For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Similar documents
For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

V P N. Voltage transducer DVM 4200 = 4200 V

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Unipolar voltage - Current output 4-20 ma Ref: DVL 50-UI, DVL 150-UI, DVL 250-UI, DVL 500-UI, DVL 750-UI, DVL 1000-UI, DVL 1500-UI

= 600 V. Voltage transducer DVM 600 V PN

= 1000 V. Voltage transducer DVC 1000-P V P N

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

V P N. Voltage transducer DVL 1000 = 1000 V

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

V P N. Voltage transducer DVM 2000-B = 2000 V

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

Ref: HO 50-S/SP33, HO 100-S/SP33, HO 150-S/SP33, HO 200-S/SP33, HO 250-S/SP33

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

Ref: HLSR 10-P/SP3, HLSR 20-P/SP3, HLSR 40-P/SP3, HLSR 50-P/SP3

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit.

High Performance Current Transducer ITL 900-T = A

Ref: HLSR 10-SM/SP33, HLSR 20-SM/SP33, HLSR 32-SM/SP33, HLSR 40-P/SP33, HLSR 50-SM/SP33

HO 50-S/SP30, HO 100-S/SP30, HO 150-S/SP30, HO 200-S/SP30, HO 250-S/SP30 and HO 200-S/SP31

Ref: HLSR 10-SM, HLSR 16-SM, HLSR 20-SM, HLSR 32-SM, HLSR 40-SM, HLSR 50-SM

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

I PN. Ref: HO 50-S, HO 100-S, HO 150-S, HO 200-S, HO 240-S, HO 250-S

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Voltage transducer DVL 50

I P. /dt. di p V S Applications. Standards 1) IEC : 2007; IEC : ) IEC : 2016; IEC : 2017

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Current Transducer CTSR 1-P = 1A

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

I P. /dt. di p V S+ Applications. Standards. 1) IEC ed1.0: 2007; IEC : ed1.0: 2012

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

I Pr I P I OUT R L. Applications. Standards

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit.

I P I OUT R L. Applications. Standards. N 52.D ; Page 1/8

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit.

I PM. Current Transducer ITZ 5000-SB FLEX ULTRASTAB = 5000 A

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1DRW 300-S

The four pin one (J1) makes possible to supply the board and access to the output voltage easily. It has the following pin-out:

DS2000ICLA. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.

DS200ID-CD100. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 2 ppm. MPS for particles accelerators

DS2000UBLA-10V. Features. Applications: 20 ppm linearity. MPS for particles accelerators. 15 ppm offset. Gradient amplifiers for MRI devices

DM1200ID. Specification highlights Symbol Unit Min Typ Max. Applications: Features. Power measurement and power analysis

SPECIFICATION Item No.: T60404-P4640-X100

DS400ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1.5 ppm. MPS for particles accelerators

DS10000ULFS-10V/10kA

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH3DR 1100-S07

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH3DR 800-S03/SP2

DL2000ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.

AUTOMOTIVE CURRENT TRANSDUCER HC2F100-SN CLIPS

DQ600ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1 ppm. MPS for particles accelerators

Residual Current Monitoring Unit RCMU101SN-4P16C

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY DHAB S/124

Residual Current Monitoring Unit RCMU101SN-4P16

SPECIFICATION Item No.: T60404-P4640-X102

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY DHAB S/157

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HSW S01

AUTOMOTIVE CURRENT TRANSDUCER HAH3DR 700-S00

Customer: Standard type Page 1 of 7 Description Fluxgate current sensor with toroidal core PCB mounting

CMS2005 MagnetoResistive Current Sensor (I PN

HC2F100-SN CLIPS AUTOMOTIVE CURRENT TRANSDUCER HC2F100-SN CLIPS. Datasheet

AUTOMOTIVE CURRENT TRANSDUCER HAH3DR 700-S02

Customer: Standard type Page 1 of 7 Description Fluxgate current sensor with toroidal core PCB mounting

