Piezoceramic Ultrasound Transducer Enabling Broadband Transmission for 3D Scene Analysis in Air

Similar documents
Transducer product selector

A 3D ultrasonic positioning system with high accuracy for indoor application

19 th INTERNATIONAL CONGRESS ON ACOUSTICS MADRID, 2-7 SEPTEMBER 2007

Range Sensing strategies

Chapters 1 & 2. Definitions and applications Conceptual basis of photogrammetric processing

15-2 Nan-ei-cho, Tottori-shi JAPAN TEL FAX URL

Keywords: Ultrasonic Testing (UT), Air-coupled, Contact-free, Bond, Weld, Composites

Preparation of arc broadband piezoelectric composite vibrator and its transducer array

CIRCULAR PHASED ARRAY PROBES FOR INSPECTION OF SUPERPHOENIX STEAM GENERATOR TUBES

Veröffentlichungen am IKFF PIEZOELECTRIC TRAVELLING WAVE MOTORS GENERATING DIRECT LINEAR MOTION

Operation and Sound Field of an Ultrasonic Biplane-Array

ACOUSTO-ULTRASONIC EVALUATION OF HYBRID COMPOSITES USING

Properties of Interdigital Transducers for Lamb-Wave Based SHM Systems

Proceedings of Meetings on Acoustics

Received signal. (b) wide beam width. (a) narrow beam width. (a) narrow. Time. (b) wide. Virtual sonar ring. Reflector.

80 khz Cylindrical Ultrasound Transducer

Multi-Element Array Antennas for Free-Space Optical Communication

Optimization of Ultrasound Broadband Transducers for Complex Testing Problems by Means of Transient and Time Harmonic Sound Fields

ULTRASONIC GUIDED WAVE ANNULAR ARRAY TRANSDUCERS FOR STRUCTURAL HEALTH MONITORING

Design and realization of tracking feed antenna system

Generation Laser Scanning Method for Visualizing Ultrasonic Waves Propagating on a 3-D Object

Active Vibration Control in Ultrasonic Wire Bonding Improving Bondability on Demanding Surfaces

Selective Excitation of Lamb Wave Modes in Thin Aluminium Plates using Bonded Piezoceramics: Fem Modelling and Measurements

IMAGING OF DEFECTS IN CONCRETE COMPONENTS WITH NON-CONTACT ULTRASONIC TESTING W. Hillger, DLR and Ing. Büro Dr. Hillger, Braunschweig, Germany

A PILOT STUDY ON ULTRASONIC SENSOR-BASED MEASURE- MENT OF HEAD MOVEMENT

Performance Simulation and Fabrication of PZT Piezoelectric Composite Ring

SINGLE-FEEDING CIRCULARLY POLARIZED TM 21 - MODE ANNULAR-RING MICROSTRIP ANTENNA FOR MOBILE SATELLITE COMMUNICATION

A Spiral Antenna with Integrated Parallel-Plane Feeding Structure

Reconfigurable Arrays for Portable Ultrasound

Chapter 30: Principles of Active Vibration Control: Piezoelectric Accelerometers

Lamb Wave Ultrasonic Stylus

Rotary Encoder System Compact Model Range

An Overview Algorithm to Minimise Side Lobes for 2D Circular Phased Array

Ultrasonic Indoor positioning for umpteen static and mobile devices

IPC TECHNICAL PAPER SERIES NUMBER 310

Extending Acoustic Microscopy for Comprehensive Failure Analysis Applications

Performance Analysis of Different Ultra Wideband Planar Monopole Antennas as EMI sensors

Geometric Tolerancing

Isolation Scanner. Advanced evaluation of wellbore integrity

NONDESTRUCTIVE EVALUATION OF CLOSED CRACKS USING AN ULTRASONIC TRANSIT TIMING METHOD J. Takatsubo 1, H. Tsuda 1, B. Wang 1

Understanding How Frequency, Beam Patterns of Transducers, and Reflection Characteristics of Targets Affect the Performance of Ultrasonic Sensors

