Basic Resolution Testing using Test Charts

Similar documents
SINEPATTERNS LLC THE SINE PATTERNS CATALOG

USAF Bar Resolving Power Test Chart

Parameters of Image Quality

Evaluating Commercial Scanners for Astronomical Images. The underlying technology of the scanners: Pixel sizes:

DECODING SCANNING TECHNOLOGIES

TECHNICAL SUPPLEMENT. PlateScope. Measurement Method, Process and Integrity

A Handheld Image Analysis System for Portable and Objective Print Quality Analysis

Optoliner NV. Calibration Standard for Sighting & Imaging Devices West San Bernardino Road West Covina, California 91790

Century focus and test chart instructions

WHITE PAPER. How to Include Detector Resolution in MTF Calculations. Zemax A Radiant Zemax Company

KODAK VISION Expression 500T Color Negative Film / 5284, 7284

EASTMAN EXR 200T Film / 5293, 7293

QUANTITATIVE IMAGE TREATMENT FOR PDI-TYPE QUALIFICATION OF VT INSPECTIONS

Migration from Contrast Transfer Function to ISO Spatial Frequency Response

Criteria for Optical Systems: Optical Path Difference How do we determine the quality of a lens system? Several criteria used in optical design

Determining MTF with a Slant Edge Target ABSTRACT AND INTRODUCTION

MTF Analysis and its Measurements for Digital Still Camera

IMAGE SENSOR SOLUTIONS. KAC-96-1/5" Lens Kit. KODAK KAC-96-1/5" Lens Kit. for use with the KODAK CMOS Image Sensors. November 2004 Revision 2

ISO INTERNATIONAL STANDARD. Photography Electronic scanners for photographic images Dynamic range measurements

ISO INTERNATIONAL STANDARD. Photography Electronic scanners for photographic images Dynamic range measurements

Commercial Scanners and Science

Complete the diagram to show what happens to the rays. ... (1) What word can be used to describe this type of lens? ... (1)

Edge-Raggedness Evaluation Using Slanted-Edge Analysis

EASTMAN EXR 200T Film 5287, 7287

Lecture 9. Lecture 9. t (min)

Bar code Verifier Conformance Specifications. Using the INTEGRA-9000

Resolution test with line patterns

Seiki Miyashita, Miyuki Shibata, Akio Minoura, Yutaka Kataoka Otani University, Kyoto, Japan

COURSE NAME: PHOTOGRAPHY AND AUDIO VISUAL PRODUCTION (VOCATIONAL) FOR UNDER GRADUATE (FIRST YEAR)

EASTMAN PLUS-X Reversal Film / 7276

Refraction, Lenses, and Prisms

KODAK PRIMETIME 640T Teleproduction Film / 5620,7620

Practical Scanner Tests Based on OECF and SFR Measurements

Understanding Infrared Camera Thermal Image Quality

This Color Quality guide helps users understand how operations available on the printer can be used to adjust and customize color output.

ST-53-X-ISO Dynamic Range Film Target Product Specifications

9/19/16. A Closer Look. Danae Wolfe. What We ll Cover. Basics of photography & your camera. Technical. Macro & close-up techniques.

Slide Scanning Converting Your Film Photographs to Digital. Presentation to UCHUG - 8/06/08 G. Skalka

ISO INTERNATIONAL STANDARD. Photography Electronic scanners for photographic images Dynamic range measurements

How to Optimize the Sharpness of Your Photographic Prints: Part I - Your Eye and its Ability to Resolve Fine Detail

An Evaluation of MTF Determination Methods for 35mm Film Scanners

: Dual Mode DHA 24.0 ENHANCED SUNLIGHT READABLE DISPLAY WITH NIGHT VISION CAPABILITY

: Dual Mode DHA 10.4 ENHANCED SUNLIGHT READABLE DISPLAY WITH NIGHT VISION CAPABILITY

EASTMAN EXR 500T Film 5298

: Dual Mode DHA 6.4 ENHANCED SUNLIGHT READABLE DISPLAY WITH NIGHT VISION CAPABILITY

EASTMAN TRI-X Reversal Film 7278

Quantitative Analysis of ICC Profile Quality for Scanners

LEICA Summarit-S 70 mm ASPH. f/2.5 / CS

UK ARCHIVING. preserving our heritage. 4 Bankhead Medway, Edinburgh, EH11 4BY. Microfilm Quality Control Inspection

