin indicating that it takes at least 2 minutes of the film being exposed before fogging will occur. The same test should be carried out to test the "safe-light". Check ceiling tiles and doorways for light leaks. b) SAFELIGHT

2 The processing room must be provided with both white and safelight illumination. White light for such work as cleaning tanks and preparing the solutions is done. Reliable safe-light lamps are indispensable - their function is to provide adequate light of quality that is safe for exposed X-ray films during handling and processing. Always remember that X-ray films are sensitive to light until after fixation. Since excessive exposure of the film to safelight illumination will result in fog, three factors concerning safelight lamps must be carefully considered: i) Type of filter ii) Intensity of illumination a) Wattage of bulb b) Distance of safelight lamp above working area Time film is exposed to the safe light. No light is completely safe i) TYPE OF FILTER. X-ray films have the highest sensitivity to the blue-green part of the light spectrum. The X-ray film is less sensitive to light in the opposite region of the spectrum - i.e. the yellow and red region. It is obvious that the blue filter cannot be used, neither a green color filter as it is so close to the blue. Therefore safelights are safest when made with amber or red filters. Since yellow is closer to green than red in the spectrum, one can see better under a yellow filter than a red filter. This is the basis of using film emulsions which are not sensitive to the yellow light. Never use a ruby or red light bulb as a safelight. While the light from such a bulb may look safe because it is dim, such illumination will probably cause fogging of the X-ray films. In order to use the least amount of light for the safelight lamp, the Wratten series 6B OR Morlite 2 (ML 2) filter is the filter of choice. This filter transmits light predominantly in the yellow-red portion of the spectrum. ii) INTENSITY OF ILLUMINATION The intensity of illumination of the safelight is controlled by wattage of the bulb and the distance of the safelight from the working surface. The recommended minimum distance for the safelight lamps is 120cms (4 feet) above the working surface. Thus, if using the E- speed plus film you should use a 7 1/2 watt bulb at this distance. The inverse law applies to light illumination: the intensity of light varies inversely as the square of distance. In brief, if we have X intensity at 4 feet, we will have 4 x intensity at 2 feet and 1/4 x intensity at 8 feet. Therefore, the intensity of safelight illumination on the film varies with distance and also with the wattage of the bulb. The correct intensity can be obtained by adjusting either the distance or the bulb wattage or both. Textbooks quote a 15 watt bulb but that is for D speed film. THE TIME THE X-RAY FILM IS EXPOSED TO SAFELIGHT

3 It must be made clear that there is no such thing as an absolutely safe safe-light. The film will be fogged if it is exposed too long to any intensity light. The question arises now for how long can a film be exposed to safelight illumination before fog becomes apparent. ILLUMINATION SAFETY TEST A simple method of checking the safelight is the same as for the dark room: remove 6 dental film from their packets and lay them on the working surface of the bench beneath the safelight lamp. Place a small coin on each film. Expose each film to the safelight conditions as explained above. Process in the usual manner. Examine each film before an illuminator. If you can see the faintest outline of the coin on the film exposed to the safelight illumination for 1 minute, the safelight is not safe. Next determine which film you can first see fogging - this will indicate he maximum time that is safe for the film to be exposed to the safe-light. If the safelight is not safe, you should do one of the following to correct the problem: 1. Replace the bulb with one of lower wattage 2. Raise the safelight lamp higher from working surface 3. Check the filter - may be cracked or broken In short, the film should be exposed to safelight illumination for the shortest possible period WHITE LIGHT Fluorescent lights should not be used as overhead lights in the darkroom because there is often a short afterglow that may fog the first few films opened after the light has been turned off. c) PROCESSING TANKS Tank processing is the simplest and most efficient procedure for developing, rinsing, fixing and washing films with accurate temperature control. The fresh water tank plays an important role: i) in temperature control ii) In eliminating the alkali (Na2 CO3 ) from the developer and the acid (acetic) from the fixer solution The processing tank contains two parts: The master tank and the insert tanks. 1. MASTER TANK: This tank serves as a water jacket to hold the insert tanks and is usually large enough to provide space between insert tanks for rinsing and washing of films. The water assists in maintaining the same / constant temperature in the insert tanks. 2. INSERT TANKS These are removable containers for the individual processing solutions - (developer and fixer), and are spaced in the master tank