DEEP PENETRATING EDDY CURRENT for DETECTING VOIDS in COPPER

Multi-spectral acoustical imaging

Tadeusz Stepinski and Bengt Vagnhammar, Uppsala University, Signals and Systems, Box 528, SE Uppsala, Sweden

Identification of Delamination Damages in Concrete Structures Using Impact Response of Delaminated Concrete Section

Standard Guide for Evaluating Characteristics of Ultrasonic Search Units 1

High contrast air-coupled acoustic imaging with zero group velocity Lamb modes

ENHANCEMENT OF SYNTHETIC APERTURE FOCUSING TECHNIQUE (SAFT) BY ADVANCED SIGNAL PROCESSING

Further development of synthetic aperture real-time 3D scanning with a rotating phased array

Chapter 5 DESIGN AND IMPLEMENTATION OF SWASTIKA-SHAPED FREQUENCY RECONFIGURABLE ANTENNA ON FR4 SUBSTRATE

The Development of Laser Ultrasonic Visualization Equipment and its Application in Nondestructive Inspection

Lab 2. Logistics & Travel. Installing all the packages. Makeup class Recorded class Class time to work on lab Remote class

SPARSE ARRAY TOMOGRAPHY SYSTEM FOR CORROSION EXTENT MONITORING H. Bian, H. Gao, J. Rose Pennsylvania State University, University Park, PA, USA

Broadband Constant Beamwidth Beamforming MEMS Acoustical Sensors

Ihor TROTS, Andrzej NOWICKI, Marcin LEWANDOWSKI

ACOUSTIC MICRO IMAGING ANALYSIS METHODS FOR 3D PACKAGES

Geometry. ELG HS.G.14: Visualize relationships between two-dimensional and three-dimensional objects.

Novel Electrically Small Spherical Electric Dipole Antenna

INSPECTION OF THERMAL BARRIERS OF PRIMARY PUMPS WITH PHASED ARRAY PROBE AND PIEZOCOMPOSITE TECHNOLOGY

360. A method for air flow measurement using high frequency vibrations

CIRCULAR DUAL-POLARISED WIDEBAND ARRAYS FOR DIRECTION FINDING

Spectral Distance Amplitude Control for Ultrasonic Inspection of Composite Components

POCKET DEFORMABLE MIRROR FOR ADAPTIVE OPTICS APPLICATIONS

The Design of a Transmitter with a Parabolic Conical Reflector for a Sonar Ring

SUPPLEMENTARY INFORMATION

Acoustic Resonance Analysis Using FEM and Laser Scanning For Defect Characterization in In-Process NDT

Radiation Performance of an Elliptical Patch Antenna with Three Orthogonal Sector Slots

Sonic Distance Sensors

RECENT applications of high-speed magnetic tracking

Lesson 02: Sound Wave Production. This lesson contains 24 slides plus 11 multiple-choice questions.

Answers to Questions and Problems

EQUIVALENT THROAT TECHNOLOGY

Radar Signatures and Relations to Radar Cross Section. Mr P E R Galloway. Roke Manor Research Ltd, Romsey, Hampshire, United Kingdom

ACOUSTIC EMISSION MEASUREMENTS ON SHELL STRUCTURES WITH DIRECTLY ATTACHED PIEZO-CERAMIC

Theory and Applications of Frequency Domain Laser Ultrasonics

DISTRIBUTED FLEXIBLE TACTILE SENSOR USING PIEZOELECTRIC FILM. Kee-Ho Yu, Tae-Gyu Kwon, Myung-Jong Yun and Seong-Cheol Lee

Medical Imaging (EL582/BE620/GA4426)

