Electromagnetic compatibility - sensibility of implantable

Similar documents
Potential Risks of MRI in Device Patients

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University

Biological Safety. Electromagnetic Compatibility (EMC) Observe the following precautions related to biological safety.

IEEE Electromagnetic Compatibility Standards (Active & Archive) Collection: VuSpec

SJM MRI Activator. Handheld Device. User's Manual. Model EX4000

One-day Conference 18 March Power Supply, EMC and Signalling, in Railway Systems

National Voluntary Laboratory Accreditation Program

AP7301 ELECTROMAGNETIC INTERFERENCE AND COMPATIBILITY L T P C COURSE OBJECTIVES:

EMC in the railway environment Hans Bängtsson

Electromagnetic and Radio Frequency Interference (EMI/RFI) Considerations For Nuclear Power Plant Upgrades

Prof. Steven S. Saliterman. Department of Biomedical Engineering, University of Minnesota

Test and Measurement for EMC

Electromagnetic Compatibility

BIODEX MULTI- JOINT SYSTEM

An Introduction to EMC Testing (what can be done with scopes) Vincent Lascoste EMC Product Manager - RSF

Top Ten EMC Problems

by Jim Philips, P.E. Pass Interference Ensuring the Electromagnetic Compatibility of Variable Frequency Drives

Overview of the ATLAS Electromagnetic Compatibility Policy

National Voluntary Laboratory Accreditation Program

National Voluntary Laboratory Accreditation Program

OtoRead - Technical Specifications Page 0. Technical Specifications. OtoRead D A 2017/06

Azure XT SR MRI SureScan W1SR01

Technical Specifications Micromedical VisualEyes 505 by Interacoustics

EMC standards. Presented by: Karim Loukil & Kaïs Siala

EMC and Variable Speed Drives

EMC Test Report. Report Number: M030826

Electromagnetic compatibility Guidance and manufacturer s declaration DIN EN :2007 (IEC :2007)

Application Note # 5438

RADIOFREQUENCY INTERFERENCE WITH MEDICAL DEVICES

2620 Modular Measurement and Control System

Fundamentals of EMC Theory and Principles

Immunity Testing for the CE Mark

EMC Seminar Series All about EMC Testing and Measurement Seminar 1

AS/NZS CISPR 14.2:2015

Essentia Electromagnetic Monitor Model: EM2

Characterization of medical devices electromagnetic immunity to environmental RF fields.

Technical Data. Electrocardiograph ECG-1250K TD.ECG1250_L. This technical data may be revised or replaced by Nihon Kohden at any time without notice.

General Safety/EMC and Electrical Information for i-limb ultra and i-limb digits

PHYSIOFLOW Q-LINK TM

Scale Manufacturers Association (SMA) Recommendation on. Electrical Disturbance

R&TTE Testing For EU Market

Radiated radiofrequency immunity testing of automated external defibrillators - modifications of applicable standards are needed

EMC Overview. What is EMC? Why is it Important? Case Studies. Examples of calculations used in EMC. EMC Overview 1

Copenhagen, May 17 th Light Rail and EMC. Dr.-Ing. Lorenz Jung, Siemens AG, Mobility Division. Siemens AG 2016 All rights reserved.

520 IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, VOL. 52, NO. 3, MARCH 2005

EMI Installation Guidelines

D C 01/2019 3

Guidance and Declaration - Electromagnetic Compatibility (EMC) for the Delfi PTS ii Portable Tourniquet System

Earthing for EMC in Installations

Analysis and Minimizing Strategies for Conducted Emission from Power Supply Cable of GPS Based Vehicle Tracking System

Introduction to Medical EMC

Research on Electromagnetic Compatibility of New Energy Vehicles

Transmitter Model EX1100, EX1100W. User's Manual

EC6011-ELECTROMAGNETICINTERFERENCEANDCOMPATIBILITY

Wireless Interference in Healthcare Is Real, but Manageable

Introduction EMC. Filter parameters. Definition of EMC / EMI. X-Capacitor. Sources of EMI. Coupling mechanism. Y-Capacitor.

