Far-field measurements with RIGO801 near-field goniophotometers

Similar documents
RIGO 801 NEAR-FIELD GONIOPHOTOMETER

RIGO V NEAR-FIELD GONIOPHOTOMETER

IESNA LM Test Report

IESNA LM Test Report

Lighting Terminologies Introduction

NFMS THEORY LIGHT AND COLOR MEASUREMENTS AND THE CCD-BASED GONIOPHOTOMETER. Presented by: January, 2015 S E E T H E D I F F E R E N C E

Measuring the luminance distribution and horizontal illumination on the airports apron. Canon 70D (DSLR) SIGMA 4.5mm/2.8 EX DC Circular Fisheye

MEASUREMENT OF THE THRESHOLD INCREMENT (TI) IN ROAD LIGHTING BASED ON USING ILMD

Excellent light measurement technology

RiGO Specification

We bring quality to light. MAS 40 Mini-Array Spectrometer

BGS400 Lamp & Luminaire Goniophotometer (C-γ, B-ß Plane)

Electrical Illumination and Design

Electrical Installation LectureNo.10 Dr.Mohammed Tawfeeq Al-Zuhairi. Luminous flux Luminous intensity Illuminance Luminance

Company synopsis. Regulations and Standards

Partial Flux - Measurement Reliability of Lensed LEDs Application Note

Imaging Photometer and Colorimeter

Report No.: EASZE Page 2 of 14

daylight Spring 2014 College of Architecture, Texas Tech University 1

Light is new defined Scriptus The innovative luminaire range for offices and public buildings.

Luminous Flux (lumens) System LM-ISP-XXXX

Rückwardt, Matthias; Göpfert, André; Rosenberger, Maik; Linß, Gerhard; Kienast, Sascha:

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006

Photometry for Traffic Engineers...

Miniaturized Spectroradiometer

Industrial Engineering and Ergonomics

Wolf, Stefan; Gall, Dietrich : Luminance Analysers - What they are and how do they work

TEST REPORT. Job No SHA Date: Apr 12,2017 REPORT NO SHA-006. TEST OF ONE LED Luminaire MODEL NO.

LGS Goniophotometer. Two Global Leaders. One Complete Solution.

Industrial Engineering and Ergonomics

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary

We bring quality to light. CAS 120 CCD Array Spectrometer

71332 LED Dusk To Dawn (Area Light)



57-100W-XXK-WPH12-SG W-40K-WPH12-SG W-57K-WPH12-SG

Pedestrian Crossing - 2 lanes with traffic island

Cat# LED Wall-PACK

Current and Future Realizations NRC Photometric and Spectroradiometric Calibration Chains

Test Report. Report Number: L14070 Date: Oct 9, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727

Pedestrian Crossing - 2 lanes

Report No.: HZ c/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Photometry and Light Measurement

LED Slim Panel 48 W PRODUCT DATA SHEET

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary

Eternal Shine Technology Co.,Ltd. EST

Light is easy to upgrade Siteco DUS LED.

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Mayer Tunnel Lighting Control System

NVLAP LAB CODE LM Test Report. For. Maxlite INC. (Brand Name: Maxlite) 12 York Ave., West Caldwell, NJ 07006

LIMES 2000 Release Notes



The Art of Light Measurement. Avantes BV Apeldoorn, The Netherlands

Work environment. Retina anatomy. A human eyeball is like a simple camera! The way of vision signal. Directional sensitivity. Lighting.

BTS2048-VL-CP-ILED-B-IS-1.0-HL

Spectroradiometer specbos 1201

RoHS QPL ID # PLC6V1PABNUJS

RoHS. Dimming: PWM/VR/0-10V QPL ID # PL21D5Q1B95E. Cat# W FlatPanel Pole Mount. EPA Rating 2.33ft 2.

Multispectral. imaging device. ADVANCED LIGHT ANALYSIS by. Most accurate homogeneity MeasureMent of spectral radiance. UMasterMS1 & UMasterMS2

Report No.: HZ h/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

VAC 60HZ A 120V; 0..18A 277V 40W PF ,000 LM 125 LM/W >82 <19. Arcata VDC 1.2A 120V 88% Edison

Light is impressive Siteco Vega The designer range of LED luminaires for professional office lighting.

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

LED Floodlight. RoHS. Model: inner box: L 17" X W 12.5" X H 9.33" 1PCS AC 50/60HZ. Input Voltage 0.85A MAX. Input Current 78 W.

1X4 LED Panel Light RoHS 0-10V Dimmable QPL ID #

Lighting Sciences

RoHS QPL ID # P9JSE2P8. Cat# Watts Trunion Mount. Model: master carton: L*W*Hmm 1PCS. EPA Rating 1.

