FAG Detector II the mobile among data collectors. Technical Product Information

Similar documents
FAG Detector III The solution for monitoring and balancing. Technical Product Information

FAG Detector III The solution for monitoring and balancing. Technical Product Information

FAG Detector III The Solution for Monitoring and Balancing

FAG ProCheck State of the art machine monitoring for maximum availability

The new generation More comfortable even faster more precise SmartBalancer2 Perfect field balancing made easy

VIBXPERT. 2-Channel Vibration Analyzer. 102,400 lines of resolution. Weighs only 2.2 lbs. Simple joystick operation. Signal post processing

For Isotropic Measurement of Magnetic and Electric Fields

HMZ Locknuts simple and reliable locking devices

Advanced Test Equipment Rentals ATEC (2832)

C.A 8332 C.A Advanced Test Equipment Rentals ATEC (2832) Display your network analysis all in picture format!

PQ-Box 100 Network Analyzer for Low-, Medium- and High-Voltage Networks

C.A 8332 C.A Display your network analysis all in picture format! OBSERVE, DIAGNOSE, MONITOR... Three Phase Power Quality Analysers

Medidores de vibración salida RS232 Datalogger VT-8204 LUTRON manual ingles

Safety Evaluation Within a Magnetic Field Environment

Wireless Simple Diagnostic System for Rotating Machine Vibration

metro B6012 VIBRATIONS SIMPLIFIED... Product brochure Easiest portable vibration analyzer and balancer TECHNOLOGIES PVT. LTD.

Motor Vibration. Detect Mechanical & Electrical Motor Faults with Vibration Monitoring Instrumentation. IMI Sensors - A PCB Piezotronics Division

Safety Evaluation Within a Magnetic Field Environment

CONTINUOUS CONDITION MONITORING WITH VIBRATION TRANSMITTERS AND PLANT PLCS

Exposure Level Tester ELT-400

Selective and broadband low frequency field analysis

NHT 3DL. The new landmark meter for electromagnetic safety. Percipere Aestimare et Inquirere

4830B accelerometer simulator Product overview

VIBRATION ANALYZER. Vibration Analyzer VA-12

SC200 Series. Signal Conditioner MNX10020, REV H 10/17/ Connection Technology Center, Inc Rae Boulevard Victor, NY (585)

MAGNETIC FIELD MEASURING

C.A Complete electrical network analysis at the tips of your fingers! Power Quality Monitor. Keeping up with the standards

C4000. inline control. Photometric Converter. Real-time photometric converter. Factory zero for scattered light sensors

VIBRATION ANALYZER. Vibration Analyzer VA-12

Applications Features

Vibration Measurement Instruments VIBER X2. Manual. Ver. 2.5 Refers to VIBER X2 rev: 1.7 Software 5.0

T H E Q U A L I T Y L I N K. O v e n T e m p e r a t u r e P r o f i l e r

Selective and broadband high frequency field analysis

CSI 9330 Vibration Transmitter

9330 Vibration Transmitter

- GOMS II. -GOMS II Gearbox Online Monitoring System. P o w e r T r a n s m i s s i o n. Application Note Wind Energy

OPVibr Ultrasonic vibration measurement system Ultrasonic vibrometer INSTRUCTION MANUAL

METRISO. Analog Insulation, Low Resistance and Voltage Measurement Instrument /9.14

T10F. Data Sheet. Torque Flange. Special features. Installation example T10F. B en

Digital insulation tester

Hand held devices. Series MH - for temperature

CONTENTS. User Manual

VMS 830. Vibro-Meter Vibration Monitor FEATURES GENERAL. Absolute vibration measurement. Monitoring of machines and industrial plants

Machine Data Acquisition. Powerful vibration data collectors, controllers, sensors, and field analyzers

R&S FSC Spectrum Analyzer Specifications

Handheld Spectrum Analyzer R&S FSH khz to 3 GHz

1510A PRECISION SIGNAL SIMULATOR

UltraTEV Locator. Portable PD (Partial Discharge) investigation system. benefits. features. FACT: 85% of disruptive substation failures are PD-related

Analysis of static and time-variable magnetic fields

Metis H311 / H322. Highly Advanced, Full Featured 2-Color High-Speed Pyrometers

Network Analyzer for Low-, Medium- and High-Voltage Networks

ASC IMU 7.X.Y. Inertial Measurement Unit (IMU) Description.