Certificate of Test AND KEEPS ALL REQUIREMENTS ACCORDING THE FOLLOWING REGULATIONS IEC :2001 IEC :2007

SERIES K: PROTECTION AGAINST INTERFERENCE

Transfer Functions in EMC Shielding Design

Si-Hall ICs. 1 Application Notes for Differential Hall IC s

This annex is valid from: to Replaces annex dated: Locations where activities are performed under accreditation

Understanding Noise Cut Transformers

Electromagnetic Sources in the Hospital Environment: Risks Analysis and Measures for Electro-Magnetic Compatibility (EMC)

American National Standard for Methods of Measurement. Frequency allocations and radio treaty matters; general rules and regulations

EMC & Wireless Device Requirements and Compliance Design Seminar

INTERNATIONAL TELECOMMUNICATION UNION SERIES K: PROTECTION AGAINST INTERFERENCE

CHAPTER ELECTROMAGNETIC COMPATIBILITY. Contents of this Chapter...

Powered Traction Unit OPERATION MANUAL

AUTOMOTIVE ELECTROMAGNETIC COMPATIBILITY (EMC)

Power Quality Issues from an EMC Point of View

Fundamentals of Pacing Therapy

PHY Layout APPLICATION REPORT: SLLA020. Ron Raybarman Burke S. Henehan 1394 Applications Group

Electromagnetic Compatibility ( EMC )

Verifying Simulation Results with Measurements. Scott Piper General Motors

Todd Hubing. Clemson University. Cabin Environment Communication System. Controls Airbag Entertainment Systems Deployment

Appendix A: Specifications

Holiday Detector mod. 284/35KV

Solution of EMI Problems from Operation of Variable-Frequency Drives

RF EMF Strength Meter

SERIES K: PROTECTION AGAINST INTERFERENCE

SAVI SCOUT Surgical Guidance System. Console Operation Manual

Technologies and threats for the IoT. November 24th 2015 Anders P. Mynster

Testing for EMC Compliance: Approaches and Techniques October 12, 2006

Definitions of Technical Terms

EMC aspects associated to 5G networks

Immunity of Electrical/Electronic Equipment Intended to Operate in the Canadian Radio Environment ( ,000 MHz)

Quotient Associates Ltd RA AY CR3 CONTENTS

Todd H. Hubing Michelin Professor of Vehicular Electronics Clemson University

Australian/New Zealand Standard

St. Jude Medical Patient Controller. For Spinal Cord Stimulation Systems Model User's Guide

Chapter 16 PCB Layout and Stackup

Use optocouplers for safe and reliable electrical systems

CHARACTERISATION OF IN -HOUSE EMC TESTING FACILITIES FOR PRODUCT DESIGNERS. Paul Kay* and Andrew Nafalski**

English

Product Safety and RF Energy Exposure Booklet for Portable Two-Way Radios

ELEC 0017: ELECTROMAGNETIC COMPATIBILITY LABORATORY SESSIONS

AS/NZS CISPR 14.1:2013

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

EMC and New Technologies in Automotive Systems

EMC Introduction. What is EMC. EMS (Susceptibility) Electro-Magnetic Compatibility EMC. Conducted Emission EMI. Conducted Susceptibility

Transcription:

Sveučilište u Zagrebu Fakultet elektrotehnike i računarstva Biomedicinska instrumentacija Electromagnetic compatibility - sensibility of implantable electronic devices to different kinds of electroterapy Ratko Magjarević University of Zagreb Faculty of Electrical Engineering and Computing Croatia ratko.magjarevic@fer.hr

Electromagnetic compatibility (EMC) the degree to which an electronic system is able to function compatibly with other electronic systems not susceptible to interference not produce interference Opposite: Electromagnetic interference (EMI) EMC - Implantable Devices 2

Electromagnetic interference (EMI) disturbance that t affects an electrical l circuit it due to electromagnetic ti radiation electromagnetic conduction (bellow ~50 MHz) electrostatic discharge emitted from a source external internal may interrupt, degrade or obstruct the performance of an electronic circuit EMC - Implantable Devices 3