TechNote. T001 // Precise non-contact displacement sensors. Introduction

PRIME FOCUS FEEDS FOR THE COMPACT RANGE

ULTRASONIC IMAGING of COPPER MATERIAL USING HARMONIC COMPONENTS

Proceedings of Meetings on Acoustics

Miniaturising Motion Energy Harvesters: Limits and Ways Around Them

Proceedings of Meetings on Acoustics

PARAMETERS THAT INFLUENCE THE ULTRASONIC BOND QUALITY

Ultrasound Beamforming and Image Formation. Jeremy J. Dahl

Ripple and Uniformity Measurement of a Phased-Array Testing-Machine for round-bar Testing

E X P E R I M E N T 12

High Frequency Ultrasonic Systems with Frequency Ranges of 35 to 200 MHz

Challenges and New Developments for Air Coupled Ultrasonic Imaging

Automatic Testing of Photonics Components

Abstract. 1 Introduction. 1.2 Concept. 1.1 Problematic. 1.3 Modelling

Guided Wave Travel Time Tomography for Bends

Ultrasonic Guided Wave Testing of Cylindrical Bars

Ultrasound Redefined. Ultrasonic Transducers

Nondestructive Testing and Flaw Detection in Steel block Using extension of Split Spectrum Processing based on Chebyshev IIR filter

Lateralisation of multiple sound sources by the auditory system

Ginzton Laboratory, W. W. Hansen Laboratories of Physics Stanford University, Stanford, CA 94305

Effect of Open Stub Slots for Enhancing the Bandwidth of Rectangular Microstrip Antenna

NELA Brüder Neumeister GmbH

Design, Development and Characterization of. Wideband Polymer Ultrasonic Probes. for Medical Ultrasound Applications. A Thesis

Transcription:

A2.2 Piezoceramic Ultrasound Transducer Enabling Broadband Transmission for 3D Scene Analysis in Air Kellner Johannes, Schweinzer Herbert Institute of Electrical Measurements and Circuit Design, Vienna University of Technology Gusshausstrasse 25/354, 1040 Vienna, Austria Abstract Frequency-modulated ultrasound signals like chirp-signals show variations in phase at the different transmission angles. Analyzing the phase of ultrasound chirp-echoes enables to accurately determine distance and polar angle to the point of reflection. Though single piezoceramic ultrasound transducers have a small bandwidth, an ultrasound transducer made of a combination of piezoceramic elements with different resonance frequencies as presented in this work enables transmission of broadband chirpsignals and shows the required rotational symmetry. 1 Introduction Ultrasound transducers play an important role in imaging under water, medical imaging and nondestructive material testing (NDT). Though air ultrasound systems are found in several fields, e. g. for gas flow measurements, robot navigation and fill level measurements, they won only in car industry importance applied as parking help. Air ultrasound systems have the advantage that distances to reflecting objects can be measured in dusty, dirty or smoky environments [8], where optical sensors would fail. In literature different kinds of ultrasound 3D positioning and scene analysis systems can be found using A-B measurements (receiver placed on the object whose position is of interest) [1, 2], others use reflective measurements [3], but all use only the time of flight (TOF) information of the ultrasound signals. Our group is researching the phase information of echo signals coming from reflecting objects. Frequency-modulated chirp-signals transmitted by ultrasound sensors with broad bandwidth show different variations in phase at different directions of the radiated sound pattern. With the phase information of the echo signal it is possible to determine the angle of the point of reflection with respect to the main transmission direction of the ultrasound transducer, representing the polar angle in a spherical coordinate system with the main transmission direction being the z axis. Processing the frequency-modulated chirp-signal by use of a correlation algorithm delivers high accuracy of the distance measurement. Using only one ultrasound transducer transmitting a broadband signal and assuming rotational symmetry, we get the distance and one of the two angles needed to exactly determine the 3D coordinates of the reflection point, instead of getting only the distance like in other known systems. Off the shelf ultrasound transducers for air applications are based on different technologies, like electrostatic transducers, PVDF (Polyvinylidene fluoride) transducers, piezoceramic and piezocomposite transducers. Although typical constructions of electrostatic transducers are not well suited for industrial environment, many air ultrasound applications are based on this transducer type producing high sound pressure amplitudes by simultaneous small power consumption. Though electrostatic transducers have also an advantageous broad bandwidth, they are not appropriate to be used for polar angle measurements, because they still cannot be produced with a good rotational symmetry. The only air ultrasound transducers that show appropriate rotational symmetry are piezoceramic transducers. Piezoceramic transducers have a narrow bandwidth and are driven most effectively at their geometry-dependent resonance frequencies. Our idea to arrange piezoceramic components with different resonance frequencies in a transducer [4, 5, 6] leads to two innovative advantages. On the one hand, a transmission of broadband signals having reproducible rotational transmission symmetry is enabled, on the other hand an activation of every single element of the ultrasound transducers transmitting surface can be controlled by simply changing the driving frequency, which leads to frequency controlled radiation patterns and increased changes of the transmission angle dependent signal phases and therefore to a better angle detectability by echo signal processing. SENSOR+TEST Conference 2009 - SENSOR 2009 Proceedings I 53

