Author(s) Issue Date Text Version author. DOI / /18/9/095501

Similar documents
Tip-induced band bending and its effect on local barrier height measurement studied by light-modulated scanning tunneling spectroscopy

Circular Dichroism Microscopy Free from Commingling Linear Dichroism via Discretely Modulated Circular Polarization

Akiyama-Probe (A-Probe) guide

Fabrication of a submicron patterned using an electrospun single fiber as mask. Author(s)Ishii, Yuya; Sakai, Heisuke; Murata,

- Near Field Scanning Optical Microscopy - Electrostatic Force Microscopy - Magnetic Force Microscopy

Akiyama-Probe (A-Probe) guide

Study of shear force as a distance regulation mechanism for scanning near-field optical microscopy

Prepare Sample 3.1. Place Sample in Stage. Replace Probe (optional) Align Laser 3.2. Probe Approach 3.3. Optimize Feedback 3.4. Scan Sample 3.

XYZ Stage. Surface Profile Image. Generator. Servo System. Driving Signal. Scanning Data. Contact Signal. Probe. Workpiece.

Multi-Probe Atomic Force Microscopy Using Piezo-Resistive Cantilevers and Interaction between Probes

Keysight Technologies Using Non-Contact AFM to Image Liquid Topographies. Application Note

A scanning tunneling microscopy based potentiometry technique and its application to the local sensing of the spin Hall effect

Distinguishing Between Mechanical and Electrostatic. Interaction in Single-Pass Multifrequency Electrostatic Force

Atomic Force Microscopy (Bruker MultiMode Nanoscope IIIA)

Nanovie. Scanning Tunnelling Microscope

Advanced Nanoscale Metrology with AFM

A Project Report Submitted to the Faculty of the Graduate School of the University of Minnesota By

Basic methods in imaging of micro and nano structures with atomic force microscopy (AFM)

MEMS for RF, Micro Optics and Scanning Probe Nanotechnology Applications

Comparison of resolution specifications for micro- and nanometer measurement techniques

Instructions for easyscan Atomic Force Microscope

Akiyama-Probe (A-Probe) technical guide This technical guide presents: how to make a proper setup for operation of Akiyama-Probe.

PH880 Topics in Physics

Scanning Tunneling Microscopy

Logic circuits based on carbon nanotubes

Self-navigation of STM tip toward a micron sized sample

Phase modulation atomic force microscope with true atomic resolution

Uncertainty in measurements of micro-patterned thin film thickness using Nanometrological AFM - Reliability of parameters for base straight line -

SUPPLEMENTARY INFORMATION

Investigate in magnetic micro and nano structures by Magnetic Force Microscopy (MFM)

SUPPLEMENTARY INFORMATION

Visible light emission and metal-semiconductor transition in single walled carbon nanotube composites T. Pradeep Department of Chemistry and

Supporting Information

Supporting Information

Elimination of bistability in constant-phase mode in atomic force microscopy

photolithographic techniques (1). Molybdenum electrodes (50 nm thick) are deposited by

Analysis of the process of anodization with AFM

Outline: Introduction: What is SPM, history STM AFM Image treatment Advanced SPM techniques Applications in semiconductor research and industry

Physics Faculty Publications and Presentations

III III 0 IIOI DID IIO 1101 I II 0II II 100 III IID II DI II

Observation of Remanent Vortices Attached to Rough Boundaries in Superfluid 4 He

attosnom I: Topography and Force Images NANOSCOPY APPLICATION NOTE M06 RELATED PRODUCTS G

Optical Microscope. Active anti-vibration table. Mechanical Head. Computer and Software. Acoustic/Electrical Shield Enclosure

Infrared Perfect Absorbers Fabricated by Colloidal Mask Etching of Al-Al 2 O 3 -Al Trilayers

UNIVERSITY OF WATERLOO Physics 360/460 Experiment #2 ATOMIC FORCE MICROSCOPY

CONSTRUCTING A SCANNING TUNNELING MICROSCOPE FOR THE STUDY OF SUPERCONDUCTIVITY

Microscopic Basis for the Mechanism of Carrier Dynamics in an Operating p-n Junction Examined by using Light-Modulated Scanning Tunneling Spectroscopy

