F6052 Universal Time Synchronizer

Similar documents
TCG 02-G FULL FEATURED SATELLITE CLOCK KEY FEATURES SUPPORTS

TCG 02-G FULL FEATURED SATELLITE CLOCK KEY FEATURES SUPPORTS

PERFECT TIMING CRAIG PREUSS, P.E. HOW IEEE STANDARD PC IMPACTS SUBSTATION AUTOMATION

T200, PTP/IEEE 1588 Grandmaster Clock and

6135A/PMUCAL Phasor Measurement Unit Calibration System

Enabling Tomorrow s Technology Today

PHASOR TECHNOLOGY AND REAL-TIME DYNAMICS MONITORING SYSTEM (RTDMS) FREQUENTLY ASKED QUESTIONS (FAQS)

CONVERT ERLPhase TESLA DMEs TO PHASOR MEASUREMENT UNITS (PMUs)

Measurement tools at heart of Smart Grid need calibration to ensure reliability

T108, GPS/GLONASS/BEIDOU Time Server

Power Matters. Time Interfaces. Adam Wertheimer Applications Engineer. 03 November Microsemi Corporation.

Reason RT431. GE Grid Solutions. GPS Precision-Time Clock. Precise Time Synchronization. Compact Design. Hardened for Industry. Time Synchronization

Digital Fault Recorder Deployment at HVDC Converter Stations

Surviving and Operating Through GPS Denial and Deception Attack. Nathan Shults Kiewit Engineering Group Aaron Fansler AMPEX Intelligent Systems

Global Navigation Satellite System for IE 5000

Timing & Synchronisation

THE ROLE OF SYNCHROPHASORS IN THE INTEGRATION OF DISTRIBUTED ENERGY RESOURCES

satech SynchroStar GPS 200 Series

Your benefits using DTS 4160.grandmaster:

Business Opportunity. The wave is coming. The Opportunity. Time Synchronization as a first-order concept You take care of it, or you will pay for it!

Today's Lecture. Clocks in a Distributed System. Last Lecture RPC Important Lessons. Need for time synchronization. Time synchronization techniques

GPS10RBN-26: 10 MHz, GPS Disciplined, Ultra Low Noise Rubidium Frequency Standard

GPS Time Server Product Specifications and Installation Data

Your benefits using DTS 4160.grandmaster:

NMI's Role and Expertise in Synchronization Applications

New Standards for Test and Calibration of Phasor Measurement Units

Issue No : 2 Dt of Revision :

Study and Simulation of Phasor Measurement Unit for Wide Area Measurement System

Phasor Measurement Unit and Phasor Data Concentrator test with Real Time Digital Simulator

Specifications subject to change without notice Heartbeat of the Smart Grid

Trio Q. Licensed UHF Ethernet and Serial data radio. QH450 Hot Standby Full Duplex

SYNCHROPHASOR TECHNOLOGY GLOSSARY Revision Date: April 24, 2011

Establishing Traceability to UTC

Synchrometrology and PMU Testing at NIST

HOW TO RECEIVE UTC AND HOW TO PROVE ACCURACY

CURRENT ACTIVITIES OF THE NATIONAL STANDARD TIME AND FREQUENCY LABORATORY OF THE TELECOMMUNICATION LABORATORIES, CHT TELECOM CO., LTD.

Measuring Time Error. Tommy Cook, CEO.

Hamdy Faramawy Senior Application Specialist ABB Sweden

Partial Discharge Measurement and Monitoring on High Voltage XLPE Cables

GPS10RBN - 10 MHz, GPS Disciplined Rubidium Frequency Standard

Name: Craig Goodwin. Company Name: HV Diagnostics Inc

THE CHALLENGES OF TESTING PHASOR MEASUREMENT UNIT (PMU) WITH A DISTURBANCE FAULT RECORDER (DFR) Krish Narendra, Zhiying Zhang, John Lane