Review of graininess measurements

ISO INTERNATIONAL STANDARD. Photography Electronic scanners for photographic images Dynamic range measurements

How to Choose a Machine Vision Camera for Your Application.

GlassSpection User Guide

Lens Types. Single Vision. Lined Bi-Focal. Lined tri-focals

LEICA VARIO-ELMARIT-R mm f/2,8-4,5 ASPH. 1

MILITARY SPECIFICATION LIGHTING, INSTRUMENT, INTEGRAL, WHITE GENERAL SPECIFICATION FOR

TIPA Camera Test. How we test a camera for TIPA

Chapters 1-3. Chapter 1: Introduction and applications of photogrammetry Chapter 2: Electro-magnetic radiation. Chapter 3: Basic optics

SHOOTING FOR HIGH DYNAMIC RANGE IMAGES DAVID STUMP ASC

What is a "Good Image"?

EE-527: MicroFabrication

: Dual Mode 15.6" DHA ENHANCED SUNLIGHT READABLE DISPLAY WITH NIGHT VISION CAPABILITY

What is? What is process?

: Dual Mode DHA 10.4 ENHANCED SUNLIGHT READABLE DISPLAY WITH NIGHT VISION CAPABILITY

Zone. ystem. Handbook. Part 2 The Zone System in Practice. by Jeff Curto

Fast MTF measurement of CMOS imagers using ISO slantededge methodology

LENSES. A lens is any glass, plastic or transparent refractive medium with two opposite faces, and at least one of the faces must be curved.

The digital microfiche/microfilm scanner allows to view, print and digitally convert library materials in these formats.

Tech Paper. Anti-Sparkle Film Distinctness of Image Characterization

Press Release. New packaging design for B+W filters. BAD KREUZNACH, 20 September Stylish appearance and clear orientation for the customer

Image Quality Assessment of Digital Scanners and Electronic Still Cameras

ISO/IEC TS TECHNICAL SPECIFICATION. Information technology Office equipment Test charts and methods for measuring monochrome printer resolution

The Bellows Extension Exposure Factor: Including Useful Reference Charts for use in the Field

A panchromatic negative film for aerial photography.

Understanding Histograms

Diazo C Microfilm 1957, 2957, 3957 Diazo D Microfilm 1956, 2956, 3956

A panchromatic negative film for aerial photography.

COURSE NAME: PHOTOGRAPHY AND AUDIO VISUAL PRODUCTION (VOCATIONAL) FOR UNDER GRADUATE (FIRST YEAR) PAPER TITLE: BASIC PHOTOGRAPHIC

Optimizing throughput with Machine Vision Lighting. Whitepaper

Refined Slanted-Edge Measurement for Practical Camera and Scanner Testing

Mastery. Chapter Content. What is light? CHAPTER 11 LESSON 1 C A

ISO INTERNATIONAL STANDARD. Photography Electronic still-picture cameras Resolution measurements

IMAGELINK Diazo Duplicating Microfilms

Part 1 Investigating Snell s Law

AIAA/USU Small Satellite Conference 2007 Paper No. SSC07-VIII-2

Lesson Title: The Science of Light and Photography Subject Grade Level Timeline. Physical Science minutes. Objectives

Kodak Thermal Print Microfilms

Aperture: Circular hole in front of or within a lens that restricts the amount of light passing through the lens to the photographic material.

