High voltage amplifiers: how fast are they really? Falco Systems application note, version 2.0,

Similar documents
USER MANUAL. DC - 5MHz High Voltage Amplifier WMA V to +100V output. DC to -3dB large signal bandwidth. 1300V/µs slew rate typical

USER. manual. Falco Systems WMA-100. High Voltage Amplifier DC - 500kHz

USER MANUAL. Ultra-Low Noise High Voltage Amplifier WMA V to +150V output. 300µV rms output noise. 2mV output offset voltage

High voltage amplifiers and the ubiquitous 50 Ohm: Caveats and benefits. Falco Systems application note, version 1.0,

Tabor Electronics Signal Amplifiers. Quick Start Guide

PHYS 536 The Golden Rules of Op Amps. Characteristics of an Ideal Op Amp

USER MANUAL. DC 13kHz High Voltage Amplifier WMA V to +175V output. Stable with all capacitive loads, generates no overshoot

Operational Amplifiers

When you have completed this exercise, you will be able to relate the gain and bandwidth of an op amp

High Speed BUFFER AMPLIFIER

DEPARTMENT OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCE MASSACHUSETTS INSTITUTE OF TECHNOLOGY CAMBRIDGE, MASSACHUSETTS 02139

ELC224 Final Review (12/10/2009) Name:

UNIVERSITY OF NORTH CAROLINA AT CHARLOTTE Department of Electrical and Computer Engineering

Testing Power Sources for Stability

Operational Amplifiers

DEPARTMENT OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCE MASSACHUSETTS INSTITUTE OF TECHNOLOGY CAMBRIDGE, MASSACHUSETTS 02139

ECEN 325 Lab 5: Operational Amplifiers Part III

EE 368 Electronics Lab. Experiment 10 Operational Amplifier Applications (2)

Electronics I. laboratory measurement guide

Memo. 1 Summary. 1.1 Introduction. 1.2 Experiments. 1.3 Conclusion

EE 3305 Lab I Revised July 18, 2003

Lab 9: Operational amplifiers II (version 1.5)

Op-Amp Simulation Part II

1) Consider the circuit shown in figure below. Compute the output waveform for an input of 5kHz

Measurement and Analysis for Switchmode Power Design

Field Effect Transistors

ULTRA HIGH VOLTAGE DUAL OPERATIONAL AMPLIFIER

Preliminary simulation study of the front-end electronics for the central detector PMTs

LINEAR MODELING OF A SELF-OSCILLATING PWM CONTROL LOOP

HA MHz, High Slew Rate, High Output Current Buffer. Description. Features. Applications. Ordering Information. Pinouts.

EE4902 C Lab 7

LM6118/LM6218 Fast Settling Dual Operational Amplifiers

OPERATIONAL AMPLIFIER PREPARED BY, PROF. CHIRAG H. RAVAL ASSISTANT PROFESSOR NIRMA UNIVRSITY

PowerAmp Design. PowerAmp Design PAD117A RAIL TO RAIL OPERATIONAL AMPLIFIER

Rigol DG1022A Function / Arbitrary Waveform Generator

Electronics II. 3. measurement : Tuned circuits

CLC440 High Speed, Low Power, Voltage Feedback Op Amp

University Tunku Abdul Rahman LABORATORY REPORT 1

6500V/µs, Wideband, High-Output-Current, Single- Ended-to-Differential Line Drivers with Enable

Operational Amplifier

PowerAmp Design. PowerAmp Design PAD112 HIGH VOLTAGE OPERATIONAL AMPLIFIER

Experiment 1: Instrument Familiarization (8/28/06)

HA-2600, HA Features. 12MHz, High Input Impedance Operational Amplifiers. Applications. Pinouts. Ordering Information

Lauren Gresko, Elliott Williams, Elaine McVay Final Project Proposal 9. April Analog Synthesizer. Motivation

Experiment 1: Amplifier Characterization Spring 2019

NOT RECOMMENDED FOR NEW DESIGNS

Basic Communication Laboratory Manual. Shimshon Levy&Harael Mualem

tyuiopasdfghjklzxcvbnmqwertyuiopas dfghjklzxcvbnmqwertyuiopasdfghjklzx cvbnmqwertyuiopasdfghjklzxcvbnmq

Assignment 11. 1) Using the LM741 op-amp IC a circuit is designed as shown, then find the output waveform for an input of 5kHz

PowerAmp Design. PowerAmp Design PAD20 COMPACT HIGH VOLTAGE OP AMP

Opamp Based Power Amplifier

P a g e 1 ST985. TDR Cable Analyzer Instruction Manual. Analog Arts Inc.