Technical Specification Temperature-Humidity-Pressure Sensor

Moving Test - MT3000

WHITE PAPER. Continuous Condition Monitoring with Vibration Transmitters and Plant PLCs

MAGNETIC FIELD METER Operator s Manual

KATflow 230 Portable Clamp-On Ultrasonic Flowmeter

QUICK SETUP GUIDE SECULIFE HITAM

: FALCON Technical data sheet

MOISTURE ANALYZERS FAST COMPETENT RELIABLE DIVERSE. GB KERN Professional measuring.

P50 Thermal Printer Owner s Manual

Portable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an

Complimentary Reference Material

Instruction also available on

Vibration amplifier Model 6634C

MTN/8066/G-MAC VIBRATION MODULE

UltraTEV Locator Portable Partial Discharge (PD) investigation system.

Sensors for Research & Development and Machinery Health Monitoring

Enhanced API 670 monitoring of gearboxes

Presented By: Michael Miller RE Mason

HZ530 Near-Field Probe Set

XY-Stages series 5102

Network Analyzer for Low-, Medium- and High-Voltage Networks

MSO Supplied with a full SDK including example programs Software compatible with Windows XP, Windows Vista and Windows 7 Free Technical Support

Introduction ORANGE PEEL / DOI. Structure size. Color Physical Properties Technical Service Index

Coating Thickness Measurement System

Response Plus & Link Paging Systems Data Sheet

S5101 Handheld Radio Communication Analyzer

Application Note. Monitoring strategy Diagnosing gearbox damage

T10FS. Data Sheet. Torque Flange. Special features. Installation example T10FS. B en

NEW! Transient Data Acquisition. Stand alone. Compact. Powerful.

Selective and broadband low frequency field analysis

Energy Explorer PROFESSIONAL POWER & HARMONICS ANALYSER

POSICHRON position sensor in a stainless steel pressure case. Voltage: V, 3 wire Current: ma, 3 wire

Handheld Spectrum Analyzer R&S FSH3

Catalog VIBNODE. Online Condition Monitoring for standard machinery

Wind Turbine Analysis System - Type 3652 MKII & MKIII

LASER. Analog Laser Displacement Transducer. LAM Series. Key-Features: Content:

Digital Function Generator

Weld Checkers RESISTANCE WELDING

A4900 Vibrio M pocket guide

Operating Instructions GEMINI R

Product Information ROC 424 S ROQ 436 S. Absolute Rotary Encoders with DRIVE-CLiQ Interface for Safety-Related Applications

METRAClip87 and 88 Clamp Multimeters

PROFiTEST C Test Instrument per DIN VDE /8.14

Keysight Technologies U5850 Series TrueIR Thermal Imagers

The experience of the Qualistar ensuring high performance

PHG 70 TD PD / PHG 80 TD PD

Portable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an

Technical Data Sensor Input Input voltage measuring range (FSO) V 0 ±10 Max. input voltage V <±15 Resolution mv 5 with oversampling 14 Bit mv

Transcription:

FAG II the mobile among data collectors Technical Product Information

Application Condition-based maintenance Principle Application The FAG II is a vibration measuring device and data collector rolled into one. Together with the software Trendline, the device was developed for data collection in offline plant monitoring. The FAG II is easy and comfortable to use. It has a low mass. It is thus suitable for the monitoring of large plants where a measurement round would involve covering a considerable distance. With this device, parameters for vibration acceleration and vibration velocity can be measured in freely definable frequency bands. Machine vibrations are monitored according to ISO 10816 and the rolling bearing condition can be assessed by means of the demodulation detection method. Raw and demodulated signals can be stored and thus more detailed analysis of the vibration signals can be carried out in relation to time and frequency ranges. Imbalance and misalignment can be detected precisely, as can rolling bearing damage and gear problems. In addition, the device is equipped with a temperature measurement probe. which is absolutely essential for this type of maintenance, can be recovered in a very short space of time. This is particularly true if the reasonably priced, easy to use and handy FAG II is chosen. The device is also suitable for personnel that have no knowledge of vibration measurement. Use of the device is straight forward and can be learnt quickly. The user can generate individual routes and is then guided systematically from one measurement point to the next. The acceleration sensor is attached to the machine by means of a magnetic foot. At any time, the user can depart from a previously defined measurement round and add further measurement points. Data are measured and stored by simply pressing a key. The principle The FAG II measures vibration signals at predefined measurement points using a sensor and uses these to calculate the RMS values for vibration velocity, vibration acceleration and demodulated acceleration. These values for characterising the machine or component condition are described in further detail in the table on page 6. Frequency bands of any width between 2 Hz and 20 khz can be defined and monitored. The FAG II has a dynamic memory management system and the base version can store up to 24 time signals. With expanded memory, up to 116 time signals can be stored using the FIS.DETECTORII.SET.1MB. Condition-based maintenance Condition-based maintenance means: identifying damage at an early stage, defining planned repairs, making optimum use of bearing life, and achieving considerable reduction in costs, in particular those relating to production stoppages. The costs of purchasing a diagnostic device, 3