Photometric Test Report

Sample Report. IES LM Test Report. LED Lamp 001. Test results reported for: Orb Optronix report: LEDC WG. Original issue date:

INDEPENDENT TEST LABORATORY REPORT No

INDEPENDENT TEST LABORATORY REPORT No

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

ORE Lighting INC Type3-Medium. SV-LLD240W / Luminaire Data Sheet

NVLAP LAB CODE LM Test Report. For. Maxlite Inc. (Brand Name: ) 12 York Avenue, West Caldwell, NJ

Light is impressive Siteco Vega

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Lighting Sciences, Inc.

SIGMA 18-50mm F2.8 EX DC Macro (incl. lens hood and dust cover) Mobility case Samsonite + carrying strap Transport case TechnoTeam

robogonio Quick. Precise. Highly flexible.

LM Test Report. for Maxlite Inc. LED Canopy Model: MLCAN20LED50


Report No.: HZ j. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Test Report. Report Number: L15033 Date: Mar 24, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727

Report No.: HZ f. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

LIGHT AND HEALTH IN FACTORY WORK PLACES

LM Test Report. for Maxlite SK America Inc. WALLPACK Model: MLSWP30LED50DS

Test Report. Report No.: EED35I Page 1 of 10. Customer : EIKO GLOBAL LLC Address : W 84TH ST SHAWNEE, KS USA

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

STREET SETA. Properties. Specifications. Application. Tel

TOP 200. Telescopic Optical Probe for Radiance and Luminance Measurements. Two Global Leaders. One Complete Solution.

Guidance Note 3/16 Measurement of the photometric performance of LED lighting

Catalog number Lens Option Very Narrow without diffuser Exterior200LED_VeryNarrow_withoutdiffuser_5600Kelvin.ies

Cat# 71426A LED Wall-PACK QPL ID # PLO3JLI4OV69

Broadbandradiometer specbos 1211

CAS 120. CCD Array Spectrometer. Two Global Leaders. One Complete Solution.

Observational Astronomy

Dimming: PWM/TIME/0-5V/0-10V. RoHS

Transcription:

Far-field measurements with RIGO801 near-field goniophotometers

Introduction TechnoTeam Bildverarbeitung GmbH Werner-von-Siemens-Straße 5 98693 Ilmenau Germany http://www.technoteam.de Knut Bredemeier Developing Engineer Near-field goniophotometer knut.bredemeier@technoteam.de Page 2

1. Basic principles Far-Field measurement Illuminances measured at a large distance to the light source are directly calculated (approximation) to luminous intensities Luminous flux can be calculated from the luminous intensity distribution or by calculating the integral of the measured illuminances Near-Field measurement Luminance images are captured around the light source by using a luminance measuring camera The luminance images are transformed to ray sets that can easily be calculated to the luminous intensity distribution (LID) Luminous flux can be determined on the basis of the measured luminance images or by calculating the integral of the measured illuminances in case of an available photometer head mounted next to the camera Page 3

2. Principle of far-field goniophometer systems Measurement of luminous intensity values using a single illuminance meter at a far field distance to the light source Error [%] r/h 0.1 0.5 1 31.6 14.1 9.95 I = E r 2 5 4.36 10 3 (Lambert radiation!) Page 4

2.1 Photometric distance law Calculation of luminous intensities from illuminances E = p L( γ 1) dω 2 [lx] For small solid angles following approximation can be done E I( γ 1) L( γ 1) Ω p2 = cosγ 2 2Ω r Small solid angles Point source Large distance 0 Photometric distance law Page 5

2.2 Rotating luminaire goniophotometer Page 6

2.3 Rotating mirror goniophotometer Page 7

2.4 Far field goniophometer advantages / disadvantages Advantages + A simple and direct measuring method Disadvantages - Rotating luminaire goniophotometer - Moved luminaire / lamp ( Instable lamp operation) Disadvantages - Rotating mirror goniophotometer - Large ( Large laboratory with complex air-conditioning system) - Expensive - Sensitive mirror - Moved luminaire / lamp (up and down -> temperature zones) - Weak sensitivity for low luminous flux light sources (e.g. single LED) Page 8

3. Principal of the RiGO801 near-field goniophometers Idea of Prof. Riemann Riemann Goniophotometer, Patent 1991 Page 9 25.03.2011 TechnoTeam Bildverarbeitung GmbH Werner-von Siemens-Str.10 98693 Ilmenau