PA92. High Voltage Power Operational Amplifiers PA92

University of Jordan School of Engineering Electrical Engineering Department. EE 219 Electrical Circuits Lab

ECE 2274 Lab 2. Your calculator will have a setting that will automatically generate the correct format.

Probing Techniques for Signal Performance Measurements in High Data Rate Testing

EE3204 D2015 HW Set 3

Experiment 1: Instrument Familiarization

1. High Frequency Performance

ECE4902 C Lab 7

EC202- ELECTRONIC CIRCUITS II Unit- I -FEEEDBACK AMPLIFIER

LM7171 Very High Speed, High Output Current, Voltage Feedback Amplifier

OPERATIONAL AMPLIFIERS (OP-AMPS) II

University of Michigan EECS 311: Electronic Circuits Fall 2009 LAB 2 NON IDEAL OPAMPS

Improving CDM Measurements With Frequency Domain Specifications

RCTrms Technical Notes

Instantaneous Loop. Ideal Phase Locked Loop. Gain ICs

CHARACTERIZATION OF OP-AMP

OPERATIONAL AMPLIFIERS and FEEDBACK

UNIT I LINEAR WAVESHAPING

ECE3204 D2015 Lab 1. See suggested breadboard configuration on following page!

Transmit filter designs for ADSL modems

Capacitive Touch Sensing Tone Generator. Corey Cleveland and Eric Ponce

EE 233 Circuit Theory Lab 2: Amplifiers

Single Supply, Rail to Rail Low Power FET-Input Op Amp AD820

250mA HIGH-SPEED BUFFER

HV739 ±100V 3.0A Ultrasound Pulser Demo Board

Using the isppac-powr1208 MOSFET Driver Outputs

ME 365 EXPERIMENT 7 SIGNAL CONDITIONING AND LOADING

Homework Assignment 06

Model MHz Arbitrary Waveform Generator Specifications

Audio Power Amplifiers with Feedback Linearization

Spectrum analyzer for frequency bands of 8-12, and MHz

Background (What Do Line and Load Transients Tell Us about a Power Supply?)

Operational Amplifiers

High Voltage Power Operational Amplifiers EQUIVALENT SCHEMATIC R1 R2 C1 R3 Q6 4 CC1 5 CC2 Q8 Q12 3 I Q Q16. +V s

EQUIVALENT CIRCUIT DIAGRAM

Transmit filter designs for ADSL modems

Electronic Buzzer for Blind

INDIANA UNIVERSITY, DEPT. OF PHYSICS, P400/540 LABORATORY FALL Laboratory #6: Operational Amplifiers

Concepts to be Reviewed

LM565/LM565C Phase Locked Loop

Cost-Effective Traceability for Oscilloscope Calibration. Author: Peter B. Crisp Head of Metrology Fluke Precision Instruments, Norwich, UK

Op Amp Booster Designs

Experiment 8 Frequency Response

Methods for Reducing Emissions from Switching Power Circuits. A. McDowell, C. Zhu and T. Hubing

Introduction (cont )

When you have completed this exercise, you will be able to determine the frequency response of an

GATE: Electronics MCQs (Practice Test 1 of 13)

UNIT 2. Q.1) Describe the functioning of standard signal generator. Ans. Electronic Measurements & Instrumentation

Transcription:

Application note High voltage amplifiers: how fast are they really? Falco Systems application note, version., www.falco-systems.com W. Merlijn van Spengen, PhD March 1 The high speed, high voltage amplifier: performance criteria High voltage amplifier high speed performance is not only determined by the bandwidth and the slew rate, but also by the maximum sustainable output current of the amplifier and the capacitance of the load. This article discusses the specifications of high voltage amplifiers required to determine whether they are suitable for a certain amplifier-load combination. A corresponding output current calculator can be used to estimate the current and slew rate required to drive a certain capacitive load. It is available at http://www.falco-systems.com/high_voltage_amplifier_current_calculator.php. The bandwidth The basic specifications describing the speed of a linear high voltage amplifier such as the Falco Systems WMA-3 are its large signal bandwidth, small signal bandwidth and slew rate. The large signal bandwidth shows what the output amplitude voltage of a high voltage amplifier is for a given input sine wave amplitude as a function of frequency that drives it to its maximum output voltage (Fig. 1). Because the output voltage of the high voltage amplifier falls off gradually above a certain transition frequency, a single magic number named the bandwidth being so-and-so many khz is only useful if also the reduction of the full-power bandwidth of the high voltage amplifier at this frequency is also quoted. It is often expressed as the -3dB point, where the amplitude has fallen to.77 times the maximum amplitude at low frequencies, but this is not always the way it is specified, so one has to be careful with a single number. A graph showing the maximum output voltage versus frequency conveys much more information. The small-signal bandwidth (sometimes, confusingly, also called the bandwidth ) is the frequency response of the high voltage amplifier at some very low output voltage like 1% of the maximum output. This bandwidth is usually larger than the large signal bandwidth by a significant amount. Large signal amplitude (normailized) 1...... Large signal Small signal 1 1 1 1 1 3 1 1 5 1 15 1 5 Small signal amplitude (1%) 1 3 Frequency (Hz) Figure 1. The large signal and small signal bandwidth of a high voltage amplifier can differ significantly

The step response and the slew rate The step response is the time an amplifier needs to go from 1% to 9% of the total output voltage in response to a step in voltage at the input (Fig. ). The corresponding slew rate of a high voltage amplifier is a fairly subtle spec. It is the fastest voltage change that the output can make, and as such it is the slope of the fastest part of the curve in Fig. It is given in V/µs, the number of volts that the output can rise (or fall) in one microsecond, if it could continue to rise for one microsecond. This spec obviously limits the capability of an amplifier to generate high voltage pulses with sharp rising and falling edges (Fig. 3), but is also a bandwidth limiting factor for sine-wave or arbitrary signals. This can be seen as follows. The highest rate of change in the output voltage of a sine wave is at the Vcrossing (Fig. ). The higher the frequency, the faster the voltage has to rise there to prevent distortion of the sine wave. If the high voltage amplifier cannot follow due to its limited slew rate, the sine wave will be distorted to a triangle, and its amplitude is lower than at low frequencies. The maximum peak to peak sine wave output voltage Vpp is related to the slew rate S by Vpp = S/πf, where f is the frequency of the sine wave. Note that this is at full amplitude, not at -3dB. 3.µs.µs 1 9% Output voltage (V) Output voltage 1% Time (µs) Figure. The step response of a high voltage amplifier is the time required to change the output from 1% to 9% amplitude. In this example the slew rate (the fastest rise of the curve) can be conservatively estimated to be V/.µs = 9V/µs based on the step response. In fact, the slew rate is a little higher than calculated, as the fastest rise (in the middle) is higher than that of the full 1 9% transition. High slew rate Lower slew rate Insufficiently low slew rate Figure 3. Depending on the slew rate of the amplifier, a set of pulses can either be amplified undistorted or severely affected.

Normalized output voltage 1..5. -.5 If the slew rate is less than the steepest part of the sine wave, the output voltage will be distorted. Output voltage -1. Time (µs) Figure. If the slew rate of the amplifier is not sufficient sine waves are distorted as well. The higher the frequency and the amplitude of the waveform, the more important is the slew rate of the high voltage amplifier. Slew rate versus current capacitive loading The discussion above assumed that the load at the output of the high voltage amplifier does not influence the behavior of the amplifier in any way. This is the case for very small capacitive or resistive loads. However, typical loads for a high voltage amplifier are highly capacitive, like PZT (piezo) transducers, EO (Electro-Optical) modulators, and, to a lesser extent, coaxial cables (a RG5 cable constitutes about 1pF per meter!). To be able to bring the output voltage of the high voltage amplifier to a certain level, this component at the output (representing electronically a capacitor) has to be charged to this voltage (Fig. 5). If the high voltage amplifier has a current limit of IL amperes, it can charge up a capacitor C only with a certain maximum speed. The maximum rise in voltage per microsecond (again a slew rate, but now determined by the maximum current and the load capacitor, so we call it SA) is then SA = IL/C, which can for large capacitance values be significantly lower than the intrinsic slew rate of the amplifier S discussed above. The bandwidth for sine wave signals is reduced correspondingly. Even worse: if the high voltage amplifier has a current limit but will overheat when the maximum current is drawn continuously, it will break down or (preferably) shut down after a while when delivering a high frequency, high voltage output, even though the load at low frequencies is negligible. This is a real problem with amplifiers that have a high peak output current, but a much lower maximum average current specification. Figure 5. A capacitive load at the output of the high voltage amplifier can change its slew rate Instabilities and overshoot due to capacitive loading Many high voltage amplifiers have an internal circuitry that looks like a high voltage version of the general operational amplifier (opamp, Fig. ). A capacitor at the output of such a circuit in combination with the opamp output resistance creates a time lag of the output voltage, because the capacitor has to be charged first as discussed above. This means that the voltage at the ( ) input of the opamp is delayed too, which can cause the signal at the (+) and ( ) input at certain frequencies