Principle Operation With an infrared sensor, this device can also be used for non-contact temperature measurement. After a measurement round, the parameters measured are transferred to a computer for evaluation, analysis and diagrammatic presentation using the software Trendline. The precise location of the measurement points within the plant to be monitored is filled in the configuration. This also contains the sensor sensitivity and limit values for the main alarm and pre-alarm for each measurement point. The configuration is generated using the software FAG Trendline and transferred to the prior to measurement. The sensor must be securely attached as close as possible to the point to be measured. In general, it is attached by means of the screw-mounted magnetic foot. If this is not possible, for example with an aluminium housing, a small iron plate or support washer with the same size as the magnetic foot is attached to the measurement point. This can be carried out using hard-curing instant adhesives (e.g. cyanoacrylate adhesives). On the FAG II, this measurement location is selected in the configuration and measurement is started. During measurement, the speed should be constant (at least 120 or 600 min 1 are required for Vsel or ISO 10816 respectively). The device records the sensor signals according to the selected bandwidths and calculates the characteristic values. For each configuration, the FAG II compares the new measured characteristic values with the defined limit values for main alarm and pre-alarm for this measurement location. If one of these threshold values is exceeded, this is displayed immediately on the device. After a measurement session, the stored values are transferred to the computer. With the aid of trend analysis, the user can estimate when an alarm will probably be triggered. When an alarm is triggered, an alarm report can be generated and printed out. In order to ensure comparability of values, they should be recorded under identical conditions. After an initial reference measurement, measurements are carried out at regular intervals. E-mail button on the FAG II One very useful feature of the software, particularly for users with little experience of vibration measurement, is the e-mail button. This can be used to send measurement data to a vibration expert by e-mail at the touch of a button. In this way, an external diagnosis expert can be consulted for sophisticated analyses. Our F IS service department will always be pleased to help you with such analyses. User friendly The display on the FAG II shows the user all the information needed to operate the device: selection of the measurement point, user guidance during measurement, display of measurement results, the system settings. The device can be easily operated using just the six keys on the soft keyboard. 4

Features Ordering designation and scope of delivery Features If you wish: you collect the data, we carry out a remote diagnosis Portable, handy, easy to use diagnostic device Low mass 450 g Operation with one hand using 6 keys Dust and spray-resistant soft keyboard Working temperature 0 to 50 C Automatic switch off after approx. 2 minutes Monitoring functions: general vibration condition rolling bearing condition data collector for up to 1200 measurement points headset jack for acoustic noise assessment Storage and display of up to 4 measurement values per measurement point for straightforward condition assessment Simple trend/graphics software with database for WIN 98/NT/2000/XP Sensor cable length possible up to 50 m Ordering designation and scope of delivery Ordering designation: FIS.DETECTORII.SET or FIS.DETECTORII.SET.1MB FAG DETECTOR II Scope of delivery: Basic device with storage battery Acceleration pickup with magnetic foot Temperature sensor Power pack data cable User manual Protective bag with holder for temperature sensor software Trendline Case USB serial adapter Accessories Second attachable bag for holding acceleration sensor Sensor extension cables for lengths of 5 m and 15 m are available on request 5