Electromagnetic interference (EMI) Inductive coupling Inductive coupling occurs where the source and receiver are separated by a short distance (typically less than a wavelength). Strictly, "Inductive coupling" can be of two kinds, electrical induction and magnetic induction. It is common to refer to electrical induction as capacitive coupling, and to magnetic induction as inductive coupling. Capacitive coupling Capacitive coupling occurs when a varying electrical field exists between two adjacent conductors typically y less than a wavelength apart, inducing a change in voltage across the gap. EMC - Implantable Devices 4

Electromagnetic interference (EMI) Conductive coupling Conductive coupling occurs when the coupling path between the source and the receptor is formed by direct contact with a conducting body, for example a transmission line, wire, cable, PCB trace or metal enclosure. Conduction modes Conducted noise is also characterised by the way it appears on different conductors: Common-mode or common-impedance[1]) coupling: noise appears in phase (in the same direction) on two conductors. Differential-mode coupling: noise appears out of phase (in opposite directions) on two conductors. EMC - Implantable Devices 5

Electromagnetic interference (EMI) Magnetic coupling Inductive coupling or magnetic coupling (MC) occurs when a varying magnetic field exists between two parallel conductors typically less than a wavelength apart, inducing a change in voltage along the receiving conductor. Radiative coupling Radiative coupling or electromagnetic coupling occurs when source and victim are separated by a large distance, typically more than a wavelength. Source and victim act as radio antennas: the source emits or radiates an electromagnetic wave which propagates across the open space in between and is picked up or received by the victim. EMC - Implantable Devices 6

EMI Growth The power density of EMI in an average urban environment since Light pollution is 1 to 1 correlated with 1945. electromagnetic energy leaking into the environment. Where there is artificial light there is electromagnetic interferences. from: www.biotele.com/emi.htm EMC - Implantable Devices 7

Pacemakers and EMI pacemaker life saving device + EMI - may interrupt, degrade or obstruct the performance of an electronic circuit it = EMI may be life-threatening for patients with pacemakers Ruggera P.S. and R. Elder, Electromagnetic Radiation Interference with Cardiac Pacemakers, DHEW publication BRH DEP 71-5, 1971 EMC - Implantable Devices 8

EMI to (other) Medical Devices Documented cases: a ventilator suddenly changes its breath rate an electric powered wheelchair suddenly veers off course an apnea monitor fails to alarm... Casamento JP, Ruggera PS.Applying standardized electromagnetic compatibility testing methods for evaluating radiofrequency interference with ventilators, Biomed Instrum Technol. Witters D.M. and P. S. Ruggera, EMC of Powered Wheelchairs and Scooters, Proc. RESNA '94 EMC - Implantable Devices 9

Solving EMI at System Level EMI involves: the device itself the environment in which it is used anything that may come into that environment EMI - a systems problem requiring a systems approach EMI solution requires involvement of the (medical) device industry, the EM source industry (power industry, telecommunications industry...), the clinical user and patient EMC - Implantable Devices 10

IEC Classification International ti Electrotechnical Commission (IEC) classification of EM environment Conditions for the location and power of local l EM energy sources (e.g., transmitters) Table 1 indicates the general classifications and the upper range of radiated EM field strength specified for each environment. EMC - Implantable Devices 11

Sources of EMI Radio broadcasting Television Public safety (police, fire, highway, forestry, and emergency services) Land transportation (taxis, trucks, buses, railroads) Amateur radio Cellular phones and paging systems Industrial, scientific, and medical Citizens' band (CB) radio Radar... EMC - Implantable Devices 12

Factors affecting EMC Frequency, Wavelength, and Antenna Effect Depth of Implantation Modulation Examples of Recorded d Device Malfunction Due to EMI Electroencephalographic cep og ap c interference e e Impedance-based apnea monitor mishaps Monitor alarms Mechanism of death due to apnea Susceptibility to EMI Drug-infusion pump mishaps Ventilator mishaps Powered-vehicle mishaps EMC - Implantable Devices 13

Examples of Recorded Device Malfunction Due to EMI Cellular and Mobile Telephone-Generated EMI Infant radiant warmer mishaps Miscellaneous medical device mishaps Health effects Blood pressure monitor EMC - Implantable Devices 14