to be 1 degrees out of phase rather than in-phase. If this happens with certain capacitance value at frequencies well above the frequency where the opamp has an amplification smaller than 1, this is no problem, but when this happens at a frequency where the opamp is still capable of amplifying the signal, the circuit has been effectively turned into an oscillator. The result is then at least overshoot or ringing at the output, and in extreme cases sporadic or continuous oscillations (Fig. 7). If the capacitor value is chosen large enough, this effect disappears again (although with a dramatically reduced bandwidth as a result). This means that many amplifiers have a certain capacitive load value where they are most likely to generate spurious signals. Only by placing the output stage outside the feedback loop (Fig. ) in a high voltage amplifier design, this effect is circumvented. Figure. Most high voltage amplifiers have an internal structure that is similar to that of an operational amplifier. Certain load capacitance values can cause instability of the amplifier 1. 1..5.5.. -.5 -.5-1. -1. Full oscillation Parasitic oscillations 1. 1. 1. 1. 1. 1........... Ringing Overshoot Figure 7. Amplifier instability manifests itself in various ways on the oscilloscope

Figure. By adding an independent output stage that is not in the feedback loop, the instabilities of a conventional high voltage amplifier at certain capacitive loading conditions are eliminated Example with numbers, using the Falco Systems WMA-3 high speed, high voltage amplifier In the following section, we illustrate the principles discussed above by comparing them to specs of a real high voltage amplifier, the Falco Systems WMA-3 (Fig. 9). It is made for very high speed operation and hence has a very large power bandwidth of DC 5 MHz (-3dB) and a V/µs slew rate. The main application is in MEMS (micro-electromechanical systems) or EO-modulators, where the connecting coax cables are usually the main capacitive load (~1pF), but it is instructive to see what happens when the capacitive load is increased to the values typical for piezo-transducers (~nf). The large signal bandwidth of the WMA-3 with 3Vpp output voltage (the maximum) is given in Fig. 1. The slew rate is measured by monitoring the rise-time of a pulse on an oscilloscope (Fig. 11). The bandwidth and slew rate specs result in a nice 3Vpp 1kHz square wave (Fig.1) with fast rising and falling edges with no load. This waveform is distorted if we add a significant load capacitance (Fig. 13). For 15pF the effect is negligible, but when we drive several nanofarads, the speed is reduced considerably. The reason is the 3mA current limit of the WMA-3 that limits the speed at which the capacitor can be charged, and hence the loaded slew rate SA is smaller for the loaded conditions. Note that there is no capacitive load at which the system generates overshoot. Unlike in many other amplifiers, in the WMA-3 the configuration of Fig. has been used, which effectively prevents any instability caused by the load. Figure 9. A wide bandwidth high voltage amplifier, The Falco Systems WMA-3

3 Output amplitude (Volt) 1 1 3 1 1 5 1 1 7 Frequency (Hz) Figure 1. The large signal bandwidth of the WMA-3 Figure 11. The slew rate of the WMA-3 is obtained by investigating the step response time it takes for a voltage pulse from -15 to +15V to go from 1% to 9% amplitude. On the oscilloscope screen the %, 1%, 9% and 1% marks on the left are used to do the measurement properly. V in 15ns gives a conservative estimate of 19V/µs. Figure 1. An oscilloscope image of an amplified, undistorted 1kHz, 3Vpp square wave with no load at the output of the high voltage amplifier

pf 15pF 1.5 nf.7 nf 15 nf nf Figure 13. Loading the high voltage amplifier with different capacitors at its output limits the slew rate Conclusions To select a high speed high voltage amplifier for a certain purpose, one has to look not only at the bandwidth and/or slew rate of the amplifier, but also at the expected capacitive load, the maximum sustainable output current (as opposed to peak current) and the possibility of instability and overshoot voltages damaging the load. Control over all of these is required for an optimal result.