Trio Q. Licensed UHF Ethernet and Serial data radio. QB450 Full Duplex

Wide Area Monitoring with Phasor Measurement Data

DTS 4210.timecenter. Swiss Time Systems. High precision time server, grandmaster and PRC


Introduction to micropmu. PSL Australasian Symposium 2017 September 29 Thomas Pua Product Engineer

Correct Measurement of Timing and Synchronisation Signals - A Comprehensive Guide

SEL Serial Radio Transceiver. The industry-recognized standard for reliable, low-latency wireless communications

Monitoring Cable Technologies

SyncServer S600/S650 Options, Upgrades, and Antenna Accessories Maximize Performance and Flexibility

QAM Snare Snoop User Manual

SyncServer S650 Accurate, Secure, and Flexible Time and Frequency Standard

Non-Packet Time-of-Day Distribution

The Virginia Tech Calibration System

Digital GPS Repeaters for Wireless Network Timing

SyncBox/N2X: Converts NTP or IEEE-1588 to IRIG, 10MHz, PPS, DCF77 and serial time telegrams

PMU Implementation Issues

Time Traceability for the Finance Sector Fact Sheet

APPLICATION OF PMUS FOR MONITORING A 50 KV DISTRIBUTION GRID

Digital Instruments S.r.l. GPS-MXS. Multireference Time-Frequency

SyncServer S600/S650 Options, Upgrades and Antenna Accessories

Micro-synchrophasors (µpmus) in Electric Power Distribution Systems 5/29/15 SF PES Chapter Workshop

Practical PMU Applications for Utilities

SEL-311C TRANSMISSION PROTECTION SYSTEM

REPORT OF TIME AND FREQUENCY LABORATORY (VIETNAM METROLOGY INSTITUTE)

Sigfox RF & Protocol Test Procedure RSA-SDR-DONGLE for RC3c-UDL-ENC

ETSU V/06/00187//REP; DTI Pub/URN 01/799 (for Ove Arup reference:

Synchrophasors and the Smarter Grid

Wireless Gas Detection System

WP4-Hardware in the Loop Validation of the EFCC Scheme

Applications and Advantages of USB RF Power Sensors Richard R Hawkins, President LadyBug Technologies LLC

RT- HIL Implementation of Hybrid Synchrophasor and GOOSE- based Passive Islanding Schemes

3 Phase Power Quality Analy er

SynchroPhasor use at OG&E. Austin D. White P.E. Steven E. Chisholm Oklahoma Gas & Electric

STATUS REPORT OF TIME AND FREQUENCY LAB. (VIETNAM METROLOGY INSTITUTE)

Upgradation and Strengthening of National Time Scale of India

GPS10R - 10 MHz, GPS Disciplined, Rubidium Frequency Standards

Jean-Pierre Braun obtained the B.E. degree from the Ecole d'ingénieurs de Genève, Switzerland, in 1980; the M.E.M. degree from the University of

The Effect of Delays on Wide-Area Damping Control of Electromechanical Oscillations

Wide Area Measurement System Integration. GE Consumer & Industrial Multilin

ITU-T G.8272/Y.1367 (01/2015) Timing characteristics of primary reference time clocks

Metrological and legal traceability of time signals

SyncServer S600/S650 Options, Upgrades, and Antenna Accessories Maximize Performance and Flexibility

Timing in Mission-Critical Systems

Power Analyser AM-10-PA2

LANTIME Network Time Servers

GPS Satellite-Controlled Clock

Prepared by Tony Weekes Husam Al Hadidi Brian Archer

Why Industry Needs Time A Power Industry Case Study

WPI Precision Personnel Location System: Synchronization of Wireless Transceiver Units

GPS Timing In Substations: Past, Present, & Future

Microgrid Islanding with a Battery Energy Storage System (BESS) Gabriel Haines

Critical Evaluation of the Motorola M12+ GPS Timing Receiver vs. the Master Clock at the United States Naval Observatory, Washington DC.

