Item Number No. Poles NO/NC V DC 50/60 Hz. Aux Contactor NO/NC Resistive/ Inductive Amps Price. AF Series

Top wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations

AC-3 AC-1 230V 400/415V 500V 690V 115V 230V 200V 230V 460V 575V N.O. N.C. Qty. Cat. No. Screw Terminals. Spring Clamp Terminals. 40 C Pkg.

Auxiliary Contact (10 600V) Auxiliary Contact (10 5V DC)

LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC

Characteristics 5 TeSys k contactors and reversing contactors

Open Type Without Enclosure

SIRCO M UL98 Load break switches standards UL and CSA 30 to 100 A

Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13

Motor starters. TeSys E. Designed for the essential

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks

XT IEC Power Control Miniature Controls

190S A N D 2 C A16 C TE

LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

Mini contactors B 6 and B 7 Mini contactor relays K.. Compact reversing contactors VB.. Thermal overload relay T 7 DU

LC1D12BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

3RA13, 3RA14 Contactor Assemblies

LC1D32BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 24 V DC coil

Bulletin 100S-C/104S-C Safety Contactors. Bulletin 700S-CF Safety Control Relays. Table of Contents. Selection Guide

The CWC0 compact contactors are offered as a complete solution for switching and controlling motors.

NEMA Size 1 Cat. No. CN55DN3AB

CI-tronic Soft start motor controller

SIRCO M UL 98 Load break switches standards UL and CSA from 30 to 100 A

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Open Type Without Enclosure

Switches Unlimited Contact: Phone: Fax:

Deploying Current Transformers in Applications Greater Than 200 A

Utilization category DC-1 DC-3 DC-5 L/R 1 ms L/R 2 ms L/R 7.5 ms

AC Coil $ Unit MRP R. DC Coil Voltage. Code n B4 F4 M4. Coil voltage Unit MRP DC Coil Voltage. Auxillary contacts A NO NC

Ratings for Switching AC Motors AC-2, AC-3, AC / /

NS..S contactor relays - with spring terminals AC operated

IGS IGS-M-EL-22(1) Contactors APPROVED. Iranian Gas Standards

02/11/2015

SOLID STATE RELAY RATINGS

LC1D32ED TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 48 V DC coil

and START pushbutton mounted on the enclosure and a RESET button on the front wiring is as illustrated in the wiring diagram on Page 6-3.

Controls Contactors and Contactor Assemblies Special Applications

Ratings for Switching AC Motors AC-2, AC-3, AC / /

Miniature Contactors & Starters. Series CA8 family of Contactors, Starters, and Overload & Industrial Relays

DPC F - P3-24. Part Number Scheme. Dimensions

AF AF V50/60HZ-DC Contactor. General Information. Ordering. Popular Downloads. Dimensions. Technical AF

Type: DILEM 10(220V50HZ,240V60HZ) Article No.:

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

Siemens AG Allows easy and consistent configuration with one series of overload relays (for small to large loads)

For additional PowerFlex 4 and 40 data and general drive information, refer to the following publications:

T e c h n i c a l C a t a l o g u e MCCB. Moulded Case Circuit Breaker

NEMA Contactor and Starter Specifications

Page 4-6. STAR-DELTA STARTERS OPEN FRAME Suitable for three-phase motor control, 16A...690A 440V / 7.5kW...375kW 400V ratings in IEC AC3 duty.

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE

190S A N D 2 C A16 C TE

LC1D12BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

Standard voltages. Alternating current (V). Direct current (V) D F H J N Y Voltage For contactors type CL...

Industrial Controls. Catalog IC SIRIUS. Answers for industry.

Motor Control V12-T13-2 V12-T13-72 V12-T13-76 V12-T13-87

Modular Devices and Enclosures

Type: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information

Modular equipment. Presentation, standards. Standard contactors TeSys GC

3 - Protection components Circuit-breakers

Type: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

3.6. Control Relays and Timers D A M D 2. Contents. Product Overview. Catalog Number Selection. Solid-State Relays

Output of three-phase motors at 50 Hz and 400 V

Block Contactors. Contents. Panorama 3-pole Contactors... 2/2 4-pole Contactors... 2/4

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories

Type: DILEM 10 G(24VDC) Article No.:

For Immediate Delivery call KMParts.com at (866)

IPS INTELLIGENT PUMP STARTER. Integrated Tru-power electronic motor and pump protection

PKZ 2 Manual Motor Protectors Technical Data

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Power connections, minimum and maximum wiring capabilities, tightening torque

HG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS

General 2 Approvals 3 Technical Information 5 Mounting Information 6

The SSR P Series. Phase-Fired SCR Power Controllers. for resistive heating loads. Phase-Fired SCR Power Controllers AMPS VAC

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

References 1 for asynchronous motors 1

02/11/2015

Solid State Relays 1- and 2 Pole SOLITRON With Integrated Heatsink

AC-Operated Latch Units PKLL11. Reset Input. DC-Operated Latch Units DC-PKLL10

Table of Contents. Contents. Section 1: Introduction General... 2

58 SERIES. Relay interface modules 7-10 A 58.P3 58.P4

Accessories Field Installable

48 SERIES. Relay interface modules 8 A CO forcibly guided contacts relay interface modules,15.8 mm wide Type 48.12

Control relays. K mini-control relays. 2 or 4 for CA2-K and CA3-K: 2 for CA4-K. Conforming to VDE 0110 group C V 750

SIEMENS ENERGY & AUTOMATION INC DISTRIBUTION PRODUCTS DIV

MODEL 421 Over/Under Motor Load Monitor

Selection tables Command devices E 250 latching relays

02/11/2015

Power PCB Relay. To Order: Select the part number and add the desired coil voltage rating (e.g., G6B-1114-US-DC6).