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH3DR 800-S0C

AUTOMOTIVE CURRENT SENSOR HC6H500-S. Datasheet

CMS2050 MagnetoResistive Current Sensor (I PN

SPECIFICATION Item no.: T60404-N4646-X764

SPECIFICATION Item no.: T60404-N4646-X400

AUTOMOTIVE CURRENT TRANSDUCERS OPEN LOOP TECHNOLOGY

AUTOMOTIVE CURRENT SENSOR HC6H300-S

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1DR 200-S

AUTOMOTIVE CURRENT TRANSDUCER HC6F600-S

AUTOMOTIVE CURRENT TRANSDUCER HC6H1000-S

AUTOMOTIVE CURRENT TRANSDUCER HAH1DR 300-S

CMS3050 Highly Dynamic MagnetoResistive Current Sensor (I PN

Type CP-S, CP-C & CP-A Switch mode

AUTOMOTIVE CURRENT TRANSDUCER HC6F700-S

Current transducer FHS 40-P/SP600

Power supply CP-D 24/4.2 Primary switch mode power supply

AUTOMOTIVE CURRENT TRANSDUCER FLUXGATE TECHNOLOGY CAB 300-C/SP3-XXX

Current Sensor : F02P***S05L

Transcription:

Current Transducer ITL 4000-S I PN = 4000 A For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. I > 0 P Features Closed lp (compensated) current transducer Current output Bipolar supply voltage High accuracy Ingress protection rating IP54. Advantages Standards EN 50178: 1997 EN 61010-1: 2010 UL 94-V0 RoHS. Application Domain Industrial. Integrated design Low cost Large aperture. Applications HVDC Medium voltage PFC and active filters Small DC component detection in large AC currents (transformer protection). N 97.C4.74.000.0 Page 1/8

Absolute maximum ratings Parameter Symbol Unit Value Maximum supply voltage (non-operating) V ±30 Primary conductor temperature T B C 70 Stresses above these ratings may cause permanent damage. Exposure to absolute maximum ratings for extended periods may degrade reliability. Insulation crdination Insulation between primary and secondary + shield Parameter Symbol Unit Value Comment Rated insulation rms voltage reinforced or basic insulation U b kv 1.5 Rms voltage for AC insulation test, 50/60 Hz, 1 min U d kv 6.4 100% tested Impulse withstand voltage 1.2/50 µs Û W kv 16.5 Partial discharge extinction rms voltage @ 10 pc U e kv 2.65 Clearance (pri. - sec.) d CI mm >130 Creepage distance (pri. - sec.) d Cp mm >200 Comparative tracking index CTI V >600 Overvoltage category - CAT III Pollution degree - PD2 Reinforced insulation, according to EN 61010 Insulation between shield and secondary Rated insulation voltage U b V 150 Rms voltage for AC insulation test, 50/60 Hz, 1 min U d kv 2.7 100% tested Impulse withstand voltage 1.2/50 µs Û W kv 5 Clearance (pri. - sec.) d CI mm >4 Creepage distance (pri. - sec.) d Cp mm >5.5 Overvoltage category - CAT III Pollution degree - PD2 Reinforced insulation, according to EN 61010 Environmental and mechanical characteristics Parameter Symbol Unit Min Typ Max Comment Ambient operating temperature T A C -40 70 Ambient storage temperature T S C -40 70 Aperture diameter mm 265 268 Dimensions (W H D) mm 500 643 118 Mass m kg 40 Page 2/8

