Data Center & Cloud Computing DATASHEET. 100 GHz DWDM Passive Optical Add/Drop Multiplexers Data Center & Cloud Computing Infrastruture Solutions

Similar documents
DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions. 8 Channels nm Dual Fiber CWDM Mux Demux FMU Plug-in Module, LC/UPC

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions. 4 Channels nm Dual Fiber CWDM Mux Demux FMU Plug-in Module, LC/UPC

Overview. Highlights. General Specification. Datasheet

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions. 16 Channels C27-C42 Dual Fiber DWDM Mux Demux 1U Rack Mount, LC/UPC

DATASHEET FMU-MD08E-A/B, w/expansion Port. Data Center & Cloud Computing Infrastruture Solutions

FMU-MC09-A/B, Pair Packaged DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

DATASHEET FMU-MC04E-A/B, w/expansion Port. Data Center & Cloud Computing Infrastruture Solutions

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

Data Center & Cloud Computing DATASHEET. Dual & Single Fiber DWDM OADM. Data Center & Cloud Computing. Infrastruture Solutions

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

Data Center & Cloud Computing DATASHEET. Dual & Single Fiber DWDM OADM. Data Center & Cloud Computing. Infrastruture Solutions

DATASHEET FMU-MC04E-A/B, Pair Packaged, w/expansion Port

16 Channels C21-C36 Dual Fiber DWDM Mux Demux, w/expansion Port 1U Rack Mount, LC/UPC

DWDM Dual Fiber series

WaveSmart Wave Division Multiplexing (WDM)

GT Channel Ultra Compact CWDM Mux & DeMux

OPCOM100-DAD4D 4-Channel Bidirectional DWDM ADM. Typical Application. Figure.1 Chain Topology. Datasheet. Raisecom Technology Co., Ltd.

XSD Single Fiber series DWDM passive optical components

Dual & Single Fiber Compact CWDM Mux Demux

OPCOM100-DMU40 40-Channel DWDM. Mux/Demux. Typical Application. Figure.1 Point to Point Topology. Datasheet. Raisecom Technology Co., Ltd.

OPC1600 MUX WDM OADM SPLITTER

LEAD Fiber Optics PRODUCT CATALOGUE

On the subsequent pages, you will find the full, parameter-for-parameter comparison. If you have any questions, please contact Fiberdyne Labs.

Datasheet. 40ch DWDM Mux Demux + Monitor Port 1U Rack Mount, LC/UPC. Overview. Highlights

Wave Division Multiplexing. Passive Mux/Demux Modules & Cables. Datasheet. Features. Overview. Typical 2-Channel Passive Mux/Demux Application

Dense Wavelength Division Multiplexer (DWDM) 200 GHz Spacing, Multi-Channel, 2ch, 4ch, 8ch, 16ch, 20ch in PEACOC Flexible Tray

WaveReady Single-Channel DWDM Add/Drop for OSP Splice Enclosure. MDF-01AD10xx0

CWDM Single Fiber series

Optical Passives (ISP)

LEAD Fiber Optics PRODUCT CATALOGUE

Datasheet. FMU-MC04-A/B, Pair Packaged 4 Channels Single Fiber CWDM Mux Demux, Plug-in Module, LC/UPC. Overview. Highlights

Further more all functions as well available in splice trays or splice enclosures (-40 to 85 C)

XM40-QD20LD-J 40-ch Multiplexer/Demultiplexer

CWDM Cisco CWDM wavelengths (nm)

50/100 GHz, 100/200 GHz Passive Interleavers. IBC Series

WDM -Transmission V-1.

WaveReady 40- and 44-Channel Multiplexer/ Demultiplexer with Test Channel. MDX-40MD101CB and MDX-44MD101CB

WaveReady CWDM Add/Drop for OSP Splice Enclosure

Prisma DWDM Passives. Features. Optical Passive Components

M-FP ISOLATOR PIGTAILS

CISCO DWDM GBICS. Figure 1. Cisco DWDM GBICs. Main features of the Cisco DWDM GBICs:

Prisma and Laser Link DWDM Passives for LGX-Compatible Systems

Passive WDM Networking

DWDM Mux/Demux product range

WaveReady Multi-Degree Reconfigurable Optical Add/Drop Multiplexer WRS-05AD1C00B

FUSED COUPLER C OR L BAND

Digital Return System

About KOC Group. Please visit us website for more informations :

Wavelength Selective Switch (WSS) 1x9

Digital Return System

OptiSheath Advantage Sealed Terminal Solution for WDM Applications, UCA4-XX An Evolant Solutions Product

