STATIC UNDER-OVER VOLTAGE RELAY VD SERIES

Similar documents
DIGITAL UNDER-OVER VOLTAGE RELAY DMPVR SERIES

STATIC PHASE FAILURE RELAY

DIGITAL EARTH FAULT RELAY

DIGITAL UNDER-OVER VOLTAGE RELAY DMPVR SERIES

MOTOR PROTECTION RELAY

STATIC EARTH FAULT RELAY

RESTRICTED EARTH FAULT RELAY

Voltage Relays. Ensuring Reliable Protection for Electrical Systems against Voltage Faults. ISO 9001:2008 Certified.

Technical Datasheet. True RMS Digital Protection Relay. Line Monitoring Relay

Relay. Technical Datasheet. True RMS Digital Protection Relay. Line Monitoring Relay

Technical Datasheet. True RMS Digital Protection Relay. Voltage Protection Relay

DIGITAL EARTH FAULT RELAY

Earth Fault Relay EFSPL-1A/5A

1 INTRODUCTION ORDER CODE / INFORMATION

AU INSTALLATION INSTRUCTIONS. Revision B1 Rapid City, SD, USA, 02/2010 II_201A-AU_B1

WD series DIN Rail or Screw Mounted Protective Relays

Multimeter 560CVD11 Data sheet

XP2-R Power and reverse power relay. (January 2006) Manual XP2-R (Revision New)

Multimeter 500CVD21 RTU500 series

XUA1 AC Voltage and phase balance relay. (August 1996) Manual XUA1 (Revision New)

Stabilized Differential Relay SPAD 346. Product Guide

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

XP2-R Power and Reverse Power Relay

Fault indicator. Application. SPEF 3A2 C 1MRS MBG Issued: April 1999 Status: Updated Version: B/ Data subject to change without notice

Technical Data Sheet. x1000. kwh R Y B

Motor Protective Relay

Connection Impact Assessment Application

XR1 Rotor Earth Fault Relay. Manual XR1 (Revision C)

02/11/2015

Guidelines to Using a Three Phase Voltage Monitor

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

SPAE 010, 011 High Impedance Protection Relay

Thermistor motor protection relays

GS1 Parameter Summary Detailed Parameter Listings...4 9

XUA1 - AC Voltage and phase balance relay

www. ElectricalPartManuals. com Basler Electric P. 0. BOX 269 HIGHLAND, ILLINOIS 62249, U.S.A. PHONE FAX

02/11/2015

Numbering System for Protective Devices, Control and Indication Devices for Power Systems

Impact Assessment Generator Form

ELECTRICIAN S THEORY EXAMINATION 15 November 2014 QUESTION AND ANSWER BOOKLET

DETUNED INDUCTORS FOR PF IMPROVEMENT CAPACITORS

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

ECM3 EARTH CONTINUITY RELAY

Electronic Circuit Breaker ESS20-0..

COOPERATIVE PATENT CLASSIFICATION

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300

FG2 TWO-CHANNEL DETECTOR

Power factor correction and harmonic filtering. Automatic power factor regulators

02/11/2015

200ADM-P. Current Injection System with Phase Shift A 3.000s 2.000A 50.00Hz 0.0. Features

Current monitor Type C 551

E-STOP relays, safety gate monitors

Insulation coordination (EN ) Standards EN Note 24 V DC / 24 V DC 0,1 A. 230 V AC ±10% Power rating 24 V DC ±20 % 140 mw

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

INSTRUCTIONS MANUAL DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS HRI-R40W

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks

Thermistor motor protection relays

Three-phase monitoring relays CM-PFE and CM-PFE.2

02/11/2015

Energy Management Energy Meter GM3D

Weekly Timer. ON/OFF and cycle operations up to one week Two SPST-NO time limit contacts with manual override switches

A New Fault Detection Tool for Single Phasing of a Three Phase Induction Motor. S.H.Haggag, Ali M. El-Rifaie,and Hala M.

OPERATING MANUAL OF µ-mpd-dxc ( 40 TO 500A)

Installation and start up instructions. Detection of vector shift. Detection of over- and underfrequency. Generator disconnection on mains failure

Three-phase monitoring relay

Functional Range. IWE - Earth Fault Relay. C&S Protection & Control Ltd.