Park NX-Hivac: Phase-lock Loop for Frequency Modulation Non-Contact AFM

Mode analysis of Oxide-Confined VCSELs using near-far field approaches

Defense Technical Information Center Compilation Part Notice

Imaging Carbon Nanotubes Magdalena Preciado López, David Zahora, Monica Plisch

Indentation Cantilevers

Electrical transport properties in self-assembled erbium. disilicide nanowires

arxiv:cond-mat/ v1 [cond-mat.mtrl-sci] 30 Jun 1999

Nanoscale Material Characterization with Differential Interferometric Atomic Force Microscopy

RHK Technology. Application Note: Kelvin Probe Force Microscopy with the RHK R9. ω mod allows to fully nullify any contact potential difference

Unit-25 Scanning Tunneling Microscope (STM)

Edinburgh Research Explorer

Conductance switching in Ag 2 S devices fabricated by sulphurization

Controller Design for Z Axis Movement of STM Using SPM Control Software

ATOMIC FORCE MICROSCOPY

Electric polarization properties of single bacteria measured with electrostatic force microscopy

Nanodrawing of Aligned Single Carbon. Nanotubes with a Nanopen

Standard Operating Procedure

Project Staff: Feng Zhang, Prof. Jianfeng Dai (Lanzhou Univ. of Tech.), Prof. Todd Hasting (Univ. Kentucky), Prof. Henry I. Smith

Figure for the aim4np Report

Measurement of Microscopic Three-dimensional Profiles with High Accuracy and Simple Operation

INDIAN INSTITUTE OF TECHNOLOGY BOMBAY

SUPPLEMENTARY INFORMATION

Fabrication and Device Simulation of Single Nano-Scale Organic Static Induction Transistors

Fine structure of the inner electric field in semiconductor laser diodes studied by EFM.

Scanning Tunneling Microscopy

Surface Finish Measurement Methods and Instrumentation

Measuring CNT FETs and CNT SETs Using the Agilent B1500A

; A=4π(2m) 1/2 /h. exp (Fowler Nordheim Eq.) 2 const

Piezoelectric Potential Gated Field-Effect Transistor Based on a Free-Standing ZnO Wire

Supplementary Information: Nanoscale. Structure, Dynamics, and Aging Behavior of. Metallic Glass Thin Films

BRIDGE VOLTAGE SOURCE

Supplementary Information

Supplementary Information. The origin of discrete current fluctuations in a fresh single molecule junction

Lecture 20: Optical Tools for MEMS Imaging

Using Nanoelectrical Solutions to expand the capability of AFM Dr. Peter De Wolf

3D simulations of the experimental signal measured in near-field optical microscopy

SENSOR+TEST Conference SENSOR 2009 Proceedings II

Alejandro Mendez, Ph.D. President & CEO Mendezized Metals Corporation

Radio-frequency scanning tunneling microscopy

Author(s) Osamu; Nakamura, Tatsuya; Katagiri,

Journal of Advanced Mechanical Design, Systems, and Manufacturing

Precision machining and measurement of micro aspheric molds

State of the Art Room Temperature Scanning Hall Probe Microscopy using High Performance micro-hall Probes

A Brief Introduction to Single Electron Transistors. December 18, 2011

Nanosurf easyscan 2 FlexAFM

Supplementary Figure 1 Schematic illustration of fabrication procedure of MoS2/h- BN/graphene heterostructures. a, c d Supplementary Figure 2

Profile Measurement of Resist Surface Using Multi-Array-Probe System

SUPPLEMENTARY INFORMATION

Nanonics Systems are the Only SPMs that Allow for On-line Integration with Standard MicroRaman Geometries

Piezoelectric Potential Gated Field-Effect Transistor Based on a Free-Standing ZnO Wire

Influence of surface acoustic waves on lateral forces in scanning force microscopies

Electrical Properties of Chicken Herpes Virus Based on Impedance Analysis using Atomic Force Microscopy

Manufacturing Metrology Team

Transcription:

Title Author(s) Citation Refinement of Conditions of Point-Contact Current Imaging Atomic Force Microscopy for Molecular-Scale Conduction Measurements Yajima, Takashi; Tanaka, Hirofumi; Matsumoto, Takuya; Otsuka, Yoichi; Sugawara, Yoshitaka; Ogawa, Takuji Nanotechnology. 18(9) P.1-P.5 Issue Date 2007-03 Text Version author URL http://hdl.handle.net/11094/3342 DOI 10.1088/0957-4484/18/9/095501 rights Copyright: Institute of Physics

Refinement of Conditions of Point-Contact Current Imaging Atomic Force Microscopy for Molecular-Scale Conduction Measurements Takashi Yajima, 1,2, Hirofumi Tanaka, 1,2,4,*, Takuya Matsumoto, 3,4 Yoichi Otsuka, 3, Yoshitaka Sugawara 1 and Takuji Ogawa 1,2,4 1 Research Center for Molecular-Scale Nanoscience, Institute for Molecular Science, 5-1 Higashiyama, Myodaiji, Okazaki, Aichi 444-8787, Japan. 2 Graduate University for Advanced Study (Sokendai), 5-1 Higashiyama, Myodaiji, Okazaki, Aichi 444-8787, Japan. 3 Institute for Scientific and Industrial Research, Osaka University, 8-1 Mihogaoka, Ibaraki, Osaka 567-0047, Japan. 4 CREST, Japanese Agency of Science and Technology (JST), 4-1-8, Honcho, Kawaguchi, Saitama 332-0012, Japan. *Corresponding author: htanaka@ims.ac.jp Present Address: Canon Research Center, Canon Inc., 3-30-2, Shimomaruko, Ohta, Tokyo 146-8501, Japan. 1

ABSTRACT We have refined the measurement conditions of point-contact current imaging microscopy (PCI-AFM) to measure the electric properties along the long axes of one-dimensional structures. Using this refinement, the current image of the PCI-AFM can be used to distinguish individual single-walled carbon nanotubes in a bundled structure. The PCI-AFM will thus help further developments in nanoscience for conduction measurements in one-dimensional structures. 2

1. Introduction Although there are several methods to measure conductivity on the nanoscale, each of these methods has its own weak points for measurements along the long axis of one dimensional (1D) nanostructures. Using a nanogap electrode fabricated by several different methods, for example electron beam lithography, 1) break junctions, 2) electrochemical growth, 3) electromigration, 4) it was difficult to confirm that nanoscale objects (<10 nm) within the gap actually made stable contact with the electrodes. Using scanning tunneling microscopy (STM), current can be measured through a sample sandwiched between a scanning tip and a conductive substrate with a certain gap size. In order to measure the conductivity along the long axis of a 1D structure by STM, however, the sample needs to be placed vertically on the substrate, perpendicular to the substrate surface. If not, the current passes through the diameter between the STM tip and the substrate. Contact mode atomic force microscopy is the most frequently used method to measure the conductivity of the long axis of 1D structures shown in Fig. 1(a). However, the method also has a disadvantage in that if the sample has weak or there is no interaction with the substrate, the sample can be moved by the scanned cantilever during measurements similar to the one shown in Fig. 1(b). In order to overcome the disadvantages described above, point contact current imaging 3

atomic force microscopy (PCI-AFM), which utilizes the precision of an atomic force probe to measure current-voltage (I-V) characteristics at specific points on a nanosystem, was developed to investigate variations in transport characteristics of 1D structures. During our development of the PCI-AFM, the conduction properties of single-walled carbon nanotubes (SWCNT), 5,6) the electric properties of porphyrin aggregation working as a nanodevice on a wired SWCNT, 7,8) DNA 9) etc. were measured along their long axes. These results proved that the PCI-AFM is a powerful technique for electrical measurements in 1D nanostructures. However, PCI-AFM also has a problem in that if the measurement conditions are slightly different from the most optimal conditions, not all of the measurements will be successful. In the present paper, we report a method for determining reproducible and optimized conditions for PCI-AFM measurements. By refining the optimized conditions, the PCI-AFM current images allow for distinguishing individual SWCNTs in a bundled structure. 2. Experimental Method The PCI-AFM measurements were conducted using the Scanning Probe Microscope (JEOL JSPM-4210) expanded with two function generators (FG) (WF1946, NF Corporation). Pt-coated conductive cantilevers were used to measure the current. The 4