Notes from Lens Lecture with Graham Reed

Digital Detector Array Image Quality for Various GOS Scintillators

SFR 406 Spring 2015 Lecture 7 Notes Film Types and Filters

Measurement of Texture Loss for JPEG 2000 Compression Peter D. Burns and Don Williams* Burns Digital Imaging and *Image Science Associates

The Electronic Darkroom: Improving Artifact Presentation

Optical Design of Full View Lens based on Energy Luminance Analysis Chart of Stray Light

Thermography. White Paper: Understanding Infrared Camera Thermal Image Quality

FMI. Commercial and Industrial Hi-Reliability Crystals & Oscillators. FREQUENCY MANAGEMENT I n t e r n a t i o n a l.

FEATURES GENERAL DESCRIPTION. CCD Element Linear Image Sensor CCD Element Linear Image Sensor

panda family ultra compact scmos cameras

Measuring MTF with wedges: pitfalls and best practices

Color Management User Guide

Transcription:

Basic resolution Testing A resolution test chart is used to allow quick and easy testing of the ability of an optical system to produce images with fine detail. The patterns are in groups which progressively get smaller. The smallest group for which the correct number of bars and spaces can be counted (in both directions) is the system resolution. Resolution is most commonly measured in cycles per mm (cy/mm), where a bar and a space equal one cycle. For example, a test image that has 5 cy/mm bars and spaces will have a bar 0.1mm wide and a space 0.1mm wide. Bar type test charts are normally available on photo paper for reflection imaging with bars down to about 20 cy/mm, transparent flexible film to about 180 cy/mm, and chrome on glass or opal to 512 cy/mm. When evaluating a system used for visual analysis, you need only to place a test pattern of known size in the field of view, then view it (by eye, camera, etc) to see the smallest group that is output. One of the oldest, most common charts is the USAF-1951 test chart which has some design features specified in Mil-Std-150A. It is available from Applied Image as the T-20 pattern and looks like: Page 1 of 6 rev 1-00.doc

One rather large drawback of this pattern, is that the labels only indicate groups and elements, so a look up chart is needed to find out what the actual resolution is of an element. The Applied Image T-21 solves this problem and still maintains compliance with Mil-Std-150A because the standard only specifies the density, number of bars, and progression of elements (not the labeling of arrangement). The T-21 has labels which state the actual cy/mm of each element, so no look-up table is needed. Page 2 of 6 rev 1-00.doc

The T-22 further improves the pattern by arranging the elements in straight lines (much easier to locate, much easier to scan). Of course, it still meets the requirements of Mil-Std-150A. Finder squares have been added to help determine which element is being viewed, when the labels cannot be clearly seen. Page 3 of 6 rev 1-00.doc

Many other types of resolution test charts exist. The NBS-1010/ISO #2 (Applied Image T-10) is similar to the USAF-1951 chart, but has longer bars, and uses 5 bars instead of 3. The T-10 is marked directly in cy/mm and is used extensively in the microfilm field. Test charts can be made with a variety of contrast levels. Using a test chart with low contrast (a gray on white image is typical) is a more stringent test than high contrast because as lenses are introduced into an image path, one of the major degradations it causes is the reduction of contrast. Therefore, if the initial test object is lower contrast, any reduction in contrast will be a bigger part of the total signal. Page 4 of 6 rev 1-00.doc

Other types of test charts, such as the Sayce (T-60), are very well suited for scanning. Each line gets progressively smaller so a large range of line widths can be checked easily. Page 5 of 6 rev 1-00.doc

Sine patterns such as the M-5 array shown, allow a more sophisticated analysis. By scanning the sinusoidal density patches (of different frequencies) and evaluating them, the modulation transfer function (MTF) of a system can be determined. Another way to evaluate optical systems is to start with a very sharply defined edge, with known characteristics (such as the dark gray on light gray slant edge of the QA-62), capture the image with a digital imager, then evaluate the image with the proper software. This also provides MTF data. A complete catalog of standard test charts, scales, bar code standards, gray scale step tablets, and sine patterns can be found at www.aig-imaging.com. Page 6 of 6 rev 1-00.doc