DISCONNECT SWITCHES. UL Listed CSA Certified

Protection relays and transformers

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

Connection Diagrams. Auxiliary 40 C 60 C 24/48V 120V 240V 400V 500V 600V 690V Contacts Contacts N.O. N.C. Contacts 43 K

02/11/2015

PowerFlex 400 Submittal

AF91 Adjustable Frequency Drives Series B

Softstarters. Specification guide. Type PST. Low Voltage Products & Systems

Transcription:

4 US Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements) Standards: UL508, CSA C22.2, IEC 60947, and CE Marked Integral DIN Rail & Base Mounting in One Compact Footprint Superior ISO Quality Proven by Multiple Global Standard Certifications Contactors - (LC1D) 3P 600Vmax - 120Vac Control (Included) Size US Breaker- Telemecanique Cross Reference iliaries Price NC1- Brand Part # Direct Similar 1) Description NO NC Each NC1 D09-D18 D09 0910 - V120 LC1D0910 - G6 LC1D09 - G7 NC1-D09 Contactor 09A (Ith=20A) 3 Main + 1NO 1 0 $12.98 0901 - V120 LC1D0901 - G6 LC1D09 - G7 NC1-D09 Contactor 09A (Ith-20A) 3 Main + 1NC 0 1 $12.98 1210 - V120 LC110 - G6 LC1 - G7 NC1- Contactor 12A (Ith=20A) 3 Main + 1NO 1 0 $15.99 1201 - V120 LC101 - G6 LC1 - G7 NC1- Contactor 12A (Ith=20A) 3 Main + 1NC 0 1 $15.99 D18 1810 - V120 LC1D1810 - G6 LC1D18 - G7 NC1-D18 Contactor 18A (Ith=32A) 3 Main + 1NO 1 0 $20.65 1801 - V120 LC1D1801 - G6 LC1D18 - G7 NC1-D18 Contactor 18A (Ith=32A) 3 Main + 1NC 0 1 $20.65 2510 - V120 LC110 - G6 LC1 - G7 NC1- Contactor 25A (Ith=40A) 3 Main + 1NO 1 0 $24.94 2501 - V120 LC101 - G6 LC1 - G7 NC1- Contactor 25A (Ith=40A) 3 Main + 1NC 0 1 $24.94 D32 3210 - V120 LC1D3210 - G6 LC1D32 - G7 NC1-D32 Contactor 32A (Ith=50A) 3 Main + 1NO 1 0 $33.96 D40 4011 - V120 LC1D4011 - G6 LC1D40 - G7 NC1-D40 Contactor 40A (Ith=50A) 3 Main + 1NO/1NC 1 1 $41.88 D50 5011 - V120 LC1D5011 - G6 LC1D50 - G7 NC1-D50 Contactor 50A (Ith=60A) 3 Main + 1NO/1NC 1 1 $52.69 D65 6511 - V120 LC1D6511 - G6 LC1D65 - G7 NC1-D65 Contactor 65A (Ith=80A) 3 Main + 1NO/1NC 1 1 $59.96 D80 8011 - V120 LC1D8011 - G6 LC1D80 - G7 NC1-D80 Contactor 80A (Ith=95A) 3 Main + 1NO/1NC 1 1 $68.49 D95 9511 - V120 LC1D9511 - G6 LC1D95 - G7 NC1-D95 Contactor 95A (Ith=95A) 3 Main + 1NO/1NC 1 1 $78.88 Contactors - (LC1D) 3P 600Vmax - 24Vac Control (Included) Size US Breaker- Telemecanique Cross Reference iliaries Price NC1- Brand Part # Direct Similar 1) Description NO NC Each NC1 -D32 NC1 D40-D65 D09 0910 - V24 LC1D0910 - B7 LC1D09 - B7 NC1-D09 Contactor 09A (Ith=20A) 3 Main + 1NO 1 0 $12.98 0901 - V24 LC1D0901 - B7 LC1D09 - B7 NC1-D09 Contactor 09A (Ith-20A) 3 Main + 1NC 0 1 $12.98 1210 - V24 LC110 - B7 LC1 - B7 NC1- Contactor 12A (Ith=20A) 3 Main + 1NO 1 0 $15.99 1201 - V24 LC101 - B7 LC1 - B7 NC1- Contactor 12A (Ith=20A) 3 Main + 1NC 0 1 $15.99 D18 1810 - V24 LC1D1810 - B7 LC1D18 - B7 NC1-D18 Contactor 18A (Ith=32A) 3 Main + 1NO 1 0 $20.65 1801 - V24 LC1D1801 - B7 LC1D18 - B7 NC1-D18 Contactor 18A (Ith=32A) 3 Main + 1NC 0 1 $20.65 2510 - V24 LC110 - B7 LC1 - B7 NC1- Contactor 25A (Ith=40A) 3 Main + 1NO 1 0 $24.94 2501 - V24 LC101 - B7 LC1 - B7 NC1- Contactor 25A (Ith=40A) 3 Main + 1NC 0 1 $24.94 D32 3210 - V24 LC1D3210 - B7 LC1D32 - B7 NC1-D32 Contactor 32A (Ith=50A) 3 Main + 1NO 1 0 $33.96 D40 4011 - V24 LC1D4011 - B7 LC1D40 - B7 NC1-D40 Contactor 40A (Ith=50A) 3 Main + 1NO/1NC 1 1 $41.88 D50 5011 - V24 LC1D5011 - B7 LC1D50 - B7 NC1-D50 Contactor 50A (Ith=60A) 3 Main + 1NO/1NC 1 1 $52.69 D65 6511 - V24 LC1D6511 - B7 LC1D65 - B7 NC1-D65 Contactor 65A (Ith=80A) 3 Main + 1NO/1NC 1 1 $59.96 D80 8011 - V24 LC1D8011 - B7 LC1D80 - B7 NC1-D80 Contactor 80A (Ith=95A) 3 Main + 1NO/1NC 1 1 $68.49 D95 9511 - V24 LC1D9511 - B7 LC1D95 - B7 NC1-D95 Contactor 95A (Ith=95A) 3 Main + 1NO/1NC 1 1 $78.88 Contactors - (LC1D) 3P 600Vmax - 240Vac Control (Included) Size US Breaker- Telemecanique Cross Reference iliaries Price NC1- Brand Part # Direct Similar 1) Description NO NC Each D09 0910 - V240 LC1D0910 - U7 LC1D09 - U7 NC1-D09 Contactor 09A (Ith=20A) 3 Main + 1NO 1 0 $12.98 0901 - V240 LC1D0901 - U7 LC1D09 - U7 NC1-D09 Contactor 09A (Ith-20A) 3 Main + 1NC 0 1 $12.98 1210 - V240 LC110 - U7 LC1 - U7 NC1- Contactor 12A (Ith=20A) 3 Main + 1NO 1 0 $15.99 1201 - V240 LC101 - U7 LC1 - U7 NC1- Contactor 12A (Ith=20A) 3 Main + 1NC 0 1 $15.99 D18 1810 - V240 LC1D1810 - U7 LC1D18 - U7 NC1-D18 Contactor 18A (Ith=32A) 3 Main + 1NO 1 0 $20.65 1801 - V240 LC1D1801 - U7 LC1D18 - U7 NC1-D18 Contactor 18A (Ith=32A) 3 Main + 1NC 0 1 $20.65 2510 - V240 LC110 - U7 LC1 - U7 NC1- Contactor 25A (Ith=40A) 3 Main + 1NO 1 0 $24.94 2501 - V240 LC101 - U7 LC1 - U7 NC1- Contactor 25A (Ith=40A) 3 Main + 1NC 0 1 $24.94 D32 3210 - V240 LC1D3210 - U7 LC1D32 - U7 NC1-D32 Contactor 32A (Ith=50A) 3 Main + 1NO 1 0 $33.96 D40 4011 - V240 LC1D4011 - U7 LC1D40 - U7 NC1-D40 Contactor 40A (Ith=50A) 3 Main + 1NO/1NC 1 1 $41.88 NC1 D80-D95 D50 5011 - V240 LC1D5011 - U7 LC1D50 - U7 NC1-D50 Contactor 50A (Ith=60A) 3 Main + 1NO/1NC 1 1 $52.69 D65 6511 - V240 LC1D6511 - U7 LC1D65 - U7 NC1-D65 Contactor 65A (Ith=80A) 3 Main + 1NO/1NC 1 1 $59.96 D80 8011 - V240 LC1D8011 - U7 LC1D80 - U7 NC1-D80 Contactor 80A (Ith=95A) 3 Main + 1NO/1NC 1 1 $68.49 D95 9511 - V240 LC1D9511 - U7 LC1D95 - U7 NC1-D95 Contactor 95A (Ith=95A) 3 Main + 1NO/1NC 1 1 $78.88