WaveReady 8-Channel DWDM OSP Optical Add/Drop Multiplexer for Splice Enclosures. MDF-08MD1N0xB and MDF-08MD1Z0xB

Odd. Even. Insertion Loss (db)

Headend Optics Platform (CH3000)

/ On the web: / Telephone: IS-FIBER (800)

Cisco Prisma Optical Passive Components

OMxxDyy-100zz-ab:cd-(M5)-XXYY

Optiva RF-Over-Fiber Design Tool User s Guide. Revision 1.0 March 27, 2015

CA92009-O O Band (1260 ~ 1360 nm) Tunable Laser Source

Pass Cisco Exam

100GHz WAVELENGTH DIVISION MULTIPLEXER/ DEMULTIPLEXER (APMUX1100 / APDMX1100)

Optical Passives and Accessories

Optiva OTS-2 40 GHz Amplified Microwave Band Fiber Optic Links

ODN4P. Optical Distribution Node, Four Ports. About the Product

Optiva OTS-2 40 GHz Amplified Microwave Band Fiber Optic Links

MEMS Variable Optical Attenuator (VOA)

GS7000 & GainMaker Reverse Segmentable Node bdr Digital Reverse 2:1 Multiplexing System

WL Photonics Inc. Leading Provider of Fiber Optic Wavelength Tuning and Conditioning Solutions

WL Photonics Inc. Leading Provider of Fiber Optic Wavelength Tuning and Conditioning Solutions

Optiva OTS-2 18 GHz Amplified Microwave Band Fiber Optic Links

FX180 OCA. Platform Highlights. Key Features

Product Bulletin. 2 mw WDM Laser for Direct Modulation in Links up to 100 km CQF915/108 Series

CISCO ONS /100-GHZ INTERLEAVER/DE-INTERLEAVER FOR THE CISCO ONS MULTISERVICE TRANSPORT PLATFORM

Artisan Scientific is You~ Source for: Quality New and Certified-Used/Pre:-awned ECJuiflment

Optiva 18 GHz Unamplified Microwave (MW) Transport System

Cisco ONS Metropolitan Dense Wavelength Division Multiplexing 100-GHz FlexLayer Filter Solution

Table of Contents INTERCONNECTS / CABLE ASSEMBLIES / PATCH PANELS

CWDM. DATA SHEET DB4133-E Issue L Page 1 of 8

Prisma II Multi-Wavelength High Density Transmitter

Prisma II 1310 nm High Density Transmitter and Host Module

from ocean to cloud SEAMLESS OADM FUNCTIONALITY FOR SUBMARINE BU

GS7000 and GainMaker Reverse Segmentable Node bdr Digital Reverse 2:1 Multiplexing System

Prisma II 1310 nm High Density Transmitter and Host Module

Opti Max Optical Node Series

Features. Applications. Package Dimensions

BDA Broadband Drop Amplifier

Xeston Technologies. XESTON 1550nm DWDM CW DFB Laser With PM Fiber. XQF935 Series Specification Datasheet (Preliminary)

Cisco s CLEC Networkers Power Session

Exam : : Cisco Optical SONET Exam. Title. Ver :

2.5 Gb/s Buried Het 4x100GHz Tunable Laser with Etalon Stabilisation and extended reach option LC25ET

Attenuators are available as - in-line types - plug types

SERIES DL221 10/100 ETHERNET TRANSCEIVER USER MANUAL

X5 and Z5 Modulator. Telcordia 468. Key Features. Applications. Compliance AGILE OPTICAL COMPONENTS NORTH AMERICA: JDSU (5378)

Module 19 : WDM Components

User Manual. Portable C-band 26dB-gain EDFA Instrument in compact benchtop. (EDFA-C-26G-S, version 1.0b. January 28, 2015) Fiberprime, Inc.

Standard/Compact Tap Photo Detector

Transcription:

Data Center & Cloud Computing DATASHEET 100 GHz DWDM Passive Optical Add/Drop Multiplexers Data Center & Cloud Computing Infrastruture Solutions REV.1.0 2017