Electrical data At T A = 25 C, = ± 24 V unless otherwise noted. Parameter Symbol Unit Min Typ Max Comment Primary nominal rms current I PN A 4000 Primary current, measuring range I PM A 12000 Secondary current I S A 1.6 4.8 Number of secondary turns N S 2500 Bipolar supply voltage V ±22.8 ±24 ±25.2 Current consumption I C A 0.22 + I S 0.35 + I S Measuring resistance R M Ω 0 1 Offset current I OE ma -0.1 0.1 Sensitivity error ε G % -0.04 0.04 Linearity error ε L -0.01 0.01 Maximum offset change after 5 I PN I OM ma -0.2 0.2 @ I PM, T CU = 100 C, cable resistance included (see fig. 1 and 2) Temperature variation of I O I OT ma -0.1 0.1-40 C.. 70 C Output rms current noise 0.1 Hz.. 10 khz I no A 0.5 Input referred, rms Reaction time @ 10 t ra µs 2 @ I PN, 100 A/µs Step response time to 90 % of I PN t r µs 10 @ I PN, 100 A/µs Frequency bandwidth (± 1 db) BW khz 50 Overall accuracy X G -0.06 0.06 @ I P (rms) = 40 A, R M = 50 Ω Overall accuracy X G -0.08 0.08 In temperature range -40 C.. 70 C Total error from I PN DC = -10 A up to +10 A Output deviation under test according to IEC 61000-4-3 Output deviation under test according to IEC 61000-4-6 A -1 1 3 3 T A = -25 C.. 50 C I PN AC = I PN, max. 100 Hz Radiated immunity to RF fields, 80.. 1000 MHz Immunity to conducted disturbances of RF fields 0.15.. 80 MHz Definition of typical, minimum and maximum values Minimum and maximum values for specified limiting and safety conditions have to be understd as such as well as values shown in typical graphs. On the other hand, measured values are part of a statistical distribution that can be specified by an interval with upper and lower limits and a probability for measured values to lie within this interval. Unless otherwise stated (e.g. 100 % tested ), the LEM definition for such intervals designated with min and max is that the probability for values of samples to lie in this interval is 99.73 %. For a normal (Gaussian) distribution, this corresponds to an interval between -3 sigma and +3 sigma. If typical values are not obviously mean or average values, those values are defined to delimit intervals with a probability of 68.27 %, corresponding to an interval between -sigma and +sigma for a normal distribution. Typical, maximal and minimal values are determined during the initial characterization of a product. Page 3/8

Maximum measuring resistance (included cable) versus measuring range Maximum measuring resistance (Ω) 120.0 110.0 100.0 90.0 80.0 70.0 60.0 50.0 40.0 30.0 20.0 10.0 0.0 0 500 1000 1500 2000 2500 3000 3500 4000 = ± 24 V ± 5% T A = -40.. 70 C Maximum measuring resistance (Ω) 11.0 10.0 9.0 8.0 7.0 6.0 5.0 4.0 3.0 2.0 1.0 Uc = ± 24 V ± 5% T A = -40.. 70 C 0.0 4000 5000 6000 7000 8000 9000 10000 11000 12000 Measuring range (At) Measuring range (At) Figure 1: R M for ranges 0.. 4000 A Figure 2: R M for ranges 4000.. 12000 A Typical Bandwidth @ I P = 40 A Figure 3: Bandwidth Typical step response Ip = 4000 A, 100 A/ μs 10 μs/div, 800 A/div Figure 4: Step response di/dt Page 4/8