5 US Breaker Brand 4 Pole AC Contactors (Square D Telemecanique LC1 Replacements) Contactors - (LC1D) 4P 600Vmax - 120Vac Control (Included) Size US Breaker- Telemecanique Cross Reference Main Contacts Price 1208 NC1- Brand Part # Direct Similar Description NO NC Each 1204 - V120 LC1004 - G6 LC1DT20 - G7 NC1- Contactor 12A (Ith=20A) 4 NO Main Contacts 4 0 $24.91 1208 - V120 LC1008 - G6 LC1D098 - G7 NC1- Contactor 12A (Ith=20A) 2NO/2NC Main Contacts 2 2 $24.91 2504 - V120 LC1004 - G6 LC1DT40 - G7 NC1- Contactor 25A (Ith=40A) 4 NO Main Contacts 4 0 $42.90 2508 - V120 LC1008 - G6 LC18 - G7 NC1- Contactor 25A (Ith=40A) 2NO/2NC Main Contacts 2 2 $42.90 D65 6504 - V120 LC1D65004 - G6 LC1D65004 - G7 NC1-D65 Contactor 65A (Ith=80A) 4 NO Main Contacts 4 0 $89.00 6508 - V120 LC1D65008 - G6 LC1D65008 - G7 NC1-D65 Contactor 65A (Ith=80A) 2NO/2NC Main Contacts 2 2 $89.00 D95 9504 - V120 LC1D80004 - G6 LC1D80004 - G7 NC1-D95 Contactor 65A (Ith=95A) 4 NO Main Contacts 4 0 $109.00 9508 - V120 LC1D80008 - G6 LC1D80008 - G7 NC1-D95 Contactor 95A (Ith=95A) 2NO/2NC Main Contacts 2 2 $109.00 Contactors - (LC1D) 4P 600Vmax - 24Vac Control (Included) Size US Breaker- Telemecanique Cross Reference Main Contacts Price 2504 NC1- Brand Part # Direct Similar Description NO NC Each 1204 - V24 LC1004 - B7 LC1DT20 - B7 NC1- Contactor 12A (Ith=20A) 4 NO Main Contacts 4 0 $24.91 1208 - V24 LC1008 - B7 LC1D098 - B7 NC1- Contactor 12A (Ith=20A) 2NO/2NC Main Contacts 2 2 $24.91 2504 - V24 LC1004 - B7 LC1DT40 - B7 NC1- Contactor 25A (Ith=40A) 4 NO Main Contacts 4 0 $42.90 2508 - V24 LC1008 - B7 LC18 - B7 NC1- Contactor 25A (Ith=40A) 2NO/2NC Main Contacts 2 2 $42.90 D65 6504 - V24 LC1D65004 - B7 LC1D65004 - B7 NC1-D65 Contactor 65A (Ith=80A) 4 NO Main Contacts 4 0 $89.00 6508 - V24 LC1D65008 - B7 LC1D65008 - B7 NC1-D65 Contactor 65A (Ith=80A) 2NO/2NC Main Contacts 2 2 $89.00 D95 9504 - V24 LC1D80004 - B7 LC1D80004 - B7 NC1-D95 Contactor 65A (Ith=95A) 4 NO Main Contacts 4 0 $109.00 9508 - V24 LC1D80008 - B7 LC1D80008 - B7 NC1-D95 Contactor 95A (Ith=95A) 2NO/2NC Main Contacts 2 2 $109.00 Contactors - (LC1D) 4P 600Vmax - 240Vac Control (Included) Size US Breaker- Telemecanique Cross Reference Main Contacts Price 6508 NC1- Brand Part # Direct Similar Description NO NC Each 1204 - V240 LC1004 - U6 LC1DT20 - U7 NC1- Contactor 12A (Ith=20A) 4 NO Main Contacts 4 0 $24.91 1208 - V240 LC1008 - U6 LC1D098 - U7 NC1- Contactor 12A (Ith=20A) 2NO/2NC Main Contacts 2 2 $24.91 2504 - V240 LC1004 - U6 LC1DT40 - U7 NC1- Contactor 25A (Ith=40A) 4 NO Main Contacts 4 0 $42.90 2508 - V240 LC1008 - U6 LC18 - U7 NC1- Contactor 25A (Ith=40A) 2NO/2NC Main Contacts 2 2 $42.90 D65 6504 - V240 LC1D65004 - U6 LC1D65004 - U7 NC1-D65 Contactor 65A (Ith=80A) 4 NO Main Contacts 4 0 $89.00 6508 - V240 LC1D65008 - U6 LC1D65008 - U7 NC1-D65 Contactor 65A (Ith=80A) 2NO/2NC Main Contacts 2 2 $89.00 D95 9504 - V240 LC1D80004 - U6 LC1D80004 - U7 NC1-D95 Contactor 65A (Ith=95A) 4 NO Main Contacts 4 0 $109.00 9508 - V240 LC1D80008 - U6 LC1D80008 - U7 NC1-D95 Contactor 95A (Ith=95A) 2NO/2NC Main Contacts 2 2 $109.00 9508 US Breaker Brand 3 Pole 115-265A Contactors Contactors - Series F (LC1F) 600V - 120Vac Control (Included) Size US Breaker- Telemecanique Cross Ref. iliaries Price Ref Brand Part # Direct Description NO NC Each F115 F115 P3 V120 LC1F115 - G6 3 Pole Contactor 115A (Ith=200A) with 120Vac - - $153.00 F150 F150 P3 V120 LC1F150 - G6 3 Pole Contactor 150A (Ith=200A) with 120Vac - - $219.00 F185 F185 P3 V120 LC1F185 - G6 3 Pole Contactor 185A (Ith=275A) with 120Vac - - $298.00 F265 F265 P3 V120 LC1F265 - G6 3 Pole Contactor 265A (Ith=315A) with 120Vac - - $367.00 Contactors - Series F (LC1F) 600V - 240Vac Control (Included) F185 Size US Breaker- Telemecanique Cross Ref. iliaries Price Ref Brand Part # Direct Description NO NC Each F115 F115 P3 V240 LC1F115 - U6 3 Pole Contactor 115A (Ith=200A) with 240Vac - - $153.00 F150 F150 P3 V240 LC1F150 - U6 3 Pole Contactor 150A (Ith=200A) with 240Vac - - $219.00 F185 F185 P3 V240 LC1F185 - U6 3 Pole Contactor 185A (Ith=275A) with 240Vac - - $298.00 F265 F265 P3 V240 LC1F265 - U6 3 Pole Contactor 265A (Ith=315A) with 240Vac - - $367.00 Please contact US Breaker for other & Series F family contactor coil voltages. Telemecanique part numbers are provided to assist in product selection. Proper engineering evaluation is required for each customer application. 1) US Breaker 3 pole D09 - D32 contactors include either a 1NO or 1NC aux contact in the 4th pole. Add an NC-F4-11 if an additional front auxiliary contact is required.