force constant and resonant frequency of the cantilevers were 4.5 N/m and approximately 150 khz, respectively. This measurement was performed in a nitrogen-gas-purged atmosphere to avoid humidity. When I-V measurements were carried out, the force between the cantilever and the sample was approximately 13 nn, calculated using a force curve. 6) A bias voltage was applied to the gold electrode on the substrate and the cantilever was grounded. Each signal was stored using a storage Oscilloscope (Lecroy WaveRunner 6030). The procedure used for the PCI-AFM method is shown in Fig.2, and a timing chart of conventional conditions for the procedure is shown in Fig. 3(a). Feedback is controlled by a transistor logic (TTL) signal. When the signal is in zone A in Fig. 3(a), feedback is active and the cantilever is oscillated at a resonant frequency for tapping-mode scanning. In this zone, the z-servo voltage is stored in the memory of the computer to form a topographic image. When the cantilever tip is displaced to the preset positions for I V measurements by changing the bias for the piezo-actuator to change the height of the cantilever from the sample surface (Z-control), the lateral scan is interrupted and the feedback control signal is set to low. This high-to-low transition of the Z-control provides a trigger signal to start measurement of I-V characteristics in zone B. In this zone, the feedback system is deactivated, the cantilever excitation is stopped, and the 5

tip-sample separation is set so that the tip and the sample come into contact under a specific loading force. Stopping the excitation enables the tip to contact the sample statically. The applied bias voltage is then ramped and I-V characteristics are stored in the computer. Finally, the tip-sample separation is reset to the previous value, the feedback system is reactivated, and tapping mode scan is restarted. These alternate operations are performed continuously, and both the topographical data and the I-V data are simultaneously obtained at 128x128 pixels. The SWCNTs used for the measurements were obtained from a commercial source (As-produced HiPco nanotubes by Carbon Nanotechnology Inc.). 3. Results and Discussion 3.1. Confirmation of Timing Condition of Bias voltage, Z-control, Cantilever Excitation and Cantilever Vibration As described above, in the conventional PCI-AFM measurement, the Z-control is changed to the low state immediately after stopping cantilever excitation at the boundary between zones A and B in Fig.3(a), 5) even though the cantilever is still being vibrated (see arrow (i) in Fig. 3(a)). Due to the sudden height change, the cantilever crashed and kept bouncing on the sample, therefore a certain interval was needed to 6

stabilize the contact condition. We thus focused on the V A-B signal to monitor the cantilever vibration, which is controlled to be stopped before the end of the high state of Z-control (zone C ) in Fig. 3(b). The cantilever keeps vibrating for a short time period even though the bias for cantilever excitation is actually stopped at the end of zone C in Fig. 3(b). The cantilever vibration thus needs to be stopped until the end of the low state of Z-control. Next, the timing of each signal needs to be checked. Sweeping the sample bias should be started after the low state of Z-control has started and finished before the end (zone D in Fig. 3(b)). In the present measurement, the cantilever position is changed from the original height to the low state to contact the measured sample, similar to the condition shown in Fig 2(c). In the case wherein stable contact was late for the I-V measurement, an incorrect and irregular result was obtained, as indicated by region B in Fig. 4(a). To avoid unstable contact, the cantilever displacement was controlled to be slower than the conventional condition for mild collision to the sample. The speed of height change is empirically chosen. If the slope of Z-control is smaller than that in Fig 3(b), in other words, if the cantilever moves more gently than for the refined condition, the cantilever did not bounce on the sample after started I-V measurement. By this change, the quality of the measured data was obviously improved from the previous results. If the interaction 7