Installation Mounting The ITL 4000-S transducer should be mounted on a flat surface with its flat side against the surface. The IP54 degree of protection is guaranteed only if the ITL 4000-S transducer is mounted in a vertical position with the heatsink towards the top. In any case, the best thermal dissipation is obtained when the fins of the heatsink are oriented vertically. The transducer should be mounted with four screws complying with the inner diameter of the 4 bushings. Connection Remove the 4 screws that hold the small cover near the heatsink (see fig. 8). The tightening torque for these 4 screws is 1.3 Nm. The torque for the cable gland is 2.5 N m. Cable gland is foreseen for a cable diameter 5.5 to 12 mm. Connection wires to the terminal block shall be from 0.2 mm 2 to max. 4 mm 2 (AWG24 to AWG12). The tightening torque for the screws of the contact block is 0.7 N m. The ITL 4000-S transducer should be powered from a typical +24/-24 V power supply, the positive voltage connected to + (terminal 1), the negative voltage to - (terminal 3). Supply ground is not connected to the transducer. The measuring resistance R M should be connected between M (terminal 4) and ground (0 V). (see fig. 5) Before a primary current is applied to the ITL 4000 transducer, the secondary circuit has to be closed; this means that a burden resistance and a power supply unit must be connected. This power supply must be able to limit the voltage at the maximum specified voltage rating, even if a secondary current is injected (because of transformer effect) and even if this power supply is not powered. The heatsink and the measuring head are internally connected to the ground terminal (threaded stud) which is accessible on the heatsink side (see fig. 8); it should be connected to the ITL 4000-S local ground. M (measure) (4) - 24 V DC (3) + 24 V DC (1) black I S R M blue I P red Figure 5: Connection principle Customer side When the distance between the ITL 4000-S and the control device is long, a double screened cable should be used and connected as shown in the schematics below. The external cable screen should be connected to the ITL 4000-S ground; the internal cable screen should be connected to the ground potential which is close to the control device. R M Figure 6: Double screened cable for long connection Page 5/8

Electronics module replacement procedure 1.1 Removing of the old electronics module The electronics module (LEM reference 93.47.35.001.0) consists of the heatsink and the printed circuit board assembly which is pre-adjusted during manufacturing. Figure 7: Electronics module of ITL 4000-S The following procedure has to be followed: Turn off the input power of the 24 V power supply unit of the ITL 4000 current transducer. It is mandatory not to open the power supply connections to the transducer. See also recommendations under paragraph Connection. Remove the 6 screws that hold the heatsink (see fig. 8). Electronics module can be moved away from the housing by pulling out the heatsink (you may use some more force). Please take care of the wires inside that are connected to the nearby box (you should start by the side opposite to the connection box and pull it out for around 5 cm). When the module is open, you will have an access to the wires and one pin connectors. 6 screws for module dismounting Terminal block cover Start to pull out from this side ITL 4000-S ground terminal Figure 8: External view of ITL 4000-S Short-circuit the secondary winding of the transducer by engaging the two one pin connectors on the leads to the measuring head. Remove the three leads on Connector X1 (fig. 9), the six leads on connector X2 (fig. 10) and the shield connection to the heatsink (fig. 10). Page 6/8

1.2 Installation of the new electronics module Connect the new electronics module (colors as in fig. 9 and 10). Mounting torque for the earth connection screw is 0.55 N m; mounting torque for the terminal screws (3 and 6 leads) is 0.5 N m. Remove the secondary winding short circuit by disconnecting the one pin connectors. Put the heatsink in place (take care not to pinch any leads between heatsink and case) and fasten the 6 screws with a torque of 1.3 N m. Turn on the input power of the 24 V power supply unit. The ITL 4000 transducer is now operating. The electronics module is tested and adjusted before the shipment, therefore the expected accuracy of the ITL 4000 transducer with the new electronics module will respect requirements specified in the datasheet Shield connection Fig. 9: Connector X1 Fig. 10: Connector X2 and shield connection Page 7/8

Dimensions (in mm) dci dcp Connection I S R M I P Mechanical characteristics General tolerance ± 1 mm Transducer fastening by spacers 4 holes 13 mm 4 M12 steel screws Recommended fastening torque 17 N m Secondary link Connection cable on terminal block Internal acces by lid Remarks Installation of the transducer must be done unless otherwise specified on the datasheet, according to LEM Transducer Generic Mounting Rules. Please refer to LEM document N ANE120504 available on our Web site: Products/Product Documentation. Safety This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the manufacturer s operating instructions. Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/ or cause serious damage. This transducer is a build-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. Page 8/8