6 NCF411 NCF422 NCF111C NCSR2A NC Family Contactor Accessories (Square D Telemecanique Replacements) iliary Contacts for NC 9A to 265A Contactors NC F4 20 LA1DN 20 LADN 20 2 NO Front Mount (Ui=690V, Ith=10A, AC15=380VA) for all NC Contactors 9A - 265A $7.00 NC F4 11 LA1DN 11 LADN 11 1NO/1NC Front Mount (Ui=690V, Ith=10A, AC15=380VA) for all NC Contactors 9A - 265A $7.00 NC F4 02 LA1DN 02 LADN 02 2NC Front Mount (Ui=690V, Ith=10A, AC15=380VA) for all NC Contactors 9A - 265A $7.00 NC F4 40 LA1DN 40 LADN 40 4NO Front Mount (Ui=690V, Ith=10A, AC15=380VA) for all NC Contactors 9A - 265A $11.50 NC F4 31 LA1DN 31 LADN 31 3NO/1NC Front Mount (Ui=690V, Ith=10A, AC15=380VA) for all NC Contactors 9A - 265A $11.50 NC F4 04 LA1DN 04 LADN 04 4NC Front Mount (Ui=690V, Ith=10A, AC15=380VA) for all NC Contactors 9A - 265A $11.50 NC F4 22 LA1DN 22 LADN 22 2NO/2NC Front Mount (Ui=690V, Ith=10A, AC15=380VA) for all NC Contactors 9A - 265A $11.50 NCF1 11C LA8DN 11 LA8DN 11 1NO/1NC Side Mount (Ui=690V, Ith=10A, AC15=380VA) for NC1 D09 to D32 Contactors $9.90 Surge Supressors for NC 9A to 32A Contactors NCSR2A120240 - - Surge Suppressor for NC1 D09 to D32 Contactor s from 100V - 250Vac $9.98 NCSR2A24 - - Surge Suppressor for NC1 D09 to D32 Contactor s from 24V - 48Vac $9.98 Front Mounted Time Delay Blocks for NC 9A - 265A Contactors NC F5 T2 LA2DT2 LADT2 NC 9A to 265A Time Delay Block 0.1-30s Making Time Delay with 1NO/1NC Contacts $26.00 NC F5 D2 LA3DR2 LADR2 NC 9A to 265A Time Delay Block 0.1-30s Breaking Time Delay with 1NO/1NC Contacts $26.00 NCF5 NCMI0932A Mechanical Interlocks for Reversing Application of NC Contactors NC MI 09 32A LA9D9978 LAD9R1 NC1-D Mechanical Interock for Reversing Application Sizes D09,, D18,, D32 $8.95 NC MI 40 65A LA9D50978 LA9D50978 NC1-D Mechanical Interock for Reversing Application Sizes D40, D50, D65 $9.95 NC MI 80 95A LA9D80978 - NC1-D Mechanical Interock for Reversing Application Sizes D80, D95 $10.95 * Mechanical interlocks are available for series F115 to F265 contactors. Please contact us for details. Contactor Technical Data Type NC1-D09 NC1- NC1-D18 NC1- NC1-D32 NC1-D40 NC1-D50 NC1-D65 NC1-D80 NC1-D95 Thermal Current Ith (AC-1 IEC) Amps 660V 20 20 32 40 50 50 60 80 95 95 Inductive Current (AC-3 IEC) Amps 380/400V 9 12 18 25 32 40 50 65 80 95 240V 3 5 7.5 10 15 20 20 25 30 30 UL Power Rating 460V 5 7.5 10 15 20 25 30 40 40 50 3 Phase (Hp) 600V 5 7.5 10 15 20 25 30 40 40 50 UL Power Rating 120V 0.5 0.75 1 2 3 3 5 5 7.5 7.5 1 Phase (Hp) 240V 1 2 3 5 5 7.5 10 15 20 20 IEC Power Rating (KW) 380/400V 4 5.5 7.5 11 15 18.5 22 30 37 45 Operations (AC-3) Elec. 1,000,000 1,000,000 1,000,000 1,000,000 800,000 800,000 800,000 800,000 600,000 600,000 Mech. 10,000,000 10,000,000 10,000,000 10,000,000 8,000,000 8,000,000 8,000,000 8,000,000 6,000,000 6,000,000 Contactor Data Type NC1-D09 NC1- NC1-D18 NC1- NC1-D32 NC1-D40 NC1-D50 NC1-D65 NC1-D80 NC1-D95 Start-up (VA) 70 70 70 110 110 200 200 200 200 200 Power Holding (VA) 8 8 8 11 11 20 20 20 20 20 Power (W) 1.8-2.7 1.8-2.7 1.8-2.7 3-4 3-4 6-10 6-10 6-10 6-10 6-10 Operation Range Pick-up Voltage 85% - 110% of Rated Voltage Drop-out Voltage 20% - 75% AC Volts 24V 48V 110V 120V 208V 220V 230V 240V 440V 480V Identification Code B7 E7 F7 G6 L6 M7 P7 U6 R5 T6