HI-Physix Laboratory, L-83, Sector-1, DSIDC Industrial Area, Bawana, Delhi. Discipline Electronics Testing Issue Date

Intermittent transient earth fault protection

SELCO T-Line Generator Control, Protection and Monitoring

Up to 15 kw Power in Charge, 14.4 kva in Standalone and 13.2 kva in Utility Mode. 90 % Typical Efficiency. Charge Mode Output VDC

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

Transformer Winding Machine Controller (CNC-07SG)

GESS Industrial UPS System. Overview

Monitoring voltages of 3-phase 4 wires with a single unit

Monicon International Co., Ltd ATS 100 ATS 100 Controller User Manual

3. Be aware of the ambient temperature. Use the unit within the specified ambient temperature only.

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Marine Type Protective Relays VOLTAGE AND FREQUENCY RELAY 3PHASE PHASE FAIL RELAY 3PHASE PHASE SEQUENCE INDICATOR RELAY SINGLE SYNCHROSCOPE

Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS

XU2-AC AC voltage relay. (Februar 1997) Manual XU2-AC (Revision New)

THE ELECTROM itig II MOTOR TESTER AND WINDING ANALYZER

FEATURES OPTIONAL FEATURES

Zelio Control Measurement Relays

Positive-guided relay outputs: 8 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

SLU SERIES Universal Phase Monitor/Relay SLU-100-ASA and SLU-100-ASD

Electronic circuit breaker ESS30-Sxxx-DC24V

Distance Protection for Distribution Feeders. Presented By: Yordan Kyosev, P.Eng. & Curtis Ruff, P.Eng.

Content. Monitoring relay pluggable. 1-phase current monitoring relay phase direct-current voltage monitoring relay... 5.

Earth fault protection for isolated neutral systems with frequency converters

38 Series - Relay interface modules A

Operating Instructions

38 Series - Relay interface modules A

sw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

Embedded Generation Connection Application Form

Excitation Systems THYRIPART. Compound-Excitation System for Synchronous Generators. Power Generation

Transcription:

STATIC UNDER-OVER VOLTAGE RELAY

Features Solid state circuitry Negative Phase sequence voltage detection Definite fixed or variable time delay Low power consumption. reset Fail safe system LED indication for healthy and fault indication DIN rail mounting Applications Protection of synchronous and induction motors of any HP rating Protection of generators, AMF switch Boards Transformer feeder panel Distribution boards Voltage regulators Protection f or UPS and single phase applications Introduction Prok Dvs make RELAY WITH PHASE FAILURE (SINGLE PHASING) AND PHASE REVERSAL RELAY for protection against under voltages, over voltages, phase failure, phase reversal and unbalance voltages caused due to transients such as inductive load switching and commutation voltage spikes etc. Prok Dvs Make RELAY WITH PHASE FAILURE (SINGLE PHASING) AND PHASE REVERSAL RELAY available in five models i.e. VD-02, VD-03, VD-04, VD-05 and VD-06 for various applications. They are provided with fixed or variable voltage settings, auto reset, definite time delay fixed or variable settings. Description In motors operating at low loads, failure of any one phase causes over voltages, which may cause rupture of insulation leading to motor burn out. Low voltage will cause synchronous motors to come out of synchronism at 75% of rated voltage. Induction motors may stop when voltage falls below 70%. Over voltages may occur due to defective voltage regulator, over speeding, caused by sudden drop in load on account of this di-electric property deteriorates. In single phase supply low voltage may cause over load on supply cable and thermal damage to insulation of windings.