between the cantilever and sample is too strong for them to disconnect, for example, due to the presence of a sticky material, the cantilever can be retracted by a displacement large enough to disconnect the sample and the cantilever once and then returned to the original position. 10) 3.2 Checking the PCI-AFM measurement condition in detail The synchronizing condition can be checked by the shape of the current-bias (I-V) curves obtained. In the case wherein all the conditions were ideal, the I-V curve shown in Fig. 4(b) was obtained. In the case wherein the condition was bad, the I-V curve became irregular, as shown in Fig. 4(a). The noise shown in region B in Fig. 4(a) was observed when the I-V measurement was started without good contact, that is, when the cantilever contacted the sample before the cantilever vibration was stopped or the cantilever was bounced on the sample. The I-V curve in zone A in Fig. 4(a) was obtained when the cantilever was disconnected from the sample at -0.25 V and detected no current at the lower bias. It is to be noted that the bias voltage was swept from 1.5 V to -1.5 V in the measurements. When the I-V curve was irregular, such as in zone B in Fig. 4(a), it was always observed that the vibration of the cantilever was not stopped yet like at arrow (i) in Fig. 3(a). 8

The V A-B signal in the low state of the Z-condition also yields important information. The curves in Fig. 4(c) show V A-B (vibration of cantilever) when the cantilever was in contact with the sample. The distance from Z-control at the high state increased in the order from (i) to (iv). The insets on the right in the figure indicate the cantilever shape at each condition. In chart (i) in Fig. 4(c), the cantilever approaches the sample in the attractive force region when the Z-control was in the low state. In the case of chart (iii), the cantilever shape is the same when no force is applied because the attractive and repulsive forces are balanced. The cantilever feels a repulsive force in the case of chart (iv). At point C in the chart, the cantilever started to experience the attractive force from the sample. The spiky peak, as a signal of the attractive force between the sample and the cantilever, was observed when the two were disconnected as shown in area D of the charts (ii) to (iv) in Fig. 4(c). These peaks were observed for the I-V measurements since the cantilever must contact the sample during the measurement. Using the timing of the signals, Z-control can be controlled suitably with no clash between the sample and cantilever to avoid damage to both. To obtain both good quality PCI-AFM images and I-V curves, the case shown in chart (iii) allows for the best resolution for the topography and current images. In particular, the resolution of the current image was sometimes much higher than that of the topographic image, as shown in Fig. 5. The 9

results imply that the contact condition of the cantilever may become stable during measurement when the repulsive and attractive forces are balanced. By setting all the conditions as described above, we were successful in distinguishing six SWCNTs on the surface of a bundle of nanotubes in a current image, as shown in Fig. 5(b). This suggests that the PCI-AFM images and I-V curves can be obtained simultaneously and reliably. From the topographic image, diameter of the bundled SWCNT is estimated about 4 nm although it looks much wider in the observed image because the curvature of AFM probes makes the width wider in AFM image. It is reasonable that 5-6 nanotubes are observed at the surface of the bundle structure. In particular, the resolution of the current image exceeded that of the topographic image. The present result is much improved when compared to that obtained by contact mode AFM previously. 11) The present refinement was thus shown to be useful for distinguishing electric properties of 1D nanoscale structures. 4. Conclusions We optimized conditions for using PCI-AFM to obtain the best results. This will help researchers in measuring the electric properties along the long axes of 1D structures. Using the conditions, the current image of PCI-AFM was demonstrated to show the 10

distribution of conductivity along individual SWCNTs in a bundled structure. Acknowledgments This work was supported by the Grant-in-Aid for Key-Technology, "Atomic Switch Programmed Device" and by Grants-in-Aid for Scientific Research (Nos.15201028, 14654135 and 18710104) from the Ministry of Education, Culture, Sports, Science, and Technology of Japan. One of the authors (HT) thanks Visionarts Inc., Ishikawa Carbon Foundation and Shimadzu Foundation for financial support. 11

(a) electrode (b) insulated substrate conductive cantilever 1D structure material Fig.1; Problem of measurement of the conductivity of a 1D material by contact mode AFM. (a) Typical measurement. AFM probe is scanned along the dashed line, for example, and I-V curve is obtained at each pixel of an image. (b) If the 1D material has a small interaction with the substrate, the sample can be moved easily by the scanned cantilever. 12

(a) Au electrode (b) 1D structure material Insulated substrate Conductive cantilever Repeat 128 128pts. (c) current Fig. 2; Procedure of the PCI-AFM method. (a) A topographic image was obtained by tapping-mode AFM. (b) The vibration of the cantilever was stopped to measure the I-V curve. (c) The AFM tip was pressed to the sample to make electrical contact, and the I-V curve was then measured. Steps (a)-(c) were repeated at each of 128 128 pixels of the AFM image. 13