7 F115 - F265 Contactor Technical Data Series F Type F115 F150 F185 F265 Thermal Current Ith (AC-1) Amps 660V 200 200 275 315 Inductive Current IEC (AC-3) Amps 400V 115 150 185 265 240V 40 50 60 100 UL Power Rating 460V 75 100 100 150 (Hp) 600V 75 100 100 150 IEC Power Rating 230V 33 45 55 80 (KW) 400V 55 75 90 132 Operations Elec. 1,200,000 1,200,000 1,000,000 800,000 Mech. 10,000,000 10,000,000 6,000,000 6,000,000 Series F Contactor Data Series F Type F115 F150 F185 F265 Power Start-up (VA) 660 660 966 840 Holding (VA) 54 54 66 12 Operation Range of Pick-up Voltage 85% - 110% Rated Voltage Drop-out Voltage 20% - 75% NC1-D09 to NC1-D32 Contactor Dimensions (in.) NC1-D40 to NC1-D95 Dim (in) H W D Daux a b Ǿ NC1 D09 to 3.0 1.9 3.2 4.7 1.3-1.4 2.0-2.4 0.18 NC1 D18 3.0 1.9 3.4 4.9 1.3-1.4 2.0-2.4 0.18 NC1 3.4 2.2 3.7 5.3 1.6 1.9 0.18 NC1 D32 3.4 2.2 3.9 5.5 1.6 1.9 0.18 Dim (in) H W D Daux a b Ǿ NC1 D4011 to D6511 5.1 3.0 4.6 6.1 1.6 3.9 0.26 NC1 D6504 & D6508 5.1 3.3 4.6 6.1 1.6 3.9 0.26 NC1 D8011 to D9511 5.1 3.4 5.0 6.5 1.6 3.9-4.3 0.26 NC1 D9504 & D9508 5.1 3.8 5.0 6.5 1.6 3.9-4.3 0.26 Series F Contactor Dimensions 3P Dim (in) H W D E F G J K a b x y <500V y >500V Ǿ - Bolt Torque F115 6.4 6.6 6.8 1.5 0.8 5.8 4.9 4.2 3.1 4.3-4.7 5.2 0.4 0.6 M6 3 N M F150 6.7 6.6 6.8 1.6 0.8 5.9 4.9 4.2 3.1 4.3-4.7 5.2 0.4 0.6 M8 6 N M F185 6.9 6.7 7.2 1.6 0.8 6.1 5.0 4.5 3.1 4.3-4.7 5.2 0.4 0.6 M8 6 N M F265 8.0 8.0 8.5 1.9 1.0 7.0 5.8 5.6 3.8 4.3-4.7 5.8 0.4 0.6 M10 10 N M Telemecanique part numbers are provided to assist in product selection. Proper engineering evaluation is required for each customer application. NC accessories are intended and UL listed for use with their associated & series F contactors.