4 The master tanks are made of either enamel, stainless steel or plastic. Never use reactive metals containing tin, copper, zinc, aluminum or galvanized iron. The removable inserts of the tanks should ideally be made of stainless steel in order to accommodate more rapidly to changes in temperature of the water in the master tank. Also, stainless steel is more easily cleaned. These tanks should be supplied with covers. The lid should have a large lip to reduce exposure to light and to reduce exposure to air (oxygen). Cover the developer and fixer tanks when not in use to keep out dirt and to reduce the rate of evaporation and oxidation. d) HOT AND COLD RUNNING WATER X-ray processing solutions are most effective when used with a comparatively narrow range of temperatures. Below 60 degree F, some of the chemicals are sluggish in action, which causes underdevelopment and inadequate fixation. Above a temperature of 75 degree F they work too rapidly and may cause fogging of the film. A temperature of 68 degree F (20 degree C) for 5 minutes is recommended for these reasons: a) The optimum quality of radiographs are attained at this temperature. The contrast and density of the film are most satisfactory and fog is kept to an acceptable low level. b) The processing time is practical i.e. 5 minutes c) With modern solution-tempering devices, a temperature of 68 degree F - 20 degree C is usually conveniently maintained. The temperature of the water in the water tank is controlled by a thermostatic or manual mixing valve in the water supply. (This is why hot and cold running water is essential). The temperature of the water in the master tank in turn controls the temperature of the solutions in the insert tanks e) THERMOMETER AND INTERVAL TIMER i) A thermometer is an indispensable processing-room accessory - a tank thermometer that is plainly marked with both Centigrade and Fahrenheit scales, and has a steel clip that forms a hook to hang the thermometer in the tank (or a floating type) ii) An interval timer is also important in order to control time of development and fixation. f) if development and drying are done in the same room it is recommended that some means of ventilation be provided to supply the room with fresh air as well as eliminating the heated air from the dryer. Suitable drying racks should be present where no automatic dryer is present g) STORAGE PLACE for chemicals and films is essential. Processing rooms cannot be used as storage rooms or for any other procedure in the dental office that will contaminate the films with dust or fumes. However, the darkroom should not be a general store room h) A radiographic viewer is used in the darkroom when making use of the

5 techniques of time temperature or wet viewing and to examine the final product PREPARING PROCESSING SOLUTIONS Developer and fixer chemicals come in powder form, as ready-mixed solutions, or in liquid concentrates. Powdered chemicals must be mixed thoroughly to ensure that the crystals are dissolved. Powdered chemicals are not often used these days. Mixed solutions stored for later use must be kept in tightly stoppered brown bottles. Liquid concentrates are convenient for most offices; they are usually of good strength, occupy little storage space, and are quickly mixed with water. Today most offices use ready mixed chemicals UNDER - AND OVER DEVELOPMENT Underdevelopment will produce light density radiographs and under fixing will produce cloudy, partially opaque radiographs. Greatly prolonged over development will produce chemically fogged radiographs and greatly prolonged underdevelopment will produce light density radiographs. Some radiographs tend to judge the development of a film by sight. This is not a good procedure. since consistently good quality radiographs cannot be produced in this manner. However, sight - development is useful when a film is known to be accidentally overexposed and a reduced developing time is needed to obtain a usable density radiograph and avoid repeated x-ray exposure of the patient CLEANING PROCESSING TANKS The action between the mineral salts in the water and carbonate in the developing solutions produces a deposit on the inside wall of the processing tanks. A commercially prepared stainless steel tank cleaner can be used to remove these deposits. After using the tank cleaner, rinse with fresh water and wipe sides dry with clean cloth. Don't use abrasives such as "kitchen cleaners" - these react unfavorably with the developing solution. Or simply brush thoroughly with a brush and water. ADVANTAGES OF TWO EMULSION LAYERS (DOUBLE COATED EMULSION) Increase in Sensitivity Since there is an emulsion on both sides of the film base, there is an image formed on both sides of the base, each emulsion being exposed simultaneously with the other. These two images are seen as a single image. The two sides together consequently form an image which has twice the silver deposit obtained if a single-sided material were used. This enables much shorter exposures to be used, with less risk of blurring from the movement of parts being radiographed, and with markedly less radiation dose to the patient. When changing from a packet with one film to one with 2 films, the exposure time remains the same and thus the amount of radiation that the patient receives is the same.