Reason RT430/RT434. GE Grid Solutions. GNSS Precision-Time Clocks. Precise Time Synchronization. Flexible Design. Hardened for Industry.

Accurate Synchrophasor Estimation to Support the Islanding Maneuver of Active Distribution Networks

Fuel cell power system connection. Dynamics and Control of Distributed Power Systems. DC storage. DC/DC boost converter (1)

EFCC Academia dissemination event

PRY-CAM BREAKTHROUGH TECHNOLOGY FOR CONDITION ASSESSMENT AND ASSET MANAGEMENT

Fundamentals of Precision Time Protocol. Rudy Klecka Cisco Systems. October 14, 2015

Transcription:

F6052 Universal Time Synchronizer Doble Engineering Company March 2014 2013 Doble Engineering Company. All Rights Reserved 1 2013 Doble Engineering Company. All Rights Reserved

History of Portable Time John Harrison: 1693-1776 Marine Chronometer for Navigation Accuracy 10s of seconds per day Ruth Bellville: 1854-1943 The Greenwich Time Lady Brought time to London s watchmakers Accuracy 10s of milliseconds per day Doble Engineering: 2013 F6052 Accuracy 10s of nanoseconds per hour 2013 Doble Engineering Company. All Rights Reserved 2

Drivers, Then and Now Then Marine Navigation Calibration of Clocks Clock Makers, Transport, Banks Now: Calibration to UTC Financial Companies Mobile Operators Power Utilities (Smart Grids) Broadcasters Transport Infrastructure UTC (Universal Co-ordinated Time) is the Global Standard for Time! 2013 Doble Engineering Company. All Rights Reserved 3

F6052 Universal Time Synchronizer A portable Grand Master Clock capable of a synchronized signals in multiple formats for time stamping and testing without an active signal. F6052 2013 Doble Engineering Company. All Rights Reserved 4

F6052 Performance 100ns over 4 hours or 200ns over 8 hours (+/-10C temp change) with no Signal 8 hours on battery if no external power is available Variable effective operating time Depends on the signal being measured Reference should ideally be an order of magnitude better than Device Under Test May be extended if mains power available Outputs squelched to prevent incorrect use LED s indicate effective operating condition 2013 Doble Engineering Company. All Rights Reserved 5

F6052 Key Features 1588_v2 GM Profiles NTP Server Legacy IRIG-B output timing port 2 x Frequency outputs SyncE output 1PPS output 1PPS phase comparator Physical Attributes Size: 190 x 57 x 170mm (WxHxL) Weight: 750g High performance internal chip scale atomic oscillator software support Auto Calibrated Local & Secure remote management Portable timing receiver Mains & battery operated 2013 Doble Engineering Company. All Rights Reserved 6

F6052 Feature Power Applications End-to-end testing: Ideal for end-to-end testing in locations where an IRIG-B source is not available Phasor measurement units: Useful for testing of PMUs per IEEE standard C37.118 IEC61850 compliant testing: Capable of IEC compliant testing where time stamped requirements are a must for Goose and Sampled Values message monitoring and evaluation 2013 Doble Engineering Company. All Rights Reserved 7

Single end protection relay testing Portable reference for all Power Test Equipment Freq & Time Protection Relay (DUT) Outside Power Tester Test Voltages & Currents Inside Electrical substation Hydro plant Nuclear Generator Gas Generator 2013 Doble Engineering Company. All Rights Reserved 8

End to End Protection Relay Testing Portable reference for all Power Test Equipment free location available location Tester Protection Relay (DUT) Communications Protection Relay (DUT) Tester 2013 Doble Engineering Company. All Rights Reserved 9

PMU Testing Grandmaster PMU PMU Receiver Phasor Measured at Time T 1 Phasor Data Concentration (PDC) Phasor Measured at Time T 1 PMUs are revolutionizing wide area grid monitoring and control Measures voltage & current waveforms at points across the grid... PMU reference is UTC traceable and synchronised to 1 microsecond to UTC PMU data (up to 120 per second) sent to Phasor Data Concentrators (PDC) enables real time visibility and control. 2013 Doble Engineering Company. All Rights Reserved 10