8 US Breaker Brand Overload Relays for Contactors (Square D Telemecanique 2 Replacements) Standards: UL508, CSA C22.2, IEC 60947, and CE Marked Class 10 Ambient Compensated Overload with Phase Loss Protection Direct Mounts to NC1 Contactor or Individual Mounting Bracket Includes 1NO/1NC iliary Contact Adjustable Amperage Ranges with Automatic and Manual Reset Superior ISO Quality Proven by Multiple Global Standard Certifications 25 36 93 Overload Relays - Series (for Contactors) - 0.63 to 93A Brand Part # Direct Similar Descrixtion Each 25 A01 2 D1305 D05.63-1.0A Adjustable Overload Mounts to NC1- D09,, D18, or D32 Contactor $18.63 25 A1x6 2 D1306 D06 1.0-1.6A Adjustable Overload Mounts to NC1- D09,, D18, or D32 Contactor $18.63 25 A2x5 2 D1307 D07 1.6-2.5A Adjustable Overload Mounts to NC1- D09,, D18, or D32 Contactor $18.63 25 A04 2 D1308 D08 2.5-4A Adjustable Overload Mounts to NC1- D09,, D18, or D32 Contactor $18.63 25 A06 2 D1310 D10 4-6A Adjustable Overload Mounts to NC1- D09,, D18, or D32 Contactor $18.63 25 A08 2 D1312 5.5-8A Adjustable Overload Mounts to NC1- D09,, D18, or D32 Contactor $18.63 25 A10 2 D1314 D14 7-10A Adjustable Overload Mounts to NC1- D09,, D18, or D32 Contactor $18.63 25 A13 2 D1316 D16 9-13A Adjustable Overload Mounts to NC1- D09,, D18, or D32 Contactor $18.63 25 A18 2 D1321 D21 12-18A Adjustable Overload Mounts to NC1-, D18, or D32 Contactor $18.63 25 A25 2 D1322 D22 17-25A Adjustable Overload Mounts to NC1- D18, or D32 Contactor $18.63 36 A32 2 D2353 D32 23-32A Adjustable Overload Mounts to NC1-D D32 Contactor $27.38 93 A32 2 D3353 D3353 23-32A Adjustable Overload Mounts to NC1- D40,, D50, D65, D80, D95 Contactor $31.13 93 A40 2 D3355 D3355 30-40A Adjustable Overload Mounts to NC1- D40,, D50, D65, D80, D95 Contactor $31.13 93 A50 2 D3357 D3357 37-50A Adjustable Overload Mounts to NC1- D40,, D50, D65, D80, D95 Contactor $34.88 93 A65 2 D3359 D3359 48-65A Adjustable Overload Mounts to NC1- D40,, D50, D65, D80, D95 Contactor $34.88 93 A70 2 D3361 D3361 55-70A Adjustable Overload Mounts to NC1- D40,, D50, D65, D80, D95 Contactor $37.38 93 A80 2 D3363 D3363 63-80A Adjustable Overload Mounts to NC1- D40,, D50, D65, D80, D95 Contactor $37.38 93 A93 - - 80-93A Adjustable Overload Mounts to NC1- D40,, D50, D65, D80, D95 Contactor $49.00 D13 Overload Relay Individual Mounting Adapters 0.63 TO 93A D13 LA7D1064-25 Overload Relay Base for Individual DIN Rail Mounting all 25 Overloads $5.50 D23 LA7D2064-36 Overload Relay Base for Individual DIN Rail Mounting all 36 Overloads $9.50 D33 LA7D3064-93 Overload Relay Base for Individual DIN Rail Mounting all 93 Overloads $11.00 200 Individual Mount Overload Relays - Series 80 to 200A 200 A125-2F5367 80A-125A Adj. Overload Relay for Assembly with F115, F150 & F185 $83.99 200 A160 2F5369 100A-160A Adj. Overload Relay for Assembly with F115, F150 & F185 $105.90 200 A200-2F5371 125A-200A Adj. Overload Relay for Assembly with F115, F150 & F185 $117.00 Manufacturer cross references are provided to assist in product selection. Proper engineering evaluation is required for each customer application. Series overload relays are intended and UL listed for use with & Series F family contactors.