Specifications PARAMETERS VD 02 VD 03 System voltage Sensing Aux. Voltage(Un): Contacts & ra ng: Trip Voltage se ngs: a) Under voltage: b) Over voltage: c) Phase to phase unbalance Reset gap (Max): a) under /over voltage b) unbalance voltage Trip me delay: a) phase fail b) under /over voltage Rese ng mode: Indica on: a) Green LED b) Red LED Moun ng: Power consump on: Insula on: 415VAC + 20%, 50Hz. 110V/230V/415VAC + 20%,50Hz 80% 95% of Un, in steps of 3% 105% 120% of Un, in steps of 3% 50V fixed. 15V + 5V 5 10V 2 4Sec fixed. 100msec fixed. 1). Phase fail/phase reversal/ Phase unbalance 2). Under voltage trip indica on 3). Over voltage trip indica on 2KV, 50Hz f or 1min 415VAC + 20%,50Hz. 110V/230V/415VAC +20%,50Hz 80% 95% of Un, in steps of 3% 105% 120% of Un, in steps of 3% 50V fixed. 15V + 5V 5 10V 2 4Sec fixed. 0 15 sec variable in steps o f 3sec. 1). Phase fail/phase reversal/ Phase unbalance 2). Under voltage trip indica on 3). Over voltage trip indica on 2KV, 50Hz f or 1min

Specifications PARAMETERS VD 04 VD 05 System vo ltage Sensing Aux. Voltage(Un): Contacts & ra ng: Trip Voltage se ngs: Under Voltage: Over Voltage: Phase to phase unbalance Reset gap (Max): Under /Over voltage Unbalance voltage Trip me delay: a) phase fail b) Under /Over Voltage 230VAC+ 20%,50Hz 160V 210V, variable in steps of 10V 240V 290V, variable in steps of 10V 07V+3V 100msec fixed. 415VAC + 20%,50Hz. 110V/230V/415VAC +20%,50Hz 80% 95% of Un, in s teps of 3% 50V fixed. 15V + 5V 5 10V 2 4Sec fixed. 0 15 sec variable in steps o f 3sec. Rese ng mode: Indica on: a) Green LED b) Red LED Moun ng: Power consump on: Insula on: 1). Under Voltage trip indica on 2). Over Voltage trip indica on 2KV, 50Hz for 1min 1). Phase fail/phase reversal/ Phase unbalance 2). Under voltage trip indica on 2KV, 50Hz for 1min

Specifications PARAMETERS System voltage Sensing Aux. Voltage(Un): Contacts & ra ng: Trip Voltage se ngs: a) Under voltage: b) Over voltage: c) Phase to phase unbalance Reset gap (Max): a) under /over voltage b) unbalance voltage Trip me delay: a) phase fail b) under /over voltage Rese ng mode: Indica on: a) Green LED b) Red LED Moun ng: Power consump on: Insula on: VD 06 415VAC + 20%, 50Hz. 110V/230V/415VAC + 20%,50Hz 105% 120% of Un, in steps of 3% 50V fixed 50V Fixed 15V + 5V 5 10V 2 4Sec fixed. 0 15 sec variable in steps o f 3sec. 1) Phase fail/phase reversal/ Phase unbalance 2) Over Voltage trip indica on 2KV, 50Hz for 1min

Wiring Diagram STATIC OVER VOLTAGE (OV) AND UNDER VOLTAGE (UV) RELAY WITH PHASE FAILURE (SINGLE PHASING) AND PHASE REVERSAL RELAY- VD-04 Wiring Diagram STATIC OVER VOLTAGE (OV) AND UNDER VOLTAGE (UV) RELAY WITH PHASE FAILURE (SINGLE PHASING) AND PHASE REVERSAL RELAY- VD-02/VD-03/VD- 05/VD-06

Mechanical Dimensions STATIC OVER VOLTAGE (OV) AND UNDER VOLTAGE (UV) RELAY WITH PHASE FAILURE (SINGLE PHASING) AND PHASE REVERSAL RELAY - DIN MOUNTING

ISO 9001-2015 PROK DEVICES PRIVATE LIMITED nd rd B-80, 2 & 3 Floor, KSSIDC Industrial Estate th th 4 Main Road, 6 Block, Rajajinagar Bengaluru-560010 Karnataka,India Ph. No: 080-4148 0777 080-4115 7700 Fax:+91 80 26761720 For Marketing Information & Assistance enquiry@prokdvs.com marketing@prokdvs.com For Product Information & Technical Details info@prokdvs.com For Service Information service@prokdvs.com