Power Plant Board Transfer Schemes Supply A Supply B Freq & Time Protection Relay (DUT) Transfer Board A Transfer Board B Freq & Time Protection Relay (DUT) Power Tester Test Voltages & Currents Power Tester Test Voltages & Currents Unit Board 1 ID Fan 1 Circ Pump 1 ID Fan 2 Circ Pump 2 2013 Doble Engineering Company. All Rights Reserved 11

Wind turbine calibration Antenna Splitter The supply vessel transports powered up (calibrated) F6052 units to each wind turbine. The unit is then unattached and in the turbine for commissioning and support activity 2013 Doble Engineering Company. All Rights Reserved 12

Calibration of UTC systems TimePort system, antenna, cable and unit is / must be calibrated. Antenna C L1 TDR D We are measuring the delay between C & D thus proving media integrity. RF OSC Receiver receivers are not standardised so performance varies. 1PPS A We are measuring the Phase difference between A & B. This is the Application performance. 2013 Doble Engineering Company. All Rights Reserved 13 B

One Way Packet Delay Measurement signals available and trusted at this location. Sync. Tester Packet flow No ability to get inside the equipment room or existing is not trusted. Inside R R R R R R True one way packet delay 2013 Doble Engineering Company. All Rights Reserved 14

Fault Finding a 1PPS Signal Isolates the fault to the East or West of the point at which the test flow is injected in to the network. Existing client hardware is reconfigured to receive flow 2 from the temporary F6052 GM and the effect is seen on second F6052 measuring the 1PPS signal. Grandmaster R R R R R R Fault is isolated to upstream Fault is isolated to downstream 1 2 1PPS Client 2013 Doble Engineering Company. All Rights Reserved 15

Fault finding a v2 in flow Isolates the fault to the East or West of the point at which the test flow is injected in to the network. Grandmaster R R R R R R Fault is isolated to upstream Existing client hardware is reconfigured to receive flow from the temporary 2 F6052 GM. A new flow is set up to a capable sync tester. Fault is isolated to downstream 2013 Doble Engineering Company. All Rights Reserved 16 3 3 Sync. Tester 1 2 Client

Reference Device to Other Testers No ability to get inside the equipment room or existing is not trusted. Inside 1PPS UTC Sync. Tester Grandmaster R R R R R R True one way packet delay Client 2013 Doble Engineering Company. All Rights Reserved 17

Supporting and Assuring a Time Service Regional Hub2 Server Modem Server Modem Temp Source of UTC Server Country - UTC 1PPS Dark Fibre NTP/ 10MHz Regional Hub1 1PPS Comparison Local Distribution Modem Modem Modem Time Service Assurance Modem Server Server Server 1PPS Comparison 2013 Doble Engineering Company. All Rights Reserved Time Service 18 Assurance

Calibration of UTC systems F6052 system, antenna, cable and unit is / must be calibrated. Antenna C L1 TDR D We are measuring the delay between C & D thus proving media integrity. RF OSC Receiver receivers are not standardised so performance varies. 1PPS We are measuring the Phase difference between A & B. This is the Application performance. 2013 Doble Engineering Company. All Rights Reserved 19 A B

UTC offset calibration / certification Clear view of the sky allows F6052 unit to acquire your own source of Trusted Time. system delay measurement depends on interfaces available on the customer equipment F6052 A 1PPS Antenna Splitter UTC Offset Report F6052 B ------------------------ Option -------------------------------- Customer Equipment Outside UTC Offset Report F6052 A Inside 1PPS 2013 Doble Engineering Company. All Rights Reserved 20

F6052 Hardware Design 2013 Doble Engineering Company. All Rights Reserved 21 21

F6052 Hardware Interface F6052 2013 Doble Engineering Company. All Rights Reserved 22

F6052 Hardware Interface F6052 2013 Doble Engineering Company. All Rights Reserved 23