9 Overload Relay Dimensions (in.) 25 (contactor mount) 25 (on individual mounting block) 36 (contactor mount) 36 (on individual mounting block) 93 (contactor mount) 93 (on individual mounting block) 200 Overload Protection Curve

10 Application & Wiring References Contactors & Overload Relays Typical Hp to FLA Conversion Chart Horse Power (Hp) 3/4 Hp 1 Hp 2 Hp 3 Hp 5 Hp 7.5 Hp 10 Hp 15 Hp 20 Hp 25 Hp 30 Hp 40 Hp 50 Hp 60 Hp 75 Hp 100 Hp 150 Hp Full Load Amps 240V 2.8 3.6 6.8 9.6 15.2 22 28 42 54 68 80 104 130 154 192 248 360 3 Phase (A) * 460V 1.4 1.8 3.4 4.8 7.6 11 14 21 27 34 40 52 65 77 96 124 180 Full Load Amps 120V 13.8 16 24 34 56 80 100 - - - - - - - - - - 1 Phase (A) 240V 6.9 8 12 17 28 40 50 - - - - - - - - - - * Values based on NEC Table 430-150 (1999) for induction type squirrel cage & wound rotor motors. Adjust for low speed, high torque and multispeed motors. Wiring Diagram for Telemecanique LC1 Contactor Replacements by US Breaker Three Phase - Wiring Diagram Fuse/ MCCB 95 96 14 13 Fuse/ MCCB Connect to other supply 95 96 14 13 Control supply voltage is the same as the main circuit voltage (3 phase) Control supply voltage is not the same as the main circuit voltage (3 phase) Single Phase - Wiring Diagram Fuse/ MCCB 95 96 14 13 Fuse/ MCCB Connect to other supply 95 96 14 13 Control supply voltage is the same as the main circuit voltage (single phase) Control supply voltage is not the same as the main circuit voltage (single phase)