2 Three Ring Annular Design The piezoceramic components are bonded to each other using soft silicone rubber (GE silicones RTV12), which on the one hand adheres well on the components and on the other hand mechanically decouples the single piezoceramic components. Various designs of combined piezoceramic components are imaginable. Some were already analyzed using simulation models. A few prototypes were built and their vibration and transmission behaviour investigated. The transducer studied in this paper is shown in Fig. 1 and consists of three interleaved piezoceramic annular rings made of soft-pzt PIC151 from PI Ceramic GmbH, Germany. The rings were manufactured at our institute by grinding piezoceramic bulk material. The radial geometric dimensions (outer diameter, inner diameter) of the piezoceramic rings were a compromise between necessary transmitting surface and a maximum of wanted overall dimensions of the transducer configuration. The length dimensions of the rings were fitted to get uniformly distributed resonance frequencies in a range from 74kHz to 92kHz (see Table 1). The upper frequency bound is given by the maximum frequency of the separated receiver microphone (see later in this work) and the lower frequency bound results of not wanting to much distance between the single resonance peaks (see Fig. 2). Table 1. Geometrical dimensions and resonance frequencies of the piezoceramic rings Outer diameter Inner diameter Length Resonance frequency Ring 1 16.1mm 5.3mm 16.8mm 74kHz Ring 2 25.8mm 18.1mm 19.3mm 83kHz Ring 3 35mm 23mm 16.5mm 92kHz The transmitting areas of all three piezoceramic rings build a plane and are contacted with silver ink electrodes, as well as their opposite sides. In the centered hole of Ring 1, the separated receiver microphone is installed (see Fig. 5.b) again using silicone rubber as filling material to mechanically decouple the microphone from Ring 1. Figure 2 shows the sound pressure spectrums of the three rings measured at a driving voltage of 300Vpp. in a distance of 0.5m in main transmission direction. 3 Measuring Signal For both, measuring accurate distances as well as measuring the polar angle of reflecting points, chirp-signals with linearly increasing frequency are used. The bandwidth of the transducer configuration enables an effectively transmission of chirp-signals with frequencies from 68kHz to 108kHz. The transmitted ultrasound signal results of the superposition of portions of the chirp-signal radiated from each of the three piezoceramic rings. A transmitted chirp-signal with duration of 0.5ms is shown in Fig.3. Fig. 1. Air ultrasound transducer consisting of three interleaved piezoceramic rings, each having another resonance frequency, bonded together with soft silicone rubber. Fig. 2. Sound pressure spectrums of the 3 piezoceramic rings at 300Vpp driving voltage, measured in a distance of 0.5m. 54 SENSOR+TEST Conference 2009 - SENSOR 2009 Proceedings I