Cardiac Pacemakers and EMI Implanted pacemakers Pacemaker malfunction due to cellular Communication with an implanted phones pacemaker Pacemaker malfunction due to magnetic Failure modes resonance imagers Effect of EMI on pacemaker function Pacemaker malfunction due to Pacemaker malfunction due to microwave-oven EMI electrosurgery Pacemaker malfunction due to low- Abandoned pacemaker lead frequency EMI accident Electronic surveillance systems Pacemaker malfunction due to paging system EMC - Implantable Devices 15

Implanted cardioverter defibrillator (ICD) Effect of EMI on ICDs ICD malfunction due to arc welders Cell-phone EMI Slot machine EMI Pacemaker and ICD interaction Improper electrode placement Powerline ICD accident EMC - Implantable Devices 16

Electrostatic Discharge Introduction ESD testing Mechanism of action of ESD ESD incidents Effect of ESD on human subjects EMC - Implantable Devices 17

Model of Interference EMC - Implantable Devices 18 from: S. Hrabar, Analysis of EMI between mobile telephone and impllanted medical device, Ph.D. thesis, 1999

Definitions to EMC problems Imunity to disturbance ability of a device to perform without degradation in presence of EMI Compatibility level l specified EM disturbance level expected to be impressed to a device Imunity level l max level l of given EM disturbance incident on a particular device Imunity margin difference between the imunity it level and EM compatibility level from IEEE standards EMC - Implantable Devices 19

Immunity Limit EMC - Implantable Devices 20 from: S. Hrabar, Analysis of EMI between mobile telephone and impllanted medical device, Ph.D. thesis, 1999

Block diagram of an unipolar pacemaker EMC - Implantable Devices 21

Unipolar Sensing Produces a large potential difference due to: A cathode and anode that are farther apart than in a bipolar system What about EMI? _ EMC - Implantable Devices 22

Block diagram of a bipolar pacemaker EMC - Implantable Devices 23

Bipolar Sensing Produces a smaller potential difference due to the short interelectrode distance: Electrical signals from outside the heart such as myopotentials are less likely to be sensed EMC - Implantable Devices 24

Amplifier Circuits - DC coupled EMC - Implantable Devices 25

Amplifier Circuits - AC coupled EMC - Implantable Devices 26

Biopotential Isolation Amplifier EMC - Implantable Devices 27

EMC - Implantable Devices 28

EMC - Implantable Devices 29

EMC - Implantable Devices 30

EMC - Implantable Devices 31

Electromagnetic Interference EMC - Implantable Devices 32

Electromagnetic Interference (EMI) Interference is caused by electromagnetic energy with a source that is outside the body Electromagnetic fields that may affect pacemakers are radio-frequency waves 50-60 Hz are most frequently associated with pacemaker interference Few sources of EMI are found in the home or office but several exist in hospitals EMC - Implantable Devices 33

EMC - Implantable Devices 34

EMC - Implantable Devices 35

EMI May Result in the Following Problems: Oversensing Transient mode change (noise reversion) Reprogramming (Power on Reset or POR ) EMC - Implantable Devices 36

Oversensing May Occur When EMI Signals Are Incorrectly Interpreted as P Waves or R Waves Pacing rates will vary as a result of EMI: Rates will accelerate if sensed as P waves in dual-chamber systems (P waves are tracked ) Rates will be low or inhibited if sensed in single-chamber systems, or on ventricular lead in dual-chamber systems EMC - Implantable Devices 37

EMI Noise sensed by the pacemaker Should have paced EMC - Implantable Devices 38

Noise Reversion Continuous refractory sensing will cause pacing at the lower or sensor driven rate Lower Rate Interval Noise Sensed VP SR SR SR SR VP EMC - Implantable Devices 39

EMI May Lead to Inadvertent Reprogramming of the Pacing Parameters Device will revert to Power on Reset (POR or backup mode) Power on Reset may exhibit a mode and rate change which are often the same as ERI In some cases, reprogrammed parameters may be permanent EMC - Implantable Devices 40

New technologies will continue to create new, unanticipated sources of EMI: Cellular phones (digital) EMC - Implantable Devices 41

Sources of EMI Are Found Most Commonly in Hospital Environments Sources of EMI that interfere with pacemaker operation include surgical/therapeutic equipment such as: Electrocautery Transthoracic defibrillation Extracorporeal shock-wave lithotripsy Therapeutic radiation RF ablation TENS units MRI EMC - Implantable Devices 42