3.1 CCD luminance measuring camera A Luminance measuring camera (CCD) is moved around the measuring object The pixels of the CCD sensor can be regarded as small single sensors (512x512 px) The area of each pixel represents a very small solid angle that measured a portion of luminous flux Far field conditions at a close distance Page 10

3.2 Calculation of ray - directions The luminous flux portion measured by a pixel is represented as a vector With the exact knowledge of the optical imaging system (lens) the vector direction for each pixel can be calculated precisely Page 11

3.3 Calculation of ray amplitudes The camera measures luminance values of each pixel L( x', y') [cd/m²] Weighting with the corresponding solid angles Ω( x', y' ) [sr] Luminous flux portions Φ( x', y' ) [lm] Calculation of direction and amplitude for each pixel Ray bundle for each image Ray bundles of all images Complete ray set Φ( x, y, z, ϑ, ϕ) Complete description of light output characteristic Page 12

3.4 Far-field luminous intensity distribution from ray sets All rays are accumulated in direction cells (standard algorithm) Luminance intensity distribution 90 cd/klm I( ϑ, ϕ)] 90 I ( ϑ, ϕ)] 75 75 60 200 60 45 300 45 30 15 0 15 30 C0-C180 C90-C270 I ( ϑ, ϕ)] Page 13

3.5 Luminous flux measurement using the photometer RiGO801 goniophotometers use an additional illuminance meter Robust method to measure the luminous flux by integration of illuminance values on a closed surface around the object Φ = EdA [lm] Also Photometer based LID measurements of small objects Simple calibration procedure by measuring a luminous flux standard lamp Page 14

3.6 Advantages of RiGO 801 Relative small and lightweight construction No extra large laboratories required Measuring object is not moved Stable conditions of light output Hanging and upstanding support Easy measurement of direct indirect luminaires Fast measurements e.g. 25 minutes for 2.5 x 2.5 ) High resolution Up to 0.1 x 0.1 possible Easy alignment of the light source by using the camera Position independent measurement by principle No need to consider the light centroid Luminance measuring camera Luminance images can be used for different tasks Cost-efficient regarding to conventional goniophotometers Page 15

3.7 RiGO801 and the standards DIN 5032-1, Part 1: Photometrical methods The type of movement (movement on a virtual spherical surface) is mentioned DIN EN 13032-1 (Partial replacement of DIN 5032-1) Measurement of luminous intensity by integrating luminances mentioned Work in the technical committee FNL-3 (DIN), Dr. Schmidt Luminance measurement and near field goniophotometer Work in CIE committee (TC2-62), Dr. Krueger Technical recommendation which includes the near-field goniophotometers RiGO801 technique established at several large luminaire and lamp manufacturers Page 16

3.8 References - Ansorg GmbH Lichttechnik, DE 1 - Audi AG, DE 3 - AE Schreder GmbH, AT 1 - D. Swarovski & Co. Lichtlabor, AT 1 - Diehl Aerospace GmbH, DE 3 - Fraunhofer Institut Solare Energiesysteme,DE 4 - Fraunhofer Institute for Reliability and Microintegration, DE 3 - FH Ravensburg/Weingarten, DE 2 - Goodrich Lighting Systems, DE 1 - Heraeus Noblelight GmbH, DE 4 - Ilexa GmbH, DE 3 - KaHo Sint-Lieven, BE 1 2 3 - Karlsruher Institut für Technologie, LTI, DE 2 - KPU, Korea Polytechnic University, Seoul, KR 2 - Lehner Werkmetall GmbH, DE 1 - LICHT Design Management, DE 1 - L-Lab, DE 3 - Magistrat der Stadt Wien, MA 39, AT 1 - OMS Ltd., Slovakia 1 - OSRAM GmbH, Herbrechtingen, DE 2 - OSRAM GmbH, Munic, DE 2 - Philips Technologie GmbH, DE 2 - Regent Beleuchtungskörper AG, Switzerland 1 - Riegens A/S, Denmark 1 - RZB Leuchten, DE 1 - SGS Fimko Ltd, Finland 1 - SITECO, DE 1 - Sony Corporation, Tokyo 3 - Spittler Lichttechnik GmbH, DE 1 - Technische Universität Berlin, DE 3 - Technische Universität Ilmenau, DE 1 2 - TRILUX GmbH & Co. KG, DE 1 - TULUX AG, Switzerland 1 - University of Tehran 1 - VNISI, Russian Lighting Research Institute, Moscow 1 - Zumtobel STAFF GmbH & Co. KG, DE 10 1 RiGO801 Luminaire 2 RiGO801 Lamps 3 RiGO801 LED 4 Special Page 17