Fig. 3. Transmitted chirp-signal. Linearly increasing frequency from 68kHz to 108kHz. Duration 0.5ms. It can be seen, that the envelope of the transmitted signal proceeds according to the resonance peaks of the three piezoceramic rings. 4 Measuring Method and Rotational Symmetry Immediately after transmitting a chirp-signal, the separated receiver microphone is enabled scanning for echoes. Once an echo is detected, the echo signal is correlated with reference signals, each reference signal according to another polar angle. The highest correlation result is scored when the echo signal is correlated with a reference signal of that polar angle that fits the angle, the echo is coming from. The accurate distance to the point of reflection is determined in parallel with the results of the polar angle measurements. Applying this method, the polar angle detectability was analyzed at azimuth angles stepwise from 0 to 330 (angle steps 30 ). Fig. 4 shows the result of the rotational symmetry analysis. Fig. 4. Analyzing rotational symmetry of the polar angle dependent phase information stepwise from 0 to 330. Errors in the larger polar angles are caused by low SNR. When measuring the polar angle, errors occur mainly at angles larger than 20 where signal-tonoise-ratio (SNR) is significantly lower than in main direction. SENSOR+TEST Conference 2009 - SENSOR 2009 Proceedings I 55

5 Measuring position and orientation of a 30mm diameter rod The annular transducer with the separated centered receiver microphone (= annular sensor) was mounted on a 2-axes-wrist / linear drive combination (PowerCube robot device) as can be seen in Fig.5. a) b) Fig. 5. a,b) Annular transducer with separated receiver microphone mounted on a PowerCube robot device (2- axes-wrist-manipulator combined with a linear drive). First practical application of the annular transducer was measuring distance and polar angle to reflecting objects. This robot device was used to move the annular sensor in the room, measuring distances and polar angles to reflecting points, all lying on a round rod with a diameter of 30mm (see Fig. 6). Fig. 6. Annular sensor while moving through the room and measuring reflections of a round rod. Knowing the polar angle of the reflection point means in other words, that all possible echo rays form a cone symmetrically positioned in the direction of the sensor axis. Thus, together with the measured distance, all possible reflection points form a circle symmetrically positioned around the sensor axis (see Fig. 7). The orientation of this circle is determined by the sensor axis. Its position is determined by the measured distance between reflection point and transducers transmitting surface. The radius is given from the opening angle of the cone which is the measured polar angle. The measuring results are fully spatially determined contact circles. 56 SENSOR+TEST Conference 2009 - SENSOR 2009 Proceedings I

a) Rod nearly in parallel to the axis of the linear drive. In the first measuring scene, the sensor was moved along the linear drive nearly in parallel to the axis of the round rod. Fig. 7 shows the measured contact circles of reflecting points of the rod at 11 measuring positions with distances of 30mm between each position. Fig. 7. Measuring scene 1. Sensor moved along linear drive axis measuring distances and polar angles to a round rod positioned nearly in parallel to the linear drive axis. In the list of measuring results where r is the measured distance between sensor and reflection point on the rod, and theta is the measured polar angle to the reflection point, it can be seen that the rod axis and the moving axis of the sensor are not perfectly in parallel, because of the descending distance values in the measuring results. b) Rod not in parallel to the axis of the linear drive In the second measuring scene, the rod was lying diagonally in the room with respect to the linear drive axis. The sensor was again moved along the linear drive. At 31 positions with 10mm space between each position the distances r and polar angles theta to the round rod were measured delivering the results for the contact circles shown in Fig. 8. Measuring results [r,theta]=[464.6mm, 6 ] [r,theta]=[464mm, 6 ] [r,theta]=[463.5mm, 5 ] [r,theta]=[462.9mm, 5 ] [r,theta]=[462.4mm, 4 ] [r,theta]=[462.1mm, 4 ] [r,theta]=[461.5mm, 3 ] [r,theta]=[461mm, 3 ] [r,theta]=[460.6mm, 2 ] [r,theta]=[460.3mm, 2 ] [r,theta]=[459.9mm, 2 ] [r,theta]=[459.7mm, 1 ] [r,theta]=[459.6mm, 1 ] [r,theta]=[459.5mm, 1 ] [r,theta]=[459.3mm, 2 ] [r,theta]=[459mm, 2 ] [r,theta]=[458.9mm, 2 ] [r,theta]=[458.8mm, 3 ] [r,theta]=[458.7mm, 3 ] [r,theta]=[458.6mm, 3 ] [r,theta]=[458.9mm, 4 ] [r,theta]=[459mm, 5 ] [r,theta]=[459.2mm, 5 ] [r,theta]=[459.2mm, 6 ] [r,theta]=[459.4mm, 6 ] [r,theta]=[459.7mm, 6 ] [r,theta]=[460mm, 7 ] [r,theta]=[460.2mm, 8 ] [r,theta]=[460.6mm, 8 ] [r,theta]=[461mm, 9 ] [r,theta]=[461.5mm, 9 ] Fig. 8. Measuring scene 2. Sensor moved along linear drive axis measuring distances and polar angles to a round rod positioned diagonally in the room with respect to the linear drive axis. SENSOR+TEST Conference 2009 - SENSOR 2009 Proceedings I 57