Sources of EMI Are Found More Rarely in: Home, office, and shopping environments Industrial environments with very high electrical outputs Transportation T t ti systems with high h electrical l energy exposure or with high-powered radar and radio transmission Engines or subway braking systems Airport radar Airplane engines TV and radio transmission sites EMC - Implantable Devices 43

Electrocautery is the Most Common Hospital Source of Pacemaker EMI Outcomes Precautions Oversensing inhibition Reprogram mode to Undersensing g( (noise VOO/DOO, reversion) or place a magnet over Power on Reset device Permanent loss of Strategically place the pacemaker grounding plate output (if battery voltage is Limit electrocautery bursts low) to 1-second burst every 10 seconds Use bipolar electrocautery forceps EMC - Implantable Devices 44

Transthoracic Defibrillation Outcome Inappropriate reprogramming of the pulse generator (POR) Damage to pacemaker circuitry Precautions Position defibrillation paddles apex-posterior (AP) and as far from the pacemaker and leads as possible EMC - Implantable Devices 45

Magnetic Resonance Imaging (MRI) is Generally Contraindicated in Patients with Pacemakers Outcomes Precautions Extremely high pacing rate Reversion to asynchronous pacing Program pacemaker output low enough to create persistent non-capture, ODO or OVO mode EMC - Implantable Devices 46

Lithotripsy Shock Waves May Have an Effect on Pacemaker Systems Outcomes in Precautions: dual-chamber modes: Program pacemaker to VVI Inhibition of ventricular or VOO mode pacing Lithotriptor focal point should be greater than 6 inches from the pacemaker Outcomes in rate adaptive pacemakers High pacing rates Piezoelectric crystal damage Carefully monitor heart function throughout procedure EMC - Implantable Devices 47

Radiation Energy May Cause Permanent Damage Certain kinds of radiation energy may cause damage to the semiconductor circuitry Ionizing radiation used for breast or lung cancer therapy Damage can be permanent and requires replacement of the pacemaker EMC - Implantable Devices 48

Therapeutic Radiation May Cause Severe Damage Outcomes: Pacemaker circuit damage Loss of output Runaway Precautions: Keep cumulative radiation absorbed by the pacemaker to less than 500 rads; shielding may be required Check pacemaker after radiation sessions for changes in pacemaker function (can be done transtelephonically) EMC - Implantable Devices 49

Pacemaker Features That Address Interference Pacemaker sensing circuits amplify, filter and either process or reject incoming signals Input Bandpass filter Absolute value Reversion circuit Level detector Pacemaker logic Sensitivity adjustment EMC - Implantable Devices 50

Equipment interference with pacemakers At home Household devices: shavers, hairdryers and microwave ovens, household tools such as drills,mowers and electric screwdrivers - not be a problem, as long as they are well maintained. Phones Useing a mobile phone or a cordless phone is safe, but it is best to keep the phone more than 15 centimetres (6 inches) from your pacemaker. Always use the ear on the opposite side to your pacemaker, and do not put the phone in a pocket over your pacemaker. Travelling and security systems Airport screening systems and anti-theft systems in shops and libraries may, very rarely, cause problems with pacemakers. There is also a small chance that you may trigger the alarms. Always carry your pacemaker registration card with you. In some countries you may be asked to go through the security system. Move quickly through the gateway. EMC - Implantable Devices 51

Equipment interference with pacemakers At work Some workplaces have strong electromagnetic fields which can interfere with your pacemaker. Arc-welding is an example. In hospitals Some hospital equipment may interfere with pacemakers. Some types of equipment used in surgery can also cause problems. Magnetic resonance imaging i (MRI) scans can be dangerous for pacemaker patients.. EMC - Implantable Devices 52

The SureScan Pacing System The first pacing systems designed, tested and approved for MRI EMC - Implantable Devices 53

The SureScan Pacing System Patients and physicians need a device specifically designed to address the unique hazards of magnetic resonance imaging. Professor Richard Sutton St. Mary s Hospital, London EMC - Implantable Devices 54