Fig. 3 Timing chart of Z-control, cantilever excitation and cantilever vibration (V A-B ) for (a) conventional condition and (b) refined condition. The cantilever vibration was 14

stopped when the Z-control was at a low state. The characters H and L indicate high state and low state of the cantilever position. Arrows (i) indicate an unstable contact condition when the cantilever crashes on the sample. In zones A and C, the excitation of cantilever was on, while in zone B, C and D the excitation was off. 15

(a) A A B B (b) Bias Voltage (V) Bias Voltage (V) (c) C cantilever (i) (ii) D sample (iii) V A-B (V) 0.2 (iv) 0.0-0.2 0.00 0.01 0.02 Time (s) Fig. 4 I-V curves obtained by (a) unsuitable conditions for PCI-AFM and (b) optimized condition. Bias voltage was swept from 1.5 V to -1.5 V in the measurements in (a) and (b). The I-V curve in region A was obtained when the cantilever was disconnected from the sample at -0.25 V and detected no current at the lower bias. The noise shown in region B was observed when the I-V measurement was started without good contact, that is, when the cantilever contacted the sample before the cantilever vibration was 16

stopped or the cantilever was bounced on the sample. (c) V A-B during I-V measurements for (i) attractive force region with no contact to the sample (red), (ii) first contact position (green) (iii) force balanced region (light blue) and (iv) repulsion force region (blue). The dashed lines show the average bias of the free force region. The insets on the right side show the shapes of the cantilever for each case in (c). V A-B for (iii) is on the averaged line, which are same range in curves (i)-(iv). At point C, the cantilever started to experience the attractive force from the sample. The spiky peak shown in area D, as a signal of the attractive force between the sample and the cantilever, was observed when the two were disconnected. The distance from Z-control at the high state increased in order from (i) to (iv). 17

(a) 30 nm (b) 30 nm Fig.5 (a) PCI-AFM topographic image of bundled SWCNTs, and (b) current image at -1.5 V obtained in the same area. Six dark (higher current indicates darker color in the picture) strips indicated by the red triangles were observed as individual nanotubes on the surface of a bundled SWCNT wire, which can be distinguished only in the current image. Improvement in the resolution was due to the refined conditions of PCI-AFM. 18

REFERENCES. 1) A. Bezryadin, C. Dekker, and G. Schmid, Appl. Phys. Lett. 71 (1997) 1273. 2) C. J. Muller, J. M. Vanruitenbeek, and L. J. Dejongh, Phys. Rev. Lett. 69 (1992) 140. 3) A. F. Morpurgo, C. M. Marcus, and D. B. Robinson, Appl. Phys. Lett. 74 (1999) 2084. 4) H. Park, A. K. L. Lim, A. P. Alivisatos, J. Park, and P. L. McEuen, Appl. Phys. Lett. 75 (1999) 301. 5) Y. Otsuka, Y. Naitoh, T. Matsumoto, and T. Kawai, Jpn. J. Appl. Phys. 2 41 (2002) L742. 6) Y. Otsuka, Y. Naitoh, T. Matsumoto, and T. Kawai, Appl. Phys. Lett. 82 (2003) 1944. 7) H. Tanaka, T. Yajima, T. Matsumoto, Y. Otsuka, and T. Ogawa, Adv. Mater. 18 (2006) 1411. 8) H. Tanaka, T. Yajima, M. Kawao, and T. Ogawa, J. Nanosci. Nanotechnol. 6 (2006) 1644. 9) A. Terawaki, Y. Otsuka, H. Y. Lee, T. Matsumoto, H. Tanaka, and T. Kawai, Appl. Phys. Lett. 86 (2005) 113901. 10) H. Azehara, T. T. Liang, T. Ishida, Y. Naitoh, and W. Mizutani, Jpn. J. Appl. Phys. 43 (2004) 4511. 11) A. Fujiwara, R. Iijima, K. Ishii, H. Suematsu, H. Kataura, Y. Maniwa, S. Suzuki, and Y. Achiba, Appl. Phys. Lett. 80 (2002) 1993. 19