In [7] it was shown that orientation and position of an edge can be fully spatially determined measuring polar angle and distance of two reflection points lying on the edge. In principle, measuring may be performed at two arbitrary sensor positions. The algorithm in [7] is based on the knowledge that the reflection points lie on one edge. A round rod in the room being the only reflective object, acts like an edge where again position and orientation can be calculated using the algorithms of [7] after measuring distance and polar angle of at least two reflection points lying on the rod. Ambiguous solutions of determined position and orientation of the rod can be avoided, when the sensor is moved in paths that deviate from straight lines. Measuring distance and angle of more than two reflection points leads to an overestimated system of equations helping to lower the failure possibility and to classify the measured object with respect to its type. 6 Conclusion Though piezoceramic transducers have a narrow bandwidth, a combination of piezoceramic components with different resonance frequencies building one ultrasound sensor as presented in this work, allow the transmission of broadband signals like chirp-signals that can be used to accurately measure distances and polar angles to reflecting objects. Former problems of measuring polar angles in air like low accuracy when using amplitude information [7] or small detectable angle areas are not given using a transducer configuration like presented in this work. References [1] Mahajan, A., Walworth, M., 3D Position Sensing Using the Differences in the Time-of-Flights from a Wave Source to Various Receivers. IEEE Trans. Robot. Autom., Vol. 17, No. 1, Feb. 2001, pp. 91-94. [2] Dijk, E. O., (Kees) van Berkel, C. H., Aarts, R. M., van Loenen, E. J., 3-D Indoor Positioning Method using a Single Compact Base Station. Proc. IEEE PERCOM 04, 2004, pp. 101-110. [3] Capineri, L., Fiorillo, A. S., Rocchi, S., Low Frequency PVDF Transducers for 3D Object Profiling in Air. Proc. IEEE Ultrason. Symp. 1995, pp. 901-904. [4] Kellner, J., Schweinzer, H., Piezoceramic Ultrasonic Transducer with Frequency Controlled Radiation Pattern. Proc. IEEE Instr. & Meas. Techn. Conf., 2007. [5] Kellner, J., Schweinzer, H., 1-3 Piezofiber - Silicone Rubber - Composite with Different Resonance Frequencies Enabling Frequency Controlled Shapes of the Ultrasound Radiation Pattern. Proc. IEEE Ultrason. Symp. 2007, pp. 1701-1704. [6] Kellner, J., Schweinzer, H., Broadband Piezoceramic Ultrasound Transducers for 3D Scene Analysis in Air. Tagungsband zur Informationstagung Mikroelektronik 08 (ME2008), Wien, 2008, pp. 73-77. [7] Krammer, P., Spatial Localization of Elementary Geometric Shapes with Industrial Ultrasonic Sensors. Dissertation, Institute of Electrical Measurements and Circuit Design, Vienna University of Technology, 2005. [8] Mágori, V., Ultrasonic Sensors in Air. Proc. IEEE Ultrason. Symp. 1994, pp. 471-481. 58 SENSOR+TEST Conference 2009 - SENSOR 2009 Proceedings I