11 US Breaker Contactor Cross References NC1 D09-D18 NC1 -D32 NC1 D40-D65 NC1 D80-D95 F185 3P Contactors - Allen Bradly 100, Cutler Hammer CE & General Electric CL US Breaker Price Hp ( 3-phase) Dim (in) Type Contactor Cross Reference (Similar Designs) Brand Part # Each NO NC 240V 460V (H x W x D) Allen Bradley 100-C Allen Bradley 100-A Cutler Hammer CE General Electric CL 0910 - V $12.48 1 0 3 5 3.0 x 1.9 x 3.2 DIN Rail or Base Mount 100-C09*10 100-A09ND3 2) CE15ANS3 CL00 A310T 0901 - V $12.48 0 1 3 5 3.0 x 1.9 x 3.2 100-C09*01 - - CL00 A301T 1210 - V $16.19 1 0 5 7.5 3.0 x 1.9 x 3.2 100-C12*10 100-A12ND3 2) CE15GNS3 / CE15CNS3 CL01 A310T 1201 - V $16.19 0 1 5 7.5 3.0 x 1.9 x 3.2 100-C12*01 - - CL01 A301T 1810 - V $20.65 1 0 7.5 10 3.0 x 1.9 x 3.4 100-C16*10 100-A18ND3 2) CE15DNS3 CL02 A310T 1801 - V $20.65 0 1 7.5 10 3.0 x 1.9 x 3.4 100-C16*01 - - CL02 A301T 2510 - V $24.94 1 0 10 15 3.4 x 2.2 x 3.7 100-C23*10 100-A24ND3 2) CE15ENS3 CL25 A310T 2501 - V $24.94 0 1 10 15 3.4 x 2.2 x 3.7 100-C23*01 - - CL25 A301T 3210 - V $33.96 1 0 15 20 3.4 x 2.2 x 3.9 100-C30*10 100-A30N*3 CE15FNS3 CL04 A310M 4011 - V $41.88 1 1 20 25 5.1 x 3.0 x 4.6 100-C37*00 (or *10) 100-A38N*3 CE15GNS3 CL45 A310M 5011 - V $52.69 1 1 20 30 5.1 x 3.0 x 4.6 100-C43*00 (or *10) 100-A45N*3 CE15HNS3 CL06 A311M 6511 - V $59.96 1 1 25 40 5.1 x 3.0 x 4.6 100-C60*00 (or *10) 100-A60N*3 CE15JNS3 CL07 A311M 8011 - V $68.49 1 1 30 40 5.1 x 3.4 x 5.0 100-C72*00 (or *10) 100-A75N*3 CE15KNS3 CL08 A311M 9511 - V $78.88 1 1 30 50 5.1 x 3.4 x 5.0 100-C85*00 (or *10) - CE15LN3 CL09 A311M F115 P3 V $139.00 - - 40 75 6.4 x 6.6 x 6.8 Base Mount 100-D115 100-B110N*3 1) CE15MN3 1,3) - F150 P3 V $219.00 - - 50 100 6.7 x 6.6 x 6.8 100-D140 - CE15NN3 1,3) CK75CE311 1) F185 P3 V $298.00 - - 60 100 6.9 x 6.7 x 7.2-100-D180 100-B180N*3 1) CE15PN3 1,3) CK08CE311 1) F265 P3 V $349.00 - - 100 150 8.0 x 8.0 x 8.5 100-D210 or 100-0 100-B250N*3 1) CE15RN3 1,3) CK09BE311 1) Insert the AC control coil voltage of 24, 120 or 240 (example: 0910-V120 replaces Allen Bradley s 100-C09*10 with a 120V control coil) US Breaker Price Hp ( 3-phase) Dim (in) 3P Contactors - Telemecanique LC1 & Siemens 3TF Type Contactor Cross Reference (Similar Designs) Brand Part # Each NO NC 240V 460V (H x W x D) Telemecanique LC1 Telemecanique LC1 Telemecanique LC1 Siemens 3TF 0910 - V $12.48 1 0 3 5 3.0 x 1.9 x 3.2 DIN Rail or Base Mount LC1D09 1) LC1 D09 10 LC1-D093. A65 3TF40 10-0A 0901 - V $12.48 0 1 3 5 3.0 x 1.9 x 3.2 - LC1 D09 01 LC1-D099. A65 3TF40 01-0A 1210 - V $16.19 1 0 5 7.5 3.0 x 1.9 x 3.2 LC1 1) LC1 10 LC1-3. A65 3TF41 10-0A 1201 - V $16.19 0 1 5 7.5 3.0 x 1.9 x 3.2 - LC1 01 LC1-9. A65 3TF41 01-0A 1810 - V $20.65 1 0 7.5 10 3.0 x 1.9 x 3.4 LC1D18 1) LC1 D18 10 LC1-D173. A65 3TF42 10-0A 1801 - V $20.65 0 1 7.5 10 3.0 x 1.9 x 3.4 - LC1 D18 01 LC1-D179. A65 3TF42 01-0A 2510 - V $24.94 1 0 10 15 3.4 x 2.2 x 3.7 LC1 1) LC1 10 LC1-3. A65 3TF43 10-0A 2501 - V $24.94 0 1 10 15 3.4 x 2.2 x 3.7 - LC1 01 LC1-9. A65 3TF43 01-0A 3210 - V $33.96 1 0 15 20 3.4 x 2.2 x 3.9 LC1D32 1) LC1 D32 10 LC1-D323. A65 3TF44 11-0A 1) 4011 - V $41.88 1 1 20 25 5.1 x 3.0 x 4.6 LC1 D40 LC1 D4011 LC1-D403 3TF45 11-0A 5011 - V $52.69 1 1 20 30 5.1 x 3.0 x 4.6 LC1 D50 LC1 D5011 LC1-D503 3TF46 11-0A 6511 - V $59.96 1 1 25 40 5.1 x 3.0 x 4.6 LC1 D65 LC1 D6511 LC1-D633 3TF47 11-0A 8011 - V $68.49 1 1 30 40 5.1 x 3.4 x 5.0 LC1 D80 LC1 D8011 LC1-D803-9511 - V $78.88 1 1 30 50 5.1 x 3.4 x 5.0 LC1 D95 LC1 D9511-3TF48 11-0A F115 P3 V $139.00 - - 40 75 6.4 x 6.6 x 6.8 Base Mount LC1F115 LC1F115 LC1FF43 3TF50 1,3) F150 P3 V $219.00 - - 50 100 6.7 x 6.6 x 6.8 LC1F150 LC1F150-3TF51 1) F185 P3 V $298.00 - - 60 100 6.9 x 6.7 x 7.2 LC1F185 LC1F185 LC1FG43 3TF52 1) F265 P3 V $349.00 - - 100 150 8.0 x 8.0 x 8.5 LC1F265 LC1F265 LC1FH43 3TF53 1) Insert the AC control coil voltage of 24, 120 or 240 (example: 0910-V120 replaces Telemecanique s LC1D0910 with a 120V control coil) 1) Add an additional NC-F4-11 for cross references to the Telemanique LC1 D09 thru LC1 D32 or Siemens 3TF44 11-0A if the Normally Closed auxiliary contact is used. Add an additional NC-F4-11 or NC-F4-22 if auxiliary contacts are required for cross references to US Breaker s F115 thru F265 contactors. 2) Allen Bradley 100-A09 thru -A24 include a fully rated 4th pole. US Breaker s cross ref includes a standard auxiliary rated contact. See the 1204 or 2504 for a fully rated 4th pole. 3) US Breaker F115 - F265 contactors are supplied with bus extensions (without lugs) as standard.