Selection of characteristic values Selection of characteristic values Possible characteristic values and signals Measurement range/resolution Frequency range Display for each measurement point Characteristic value: vibration severity to ISO 10816 (VDI 2056) (broadband RMS value of vibration velocity) for general assessment of machine condition according to ISO 10816 ISO 10816 = 0 999,9 mm/s 10 Hz 1 khz Characteristic value: vibration severity (freely selectable) (RMS value of vibration velocity, e.g. for detection of imbalances and misalignment) V sel = 0 999,9 mm/s Freely selectable between 2 Hz and 1 khz Characteristic value: acceleration (broadband RMS value of vibration acceleration, e.g. for monitoring of gearboxes) A eff = 0 25 g 2 khz 20 khz Characteristic value: acceleration (freely selectable) (e.g. for selection gear set monitoring) A sel = 0 25 g Freely selectable between 15 Hz and 20 khz Characteristic value: demodulated signal 100 Hz/1000 Hz (RMS value of demodulated signal up to 100/ 1000 Hz, e.g. for monitoring of rolling bearing condition) D eff/tp100/1000 Hz = 0 25 g 0 Hz 100 Hz/ 0 Hz 1000 Hz Characteristic value: demodulated signal 100 Hz/1000 Hz (freely selectable) (e.g. for selective monitoring of rolling bearing condition) D sel/tp100/1000hz = 0 25 g Freely selectable 0 Hz 100 Hz/ 0 Hz 1000 Hz Time signal of vibration acceleration up to 1 khz, 4096 values ±25 g 2 Hz at 1 khz Time signal of vibration acceleration up to 20 khz, 4096 values ±25 g 2 Hz at 20 khz Demodulated time signal up to 100 Hz, up to 1 khz ±25 g 0 Hz to 100 Hz 0 Hz to 1 khz Frequency spectrum (Fourier transform) of time signal of vibration velocity up to 1 khz ±999,9 mm/s Resolution: 0,73 Hz 2 Hz to 1 khz Frequency spectrum (Fourier transform) of time signal of vibration acceleration up to 20 khz ±25 g, Resolution: 14,6 Hz 15 Hz to 20 khz Frequency spectrum (Fourier transform) of time signal of demodulated signal or up to 100 Hz or up to 1 khz ±25 g, Resolution: 0,073 Hz (at 100 Hz), 0,73 Hz (at 1 Hz) 0 Hz to 100 Hz or 0 Hz to 1 khz Measurement point temperature Temp = 15 C to 240 C 6 On the, the user can specify for each measurement point whether and under what conditions certain time signals are to be stored. Three different time signals can be measured, namely vibration acceleration (2 Hz 1 khz, 3 khz scan rate), vibration acceleration (2 Hz 20 khz, 60 khz scan rate) and demodulated signal (0 Hz 100 Hz/1 khz, 300 Hz/3 khz scan rate). The can, depending on the memory size, store 24 or 116 time signals.

Technical data Device designation Dynamic memory interface Display Inputs Output languages Keyboard Manual Power supply Operating time Temperature range FAG II, ordering designation FIS.DETECTORII.SET with expanded memory FIS.DETECTORII.SET.1MB max. 1200 measurement points without time signals, Basic version: 256 kbyte, up to max. 24 time signals can be stored, with expanded memory: 1 Mbyte, up to max. 116 time signals can be stored RS 232, baud rate: 38,2 kbps 57,6 kbps Illuminated graphic display (LCD), 128 ~ 64 pixels Dimensions: 55 ~ 33 mm BNC jack for ICP acceleration sensor with adjustable sensitivity: (mv/g), 9 pin jack for pyrometer (IR temperature sensor), 9 pin DIP jack with RS232 interface for data cable supplied, Connector for battery charger Connector for headset with 3,5 mm jack plug (Walkman), signal: demodulated signal switchable between German, English, French, Dutch, Italian, Turkish, Spanish, Portuguese, Swedish and Finnish, other languages available by agreement 6 soft keys German, English and French Rechargeable NiMH batteries Approx. 6 8 hours (continuous operation) 0... +50 C (working temperature) 20... +70 C (transport and storage temperature) Dimensions (basic device) 230 ~ 70 (53) ~ 45 (53) mm (L ~ B ~ H) Mass (basic device) Protective bag software Trendline Temperature measurement ca. 450 g Two compartments, black nylon, 2 transparent film windows, openings with velcro fasteners, velcro holders for cable and sensor, carry strap Runs under WINDOWS 98/NT 4.0 SP6/2000/XP Configuration of FAG II via RS232 interface Hierarchy-based factory and measurement point manager with machine graphics facility Generation of any number of measurement routes on Integral database for storage of measurement values Graphic representation of measurement values and their behaviour, trend analysis and trend extrapolation Presentation of recorded time signals FFT presentation of time signals Report generator for alarms and measurement values Available in German, English, French and Portuguese (others in preparation) IR temperature sensor, handheld device for non-contact temperature measurement, measurement range 15... +240 C (1 mv/ C/ F), spectral range 8 14 µm, minimum target 2,5 mm, distance ratio 4 : 1, connector plug for DETECTOR II 7

98/09/05 Printed in Germany by Weppert Print & Media GmbH FAG Kugelfischer AG & Co. ohg P.O. Box 1260 D-97419 Schweinfurt Georg-Schäfer-Strasse 30 D-97421 Schweinfurt Service-Hotline Phone +49 2407 9149-99 Fax +49 2407 9149-59 www.fis-services.com Every care has been taken to ensure the correctness of the information contained in this publication but no liability can be accepted for any errors or omissions. We reserve the right to make changes in the interest of technical progress. by FAG 2005, September This publication or parts thereof may not be reproduced without our permission. TPI WL 80-62/2 E