100 GHz DWDM Passive Optical Add/Drop Multiplexers 01 Overview DWDM Optical Add/Drop multiplexer (OADM) is a passive optical device used in WDM networks for adding and dropping one/multiple 100 GHz DWDM channels in the C-band into one or two fibers, while letting the rest of the wavelengths bypass to the needed destination. Using the DWDM technology can add effctively WDM capability to their existing and new networks, and extend the optical signals transmission distance. DWDM OADM modules are available in single-sided (East or West) and dualsided (East and West) configurations. With matching MUX/DeMUX units placed at each end of an optical link, multiple data channels can be combined and transmitted over a single-mode fiber trunk. The passive OADM modules can add or drop up to 4 data channels at any point along the trunk. DWDM OADM are modular, scalable and are perfectly suited to 10/1G Ethernet, 16/8/4/2/1G FC, SDH/SONET, Video, CATV, FTTx applications. Key Features Low insertion loss for C-band channels Add/drop up to 4 channels at remote sites Protocol transparent (support 1G, 10G etc.) Based on thin film optics with epoxy free optical path Fully compliant with Telcordia GR1221, GR1209, RoHS, ISO Plug-in module for integration in a standalone or 2-slot 1U 19 rack mount Completely passive, no power or maintenance required Ideal for DWDM ring structures or daisy chain applications Benefits Improves capacity exhaust in fiber-constrained situations Conserves or reclaims fiber with DWDM Lowest cost solution on the market Highly flexible and scalable

02 100 GHz DWDM Passive Optical Add/Drop Multiplexers 02 Product Specifications Parameter Channel Spacing Channel Passband Value 100GHz(0.8nm) ITU±0.11nm Filter Technology Add &Drop Adjacent Channel Isolation Add &Drop Non-adjacent Channel Isolation Return Loss PDL PMD Power Handling TFF (Thin Film Filter) 25 db 40 db > 45 db < 0.1 db < 0.1 ps 500 mw Connectors LC/UPC Operating Temperature -5 ~ +75 Storage Temperature -40 ~ +85 Dimension (W x H x D) Compliance Craftsmanship Fitting Chassis 212mm x 44mm x 267.3mm ITU-T G.694.2, Telcordia GR1221, GR1209, RoHS, ISO SPCC construction, black powder coating finish FMU-1UFMX-N 2-slot 1U 19'' Chassis

100 GHz DWDM Passive Optical Add/Drop Multiplexers 03 General Specification Front View Logical Diagram Optical Specification 1 Dual Fiber West and East FMU-MDA0121 Wavelength: LINE E Add/Drop Insertion Loss: <1.2 db 1DADMSF Bypass Insertion Loss: <1.3 db FMU-MDA022122 1DAD 2DADMSF MDF LINE E Wavelength:, Add/Drop Insertion Loss: <1.5 db Bypass Insertion Loss: <1.7 db FMU-MDA042124 Wavelength:,, C23, C24 C23 C24 C23 C24 2DAD 4DADMSF MDF LINE E C 23 C 22 C2 1 C 24 C 26 C 25 C 28 C 27 Add/Drop Insertion Loss: <2.2 db Bypass Insertion Loss: <2.5 db Single Fiber West and East 4DAD MDF FMU-MDAS0121 Wavelength:, Add/Drop Insertion Loss: <1.5 db 1DADMSF LINE E Bypass Insertion Loss: <1.4 db FMU-MDAS022124 1DAD MSF Wavelength:,, C23, C24 C23 C24 Add/Drop Insertion Loss: <2.4 db R 2DADMSF X LINE E C23 C24 C24 C23 Bypass Insertion Loss: <2.6 db

100 GHz DWDM Passive Optical Add/Drop Multiplexers 04 Layout and Dimensions FMU-1UFMX-N is a standard 1U 19'' rack mount which provides simple installation for plug-in modules and the chassis can accommodate up to two plug-in modules. It may be mounted (forward or backward) into 19'' or 23'' racks. 437.8mm FMU-1UFMX-N chassis 44mm 261.2mm 181mm 481.8±0.2mm 267.3mm 44mm FMU-1U-N module 212mm Customized Services Wavelengths Fiber Type -C60 in C-Band,100GHz, 0.8nm spacing Dual fiber, Single fiber Connectors Housing LC/UPC, LC/APC,SC/UPC, SC/APC FC/UPC, FC/APC, ST/UPC, ST/APC FMU plug-in module, 1U 19'' rack mount FUD module, Splice/pigtailed ABS module Special Service 1310nm Port, Monitor Port Note: If you need even more customization welcome to contact sales@fs.com.

.COM business radiate worldwide, if you need more efficient solutions for Data Center, Optical Transport Network, and Enterprise Network, please contact us at sales@fs.com For more information visit www.fs.com.com DATA CENTER & CLOUD COMPUTING All statements, technical information, and recommendations related to the products here are based upon information believed to be reliable or accurate. However, the accuracy or completeness thereof is not guaranteed, and no responsibility is assumed for any inaccuracies. Please contact for more information. Copyright 2009-2017.COM All Rights Reserved.