Pacing Systems need to be MRI-safe by Design not Chance Control about Reed switch behavior Better protection against electromagnetic interference leading to electrical reset Programmable MRI modes for different pts. populations Leads with less RF-induction and less temperature increase EMC - Implantable Devices 55

SureScan Innovations Change: Lead input filtering capacitance Benefit: Minimize the energy induced on leads/discharged at tip Change: Reed switch replaced by Hall sensor Benefit: Control switch behavior Change: Internal power supply circuit protection Benefit: Prevents the energy induced on the telemetry antenna from disrupting the internal power supplies Change: Significantly reduced ferromagnetic components Benefit: Decrease susceptibility to magnetic attraction Reed Switch Hall sensor EMC - Implantable Devices 56

SureScan Innovations Change: Dedicated SureScan modes: asynchronous pacing or non pacing mode (Programmer+ Device Software/Firmware) Benefit: Ease of patient management Suspension of diagnostic data collection and atrial arrhythmia therapy EMC - Implantable Devices 57

SureScan Innovations Change: 5086 lead geometry and internal make up (filar #, pitch, size, Impedance, ) changed to prevent interactions with gradient field and produce low RF conduction characteristics Benefit: Reduces lead heating Standard MRI Pitch EMC - Implantable Devices 58

SureScan Innovations Change: Radiographic markers Benefit: Ease of device identification EMC - Implantable Devices 59

The SureScan Pacing System MRI-safe by Design not tchance 1997 Initiate Research 2001 Begin technology work with international eperts experts 2004 Commence formal discussions with regulatory bodies (TUV, FDA, ) 2005 Complete first system modifications: start extensive test program 2006 Finalize device modifications; define human clinical trial 2007 Commence worldwide EnRhythm MRI Pacing System clinical trial 2008 Clinical trial completed; CE mark received; EnRhythm MRI market release 2010 2 nd generation SureScan Pacing Systems market release MRI Unsafe MRI Conditional: Safe for use in MRI under certain conditions EMC - Implantable Devices 60

Approval by the authorities t SureScan was rigorously tested, clinically studied, and CE-mark approved The CE marking (also known as CE mark) is a mandatory conformance mark on many products placed on the single market in the European Economic Area (EEA). The CE marking certifies that a product has met EU consumer safety, health or environmental requirements. EMC - Implantable Devices 61

Literature Yadin, D et al, eds. Clinical Engineering CRC Press, 2003 Kimmel D.D., D.D. Gerke, Protecting Medical Devices From Electromagnetic Interference, Designer's Handbook: Medical Electronics, Brown,B.H. et alt., Medical Physics and Biomedical Engineering., g IoP Publishing, London, reprinted 2001. Webster,J.G. (Ed.), Medical Instrumentation, Application and Design. 2nd ed., J. Wiley & Sons, Inc., New York, 1995. Webster,J.G. (Ed.), Bioinstrumentation. John Wiley & Sons, Inc., New York, 2003 In Croatian: Šantić, A., Biomedicinska elektronika, Školska knjiga, Zagreb, 1995 EMC - Implantable Devices 62

Standards, Regulations... EU directive 2004/108/CE (previously 89/336/EEC) on EMC CISPR 11 - Industrial, scientific and medical (ISM) radio-frequency equipment - Electromagnetic disturbance characteristics - Limits and methods of measurement ANSI/AAMI PC69:2000, Active implantable medical devices- Electromagnetic compatibility- EMC test protocols for implantable cardiac pacemakers and implantable cardioverter defibrillators, American National Standards Institute, 2000. Medical Electrical Equipment, Part 1: General Requirements for Safety, Collateral Standard: Electromagnetic Compatibility, International Electrotechnical t l Commission i IEC 60601-1-2 1 IEC 1000-4-3 Electromagnetic Compatibility (EMC)- Part 4; Testing and measurement techniques- Section 3: Radiated, Radio frequency, electromagnetic field immunity test The Safe Medical Devices Act (SMDA) of 1990, Public Law 91-4243. International Electrotechnical Committee IEC/TC or SC: TC77, Electromagnetic Compatibility Between Electrical Equipment Including Networks, Classification of Electromagnetic Environments... EMC - Implantable Devices 63